Application Note Automated Implementation of U.S. DOE PEM Fuel Cell Durability Protocols using Scribner Fuel Cell Test Systems

Similar documents
Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

LineGuard 2300 Program User Manual (FloBoss 107)

Analog Room Pressure Monitor RPC Series

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

SCAN200E USER S MANUAL

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

CALIDUS tm the Modular micro Gas Chromatograph

Avigilon Control Center 5 System Integration Guide

Monitoring Software for NPBC-V3M-1 User Manual

GPS Evaluation Kit EVA1037/1080

MicroTech Series-200 Flooded Screw Chiller

ComfortSense 7500 Thermostat. User Guide

MODEL 4300-PG CENTRAL ACCESS PANEL FOR EC-GOLD TRANSMITTERS. User Manual

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

Technical specifications of FT-IR Spectrometer

USB DATA LOGGER FOR TEMPERATURE AND RH HM9000

Laptop / PC Programming Manual

Hydrogen Generator Model HPNM 1. Instruction manual. 166 Keystone Drive Montgomeryville, PA Phone: Fax:

Installation, Configuration and User Manual

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

THERMOSYS 4.3. Getting Started Guide

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Operation Manual v Fax: +33 (0) U.K.: +44 (0)

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Wiser Air User Interface Guide. Thermostat

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

Electronic Pellet Burner Controller NPBC-V3-1

JOVY SYSTEMS RE-7500 User Manual Rev Index

OVEN INDUSTRIES, INC.

PowerRouter application guideline

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Warranty Registration

Service Manual for RESmart CPAP V1.0. RESmart TM CPAP System. Service Manual

Multi Boiler Guide. Kit #

SECTION Free/Available Chlorine Analysis System

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Bosch TCU Integration Module Administrator's Guide

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Static Pressure Control

Avigilon Control Center System Integration Guide

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

725B Configuration Software Manual

Thermo Scientific Wellwash User Manual. Rev. 1.0

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

GLD-30 Gas Leak Detector

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Huminator II. Precision Humidity Generator. ww.testo.in

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

Waters 2795 Separations Module

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

FlameGard 5 MSIR HART

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

ComfortSense 7500 Commercial Thermostat. User Guide

DEL MAR SULFURELITE Hydrogen Sulfide Analyzer

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

QIAcube HT Unpacking and Installation Instructions

Smart thermostat with Humidification/De-humidification control

Fratech Multipath-IP

AIR CONDITIONER PERFORMANCE RATING

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

EL-OEM-3 OEM Packaged Voltage Data Logger

CLEANROOM MONITOR CR3A Network - Installation Instructions

MPL3115A2 Sensor Toolbox User s Guide

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

MHC Series Sensors

UNC100 Integra Manual

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

IndigoVision Alarm Panel. User Guide

TABLE OF CONTENTS. Principle of operation of CAFM...1. Installation instructions...2. Main ADC Operating screen...3. Set process temp and Setback...

RNAscope LS 4-plex Fluorescent Assay

Thermo Scientific Wellwash Versa User Manual. Rev. 1.0

EC3-X33 Stand-alone Superheat Controller Technical Data

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

WeatherLink for Alarm Output Addendum

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Refrigerated Incubator Model and Operating Instructions

Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer

Avigilon Control Center System Integration Guide

VX SERIES Wireless Thermostat with Occupancy Sensor

MPT Electric Fire Pump Controller

M2500 Engine Controller Installation Manual

Smoke Layer Height and Heat Flow through a Door

Transcription:

Application Note Automated Implementation of U.S. DOE PEM Fuel Cell Durability Protocols using Scribner Fuel Cell Test Systems Introduction Durability is a key performance property of polymer electrolyte membrane fuel cells (PEMFCs). The U.S. Department of Energy s (DOE) Fuel Cell Technology Office (FCTO) has developed accelerated stress tests (AST) to evaluate the durability of low temperature PEMFCs [1]. Test protocols exist that are intended to evaluate the mechanical and chemical durability of the membrane, the durability of the catalyst support, and the durability of the electrocatalyst, among others. Scribner has developed the hardware, FuelCell software setups and scripts for automated execution of DOE PEMFC Durability Protocols. The protocols are defined in the 2017 FCTO Multi-Year Research, Development, and Demonstration Plan (MYRDDP) 1. Test protocols given in Appendix of the Fuel Cells Section of the MYRDDP include: Electrocatalyst Cycling for Cathode Electrocatalyst Durability Table P.1 Catalyst Support Cycling for Catalyst Support Durability Table P.2 MEA Chemical Stability for Membrane Chemical Durability Table P.3 MEA Mechanical Cycling for Membrane Mechanical Durability Table P.4 Combined Chemical/Mechanical Cycling for MEA Durability Table P.5 Polarization Curve Table P.6 Unmitigated Start-Up / Shutdown Durability Protocol Table P.8 MEA Recovery Protocol Table P.9 This document covers fully- or partially-automated implementation of the fuel cell testing protocols using Scribner s fuel cell test systems and software. Hardware requirements, FuelCell setups and Arbitrary Control files (scripts) are discussed, as are precautions and notes. Required Hardware Requirements (specific hardware requirements depend on the durability protocol to be implemented) 1. 850C/e Fuel Cell Test System with Auto Water Fill 2. Humidifier By-Pass Option is required to implement the Membrane Mechanical Durability Protocol 3. Auto Multi Gas (AMG) Unit Specific gas configuration depends on the protocol to be implemented a. H2 connected to Anode Port A b. Air connected to Cathode Port A, N2 connected to Cathode Port B 4. 885 Fuel Cell Potentiostat for ECSA by CV and H2 Crossover by LSV as well as for Electrocatalyst and Catalyst Support Durability Protocols 1 https://www.energy.gov/sites/prod/files/2017/05/f34/fcto_myrdd_fuel_cells.pdf 1 rev. A, 1/2019

5. Automated Humidifier Drain / Fill (AHDF) Option (factory installation required) for rapid cooling of humidifiers see Note 11 if your system is not equipped with the AHDF Option 6. Temperature Controlled Fan for Cell Cooling for rapid cooling of cell fixture 7. 5 or 25 cm 2 PEMFC fixture with MEA (FuelCell setups are for a 25 cm 2 cell) 8. Automated or manual back pressure unit 9. Pressurized supply of DI water 850R External Interface with at least one MFC (5 SLM Air or N2 recommended) required for implementation of Unmitigated Start-Up / Shutdown Durability Protocol Table P.8 Notes 1. Users of the setups and script files provided by Scribner should fully understand the procedure and verify that their instrument configuration matches that used for the provided setups. o e.g., H2 connected to AMG Anode Port A, Air connected to AMG Cathode Port A, and N2 connected to AMG Cathode Port B o e.g., 25 cm 2 active area o Alternatively, the provided setups can be modified to match the user s instrument configuration 2. The FuelCell software setup files (.fc3) and the Arbitrary Control files (.fcc) should be located in c:\fuelcell\setups. The folder \Setups\ must be created by the user. 3. Select Replace Files or Background Search + Replace File Names to change the placeholder text YYYYMMDD in the file names with a unique identifier, such as the date or sample ID. Refer to the Replace Names feature in the FuelCell software manual. 2 rev. A, 1/2019

4. The default location for data files are is c:\fuelcell\data\. This can be changed by first creating a folder that the data files will be saved to, and the using Replace Files feature to change the path name. 5. The FuelCell software setup files assume a 25 cm 2 cell. If testing a cell of different active area, the anode and cathode flow rates and current values used for the polarization curve (and other current-controlled steps) must be modified. 6. The FuelCell software setup files for the Electrocatalyst and Catalyst Support Durability test protocols assume the 850e unit is equipped with an 850 Auto Multi Gas unit with H2 plumbed (connected) to Anode Port A, Air plumbed to Cathode Port A and N2 connected to Cathode Port B. 7. The FuelCell software setup file for the Membrane Mechanical Durability test protocol assumes the unit is equipped with an 850 Auto Multi Gas Unit with gas plumbed as shown in the table: AMG Port Anode Cathode A H2 Air B N2 N2 C Air Unused 8. The Membrane Mechanical Durability AST is based on cycling between super-saturated and dry gas and therefore requires that the 850e is equipped with the Wet-Dry Humidifier By-Pass Option. 850e units equipped with this option have WD listed under the Options section of the serial plate located on the rear panel of the unit. Contact Scribner for additional information or clarification if you are unsure if your 850e has this option. 9. Under H2 / N2 conditions, the cell voltage is ~ 0.1 V. To avoid a system shut down due to low cell voltage, in the Setup Cell menu, set the Minimum E (V) and Shut Down E (V) values to -1 and -2, respectively. This effectively disables the low voltage alarms. This can also be done with a Change Cell experiment step as part of the experiment list. 10. Older 885 PSTATs that connect to the 850e via the Auxiliary Signals Connector have a maximum data acquisition rate of 0.1 s/point (10 points/s). Current highspeed 885 PSTATs use a USB connection to the host computer and have a maximum data acquisition rate = 0.01 s/point (100 points/s). The data sample rate in the 885 PSTAT Sweep Voltage experiments should be set accordingly. 11. If your test system is not equipped with the Automated Humidifier Drain / Fill (AHDF) Option please refer to Application Note Manual Method for Accelerated Humidifier Cooling. 3 rev. A, 1/2019

12. The FuelCell software setup files for the Electrocatalyst and Catalyst Support Durability tests consist of a series of experiment steps that execute: o Voltage sweeps and/or potentiostatic holds under H2 / N2 conditions with the 885 PSTAT for the durability portion of test, o Setup Fuel Experiments that switch anode / cathode fuels between H2 / N2 and H2 / Air depending on the experiment requirements, o Scan Current Experiments for the polarization curves with H2 / Air, o Cyclic voltammograms with the 885 PSTAT under H2 / N2 for electrochemical surface area (ECSA) measurement, o Anode and cathode humidifier temperature changes for inlet gas relative humidity (RH) control as specified in the protocol, o Open Circuit Voltage and Constant Voltage Experiments for delays after gas switching and humidifier heat-up and cool-down periods. 13. The FuelCell software setup files for Membrane Mechanical Durability consist of a series of experiment steps within nested repeat loops that execute: o Inner Repeat Loop: 360 repetitions, 2 min wet + 2 min dry (24 hour total). Contains Setup Fuel Experiments that switch anode / cathode fuels between wet (super-saturated) and dry Air with 2 min delays between switching. High flow rates are used during the RH cycling to facilitate rapid hydration and dehydration of the cell and membrane. o Outer Repeat Loop: 56 repetitions of the inner repeat loop and diagnostics (below) for total of 20,000 wet-dry cycles. o PSTAT Voltage Sweep experiment with the 885 PSTAT under H2 / N2 for the H2 Crossover measurement. o PSTAT Constant Voltage experiment with the 885 PSTAT under N2 / N2 for the shorting resistance measurement. o PSTAT Open Circuit Voltage (OCV) Experiments for delays after gas type and flow rate switching. 14. The Polarization Protocol calls for the performance curve to be measured at 150 kpaa whereas durability protocols are conducted at a different back pressure or ambient pressure (zer0 back pressure). This is possible to implement in an automated fashion with the use of Scribner s Auto Back Pressure Unit. However, the FuelCell setup files above assume that the Auto BP unit is not available and therefore all tests are conducted at ambient pressure or under fixed back pressure such as 100 kpag (15 PSIG). 15. The Unmitigated Start-Up / Shutdown Durability Protocol requires rapid purging of H2 from the cell s anode compartment with dry Air (refer to the Step 3 Shutdown in Table P.8). This is facilitated using an 850R External Interface Accessory with a 5 SLM mass flow controller (MFC) plumbed with Air. The outlet of this external MFC is plumbed directly to the cell anode inlet using a T-fitting. An example configuration of the external MFC in FuelCell is shown in below. In this example, the external MFC is connected to Reform Channel #1 on the 850R External Interface (labelled R1 ) and has a full scale flow rate of 5 SLM. The 4 rev. A, 1/2019

MFC is plumbed to the Anode, therefore it is assigned to the Anode. Display units are set to Percent. The Setup Fuel and Change Fuel Experiment windows then appear as shown in the figure below. Rapid purging of the anode compartment with dry Air during the Shutdown Step of the Start/Stop protocol is executed with a Change Fuel Experiment configured as shown, followed by a 5 second Open Circuit Experiment. 5 rev. A, 1/2019

Arbitrary Control Files (scripts) Automated Humidifier Drain / Fill Arbitrary Control Script The Automated Humidifier Drain / Fill (AHDF) procedure is used to rapidly cool the 850 humidifiers for reduced dew point testing. This is accomplished using the required Auto Humidifier Drain / Fill Valve Assembly Option as well as Arbitrary Control Experiment Steps that execute the AHDF script. Refer to the Auto Humidifier / Fill Valve Assembly Instructions. The AHDF script parameters drain time and fill time - must be determined by the user. The Arbitrary Control file arb ctrl - humidifier drain+fill x1.fcc will drain and fill each humidifier once. This is sufficient to reduce the humidifier temperature from 80 o C to ~ 60 o C, which is the desired humidifier temperature (i.e., dew point) for the DOE polarization curve protocol. The same Arbitrary Control file can be used in a Repeat Loop with 2 or 3 repeats to reduce the humidifier temperature to ~30 o C, depending on the source water temperature. DOE MEA Recovery Protocol with Arbitrary Control Script Some durability protocols call for an MEA recovery procedure after performing the durability portion of the protocol and prior to performing the respective diagnostic experiments. The Arbitrary Control file DOE MEA Recovery Protocol.fcc performs the recovery method described in Table P.9 of the MYRDDP. It can be inserted in 6 rev. A, 1/2019

The MEA recovery procedure consists of a series of anode / cathode gas types, flow rates and durations. The Arbitrary Control file is based on gases connected to the AMG as described above and that the tests stand s mass flow controllers are sized to meet the flow rates called for in the protocol, i.e., 2 SLM on anode and 4 SLM on cathode. Disclaimer Scribner does not claim that the FuelCell setup files are error free and assumes no liability for damage that may occur as a result of their use. Users should carefully review the experiment list and have a clear understanding of the purpose and function of each experiment step. Please contact Scribner (fuelcellsupport@scribner.com or +1-910-695-8884) if you have any questions. If you find an error or an improved method of implementing these protocols in FuelCell, please let us know by emailing fuelcellsupport@scribner.com. References 1. Fuel Cell technologies Office, U.S. DOE, Multi-Year, Research, Development and Demonstration Pan (MYRDDP), 2016 Fuel Cells Section, https://www.energy.gov/sites/prod/files/2017/05/f34/fcto_myrdd_fuel_cells.p df (last retrieved 2018-11-19). 2. S. Zhang, X. Yuan, H. Wang, W. Mérida, H. Zhu, J. Shen, S. Wu and J. Zhang (2009) "A review of accelerated stress tests of MEA durability in PEM fuel cells," International Journal of Hydrogen Energy, 34, 388-404. 7 rev. A, 1/2019