HI Industrial Utility Heater HI Soleus Air International

Similar documents
Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

20 High Velocity Fan with 135 Tilt Head

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

16 Stand Fan with Remote Control Model No: FS3-40R-30

WA A Aqua Sub Bottom-load Water Cooler

42 in. Oscillating Tower Fan w/ Remote Control

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

BASEBOARD MICATHERMIC HEATER

42 Oscillating Tower Fan with Remote Control. OWNER S MANUAL Model # FC1-42R-03

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

18 INCHES, OSCILLATING STAND FAN

PERSONAL SIZE FIREPLACE

TABLETOP PTC TOWER HEATER

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

GL-DEH Series Portable Dehumidifier Operating Instructions

FLCH4R Garage and Utility Electric Heater

INSTRUCTION MANUAL Heavy Electric Utility Heater Model HA24-50E HA24-75E

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

User s Manual & Operating Instructions

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

INFRARED ZONE HEATING SYSTEM

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Electrical Fireplace Stove with Heater

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

Operating Instructions

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Electric Space Heater

CLASSIC PLUS INFRARED ZONE HEATER

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

5) Do not start or stop the unit by inserting or pulling out the power plug.

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

IMPORTANT SAFETY INFORMATION:

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

AH1-CC-01 HEPA Air Purifier Operating Instructions

INFRARED ZONE HEATING SYSTEM

IMPORTANT SAFETY INFORMATION

ELECTRIC STOVE HEATER Models: FS2213B

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP404R-Q

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater


36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

GEN32 SuperBuddy Heater

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

36 WALL MOUNTED FIREPLACE

Electric Garage Heater

Manual for Ceiling Patio Heater

ELECTRIC FIREPLACE OWNER S MANUAL

Portable Dehumidifier

INFRARED QUARTZ HEATER

Portable Dehumidifier with Internal Pump

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

CABINET INFRARED HEATER

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

INFRARED QUARTZ HEATER

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Hardwired Electric Garage Heater

Hardwired Electric Garage Heater

Electric Fireplace Insert with Heater

Model: M630-44FDC CAUTION:

INFRARED ZONE HEATING SYSTEM

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

NO VENTING REQUIRED 120V AC;

ELECTRIC FLAT PANEL FIREPLACE HEATER

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

Wall Mount Electric Fireplace

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

ELECTRIC FIREPLACE INSTRUCTION MANUAL. Item No: 050-HA Model No. FP405R-QA

MODEL: DFH-IQH-62-01, DFH-IQH-62-02, DFH-IQH-62-03, DFH-IQH-62-04, DFH-IQH-62-05,DFH-IQH-06

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

PORTABLE DEHUMIDIFIER

MODELS HS 1300-WS HS-1500-CR HS-1300-TR

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

IMPORTANT INSTRUCTIONS READ & SAVE

BLT-999W-2 Item # 60757

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Transcription:

HI1-50-03 Industrial Utility Heater HI1-50-03 2010 Soleus Air International

Thank you for choosing a Soleus Air Utility Heater. This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new heater. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below: Store Name: Location: Date Purchased: Serial Number (located on back of unit): IMPORTANT INSTRUCTIONS When using this electric unit, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read ALL instructions before using this unit. 2. CAUTION: Risk of Electric Shock. DO NOT open or try to repair the heater yourself. 3. This heater may get hot when in use. To avoid burns, DO NOT let bare skin touch hot surfaces. If provided, use handles when moving this heater. 4. Keep combustible materials, such as furniture, pillows, bedding, paper, clothes, and curtains at least 3 ft from the front of the heater and keep them away from the sides, top, and rear. DO NOT place towels or other objects on the heater. 5. Extreme caution is necessary when any heater is used by or near children or the disabled, or when the heater is left operating and unattended. 6. DO NOT operate any heater with a damaged cord or after the heater malfunctions, has been dropped or damaged in any manner. Return heater to authorized service facility for examination, electrical or mechanical adjustment, or repair. 7. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. NEVER locate heater where it may fall into a bathtub or other water container. To protect against electrical hazards, DO NOT immerse in water or other liquids. 8. DO NOT touch the control panel or plug with a wet hand. 9. DO NOT run cord under carpeting. DO NOT cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over. 10. DO NOT insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater. 11. To prevent a possible fire, DO NOT block the air intakes or exhaust in any manner. DO NOT use 2

on soft surfaces, like a bed, where openings may become blocked. 12. A heater has hot and arcing or sparking parts inside. DO NOT use in areas where gasoline, paint, explosive and/or flammable liquids are used or stored. Keep unit away from heated surfaces and open flames. 13. Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire. 14. To disconnect heater, turn controls to OFF, then remove plug from outlet. Pull firmly on the plug, DO NOT unplug by pulling on the cord. 15. Always unplug the unit before moving or cleaning, or whenever the heater is not in use. 16. Use only for intended use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by unauthorized dealers may cause hazards. 17. WARNING: To reduce the risk of fire or electric shock, DO NOT use this unit with any solid-state speed control device. 18. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. Qualified personnel should perform all servicing only. 19. Connect to properly grounded outlets only. 20. SAVE THESE INSTRUCTIONS. 3

SAFETY INFORMATION 1. Use Copper wire only rated at least 60 C (140 F) 2. For supply connections use No.10 AWG or larger wires suitable for at least 60 C (140 F) 3. Heater air flow must be directed parallel to, or away from, adjacent walls. 4. Observe wall, floor, and ceiling clearance requirements on DIAGRAM 1 on Page 5 of this manual. 5. Do not install closer than 1 5/8 (41.27mm) from the ceiling, 6 feet (2.4 meters) from the floor, or 13 (330mm) from a wall 6. All wiring must comform to national and local electrical codes in the United States and the heater must be grounded as a precaution against possible electrical shock. Heater circuit must be protected with proper fuses. 7. Install only in an area where the proper power-supply connections are available. 8. The mounting structure and the anchoring hardware must be capable of easily and reliably supporting the weight of the heater and the mounting bracket (if used). 9. All electrical power must be disconnected and the main service box must be locked before installing, inspection, cleaning, or servicing the heater to prevent the chance of electrical shock. 10. This heater is not suitable for use in hazardous locations as definied by the National Fire Protection Association (NFPA) in the United States. This heater has hot and arcing (sparking) parts inside. Do not use in ares where gasoline, paint, or flammable liquids are used or stored. 11. This heater is not suitable for use in corrosive atmospheres such as marine, greenhouses, or chemical storage areas. 12. Do not install less than 6 feet (2.4 meters) from of the floor. Improper installation or failure to follow the instructions outlined in this product manual can result in electrical shock. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER-SERVICEABLE PARTS INSIDE 4

HEATER LOCATION AND INSTALLATION Install the heater out of traffic areas maintaining the required clearances below. The direction of air flow shold not be restricted by anything and the air flow should not blow directly at exposed walls. When more than one heater is used in an area, the heaters should be arranged so that the air discharge of each heater supports the air flow of the other heater(s) to provide optimal circulation of warm air DIAGRAM 1 15.7 MINIMUM DISTANCE TO WALL 13 11.29 5 1/2 14.37 MOUNTING LOCATION 24 MINIMUM DISTANCE FROM DISCHARGE TO ANY OBJECT Note: Min. clearance to ceiling when not using mounting brackets is 1 5/8 MINIMUM DISTANCE TO FLOOR 6 ft. MAXIMUM MOUNTING HEIGHT FOR: Vertical air delivery unit = 11 ft. Horizontal air delivery unit = 8 ft. FRONT VIEW SIDE VIEW 5

SPECIFICATIONS Voltage Rating / Amps Power Consumption 208/240 V / 21 Amps / Single Phase 5000 Watts Heating BTU s 17,100 Fan CFM Unit Size Unit Weight 270 CFM 15.7 in. (W) x 11.29 in. (D) x 14.37 in. (H) 27.00 lbs. 6

LOCATION AND INSTALLATION (CONT.) MOUNTING THE BRACKET 1. Locate a stud in the ceiling joist. 2. Remove the mounting bracket from the heating unit be loosening the bracket screws with a wrench and slipping the handle off over the screw heads. 3. Place a washer on the screws before inserting through the holes in the mounting bracket and screw them securely into the ceiling joist. NOTE: If you want the heater to swivel side to side, add a washer to both sides of the bracket. A longer lag bolt may be required to properly secure the unit. 4. Tighten the screw enough to securely hold the heater with the airflow pointed in the proper direction. SINGLE SCREW MOUNTING DOUBLE SCREW MOUNTING HANGING THE HEATER 1. Lift the heater up and into the mounting bracket. 2. Align the bracket screws with the keyhole slots in the mounting brackets 3. If the heater is to be tilted, it must be positioned in the keyhole slots. 4. Tighten the bracket screws with a wrench so the unit is securely suspended at the desired horizontal or vertical level. 7

LOCATION AND INSTALLATION (CONT.) CONNECTING THE POWER 1. Turn off the power at the main service 2. Remove the screw from the back of the unit to connect the power to the heater. 3. Attach the cable connectors to the unit and slide the 10 gauge wire through the cable connector. NOTE: For certain applications, conduit may be required. Check your local electrical codes. If you run the wiring in conduit and wish to be able to rotate the heater, be sure to purchase enough flexible conduit to allow the heater to be rotated. 4. Connect the wire to the power terminal block located in the base of the heater. 5. Turn on the power at the main service. OPERATION NOTE: The first time you operate this heater, it may emit a slight odor and some smoke. This is due to the residual cleaning agents used to clean the element during manufacturing. This is normal operation and will cease after the heater has been used for a few minutes. 8

OPERATION (CONT.) ADJUSTING THE AIR FLOW DIRECTION 1. Rotating the unit - if the unit has been installed with a single lag bolt, simply rotate the entire unit as needed to adjust the direction of the air flow. 2. Tilting the unit - Loosen the bracket screws, tilt the heater to the desired position, and re-tighten the bracket screws. NOTE: To tilt the heater it must be mounted in bottom keyhole slots of mounting brackets to maintain adequate clearance and prevent possible overheating. 3. Adjust the louvers to the desired position. NOTE: The louvers are designed so they cannot be completely closed. Do not attempt to close the louvers completely as this may damage the unit.. To prevent possible electric shock, disconnect the power to the heater at the main service box before attempting to adjust the heat output of the unit. 9

OPERATION (CONT.) WIRING DIAGRAM 1. It is recommended that #10 AWG wire be used in all installations for possible future reconnection at a higher wattage (Refer to the National Electric Code (NEC) for maximum run length to minimize voltage drop to 3% max. Circuit runs exceed 100 ft. may require larger conductor size). 2. Wires should be routed through the indicated element jumper wire eliminating the use of a wire tie. 10

MAINTENANCE To prevent possible electric shock, disconnect the power to the heater at the main service box before attempting inspect or clean the unit. Use care to prevent damage to the internal components of the heater when cleaning the heating element. Make sure all connections remain tight and all wiring is routed away from the element fins when reassembling the unit. Allowing wiring to touch the element fins could result in a fire hazard. CLEANING THE FAN AND MOTOR Remove the protective grille from the rear of the heater. This provides access to the fan and motor. Wipe off the fan and motor with a soft cloth or brush. The fan motor does not require lubrication. Replace the protective grille when finished. 11

WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Heater to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of charge within a reasonable time after the unit is returned during the warranty period. As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a copy of the original purchase invoice. THIS WARRANTY DOES NOT COVER: Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in material or workmanship. Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the instructions. This includes dents, accidental or otherwise, to the base and head of the unit. Damage to the finish of the case, or other appearance parts caused by wear. Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc. Freight and Insurance cost for the warranty service. ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC. DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT. This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, salvaged, or refurbished products. As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For Technical Support or Warranty Service Please Call (888) 876-5387 Or Write To: Soleus International Inc. 20035 E. Walnut Dr. N. City of Industry, CA 91789 USA www.soleusair.com 12