HOT AIR WOOD STOVE AIRVENT TECHNICAL DOCUMENTATION V. 1.1

Similar documents
MCL-BIO. Fuels. Main features. multifuel biomass boiler. group of companies

PELLET BURNER PV 350

BIX B-One 100 kw INSTALLATION GUIDE

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Installation & Manual. Model T-25

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

BIOPLEX MCL-BIO INSTALLATION AND SERVICE MANUAL

USER MANUAL 9kW LILLY PELLET STOVE

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

MG SERIES - ENERGY CLASS A. Meeting the. MG series 1 / 7

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

INSTALLATION AND OPERATION MANUAL

Ladan. Wood gasification boiler. Instruction for use, installation and assembly of boiler.

Masterflamme Convection Wood Stoves Perfect combustion with unique design

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

Combined boiler. for solid fuel and pellets

Operation and maintenance manual for the. KSP Spark. series boilers equipped with feeders

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

- 12, , TECHNICAL INSTRUCTIONS

PER-EKO type KSW & KSW PLUS Instruction Manual

Rocket heater GAMERA

Light oil burners. One stage operation

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

16 XD Mk2 Inset Electric Fire

Cookshack, Inc. Model FEC100 Fast Eddy Oven. Version /1/10

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

1. GENERAL SAFETY RULES

ISO 9001 TUV CERT CE

PELLETS BURNER 15-60kW MOC

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Installation and Operating Instructions

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Corn Flame Energy Corn Stove Model 3000

Light oil - kerosene burner

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

DEVRON SERIES MULTI FUEL FIRED GASIFICATION HOT WATER BOILERS DEVRON-30, DEVRON-40 OPERATION, USE AND MAINTENANCE MANUAL

Heating with log wood

Boiler Technical Specifications (2013)

Heating and Energy Saving Systems pellet biomass wood solar energy gas oil

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

ACCUMULATION OF EUROPEAN CLASS

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

WARNING! For your safety

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

Pellet burner PV 180a. User manual

Installation and Operating Instructions

Cm Pelet-set (60-90 kw)

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Aquaflam Wood boiler stoves and fireplace inserts

AE2400 Elite Series Ceramic Tower. Instruction Manual

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax :

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Light oil / kerosene burner

INSTRUCTION FOR THE USER THC V E OIL BLU

User Manual for model

Infrared Portable Space Heater

Masterflamme Convection Wood Stove

ST E /ST E / ST E / ST E ST E / ST E / ST E

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 200

Electronic Pellet Burner Controller NPBC-V3-1

Boiler regulator ecomax810p3-l TOUCH

1. Contents Principle General information Parts list Assembly Technical drawing... 18

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

Log fired heating system

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Table 1. Serie of Digital Room Thermostats.

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Pioneers of heating with biomasses

DH-Direct Fired Poultry Farm Diesel Heater

Infrared Portable Space Heater

Swedish design and manufacture since 1967

INSTALLATION AND OPERATION MANUAL

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

Homeowner s Installation Instructions & Operating Manual

MCL-BIOMIX. multifuel boiler with mixing mechanism kw FUELS MAIN FEATURES

Operating and installation instructions for Fire Lotus H586

Eco Angus Wood Pellet Boilers

Leading European manufacturer of fireplace stoves and fireplace inserts

Transcription:

HOT AIR WOOD STOVE AIRVENT TECHNICAL DOCUMENTATION V. 1.1

Index 1 TEHCNICAL CHARACTERISTICS... 3 2 GENERAL DESCRIPTION... 3 3 SAFETY DIRECTIONS... 4 4 INSTALLATION DIRECTIONS... 4 4.1 Electrical diagram... 4 5 USE DIRECTIONS... 5 5.1 General directions... 5 5.2 Use of control panel... 5 6 CLEANING AND MAINTENACE... 8 2

1 TEHCNICAL CHARACTERISTICS The Airvent hot air wood stove has advanced design and best quality of construction. It is equipped with fireproof glass. The hot air is delivered by the frontal and lateral blinds of the stove. Main advantages are high efficiency, quick response to heat demand, digital control, and low cost of operation. Technical characteristics Type Airvent 15 Airvent 25 Nominal power kw 15 25 Minimum power kw 7 12 Efficiency % 85 85 Dimensions mm 484x482x1025 546x562x1105 Weight kg 120 150 Chimney mm 150 150 Heated surface m 2 110 150 Fuel Wood-Briquette Wood-Briquette Fuel consumption kg/h 2-3 2-4,5 Air supply m 3 /h 550 700 El. consumption W 50-70 50-70 Voltage V/Hz 230/50 230/50 2 GENERAL DESCRIPTION Legend 1. Chimney 2. Exhaust damper 3,5. Lateral blinds 4,6. Frontal blinds INOX 7. Secondary air setting 8. Primary air setting 9. Door with fireproof glass 10. Ash box 11. Fan 12. Digital control panel 13. Air inlet 3

3 SAFETY DIRECTIONS This device shall not be used by people with lower physical or mental abilities, children, or people without experience. Children should always be supervised not to touch the device. There are hot surfaces that might cause injury! It is recommended not to install the stove on floor made of flammable material. If so, a protective layer of non flammable material, of minimum thickness of 15 mm, should be positioned between the floor and the device. All electrical connections must be performed by an authorized professional. The device must be grounded. Connect the device plug to a grounded inlet. Make sure that the cable is not pressed under the stove or touching any hot surfaces. It is important to use dry wood (humidity 20%), cut at least one year before use, of 40 cm length for Airvent 25 and of 35 cm length for Airvent 15. In case of blackout, stop immediately the combustion by closing the air inlet (7,8) and open completely the exhaust damper (2). If you have a UPS with battery installed, do not add any more fuel in the fire chamber. If no UPS is installed, remove wood from the fire and reduce the fire to minimum possible. 4 INSTALLATION DIRECTIONS Choose the installation area so that the frontal face of the stove is directed to the space you want to be heated. Set the adjustable feet so that the stove is in horizontal position. Make sure the chimney installation is appropriate. Connect tight with the chimney. If there are horizontal parts of the chimney, they should have an inclination of at least 30 o with the floor. 4.1 Electrical diagram 4

Electrical data Voltage Protection Sensor temperature Output Dimensions 230V ± 10% - 50Hz Internal fuse -50 o C 250 o C Fan 230V 200W max. Inserted 120 x 80 x 50 (mm) Norms complying EN60730-1 50081-1 EN60730-1 A1 50081-2 5 USE DIRECTIONS 5.1 General directions Before you put the stove in function check the following: The exhaust damper (2) must be in fully open position. The air inlets (7, 8) must be open. The stove is connected to electricity. The ash box is clean. Add some small pieces of wood in the furnace, and ignite with an appropriate tinder (DO NOT USE gasoline, alcohol or similar flammable liquids) and close the door. If necessary, open a little the ash drawer for some additional air inlet. Add some bigger wood logs, 1-2 every time, without opening the door too fast, to avoid smoke leakage. Do not add too much wood, because it will create excessive smoke and heat. DO NOT USE AS FUEL THE FOLLOWINGS: Wood with moisture or that has been processed Wood shavings Cardboards and paper Plastic or other waste materials Before you clean the ash, make sure there are no burning remains. Even if the ash seems cool, there can still be hot particles in the interior. 5.2 Use of control panel The control panel is already preset for the device. It activates the fan at the temperature of 50 o C and above. 5

In PROP mode, the fan speed modulates according to the sensor temperature; the higher the temperature, the higher the fan speed. If you want to change some parameters (activation temperature, min/max fan speed etc.) you can enter the control panel menu. ON/OFF function Keep pressed the P1 button for ON/OFF function. In OFF mode the lamp L1 will be activated. Mode selection MANUAL: The MAN indication is highlighted. The fan functions at a steady speed, regardless the temperature of the sensor. AUTOMATIC: The AUT indication is highlighted. The fan starts to function at a steady speed when the selected temperature has been reached (SET). PROPORTIONAL: The PROP indication is highlighted. The fan speed is modulated according to the sensor temperature, within the limits (SET SET+dEL). STANDBY: (If Stb=1) If the control panel is set to OFF and the sensor temperature is higher than the tsi value, then the control panel automatically changes to ON function. SECURITY: (If SIC=1 If the sensor temperature is higher than the tsi value and the MANUAL mode is activated at P0, then the control panel switches automatically to PROP mode after 10 seconds. ALARM: (If Enb=1) If the sensor temperature is higher than the tal value, then a sound alarm is activated. This alarm can be deactivated for 5 minutes by pressing any button. After 5 minutes it is reactivated if the temperature is still higher than the safety limit. Main menu Mode selection Press the P4 button for the current mode to appear on screen. By pressing again the P4 button you can cycle through the modes which will appear on screen. The mode is selected automatically after 5 seconds. The L5 led indicates the fan mode. Mode selection Press the P4 button for the current mode to appear on screen. By pressing again the P4 button you can cycle through the modes which will appear on screen. The mode is selected automatically after 5 seconds. The L5 led shows the fan mode. Fan speed selection By pressing the P2 or P3 buttons you can check the current fan speed (P0=OFF at Manual, P1=minimum speed, P10=maximum speed). This function is not available on PROPORTIONAL mode In AUTOMATIC mode the fan speed can be set from P1 to P10. 6

Alarm or Error signals Lo=low temperature (temperature below 0 o C: sensor not connected) Hi=high temperature (temperature higher than 180 o C: sensor short-circuited) ATTENTION: The sensor cable is designed for temperature until 250 o C. It must not come in contact with metallic parts of the stove that have a temperature higher than 250 o C. All electrical connections of the device must be executed by an experienced professional. Make sure there is no voltage when electrical works are executed. Parameters menu To enter the parameters menu keep presses P2 and P3 buttons for 5 seconds. Press the P2 or P3 button to check all the parameters, then press P4 to see the value assigned to each parameter. Afterwards, press again P2 or P3 to change the value. Press P4 to store changes and return to the parameter list. Changes are stored and you exit from the menu after 5 seconds of inactivity. PARAMETERS MENU Parameter Screen Minimum Preset value Maximum Set value Fan activation temperature SET 30 45 99 60 Thermostat hysteresis ist 1 2 35 2 ALARM activation temperature tal 100 120 180 180 SAFETY activation temperature tsi 80 100 140 85 Fan activation temperature at SAFETY mode tsa 100 135 180 135 SAFETY mode SIC 0 (off) 1 (on) 1 (on) 1 Fan activation temperature function at SAFETY mode SAF 0 (off) 0 (off) 1 (on) 0 STANDBY mode Stb 0 (off) 1 (on) 1 (on) 1 ALARM mode Enb 0 (off) 1 (on) 1 (on) 1 Fan speed Ρ01 U01 0 16 100 25 Fan speed Ρ09 U09 0 70 100 70 Fan speed Ρ10 U10 0 100 100 100 Temperature for Proportional mode ( o C) del 20 20 100 50 If the fan must not function in too low speed, you can set the minimum fan speed (parameter UUE): Choose the MANUAL mode. Assign the minimum fan speed to parameter P01. Enter the parameters menu and change the UUE parameter to desired value. Store the changes by pressing the P4 button. Wait 10 seconds to exit the menu. 7

6 CLEANING AND MAINTENACE Once a year it is necessary to clean the stove and the chimney from the ash and dust remains. When you clean the stove have the ash drawer closed. Clean the door glass with a wet cloth or mild cleaners. Do not use active substances. Clean the exterior painted surfaces of the stove with a wet cloth, and not with drastic liquids. 7 WARRANTY The factory warranty for this device is 5 years after purchase, as long as all the regulations and directions of this manual are respected. For all electrical parts warranty is 1 year. If there is any dysfunction or flaw in the device during the warranty period, any repairs will be applied or spare will be provided with no charge. Problems that may occur from wrong use or application of the device, are not covered by warranty. 8