HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Similar documents
OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Owner s Manual PRINTED IN CANADA 05/2009

Q&A 2016 Practical Guide

OWNER S Manual PRINTED IN CANADA 10/2009

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

CONTENTS. Installation Guide. VT7200 Series

POOL & SPA HEAT PUMP OWNER S MANUAL

Quick Start Guide. For product manuals and further installation / operation procedures visit

DIGITAL METERS Large Display Temperature Meters Instruction Manual

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

I/O ZONE 560/583 AND OPERATION MANUAL

VH7200 Humidistat Series For Humidification & Dehumidification Control For Commercial HVAC Applications (Issue Date January 22, R7)

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

BasicTroubleshooting Information and Guidelines

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

ELECTRONIC COMMUNICATING THERMOSTAT

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

PARAGON Commercial Refrigeration Controls

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Emerson Blue Easy Set 1H/1C

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

INSTALLER S & OWNER S MANUAL

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

Mark 25 Ultrapure Water Conductivity Analyzer

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

INSTALLER S & OWNER S MANUAL

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Smart Temp. Model

CONTROL PANEL INSTRUCTIONS RSQ-4

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

T600MEP-2 Programmable Economizer Thermostat

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Table of Contents SECTION PAGE

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

TEC210x-2 Series Networked Thermostats

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

PCR-300 PCR-300 RC. Installation and Operating Instructions

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Installation Instructions

REACH-IN SAFETEMP (-AAC)

SC Installation, Operation & Application Guide

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

DT968C C.T. BATH CONTROLLER

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Hoshizaki America, Inc.

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Thermo 230 / 231 / 300 / 301 / Troubleshooting

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

50A Integrated Furnace Control

SC Installation, Operation & Application Guide

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

JDDT1 - Single Stage Digital Thermostat

MODEL B2 INSTALLATION MANUAL

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Operator: Save these instructions for future use!

TEC2100 Series Networked Thermostats

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

BGH Series Hot Surface Ignition Control

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

NO. F ISSUED: JUN. 18, 2008 REVISED: JUN. 17, 2011 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-100A KM-125A MODEL SERVICE MANUAL

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

Operator: Save these instructions for future use!

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

RSMSD Technical Guide

SC Installation, Operation & Application Guide

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Hoshizaki America, Inc.

Condensing Unit Installation and Operating Instructions

WARNING Important Safety Information

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Operator: Save these instructions for future use!

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

Transcription:

HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring 6. Instrument Identification 7. Operation 8. Service and Calibration 9. Troubleshooting 10. Defrost Cycle Sequence 11. Temperature Sensor Chart 12. Advanced Applications 1 M:\1_BINDER\08_HP7XX\09_HP727S\HP727S-S_03.doc 4/6/04

1. GENERAL DESCRIPTION The HP727SS is a powerful microcomputer control designed for use in an outdoor swimming pool heatpump. The control features 3 digit temperature display and 3 push button keys. All adjustments are performed by simple key operations. The HP727S controls the main compressor contactor, the evaporator fan, and the water circulating pump. The HP727S monitors both evaporator and water temperature using precise thermistor sensors for superior control. The control features full diagnostics messages, simplifying both installation and service. The HP727S is an excellent alternative to electromechanical controls offering improved water temperature control accuracy, accurate defrost control, anti-short cycle timer, and solid-state reliability all in a single package. All calibration and user parameters are stored in an EEPROM memory. There are no trimmer potentiometer adjustments. All adjustments including sensor calibrations are done through the front panel. The HP727S features full self-test diagnostic capability and sensor re-calibration if needed. The HP727S offers maximum corrosion and vibration protection. All printed circuit board interconnections are soldered. The main PCB is dipped in silicone. This assures maximum board protection even underneath the PCB components, against humidity, air pollutants, chlorine vapors and vibrations. 2. VICONICS HP727S SWIMMING POOL HEATPUMP CONTROL SPECIFICATIONS OPERATING CONDITIONS: Rated Operating Conditions: Storage: 33 F to 120 F; R.H. 0% to 100 %, Non-Condensing - 40 F to 120 F; R.H. 0% to 100 %, Non-Condensing PERFORMANCE: Accuracy: ± 1.8 F Repeatability: ± 0.2 F Resolution: ± 1 digit INPUTS: Swimming Pool Water Return Temperature Thermistor Sensor ( 0 F To 120 F ) Evaporator Defrost Temperature Thermistor Sensor ( 0 F To 120 F ) Contact From Remote High Pressure Switch Dry Contact Input Contact From Remote Low Pressure Switch Dry Contact Input Contact From Main Flow Switch Dry Contact Input Contact From Remote Spa Select Flow Switch Dry Contact Input OUTPUTS: Compressor Relay Output:: Fan Relay Output: Circulating Pump Relay Output: 1A @ 24 Vac 4A @ 240 Vac 1A @ 24 Vac GENERAL: Complete Diagnostic Error Messages Display: 3 Digits Display 0.56" High LED Status Indicators: Pool mode LED, Spa mode LED and Heat on LED Power supply : 0 / 12 / 24 Vac center tap transformer ±10% 50\60 Hz - 5 VA required on 12 Vac for controller only - 100 VA maximum for 24 Vac power connection Dimensions: approx. 5.5" x 6.0" Weight: 700 gm (1.51 lb.) Protection Against Humidity: Unit dipped with silicone based conformal coating Connectors: 1/4" fast-on connectors; screw terminals for field connections ccsaus file # LR92123 2

Important note: Heatpump unit should not be operated when outdoor air temperature is near or under freezing point; or as specified by manufacturer of heatpump. 3

3. INSTALLATION INSTRUCTIONS UNPACKING Examine the package on reception for any signs of external damage it may have received during transit. If damage is found, notify the carrier immediately. Notify manufacturer or their agent immediately of any deficiencies. INSTALLATION: Take care in handling the Printed Circuit Board ( PCB ) so as not to damage or scratch the silicone conformal coating. Damage to this coating will affect the resistance to moisture and humidity. Install the board to the front panel using # 6-32 screws. Push ( or remove ) the fast-on connectors at a right angle to prevent bending the board connectors. Align and install the lexan cover membrane to the metal door. 4. ELECTRICAL WIRING CAUTION: NO HIGH VOLTAGES ARE PRESENT ON THE TERMINALS OF THIS INSTRUMENT ( EXCEPT AT THE FAN RELAYS TERMINATIONS ) PLEASE READ ALL THE INSTRUCTIONS IN THIS MANUAL CAREFULLY, AND HAVE THE WIRING DONE BY A SKILLED PROFESSIONAL. THE INSTRUMENT HAS UNDERGONE RIGOROUS TESTS AND VERIFICATIONS PRIOR TO SHIPMENT TO ENSURE PROPER AND RELIABLE OPERATION IN THE FIELD. IT IS THE RESPONSIBILITY OF THE USER OR ELECTRICAL PANEL DESIGNER TO INCORPORATE SAFETY FEATURES ( SUCH AS OVER / UNDER TEMPERATURE CUTOUT DEVICES ) TO PROTECT THE ENTIRE SYSTEM FROM GENERAL FAILURES. All wiring must conform with local or national electrical code regulations. See fig. 2 for electrical wiring diagram Some wiring to the board is done using 1/4" fast-on connectors. The instrument should be wired before applying power! Power supply : 0 / 12 / 24 Vac center tap transformer ±10% 50\60 Hz - 5 VA required on 12 Vac for controller only - 100 VA maximum for 24 Vac power connection The instrument front panel needs to be splash proof, and protected against the elements. The HP727S electronic controller should be mounted inside the control panel is NOT waterproof. The electrical panel must therefore be properly protected against rain, dust and excessive water vapor condensation. 4

5. INSTRUMENT WIRING DIAGRAM Wiring Diagram Brown Black & White CAP Red FAN F C Herm. HP727-S Control Board RLY1 Yellow Yellow C S R COMPRESSOR 24 Vac compressor contactor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 White Brown Water sensor Remote switch Pool (opened) Spa (closed) Defrost sensor High pressure switch Closed = OK Opened = high pressure Low pressure switch Closed = OK Opened = low pressure Flow switch Closed = flow Opened = no flow Black Black Light Blue Light Blue Purple Purple FILTER PUMP Blue Blue 24 Vac 12 Vac 0 Vac 24 Vac transformer 24 Vac filter pump contactor L1 Black Orange (240 Vac) or Red (208 Vac) L2 or Neutral Ground L1 L2 208 / 240 Vac 50 / 60 Hz Wiring727.dsf 5

6. INSTRUMENT IDENTIFICATION Pool LED Heat on LED Spa LED Increase key Decrease key DESCRIPTION OF FRONT PANEL: Service / Select key POOL LED: Indicates that the Pool setpoint is selected. SPA LED: Indicates that the Spa setpoint is selected. HEAT ON LED: Indicates that the pool heater ( heatpump compressor ) is on, heating the water. DIGITAL DISPLAY: Normally displays the actual water temperature. In set mode displays other parameters. SERVICE / SELECT KEY: Used to enter the service mode or select between Pool and Spa temperature setpoint. INCREASE KEY : Increases the selected parameter value. DECREASE KEY : Decreases the selected parameter value. NOTE: The display may be changed in steps by pushing the or keys repetitively, or automatically by holding down the same key longer. 6

7. OPERATION: WHEN POWER IS FIRST APPLIED TO A FACTORY UNIT: The display will show [888] and the 3 status LED s will come on for 4 seconds and then go off for 1 second. The pump will go on and then the actual water temperature will be displayed. Factory settings of main parameters: Pool setpoint: OFF Spa setpoint: OFF Filtration time FIL: 8 hours per day The actual temperature displayed is held in memory and displayed for 5 minutes until the water temperature sensor has sampled circulating water. After that delay of 5 minutes, the displayed temperature is automatically updated and displayed. CONFIGURING THE UNIT J1 JUMPER The unit can control 2 different setpoints: The pool temperature and the Spa temperature. 2 methods can be used to switch the unit between ( Pool setpoint Mode ) or ( Spa setpoint Mode ). How to activate either ( Pool setpoint Mode ) or ( Spa setpoint Mode ) J1 jumper not cut Using the select key will active either mode manually ( press the or to switch between ( P_S ) J1 jumper cut A remote Spa flow switch connected on CN19 will activate ( Spa setpoint Mode ) ** ** Notes: In this mode using the select key will authorize changing the Pool or Spa setpoint, but the actual mode is determined by the Spa flow switch connected on CN19. The Pool LED or Spa LED on the display will confirm which mode is active. ADJUSTING POOL & SPA SETPOINTS: Setpoint ranges: Controller configured in F Controller configured in C Pool setpoint: OFF 61 F to 95 F OFF 16 C to 35 C Spa setpoint: OFF 61 F to 104 F OFF 16 C to 40 C The control is shipped with setpoints at OFF in Pool and Spa mode. The heatpump is automatically switched OFF if a setpoint below 61 F is selected. In the off mode the control will display the water temperature. Use the select and arrow key to enter Pool or Spa mode. Use the arrow to increase the setpoint above 61 F on the selected mode. The pool heater ( heatpump compressor ) is automatically authorized to operate if a setpoint above 61 F is selected. Adjust the setpoints to required value. TURNING THE POOL HEATER ON ( HEATPUMP COMPRESSOR ): When there is a demand for heat. In Pool mode: If the actual water temperature is lower than the desired Pool setpoint temperature. In Spa mode: If the Spa mode is manually selected ( J1 in place ) Or if the Spa flow switch is energized ( J1 cut ) And if the actual water temperature is lower than the desired Spa setpoint temperature. When heatpump is energized: The Heat On LED is energized. The compressor will come on. The fan will come on as dictated by coil temperature. Heat will stay on until setpoint is satisfied. 7

Note that each time the compressor turns off there will be a 3 minute anti-cycling delay before it can be turned on again. 8

ADJUSTMENT OF MINIMUM FILTRATION TIME The HP727S features an adjustable minimum filtration period. Parameter FIL. A daily 24 hours cycle is divided 6 daily periods of 4 hours ( 240 minutes ). The adjusted parameter value represent the minimum total daily hours that filtration is required. FIL parameter adjustments: OFF 2 hours to 23 hours ON Pump is always OFF Pump will work 2 to 23 hours daily Pump is always ON In OFF mode the circulating pump needs to be always on, or energized by an external timer clock. In ON mode, the circulating pump is always on. The selected minimum filtration time is divided equally into the 6 daily periods. Ex.: Selected 4 hours 6 periods = 40 minutes per period. So the circulating pump will work 40 minutes for each period of 4 hours. The minimum selectable filtration time is 2 hours ( 6 periods of 20 minutes each ) When the circulating pump is energized, if there is a heating demand during a filtration period: The circulating pump will stay on until the heating demand is satisfied. During that period the minimum filtration time counter is still active and counting. If the daily minimum filtration time is obtained and the heat demand is not satisfied, the circulating pump will stay on until the heating demand is satisfied. If the daily minimum filtration time is obtained and the heat is satisfied, there is still a 15 minutes circulating pump time per period ( every 4 hours ). This is done to sample the pool water temperature is case the water needs to be heated. ( not valid if FIL parameter = OFF ) Whenever the FIL parameter is changed, the daily counter will reset. BACKWASH OPERATIONS: For backwash operation do the following: 1. Cut out power to the pump ( with line voltage switch or ( FIL = off, POL = off and SPA = off )). 2. Prepare system for backwash and energize the pump ( with line voltage switch or ( FIL = on )). 3. The circulating pump will go ON and the controller will not check for 5 minutes if water flow is present at pool flow switch. 4. You will have 5 minutes of uninterrupted water flow to do the backwash. 5. To stop the circulating pump use ( the line voltage switch or ( FIL = off )). Normally, when the circulating pump is requested to operate, and there is no water flow detected at the flow switch, the pump will automatically cut off. This procedure will give a 5 minutes period of uninterrupted water flow, before the circulating pump cuts off. TO CHANGE THE DISPLAY BETWEEN F OR C: Factory default is F Touch and hold down the set key until the message POL appears Touch the [Service / Select ] key until the message F_C appear. Touch the arrow key to select F or touch the arrow key to select C EEPROM RECOVERY: If a flashing PLE or CSE error message appears, hold down the Service / Select key until the error message disappears ( approx. 4 seconds ). The control will be re-initiated to factory default. Re-enter the Pool / Spa setpoints and minimum filtration time parameter. HEATPUMP DEFROST OPERATION: During the defrost cycle of the evaporator coil, the display will show FS to indicates that the unit is defrosting. During this time the fan is on and the compressor is inactive. See section 10. for defrost sequence. 9

8. SERVICE AND CALIBRATION: CALIBRATION AND RECONFIGURATION SHOULD BE DONE WITH CAUTION BY QUALIFIED PERSONNEL ONLY. To enter the service mode, press down the Service key, for 8 seconds, until the display show the message Loc. You have 12 seconds from the time the last key was touched to make an adjustment. 12 seconds after the last key was depressed, any modified value will be stored into EEPROM memory. After that, the unit will return to normal operation mode. Adjustable parameters: Loc Lock code Adjustable from 00 to 99 ( 00 is no lock mode at all ) Factory default value is 50 del Compressor anti-cycle delay by-pass Parameter value is at 0. Adjust value to 1 and wait until control goes back in normal operation mode. 3 minutes anti-cycling delay is by-passed for 1 cycle only. tsc Water temperature calibration ( Shows the actual water temperature ) Adjustment is ± 5 F ( ± 3 C ) dsc Evaporator defrost temperature calibration. ( Shows the actual evaporator temperature ) ( Viewable in calibration mode only ) Adjustment is ± 5 F ( ± 3 C ) db1 Pool / Spa setpoint hysterisys 0.2 F to 2.0 F ( 0.1 C to 1.1 C ) Factory adjustment is 0.8 F Pressing the Service / Select key repetitively will scroll down all parameters. Go to the desired parameter. The display will show the parameter name. Use the or arrow once to display the actual value of the selected parameter. Use the or arrow to adjust the parameter to the selected value The display may be changed in steps by pushing the arrows briefly, or faster by holding down the desired arrow key. NOTE: Any modified parameter value will be stored 12 seconds after the last arrow key was touched The new value will be stored into EEPROM memory and the unit will return to normal operation mode. Important notes: Any time a new parameter value is stored, the display will blank out momentarily Any modified parameter should be stored in writing on the instrument label inside the heatpump unit. LOCK CODE ( Loc ): The lock code provides security against unauthorized tampering of parameter values. If the lock feature is enabled Pressing the [Service / Select ] key for 8 seconds, will make the "Loc" message appear on the display. Enter the Loc code value using the arrows. If an incorrect code is entered, the unit will exit the service mode, and the entire process will have to be repeated. Once the proper lock code is entered, the lock value can be modified the second time the Loc parameter appears while scrolling down the parameters. If the Loc code is forgotten, proceed with the following procedures: - Remove the power from the instrument. - Press and hold the [Service / Select ] key while powering-up the instrument. - The message del will appear. - The lock function is temporarily disabled. - Step to Loc parameter, as re-enter a new value as described in the above procedure. 10

9. TROUBLE SHOOTING: The instrument is capable of detecting a number of malfunctions, which may occur operating conditions. When a malfunction occurs: 1) The heatpump fan and compressor are turned off. 2) The display flashes an error code for 5 seconds. 3) The instrument goes into power-up and restart sequences. If the malfunction persists this process is repeated. Error codes: dpo Evaporator temperature sensor connection Check for cut or loose sensor wiring or defective evaporator sensor. opened PO Water temperature sensor connection opened Check for cut or loose sensor wiring or defective water sensor. dpc Evaporator temperature sensor connection Check for a short in sensor wiring or defective evaporator sensor. shorted Pc Water temperature sensor connection Check for a short in sensor wiring or defective water sensor. shorted LP Low pressure Check for refrigerant leaks or defective low pressure switch or wiring. HP High pressure Check for evaporator fan operation or defective high pressure switch or wiring. FLo No water flow at main flow switch Circulation pump is off, filter is clogged or on backwash. Defective flow switch or wiring. FS Evaporator frosted Heatpump in defrost cycle mode. PLE EEPROM memory data loss If the PLE or CSE error message appears, hold down the Service / CSE EEPROM memory data loss Select key until the error message disappears ( approx. 4 seconds ). The control will be re-initiated to factory default. Re-enter the Pool / Spa setpoints and minimum filtration time parameter. SPi Defective controller Remove power and re-start. If error is still present, replace the unit. Error management: 1. An LP error code will stop the circulating pump, other errors will not stop the pump. 2. Error codes will not prevent access to user and service mode. HP error code: When HP error code becomes active, the compressor and the fan will stop. After 3 consecutive HP detection within an hour, the lockout mode for HP3 will be activated. To get out of the HP3 lockout mode, a button must be depressed. The unit may re-enter HP3 lockout mode if again there are 3 consecutive HP detection s within an hour. LP error code: When LP error code becomes active, the compressor and the fan will stop. After 3 consecutive LP detection within an hour, the lockout mode for LP3 will be activated. To get out of the LP3 lockout mode, a button must be depressed. The unit may re-enter LP3 lockout mode if again there are 3 consecutive LP detection s within an hour. FLo error code: If parameter FIL = off, the Flo error message will be displayed whenever the flow switch does not register any water flow. If parameter FIL = on, the Flo error message will be displayed whenever the flow switch does not register any water flow. If parameter FIL is selected between 2 to 23 hours of operation daily: If the main flow switch detects no water flow when the circulating pump is requested to operate: Pump will stop after a 5 minutes on delay and display the FLo error code. After a 5 minutes off delay, the system will attempt to restart the circulating pump. After 3 consecutive retry, if the pump still does not start the circulating pump lockout mode will be activated ( FL3 error code). 11

To get out of the pump lockout mode ( FL3 error code), a button must be depressed. The unit may re-enter FL3 lockout mode if again there are 3 consecutive FLo error detection s within an hour. 12

10. DEFROST CYCLE SEQUENCE: The HP727S has an evaporator temperature sensor to control the defrost cycle when the compressor operates. Whenever the compressor starts, the evaporator fan starts also. The fan and the defrost cycle are controlled as follow. Fan operation Defrost cycle operation Compressor OFF Fan always on during defrost cycle Fan on Compressor still ON 60 F 52 F 44 F 42 F 24 F Evaporator temperature 13

11. TEMPERATURE SENSORS RESISTANCE & VOLTAGE CHART: Temperature F Temperature C Sensor Resistance Sensor Voltage Drop 180.0 F 82.2 C 0.549 Kohm 0.523 Vdc 175.0 F 79.4 C 0.601 Kohm 0.567 Vdc 170.0 F 76.7 C 0.659 Kohm 0.614 Vdc 165.0 F 73.9 C 0.722 Kohm 0.666 Vdc 160.0 F 71.1 C 0.793 Kohm 0.722 Vdc 155.0 F 68.3 C 0.872 Kohm 0.783 Vdc 150.0 F 65.6 C 0.961 Kohm 0.849 Vdc 145.0 F 62.8 C 1.060 Kohm 0.920 Vdc 140.0 F 60.0 C 1.170 Kohm 0.997 Vdc 135.0 F 57.2 C 1.294 Kohm 1.080 Vdc 130.0 F 54.4 C 1.434 Kohm 1.169 Vdc 125.0 F 51.7 C 1.591 Kohm 1.265 Vdc 120.0 F 48.9 C 1.768 Kohm 1.367 Vdc 115.0 F 46.1 C 1.968 Kohm 1.476 Vdc 110.0 F 43.3 C 2.194 Kohm 1.591 Vdc 105.0 F 40.6 C 2.451 Kohm 1.714 Vdc 100.0 F 37.8 C 2.741 Kohm 1.842 Vdc 95.0 F 35.0 C 3.072 Kohm 1.976 Vdc 90.0 F 32.2 C 3.448 Kohm 2.116 Vdc 85.0 F 29.4 C 3.879 Kohm 2.261 Vdc 80.0 F 26.7 C 4.370 Kohm 2.409 Vdc 75.0 F 23.9 C 4.935 Kohm 2.561 Vdc 70.0 F 21.1 C 5.583 Kohm 2.715 Vdc 65.0 F 18.3 C 6.328 Kohm 2.869 Vdc 60.0 F 15.6 C 7.187 Kohm 3.023 Vdc 55.0 F 12.8 C 8.180 Kohm 3.175 Vdc 50.0 F 10.0 C 9.334 Kohm 3.325 Vdc 45.0 F 7.2 C 10.671 Kohm 3.471 Vdc 40.0 F 4.4 C 12.230 Kohm 3.612 Vdc 35.0 F 1.7 C 14.044 Kohm 3.746 Vdc 30.0 F -1.1 C 16.167 Kohm 3.874 Vdc 25.0 F -3.9 C 18.655 Kohm 3.994 Vdc 20.0 F -6.7 C 21.581 Kohm 4.106 Vdc 15.0 F -9.4 C 25.036 Kohm 4.210 Vdc 10.0 F -12.2 C 29.110 Kohm 4.305 Vdc 5.0 F -15.0 C 33.950 Kohm 4.392 Vdc 0.0 F -17.8 C 39.683 Kohm 4.471 Vdc 14

12. ADVANCED APPLICATIONS: Remote Poll / Spa mode toggle with a remote switch. The unit can control 2 different setpoints: The pool temperature and the Spa temperature. 2 methods can be used to switch the unit between ( Pool setpoint Mode ) or ( Spa setpoint Mode ). How to activate either ( Pool setpoint Mode ) or ( Spa setpoint Mode ) RED J1 jumper not cut Using the select key will active either mode manually ( press the or to switch between ( P_S ) RED J1 jumper cut A remote Spa flow switch connected on CN19 will activate ( Spa setpoint Mode ) ** ** Notes: In this mode using the select key will authorize changing the Pool or Spa setpoint, but the actual mode is determined by the Spa flow switch connected on CN19. The Pool LED or Spa LED on the display will confirm which mode is active. CN19 18 19 Remote switch Pool (opened) Spa (closed) Remote control of heat pump operation with a remote switch. ( On / Off operation ) For operation when the temperature is controlled by an external controller The unit internal temperature control is by-passed to On / OFF operation from a remote switch. - First cut the RED J1 jumper. - Set Pool setpoint to OFF - Set Spa setpoint to its maximum value of 104 F or 40 C A remote switch connected on CN19 will now control the unit in On/Off mode. ** Notes: In this mode, the flow switch, high pressure, low pressure and anti-cycling protections are still performed by the HP727S controller. A maximum temperature of 104 F ( 40 C ) can be attained by the remote controller. CN19 18 19 Remote control switch OFF (opened) Pool setpoint is OFF ON (closed) Spa setpoint is set to maximum 104 F or 40 C 15