Aquamatic Instantaneous DHW production unit with integrated storage tank

Similar documents
AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

Introduction...from 3 to 4 Tanks for the production and storage of DHW. Domestic use....from to 8 Tanks for the production and storage of DHW. Industr

CRIMSON & CRIMSON MAX

Gasketed and brazed plate heat exchangers

Solar heating systems

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

white blue cobalt bordeaux light oak (rovere)

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

LZT High efficiency air to water heat pumps with E.V.I. compressors

Hydronic & HVAC Control Systems

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

1 VICTRIX ZEUS Superior kw I features

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

STILE BEAUTY AND TECHNOLOGY

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Better Design, Better Control, Better Systems.

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

LZA High efficiency air to water heat pumps with HP compressor

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

D O M E S T I C Solar Thermal

Installation, Operating and Servicing Instructions

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Water chillers water/water type SIGMA Technical information manual

Condensing, pre-mixed, wall-hung gas boilers with water tank

S SOLAR RANGE

International Markets. Product Catalogue. complementary items

PAC BT LOW TEMPERATURE HEAT PUMP

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

PRODUCT GUIDE

PACK QUATTRO 06 16T INVERTER Split air / water inverter heat pump to produce heating, air conditioning and domestic hot water for small / medium users

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Installation, Operating and Servicing Instructions

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Exclusive Green E Condensing Wall-Hung Boilers

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

Planning guide. (2010/09) en

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Hydronic Mechanical Panels

WZH Ground source heat pumps

October Solar Thermal

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

SPECIFICATIONS - NIKE

Blue Box Epsilon Echos +

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Energy-efficient heat source provides comfort in large rooms

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

INDEPENDENT DOMESTIC CALORIFIERS

Power X High Power Condensing Wall-Hung Boilers

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

WATER HEATERS Range of Products. Everyday comfort.

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Solar water heating system

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

kw COOLING kw HEATING

EWM 1000 COMPONENT FUNCTIONALITY

Ultimate energy saving technology

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

C Tahiti. condensing

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

ECOplus Solar Cylinder

CASSETTE UNIT. Comfort Circle

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Constant climate chambers

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Transcription:

Aquamatic Instantaneous DHW production unit with integrated storage tank The Aquamatic is an innovative plug and play system, which unites both the functions of an inertial tank and an instantaneous DHW production unit in one system. The Aquamatic is elegant and has an original design. Suitable for heating installations powered by one or more energy sources (traditional water heater, heat pump, biomass water heater, solar thermal ). The device guarantees the inertial storage of technical water and at the same time, the instantaneous production of domestic hot water at the temperature set by the user and with limited chalk formation. The thermal exchange is carried out through the AISI 31 stainless steel plate heat exchanger, which guarantees hygiene and elevated performances. The heat exchanger is integrated with the storage tank from which it takes energy. The system consists of all components necessary for functioning and can be monitored through a control unit with graphic display. The heart of the Aquamatic system is the particular electronic regulation, developed by Fiorini, which guarantees that the DHW temperature set through the modulation of the primary circuit flow will be reached and maintained. In this way, there is: A high thermal increase on the primary circuit in order to optimize the efficiency of the generator (heat pump; solar thermal; biomass, etc.) Precise and trustworthy regulation Thanks to the highly efficient thermal exchange system the unitis the ideal solution for devices with single or double use in residential or commercial installations that are supplied by a heat pump and/or solar panels and that use a low temperature thermal storage tank (0- C). 1 www.fiorinigroup.it

Aquamatic Main features Highly efficient heat exchange system with discontinuous or low temperature generator Cheap and user-friendly Efficient even with a low flow rate (min l/min) Highly hygienic with antilegionella function Very precise temperature control Highly efficient circulation pump (in accordance with the 00/3 CE directive) and electronic management of the number of runs. Graphic display which indicated the temperature in the device and the power Saves space compared to the solution with heat exchanger + storage tank Easy installation, Plug and Play system High density rigid polyurethane insulation. Low thermal loss, energy class B Monobloc structure with original, captivating and esthetical design, which make the device like a piece of furniture. All-in integration with other generators (for the version that have one) Possibility to integrate and manage accessories in kit: Integrative electrical resistor Domestic recirculation pump Installation in series Mixing valve for temperature control on the primary circuit. Deviation valve for stratification Additional inertial tank for installation; integrated solar unit Connectivity (accessory in kit): Possibility to check and monitor the system via internet Possibility to communicate with monitoring systems with the Modbus protocol FAST HEATER AND FWS 3 1 1 Storage tank Coil (SOLAR and PLUS versions) 3 DHW exchanger flow/temp gauge electric board electronic regulator circulation pump www.fiorinigroup.it 1

Available versions The AQUAMATIC system is available with three different storage capacities and in three different versions. The versions differ in the presence of a second heat exchanger for additional sources and in the possibility of managing the additional heat source through an electronic pump and the specially programmed software. Aquamatic: tank supplied with a single energy source. Equipped with plate heat exchanger for instantaneous DHW production, high-efficiency circulator and electronic board Aquamatic Plus: tank with additional coil for adding an integrative heat source Aquamatic Solar: Tank for use and management of an integrative heat source (solar thermal, water heater, etc.); next to an additional coil, there is also a circulator and control software for managing the integrative source. Next to those three devices, an integrative resistor is also available, which can meet the highest heat requirements. code description pump primary exchanger primary electronic control 8030X AQUAMATIC 00 8030X AQUAMATIC 300 8030X AQUAMATIC 00 exchanger integrative recirculation pump integr. 8030X AQUAMATIC Plus 300 80308X AQUAMATIC Plus 00 8030X AQUAMATIC Solar 300 80301X AQUAMATIC Solar 00 The AQUAMATIC is delivered packed in a cardboard box on a pallet. It has an electric cable with SHUCO plug, length 1. m. 18 www.fiorinigroup.it

Technical information AQUAMATIC 00 300 00 Electrical supply V/Ph/Hz 30/1/0 Absorbed power min/max W / Absorbed current min/max A 0,1/0,3 Absorbed power min/max Solar version W /1 Absorbed current min/max Solar version A 0,18/1,0 Min DHW flow rate at start-up l/min Max DHW flow rate l/min 3 Max operating pressure bar Max operating temperature C Capacity of the tank l 1 0 80 Deliverable flow rate* l/m 18, 18, 18, Deliverable liters* l 13 1 33 Empty weight kg 8 11 Empty weight Plus version kg - 131 Empty weight Solar version kg - 1 13 FAST HEATER AND FWS Surface area Integr Heat exchanger (Plus and Solar versions) m - 1, 1, Sound pressure at 1 m db(a) Heat loss ** W 8 80 Energy class B B B Electronic regulation of the pump velocity Graphic display Settings for DHW temperature Possibility to set antilegionella treatments *Working conditions in accordance with EN 11 (DHW C, tank 0 C) **Working conditions in accordance with UE N. 81/013 and N.81/013 (ambient air 0 C, tank C) www.fiorinigroup.it 1

Performance Aquamatic Quantity of domestic water produced in l/m with different storage temperatures and different outlet temperatures 0 Primary temperature C 0 0 3 30 0 1 0 30 3 0 T out 0 C T out C T out C T out 8 C l/m Deliverable DHW flow in function of the storage temperature fluctuations and the various outlet temperatures (can be set as setpoint for domestic hot water) Inlet temperature domestic C For example, if Taccumulo = C And TDHW = C, the AQUAMATIC guarantees a flow of approximately 1 l/min And TDHW = C, the AQUAMATIC guarantees a flow of approximately l/min www.fiorinigroup.it

Performance Aquamatic l 00 00 00 00 300 00 Generator 8 kw Quantity of domestic water produced (in liter) for the different tank capacities, with outlet temperature at C and generator in function. The graphic show the variation in the quantity of DHW produced in function of the various storage temperatures upon the variation of the power emitted by the generator. 0 0 0 0 80 800 00 Generator 1 kw C l 00 00 FAST HEATER AND FWS 00 300 00 0 0 0 0 80 C 0 Generator 1 kw 80 0 0 l 0 0 30 0 0 0 0 80 Aquamatc 00 Aquamatc 300 aquamatc 00 C For example with an AQUAMATIC of 300 l with a 1 kw heat pump If T TANK = C, the AQUAMATIC 300 guarantees approximately 330 liters of DHW at C If T TANK = 0 C, the AQUAMATIC 300 guarantees approximately 380 liters of DHW at C www.fiorinigroup.it 11

Performance Aquamatic Output in kw of the additional heat exchanger in fucntion of the variation of the value ΔT between the temperature of the integrative source and the storage temperatore. Only for AQUAMATIC PLUS and AQUAMATIC SOLAR. Output in kw of the additional heat exchanger 0 3 30 0 1 0 0 1 0 30 3 0 Aquamatic AQUAMATIC 300 serpentino coil 1, m 1, mq aquamatic AQUAMATIC 00 00 serpentino coil 1, m da 1, mq For example, if Taverage in tank = 30 C Suppose the integrative coil is supplied with water at a temperature of 0 C (inlet) and that water cools to 0 C (outlet). We can consider an average temperature on the integrative circuit of 0 C. As such, we can refer to an indicative average DT of 0-30 = 0 K In this case the performance of the additional heat exchangers would be: AQUAMATIC 300: 1 kw on average AQUAMATIC 00: 0 kw on average ΔT : temperature difference between the average temperatures in the primary circuit (coil) and secondary circuit (tank). Pressure loss in integrative coils and characteristic graphic of solar circulator Pressure loss Prevalence (mca) 8 3 1 0 0 0 00 0 00 0 000 Aquama1c AQUAMATIC 300 300 perdita di carico serpen1no in m.c.a. Aquama1c AQUAMATIC 00 00 perdita di carico serpen1no in m.c.a. Water flow (liters/h) Curva SOLAR circolatore PUMP solare 1 www.fiorinigroup.it

Dimensions Aquamatic Coupling chart N description AQUAMATIC 00 AQUAMATIC 300 AQUAMATIC 00 1 Inlet/outlet domestic circuit 3/ 3/ 3/ Inlet/outlet primary circuit 1 1 1 1/ 3 Inlet/outlet auxiliary circuit - - 1 1/ Electrical resistor 1 1/ 1 1/ 1 1/ FAST HEATER AND FWS Inlet/outlet device 1 1 1 1/ 8 Inlet/outlet auxiliary device - - 1 1/ Coupling kit with deviation valve for stratification 1 1 1 1/ Inlet resistor cable GUAINA D. 0 GUAINA D. 0 GUAINA D. 0 11 Inlet probe 1/ 1/ 1/ Heights chart description A B C D E F G H I L M N O P Q R AQUAMATIC 00 131-0 - 80-1, - 80 1 0 AQUAMATIC 300 10-0 - 11-0 - 11 110 13 AQUAMATIC 00 80 80 30 80 83 30 1180 80 30 30 30 1180 130 13 880 www.fiorinigroup.it 13

Dimensions Aquamatic Plus Coupling chart N description AQUAMATIC 300 AQUAMATIC 00 1 Inlet/outlet domestic circuit 3/ 3/ Inlet/outlet primary circuit 1 1 1/ 3 Inlet/outlet auxiliary circuit / 1 1/ Temperature probe 1/ 1/ Inlet/outlet solar circuit 1 1 Electrical resistor 1 1/ 1 1/ Inlet/outlet device 1 1 1/ 8 Inlet/outlet auxiliary device / 1 1/ Coupling kit with deviation valve for stratification 1 1 1/ Inlet resistor cable GUAINA D. 0 GUAINA D. 0 11 Inlet probe 1/ 1/ Heights chart description A B C D E F G H I L M N O P Q R S T U AQUAMATIC "PLUS" 300 10 3 / 8 0 / 11 / 0 / 11 10 13 0 AQUAMATIC PLUS 00 80 380 80 80 30 1180 80 30 30 30 1180 130 13 80 0 0 880 1 www.fiorinigroup.it

Dimensions Aquamatic Solar Coupling chart N description AQUAMATIC 300 AQUAMATIC 00 1 Inlet/outlet domestic circuit 3/ 3/ Inlet/outlet primary circuit 1 1 1/ 3 Inlet/outlet auxiliary circuit / 1 1/ FAST HEATER AND FWS Temperature probe 1/ 1/ Inlet/outlet solar circuit 1 1 Electrical resistor 1 1/ 1 1/ Inlet/outlet device 1 1 1/ 8 Inlet/outlet auxiliary device / 1 1/ Coupling kit with deviation valve for stratification 1 1 1/ Inlet resistor cable GUAINA D. 0 GUAINA D. 0 11 Inlet probe 1/ 1/ Heights chart description A B C D E F G H I L M N O P Q R S T U AQUAMATIC "Solar" 300 10 / 81 / 11 / 0 / 11 10 13 13 8 3 0 AQUAMATIC Solar 00 80 80 30 88 883 30 1180 80 30 30 30 1180 130 13 13 88 30 880 www.fiorinigroup.it 1

Installation chart Aquamatic 3 1 8 11 Description components 1 Filter Manometer 3 Safety valve Ball valve Deviation valve stratification (accessory) expansion vessel pump 8 mixing valve device low temperature. filling valve discharge 11 radiant system 1 www.fiorinigroup.it

Installation chart Aquamatic Plus Example 1 3 1 8 11 1 3 FAST HEATER AND FWS Description components 1 Filter Manometer 3 Safety valve Ball valve Deviation valve stratification (accessory) expansion vessel pump 8 mixing valve device low temperature. filling valve discharge 11 radiant system 1 closed fireplace or thermostove www.fiorinigroup.it 1

Installation chart Aquamatic Plus Example 13 3 1 8 1 1 Description components 1 Filter Manometer 3 Safety valve Ball valve Deviation valve stratification (accessory) expansion vessel pump 8 mixing valve device low temperature. filling valve discharge 11 radiant system 1 solar collector 13 vent 1 solar station 18 www.fiorinigroup.it 11

Installation chart Aquamatic Solar 13 3 1 3 1 8 11 FAST HEATER AND FWS Description components 1 Filter Manometer 3 Safety valve Ball valve Deviation valve stratification (accessory) expansion vessel pump 8 mixing valve device low temperature. filling valve discharge 11 radiant system 1 solar collector 13 vent www.fiorinigroup.it 1

Accessories on demand Several kits with accessories that can be connected to the AQUAMATIC are available. Some of those can be supplied already assembled in our factory. Kit Electrical Resistor The kit with an electrical resistor (integrated) guarantees the a constant storage temperature, even in case of insufficient energy supply by the primary heat source. The resistor can be managed directly by the Aquamatic control unit, simply by activating it through the display. The kit can be assembled in our factory or supplied after delivery. It contains: 0 W single-phased 30 V electrical resistor with regulation thermostate fuses and wiring for integration in the electrical switchboard NB The AQUAMATIC has a small channel through the insulation of the tank in order to pass the cable for connecting the resistor to the electronic switchboard. RIF Description components 1 Electrical resistor Resistor cable 3 Inlet channel for cable Outlet channel for cable Cable gland for fixing the cable Fuse holder and precabled relay 180 www.fiorinigroup.it

Kit mixing valve on primary circuit The kit with mixing valve (integrated) makes it possible to regulate the inlet temperature of the domestic heat exchanger. In this way, especially in installations that can reach high temperatures in the primary circuit, the precision of the regulation of the production unit improves. This leads to a larger comfort and reduces the chalk formation in the domestic circuit. We recommend the use of this device when the temperature in the primary circuit teaches values higher than 0 C. The kit can either be pre-assembled in our factory or supplied later on. It contains: DN0 three way mixing valve Servo drive Vac/dc Signal 0. V kit with tubes for installing the kit to the top part of the AQUAMATIC temperature probe Pre-cabled gudgeon pin for connection to the electric switchboard Outlet hot water Inlet cold water 1 FAST HEATER AND FWS B A AB 3 Functional chart 1 Flowmeter Domestic plate heat exchanger 3 Primary mixing valve Pump Tank www.fiorinigroup.it 181

Kit for connecting the Aquamatic in series The kit for connecting the Aquamatic in series is the solution for all applications in which the demand for DHW is highly variable. In this way, it is possible to connect up to instantaneous production units and guarantee a DHW production of l/min up to more than l/min*. The electronic control units of every instantaneous production unit are able to communicate with each other (setting in the set-up menu). The electronics decides how many and which production unit have to be started up in function of the user conditions. *Conditions of reference T STORAGE TANK = C T DHW = C Advantages and benefits: Trustworthiness. Thanks to the self-diagnosis by the control unit, in case of malfunctioning of a production unit, the device is automatically deactivated and another production unit is started up. In this way, the continuous production of DHW is guaranteed. The regulation of the temperature is even more precise. The regulation makes it possible to activate the right number of production units based on the required flow and temperature of the DHW. In this way, every production unit always runs on the conditions closest to the nominal conditions, which improves the efficiency and precision of the regulation. The system with several production units connected in series can be expanded by adding other units (also later). Possibility to execute the programmed maintenance on the production units without interrupting the DHW production. Every production unit runs for an equal number of hours, which guarantees a longer life span of the system. Contains: DN0 two-way zone valve Three point servo drive 30 V kit with connections 18 www.fiorinigroup.it

Kit External deviation valve for stratification The kit with external deviation valve makes it possible to take the water for the return to the heat pump from the lower parts of the tanks instead of the middle in function of the temperature difference between the two zones in the tank. In this way the temperature of the water that returns to the heat pump makes it possible to produce hot water at a higher temperature than the storage temperature. This maximizes the efficiency of the entire heating installation. N.B. In case of connection in series, you should provide a deviation valve kit for every AQUAMATIC. Contains: DN3 three-way valve On/off servo drive 30V FAST HEATER AND FWS RIF Description 1 Manometer Safety valve 3 Ball valve Deviation kit Expansion vessel Recirculation pump (source) www.fiorinigroup.it 183

Recirculation kit The recirculation kit makes it possible to check the pump of the domestic recirculation circuit (circulator not supplied). Possible settings: Programming the recirculation in time slots Programming the recirculation based on the temperature of the recirculation ring. Programming the recirculation based on a combinations of the two above-mentioned settings Recirculation pump always running. The kit is supplied separately and not assembled. It contains: Temperature probe to be put on the recirculation ring Instructions Recirculation pump The recirculation pump is not supplied with the kit because the device has to be selected based on the specifics of the installation. However, because it is controlled by the regulator of the Aquamatic group, it has to have the following features Power supply 30V/0hz/1ph Max absorption 00 W RIF Description 1 safety valve expansion vessel 3 ball valve pump non-return valve bt recirculation probe Kit serial port RS8 Modbus Makes it possible to communicate with the supervision systems through the Modbus protocol Kit web (remote control) Makes it possible to check and monitor the device via internet 18 www.fiorinigroup.it

Solar unit without pump for AQUAMATIC SOLAR Solar unit with double tube to couple with the AQUAMATIC SOLAR when a pre-assembled solar station is needed that integrates and completes the functions already present in the AQUAMATIC SOLAR. The solar unit with double tube, completely assembled and tested, consists of: Return circuit: Flow meter and regulator with couplings for the filling and emptying of the installation Ball valve with non-return valve which can be excluded by turning the handle with (useful in the filling phase of the installation) bar safety valve with manometer Ø0 mm 0- bar and discharge outlet ¾ F coupling for expansion vessel ¾ M Thermometer 0- C Flow circuit: Ball valve with non-return valve which can be excluded by turning the handle with (useful in the filling phase of the installation) Thermometer 0- C Brass deaerator with manual vent valve Connecting hose and coupling FAST HEATER AND FWS www.fiorinigroup.it 18

Accessory storage tank for installation A tank that can be put onder the AQUAMATIC when you need an inertial flywheel dedicated exclusively to the heating installation of cool water installation. Reccommended in all case in which you have a heat pump as thermal source. Its installation makes it possible for the heat pump to operate at a low temperature when it has to reach the thermal demand of the installation. In this way the operation at high temperature is limited to the production of domestic hot water. Moreover, the tank serves as a thermal flywheel in summer mode in order to guarantee an optimal modulation of the heat pump. Energetic efficiency Easy installation Does not take a lot of space Same design as the AQUAMATIC In carbon steel without internal treatments of the surface area, insulated with 30 mm thick rigid polyurethane, externally covered in thick coloured PVC. Two available capacities in function of the size of the selected AQUAMATIC. Supplied with manual air vent valve and coupling for probe pit. Material: carbon steel insulation: 30 mm thick rigid foam external covering: coloured PVC User limitations Min temperature - C Max temperature C Max pressure 3 bar Legend Rif. Description 1 1 flow heat pump F G return heat pump 3 probe 3 return installation flow installation E C D B vent Chart with dimensions and couplings Cod. Capacity Ø B C D E F G 1 3 818X 0 1 130 0 1 1 1/ 1 1 1/ 81X 3 80 0 1 130 0 1 1/ 1 1/ 1/ 1 1/ 1 1/ 1 1/ 18 www.fiorinigroup.it

Installation chart accessory 11 1 3 8 13 1 1 FAST HEATER AND FWS 11 1 1 3 8 8 13 1 1 Legend Rif. Description 1 Heat pump pump 3 deviation valve domestic/installation vent ball valve fill-up valve safety valve 8 expansion vessel Rif. Description discharge valve Manometer 11 Aquamatic 1 inertial puffer 13 mixing valve installation low temperature 1 radiant installation 1 solar collector www.fiorinigroup.it 18

Codes AQUAMATIC code description price 8030X AQUAMATIC 00 8030X AQUAMATIC 300 8030X AQUAMATIC 00 Packed dimensions cm weight kg code description price 8030X AQUAMATIC Plus 300 80308X AQUAMATIC Plus 00 Packed dimensions cm weight kg code description price 8030X AQUAMATIC Solar 300 80301X AQUAMATIC Solar 00 Packed dimensions cm weight kg Kit accessori code description price 80000X 803011X 803011X 8030X 803011X Kit resistor Kit internal primary mixing valve Kit in series Kit external deviation valve for stratification Kit recirculation pump 818X Accessory puffer 0 liters AQUAMATIC 00/300 81X Accessory puffer 0 liters AQUAMATIC 00 83810X Solar station no pump 00 Kit serial port RS8 000 Kit web (remote control) 188 www.fiorinigroup.it