Adam Monaghan BSc (Hons) CEng MIFireE

Similar documents
SHAPING A BETTER WORLD. Innovations in Buildings and Fire Safety Provisions Pierre Gaston and Neil Hitchen - Arup Friday 12 th October

Are we using the wrong design fires for tall building fire strategies, in light of recent full height fires?

Historic Environment Scotland

AILA CPD TREE OF KNOWLEDGE DESIGNING AND CONSTRUCTING

Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC. Compliance to IEC means more than just Pfd!

Enclosures Appendix 1: Draft Golders Green Station Planning Brief. Summary

Management of installed safety instrumented systems (SIS)

Fire Engineering in High Rise 15 November 2013

Why should getting a Fire Risk Assessment right be a vital management policy?

Loss Prevention Standards

NFPA 101 SAF-AXM PUBLIC COMMENTS

Fire Investigation

Prescription of qualifications. ARB Criteria at Part 2

A wood heater that s right for every home! THE FLAME OF THE FUTURE

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

For Building Managers: outsourcing the maintenance of fire safety and security systems

SCACT Paddock Garden STC Monday 10 April 2017

Shelter submission to the DCLG review of the Smoke and Carbon Monoxide Alarm (England) Regulations 2015

Certain Uncertainty - Demonstrating safety in fire engineering design and the need for safety targets.

The Art of Building a Garden City: New Communities for the C21st

Institute Response to Design Guidelines: Design Quality and Housing Choice

Ultimate Security Provider

Landscape Architecture & Urban Design

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

CIDA Curriculum Matrix - Miami University First Year

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

Reducing the Distance to Integrate: DTE Energy use of CIM at the ESB

The Question. Building Regulations Sympathetic Interventions in the Care of Heritage Buildings Toby McCorry CEng, Beng, FDSc, MIFireE

Relentless efficiency. Real savings.

LANDSCAPE INSTITUTE CORPORATE STRATEGY ISSUED 3RD APRIL Landscape Institute 107 Grays Inn Road London WC1X 8TZ United Kingdom

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

Three Pathways for Urban Change - Utilising planners and architects to realise the New Urban Agenda

Heritage in Neighbourhood Plans

Advisory Brief to Prince George City Council On the Matter of Bylaw 8727, 2013, Fire Protection and Emergency Response Bylaw

New Approach to Design Urban Landscape Developing More Sustainable and dynamic Urban Landscape In Iran And Other Arid & Semi Arid Climates

2017 CIDA Standards Infused into Undergraduate Courses

Home Improvement Sector Commitment ( )

A proposal for using the potentials of citizen science programmes in urban bird. studies. Dhanya R*, Ranjini J and P A Azeez

Services. Monitoring. t f e. w.

Exhibition of Oran Park and Turner Road Precincts

The Hadean-Creation studio.

WOKING DESIGN SUPPLEMENTARY PLANNING DOCUMENT (SPD)

HEALTH, ENVIRONMENT AND SAFETY MANAGEMENT FOR FACILITIES MANAGERS COURSE OUTLINE

FIRE SAFETY MANAGEMENT PLAN

MLA Learning Objectives : Competency Areas by Course Dept. of Landscape Architecture and Environmental Planning

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ENGINEER AND THE TECHNICIAN DESIGNING FIRE PROTECTION SYSTEMS.

ORGANIC EDIBLE & NATIVE LANDSCAPING

Proposed Social Housing (Automatic Fire Suppression Systems) (Scotland) Bill Shelter Scotland consultation response

Syllabus Permaculture Design, Winter

THE FUTURE STATE OF LANDSCAPE

Electrical Safety Policy

Over 500,000 of work won by Cornish construction firms

FIRE SAFETY POLICY. Approval Approved by: University Court Date: March 28 th 2017

Standards: Issues and Challenges

Managing Fire Safety To Ensure Legislative Compliance

Harlequin HeatStream Case Study

auditorium seating collection

CDID Building Maintenance LLC is a limited liability company that provides soft furnishings services to customers across the U.A.E.

G4S SRI Update. September 2013

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

Implementing sustainable water strategy through development industry engagement

Barbour Webinar Monday 16 th September 2013

Extension of Registered Gas Installer Scheme to include Non-Domestic Gas Works

Can You Swim? Developing Sustainable Buildings

BS 7913 Launch event. 10 March 2014 Somerset House, London

Doors that not only act as a barrier, but enhance the look and character of your home.

Awarding body monitoring report for: Institute of Legal Executives (ILEX) February 2008 QCA/08/3734

SPC GUIDE NAAB 2014 STUDENT PERFORMANCE CRITERIA School of Architecture - University of Arizona NAAB SCHOOL OF ARCHITECTURE

In addition, Fire Protection and Business Support Information are included in the report.

THE SCOTTISH PARLIAMENT PLANNED FIRE EVACUATION EXERCISE: 12 DECEMBER 2008 EXERCISE REPORT

Principles of Recreation Resource Planning

Writtle University College Policy & Principles for Sustainable Development

Memorials, Plaques & Interpretive Signs Policy

BUSHFIRE THREAT ASSESSMENT REPORT. Special Fire Protection Purpose Development. North Byron Beach Resort. Proposed Central Facilities

The Old Royal High School, Edinburgh Public Discussion organised by the Architectural Heritage Society of Scotland 23 rd February 2015

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

ARCHITECTURE PROCUREMENT SUSTAINABILITY

A Gateway to Safety The New Powered Gates Certification Scheme

Response to call for evidence for Independent Review of Building Regulations and Fire Safety. October 2017

Pre-seen case study for Strategic level examinations Papers E3, P3 and F3. For examinations in May 2014 and September 2014

response sent to: Dear Sir/Madam Response to: The Review of Designated Landscapes in Wales Stage 2

EDC 016/004 Annex A. Framework Masterplan Stakeholder and public engagement

BUSINESS PLAN CEN/TC 79 RESPIRATORY PROTECTIVE DEVICES EXECUTIVE SUMMARY

NAME : HARRY BANIASADIPOUR ARCHITECTURE #

Implementing Water Sensitive Urban Design: Opportunities, Challenges and Limitations. The Case of Victoria

Rural Environment and Conservation

The Gas Safety (Installations and Use) Regulations 1998.

CCTV, HOW DOES IT WORK?

Integrating LEED ND & SITES Into Your Design Approach

SCHULTE & ASSOCIATES Building Code Consultants 3500 Creighton Road, K5 Pensacola, FL

European Standards: Supporting the European Single Market for Services

Statutory Compliance Checklist

Energy Efficiency. Intercept HDDperDay <2e 16 kwhperday

FIRM PROFILE & EXPERIENCE / MICHAEL MALTZAN ARCHITECTURE

Prof. Alex Torpiano University of Malta

events NeoCon East 2016 Preview by Mallory Jindra

Stewardship. Streamlining. Consensus

Energy Saving Fact Sheet Agriculture & Horticulture

Transcription:

Adam Monaghan BSc (Hons) CEng MIFireE Associate Director Arup Image Birmingham New Street Arup

\ Contents Why am I here? Ove Arup and Total Architecture Total Fire Engineering Examples Image. Sir Ove Arup Arup

Fire Engineers only help in design \ The status-quo Legal case prevalence faulty fire safety design/construction Perception of fire engineers as cost cutters Paucity of understanding responsibility and liability of fire safety designs

Accountability \ Fire Engineering Project Management Who is competent? Approvals / Self-Certification Responsibility- Legal & PI We need a fire engineer to get rid of sprinklers Codes vs Engineering Perceptions and Practice

Perceptions a design is either prescriptive or fire engineered? OR

Perceptions a design is either prescriptive or fire engineered? OR Its all fire engineering competence Code compliance is no safety guarantee

Required for ethical practice of fire engineering project management \ Competency What qualification/experience does a fire engineer actually need? Conflicts of interest in assessing competency of solutions Designer vs Approver Design, specification, construction, handover, operation

It s okay because it has been signed off by Building Control \ Responsibility We ve done this previously and it was okay Legal responsibility for adequacy of design rests with the designer, not the approver. The product brochure says it s got the right performance

Either remain silent + perpetuate the status quo Or

Either remain silent + perpetuate the status quo Or TIME TO PUT UP OR SHUT UP

I am proud of my profession \ My reasons I am not a cost-cutter I enable design I achieve goals for my clients I take my job seriously I will not compromise rigor when money is tight I take my responsibility seriously

Total Fire Engineering - Papers #1 Competency in Fire Engineering January 14 #2 Code vs Engineering April 14 #3 Shouldering Responsibility July 14 #4 Have you got time? October 14

Image The Shard Arup The domain Fire Engineers operate present serious challenges to competent and ethical practice that cannot be ignored.

We have to identify, debate, and respond to challenges that face our fire engineering profession Image Castle Donnington M&S Logistics

Image Ben Sutherland We need to change and challenge this status quo

. The fire engineer needs a certain toughness and I am referring to intellectual toughness. The engineer must be able to be tested, challenged and deal with matters in a rigorous, analytical and above all honest way. He must be aware of the rules but not use them as a shield.. Any rules need to have an engineering basis and be goal related: the purpose of which needs to be understood by both researchers and regulators. The magic numbers embodied in regulations are accepted without any question whilst any engineering solution is subjected to a disproportionately high standard of proof Image. Margaret Law Arup What is a Fire Engineer Margaret Law MBE, 1990

2\ Ove Arup and Total Architecture

all relevant design decisions have been considered together and have been integrated into a whole by a well organised team. The Key Speech Sir Ove Arup, 1970

3\ So what is Total Fire Engineering that we in Arup have been talking about?

Total Fire Engineering Prepare Use Fire Safety Solution Design Construct Specify

Total Fire Engineering - Definition all relevant fire design, construction and operation decisions have been considered together and have been integrated into a whole by a well organised team. Simplicity, quality, rigor, knowledge, site implementation and COMPETENCE

3\ Achieving change through Total Fire Engineering Image Sky Believe in Better Building Arup

Goals beyond life safety Goal Social People Life safety Social Quality of Asset Quality of Operation Protection of Asset Quality of space Functionality of space Continuity of asset Protection of Operation Continuity of function

Goals beyond life safety Goal Social Economic People Life safety Quality of Asset Quality of space Cost and value of asset Economic Quality of Operation Functionality of space Operational costs Environmental Protection of Asset Continuity of asset Property Protection Protection of Operation Continuity of function Business Continuity Total Cost = Cost of Prevention + Cost of Protection

Goals beyond life safety Goal Social Economic Environmental People Life safety Quality of Asset Quality of space Cost and value of asset Construction impact Environmental Quality of Operation Functionality of space Operational costs Operational impact Protection of Asset Environmental Environmental continuity of asset Property Protection Prevention of fire damage to the environment Protection of Operation Continuity of function Business Continuity Total Cost = Cost of Prevention + Cost of Protection + Cost of Occurrence

Leeds Arena partial roof protection to improve the structural robustness of the arena & change of facade to omit combustible materials and reduce the overall risk

\ Implementing Total Fire Engineering Brief & Framework 1. Stakeholder Engagement 2. Performance Goals 3. Design Constraints Design 1. Trial Solution 2. Design Review 3. Solution Testing / Assessment Execution 1. Specification 2. Construction 3. Commissioning 4. Handover

Image Herzog & de Meuron and Hayes Davidson Total Fire Engineering = Good design, specification, construction & handover

A great example of Total Fire Engineering The Shard enabling signature architecture from conception through to operations Arup involved from developing the concept, design, construction and handover of the building A perfect example of a building that cannot comply with the code but one where competency in construction and handover was critical to deliver the concept of Total Fire Engineering

Competency in Design & Specification Evolution of Facades Significant changes in the facade design driven by thermal performance, improved solar control and visual appearance Key issue with facades is Material specification. Competence required in understanding what the code is trying to achieve. Number of legal cases arising where this lack of understanding, interpretation and application is being directly challenged.

Competency in Design & Specification Evolution of Facades Evidence is needed for performance of the material in it s end use. This evidence needs to be reviewed and accepted by those competent to do so. Responsibility and liability needs to be understood and communicated

Evolution of Facades Competency in Design & Specification Competency in understanding standardised tests on façade materials (especially combustible insulation) Competency reviewing test certification and product specification Competency in detailing façade interfaces Who in the design team is competent enough in this domain? Fire engineering needs to expand significantly within the domain of designing, specifying of facades.

Construction fire batt / barrier examples Competency in construction

\ Timber Image. Metropol Parasol Arup

Why timber? Image Jeff Martin Image Sky Believe in Better Building Arup Huge push for Timber: Sustainability, Aesthetics, demand for pre-fabrication Sustainability Aesthetics + Innovation Technology & Prefabrication Image l-dsk.ru Key Issues requiring thought and understanding Amount of exposed timber fundamentally changes effective fuel load within buildings Increasing reliance on structural timber forms for preventing fire spread and structural integrity

Image. Scottish Parliamentary Corporate Body Changes in fire behaviour Test evidence indicates charring rate increases with increased fire severity Image. Metropol Parasol Arup Image cecobois.com Impact on fire fighting - even if the fire has burnt out, timber construction smouldering fires can transition back to a flashover fire event. Delamination of engineered timber during fires

\ Timber do we REALLY know? Image. Metropol Parasol Arup

Closing remarks

We should; Design knowingly Be competent in: Design, Specification, Construction and Handover Understand codes and standards Sell on value not cost Lead the construction industry Shoulder appropriate responsibility Be proud Grow

Simplicity Difference Innovation

Thank you for listening