Aspects of Fire Regulations and Standards in the Atrium

Similar documents
First Aspen Federal Regulation Set: K LSC 2000 Health Existing

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

Fire Safety Concept Hotel Jumeirah

ESCAPE WAYS IN RESIDENTIAL BUILDINGS

Smoke Management in High-Rise Structures

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

Unit 2 Fire Safety (Zone 2)

The Singapore Fire Safety Engineering Guidelines. Nicholas Lee, Senior Consultant Fire Safety & Shelter Department Singapore Civil Defence Force

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Date and Time of Incident. March 10, 1975

mcr PROLIGHT, mcr PROLIGHT PLUS

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

NFPA 101 Life Safety Code Culture change 2012

General Principles of Smoke Control

Emergency Evacuation Plan. Tiffany Tower Plot W2 Jumeirah Lakes Towers

Design Guidelines Fire Safety in New and Refurbished Buildings

Vivid Architects were appointed by Rabie Property Group as the lead Urban Designers

COST-EFFECTIVE FIRE-SAFETY RETROFITS FOR CANADIAN GOVERNMENT OFFICE BUILDINGS

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Agency for Health Care Administration

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Fire Risk Assessment

Agency for Health Care Administration

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Chapter 7 Fire Protection

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

Using BIM model for Fire Emergency Evacuation Plan

Emergency Action Plan. Revised: 1/22/2018

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

CHAPTER 7 MECHANICAL VENTILATION AND SMOKE CONTROL SYSTEMS 7.1 AIR CONDITIONING & MECHANICAL VENTILATION SYSTEMS

Agency for Health Care Administration

The following translation is for informative purposes only. The legally binding text is found in the Boverket s Code of Statutes (

Kensington Aldridge Academy, London W10

The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

technical specification smoke venting systems

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Agency for Health Care Administration

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

The Cannabis Industry: Fire Department Requirements

Effects of Smoke on Evacuation Martin Lopušniak 1, a

fire protection glass

I WILL BEGIN BY EXPLAINING THE PROCESS BY WHICH WE MET THE CHALLENGE OF GATHERING PUBLIC INPUT.

Emergency Response Cart Guide

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

Element C3.5 Means of Escape

The Code of Practice for Fire Safety in Buildings 2011 It comprises 7 parts and 1 annex:

Chapter 10. Passive Cooling Contents

Methodist College Emergency Procedures

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Fire safety and high rise student accommodation

Urban Institute for Contemporary Arts

Unit 2 Fire Safety (Zone 1)

Early Warning Fire Detection Engineering

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Some Important Aspects of Fire Safety Regulations about High Rise Buildings

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

Five London Hospital Fires: Report by Philip Gibbs, LFB. For internal training use only.

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS

Product Information October (8) Orivent 51 in Itella, Pennala. Orivent 01 in Oriville factory, Orimattila

Design of Fire safety in Multi Occupancy Residential Accommodation

Agency for Health Care Administration

Ch. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Gothenburg dance hall, Sweden, 1998

Integrated Building Environmental Design Case Study: Beijing Parkview Green

IMPROVEMENT OF THE INDOOR CLIMATE CONDITIONS INSIDE ORTHODOX CHURCHES

1.4 Provide and fix the following ironmongery.

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

Program Summary: A ,000 SF Program Statement: $46.41 $11,000,000 August 2013

Prescriptive Requirement for Smoke Control

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL fpeschulte.

Murray State University Building Coordinator Emergency Procedures. Hollis Franklin College

Certification Assessment Instrument and Guidelines

SECTION INSPECTION AND TESTING OF WORK

A Study on Improvement of Fire Protection Systems based on Failure Characteristics accodrding to Yearly Variation in Old Commercial Buildings

Case Study 1 Underground Car Park

NFPA 45 NFPA 211 NFPA 1600

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Chapter Nursing Homes

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Securing the operational readiness of fire control systems

- CONSTRUCTION FIRE SAFETY STANDARDS

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

Interior signs are an extension of the exterior sign system and their content and design should take this into consideration.

The Unplanned Impacts On Houses By Powered Attic Ventilators

JANSEN BRANDSCHUTZ. Special solutions - Protection without limits

Fire Inspection Program

Transcription:

Transilvania University of Brasov, Romania 13 th INTERNATIONAL CONFERENCE STANDARDIZATION, PROTYPES AND QUALITY: A MEANS OF BALKAN COUNTRIES COLLABORATION Brasov, Romania, November 3-4, 2016 Aspects of Fire Regulations and Standards in the Atrium GRIGOROV Lachezar Technical University of Sofia, Bulgaria, madra_horn@abv.bg TEOFILOVA Marusia Technical University of Sofia, Bulgaria, madra_horn@abv.bg Abstract Fleksibilities of open spaces in modern public buildings, organized by and around large atriums is increasingly sought after in architectural practice. Along with this increase and the requirements for fire safety and timely evacuation. They develop building codes, regulations and standards. Different countries treat problem variant in development, but with a common logic. What is the problem of the large and multi-storey atriums and what similarities and differences in protection of people and property in case of fire in different regions of the world. Various methodologies, technologies and materials. The development of thought and methodology is the development of technology. Examples of author and world practice. Specific features of local standards for fire safety and evacuation. A brief overview of the development of thinking on the issue. Keywords atrium, fire regulations, evacuation, architecture, fleksibility The theme is developed based on built in 2007-2010 year BBC building located on the boulevard Tsarigradsko Shosse in the town Sofia. The main parameters are: 32,000 m 2 footprint area, 16 floors, 66 meters high. Immediately from the main entrance people pass to the atrium area of 220 m 2 and passing through the entire height of the building in the 14th levels to elevation 53.45 meters. At the rear there second and third small atriums in 5 levels. The research team is led by Arch. S. Dobrev with the participation of Arch. L. Grigorov - the report's author and architect D. Paz. - 2006-2007 years, Figures 1, 2, 3, 4, 5, 6. Existing main regulations (in Bulgaria) about atrium spaces now are: Atrium buildings Art. 304. (1) In building with an atrium, inclusive three or more floor levels, subject to these requirements. (2) Not allowed to design atriums in hospitals and outpatient care in medical centers, diagnostic and consultative centers, hospices and others. Similar buildings with residents who need medical care. Art. 305. (1) The buildings with an atrium designed by I or II degree of fire resistance. (2) Wall, ceilings and floors in the volume of the atrium and involve him space constructed by building materials of reaction to fire no lower than A1 or A2 (A1FL or A2fl). Art. 306. (1) The bearing roof over the atrium is performed with fire resistance of at least R 30. (2) Glazing and other transparent coatings in the roof of the atrium are provided with class reaction to fire A1 or A2. (3) Products for window frames on the facades of the atrium and facilities to create shade is of reaction to fire not less than C. Art. 307. (1) Glazing and other transparent coatings in the roof of the atrium are provided with class reaction to fire A1 or A2. (2) For the glazing of staircases and panoramic elevators Atrium using fire resistant matte with fire resistance of EI 30. Art. 308. The maximum distance from any of the locations in the atrium at the entrance to evacuation staircase or the final evacuation exit should not exceed 20 m for the text exceeds the 182

character limit. One-way evacuation routes and 40 m at two or more routes, taking into account the requirements of this atrium. Art. 309. Atriums are designed so that they are directly accessible from the outside in hallways or lobbies. Art. 310. (1) For protection from uncontrolled spread of smoke and heat in buildings with an atrium designed systems to remove smoke and heat as follows: 1. natural ventilators Smoke and heat (EVDT) - smoke vents located in the cover of the atrium or directly below it, and openings for air intake and for equalization of pressures at the base of the atrium that have at least the same size; or 2. mechanical ventilation to differentiate pressures fire in the atrium and adjacent areas. (2) Systems to remove smoke and heat are controlled manually - remote and in buildings with automatic fire detection and extinguishing systems - and them. Art. 311 (1) Securing atriums in case of fire, depending on the class of functional fire-hazard construction, the height of the atrium and the type of separating the atrium from the adjacent floor areas to provide the following technical solutions: 1. automatic fire alarm system in the adjacent atrium floors in the atrium; 2. the automatic firefighting system in the adjacent atrium floor; 3. smoke hatch on top of the atrium area equal to 10 % of the area's largest atrium opening in the inter-floor structures; 4. mechanical ventilation to remove smoke and heat volume atrium, sized according to EN 12101, Part 10; 5. shaping flue reservoir on top of the atrium; 6. systems for voice notification in construction; 7. controlled combustible load at the base of the atrium. (2) The specific technical solutions for securing atriums in case of fire are given in Annex 9. At the time of the design of that building these standards did not exist yet. The design team examined the existing rules in Europe, Britain and the USA. Mainly based on the European standards which are not saying that something be impossible to buil, but gave an algorithm in which to solve the problem. Bulgarian fire services have adopted this concept and approved the project. This project served as a precedent and subsequently the subject of multi-storey atriums entered as a separate chapter in the new fire regulations and standards in Bulgaria. Later a report carried by a representative of German fire services had commented in their opinion that the current fire regulations and standards in Bulgaria are probably the most restrictive in the world now. How things were solved in our building? A major problem was the decision of Architects have open atrium spaces at all levels. This meant that the appearance of fire somewhere on the floors choking smoke could penetrate virtually anywhere. The decision vklyuchvasha several components: 1. Glass partitions that hang suspended from the ceiling to a height of 210 cm above the floor. Thus formed fume-exhauset baskets below the level of the suspended ceiling. 2. From there fume exhaust system sucks the smoke and took him to the roof. 3. Of course the whole building is armed with a fire alarm system. 4. Fight it selectively only for sites reported. Thus isolating the damage in case of fire due to firefighting. 5. Carefully calculated all locations and design of evacuation routes and exits. 6. Avoided are combustible materials. Decisions on smaller atriums - smaller as the number of floors are organized in other ways and requirements are a little lighter. Typical cases are the numerous built everywhere multifunctional shopping centers. High requirements are oriented multi-storey atriums - over 5 floors. Characteristic research example is hanging from the ceiling glass partitions organizing the collection of lighter than air smoke before discharging him out of the building. Another easier solution is practiced as isolated interior spaces of the building atrium walls through the entire height of the floor which completely isolate the possible infiltration of smoke from the atrium to the offices or retail space. We are tempted to quote and show the famous 33-storey atrium in Jin Mao Tower, which is below the ceiling of 55 floor. 183

Fig. 1. BBC building Fig. 2. BBC building 184

Fig. 3. BBC Main section Fig. 4. BBC Evacuation through atrium space under doom 185

Fig. 5. BBC The view of atrium from down to up Fig. 6. BBC Level 3 186

In this example, it applied the rule to totally isolate the working and residential zones of the space of the atrium through walls. The main atrium between axes: 8 and 10 and elevation of 0.00 to 53.45. Small atriums between axes: 3 and 5. Fume in the space between the double roof - Figures 1 and 2. In the basement level -2 is provided water tanks for fire extinguishing. In the atrium space under a glass dome cross three bridges carrying out evacuation staircase to the second - level 13 and level 14. Elevators are panoramic and their route passes through the atrium volume. The main facade is shaped by double-skin facade system. Rear roof areas are gardens and roof of the lower body, as evidenced by Figures 1 and 2. Remark Used original photos and drawings in the preparation of which took part the author of the report. 187