Heater Surface Coating Effect on Fluidized Bed Heat Transfer Coefficient

Similar documents
EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

LAB EQUIPMENT DETAILS

Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Inclined Fluidized Bed Dryer Performance in Energy Saving Option

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

International Engineering Research Journal Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe.

International Journal of Informative & Futuristic Research ISSN (Online):

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Cassava Chip Drying by Using a Small-Scale Hot-Air Microwave Oven

Design and Experimental Studies on Modified Solar Dryer

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Drying Parawood with Superheated Steam

Variable far infrared radiation (VFIR) technique for cubic carrot drying

I. INTRODUCTION. Types of Fins:

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

Modification of Passivation Unit in Galvanizing Line

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

American International Journal of Research in Science, Technology, Engineering & Mathematics

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Assistant Professor),( Professor), Department of Mechanical Engg., B.I.T. Sindri 3. Professor, Department of Mechanical Engg., N.I.T.

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Experimentation of Heat Pipe Used In Nano-Fluids

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Numerical Simulation of Window Air Conditioner

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

Measurement of Drying Rates in a Domestic Scale Fluidized Bed Dryer

Performance Study of Triple Concentric Pipe Heat Exchanger

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Effect of Magnetic Field on Convective Drying Of Ceramic Clay

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Purdue e-pubs. Purdue University

PERFORMANCE OF GEOSYNTHETICS IN THE FILTRATION OF HIGH WATER CONTENT WASTE MATERIAL

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Performance of Geosynthetics in the Filtration of High Water Content Waste Material

Drying Kinetics and Inversion Temperature in a Low-Pressure Superheated Steam-Drying System

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Solar Drying Techniques And Performance Analysis: A Review

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

Refrigeration Cycle Demonstration Unit R633

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Corn drying experiments by pilot dryer

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

Compression of Fins pipe and simple Heat pipe Using CFD

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Research Article. Analysis of moisture content of pulses pellets using fluidized bed dryer

An experimental study of the impact of tunnel suppression on tunnel ventilation

Induction heating with the ring effect for injection molding plates

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Heat transfer and heating rate of food stuffs in commercial shop ovens

Vapour Jet Refrigerator / Heat Pump R853

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Raman et al., International Journal of Advanced Engineering Technology E-ISSN

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

CFD Analysis of Co-current Spray Dryer with Swirler at Air Inlet

Transcription:

Heater Surface Coating Effect on Fluidized Bed Heat Transfer Coefficient A. P. Patil *, Gonmei Bosco 1, Joel Keishing 1, Bankerlang Narry 1 and Jopphar Kharraswai 1 ABSTRACT * corresponding author, Department of Mechanical Engineering, S. V. National Institute of Technology, Surat-395 007, India E-mail: patilap00@yahoo.co.in The effect of different coatings painted on the heat transfer surface of the horizontal heater in a vertical fluidized bed heat transfer unit is studied. Polyurethane and polyurethane based zinc coatings are applied on the horizontal heat transfer surfaces and their effects on the heat transfer coefficient are investigated for different heater heights, different heater heat inputs and for different superficial velocities. It is found that the application of polyurethane coatings has decreased the heat transfer coefficient as compared to the heat transfer coefficient obtained with the bare uncoated heater. It is also found that by applying the polyurethane based zinc coatings the heat transfer coefficient has increased as compared to that obtained with the polyurethane coating. Procedure and the results of the experiments done to study this fluidized bed heat transfer analysis are presented in this paper. Keywords: Fluidisedbed heat transfer coefficient, solid-gas flow, heater surface coating, superficial velocity Nomenclature H H or HH: Height of the heater from the reference line 1. INTRODUCTION Fluidized bed heat transfer devices such as fluidized bed boilers, dryers etc. have gained popular acceptance because they have demonstrated that they can burn a wide variety of solid fuels efficiently and in an environmentally acceptable manner. The heat transfer coefficient from the solid-gas two-phase flow to the immersed surface in the fluidized bed is an important parameter in overall equipment design and in ensuring efficient operation and control. Following information is available in the research papers [1-13] viz. the effect of fluid velocity on heat transfer, the effect of the thermal conductivity of the solid and the fluid on the heat transfer coefficient, the effect of the specific heat of the solid particles and the fluid on the heat transfer coefficient at various operating parameters, the influence of the fluid bed 1 Department of Mechanical Engineering, North-Eastern Regional Institute of Science & Technology [NERIST], Nirjuli-791 109, Itanagar, Arunachal Pradesh. height, the length of the heat transfer surface, the heat transfer tube diameter, the ratio of the tube bundle spacing to the tube diameter in vertical and horizontal tube bundles on the heat transfer coefficient, the influence of the bed pressure and the temperature on the gas convective heat transfer component and the particle convective heat transfer component. In this paper, the effects of the different coatings applied on the heat transfer surface of the horizontal heater in a vertical fluidized bed chamber are studied. Different coatings are applied on the horizontal heater in the vertical fluidized bed chamber and their effects on the fluidized bed heat transfer coefficient are studied and are putforth in the present paper. 2. EXPERIMENTAL SETUP The schematic diagram of the experimental setup is shown in Fig. 1. Bed of fused alumina (white aluminium oxide of average particle size 250 µm and density 3770 kg / m 3 ), about 0.08m height, was contained in a vertical glass cylinder of 0.105 m internal diameter and 0.22 m height. At the lower end of the cylinder a distribution chamber and an air distributor were affixed to ensure uniform airflow into the bed without causing excessive pressure drop. On leaving the bed, the air was made to pass through the chamber and then the air escaped to the atmosphere through a filter. The chamber, filter and the distributor assembly were suspended from a bracket mounted on the panel. In this bracket, probes for temperature and pressure measurement, a horizontal cylindrical heating element were accommodated in such a way that they can be moved vertically to any level in the bed chamber. Air from the compressor was delivered through a filter, an air flow meter fitted with a control valve and an orifice plate to the distribution chamber. A variable transformer was used to control the heat transfer rate from the horizontal heating elements. All the heating elements used for the experimentations were basically cylindrical copper sleeved resistance heaters of 0.0158 m diameter and 0.050 m length on which different coatings were applied. The specifications of these heaters used for the investigations are given in Table 1.

Table 1. Specifications of the heaters used for the experimentations Heater Specifications No. 1 Bare heater of 0.0158 m diameter 0.050 m length, with no coating over it 2 heater of 0.0158 m diameter 0.050 m length, with polyurethane coating of 0.000115 m 3 heater of 0.0158 m diameter 0.050 m length, with polyurethane coating of 0.000215 m 4 heater of 0.0158 m diameter 0.050 m length, with polyurethane based zinc coating of 0.00023 m 5 heater of 0.0158 m diameter 0.050 m length, with polyurethane based zinc coating of 0.0003 m Coatings for heater 4 and 5 were prepared by addition of zinc metal powder (Merck Ltd., Mumbai) of average size ~ 45 µm in polyurethane paint (Asian Paints (I) Ltd., Mumbai) and the concentration of the zinc powder in polyurethane paint was 3.94 gm of zinc powder per 1 gm of polyurethane paint. The mixture of zinc powder and polyurethane paint was thoroughly mixed and then applied on the heater surfaces. Enough care was taken to apply the coating uniformly over the whole heating surface. After applying the coatings, the coated heaters were allowed to dry completely. When the heaters were dried completely, the thickness of the coating was determined with the help of Micrometer (Mitotoyo Corporation, Tokyo). Voltmeter (0 250 V) and Ammeter (0 3 A) were used to display the voltage and current taken. The surface temperature of the heating element was measured with the help of thermocouple bids pasted on the heating element surface underneath the coating as shown in Fig. 1. A digital temperature indicator with a selector was used to indicate the temperatures of the heating element, the air supplied to the distributor and the bed. The pressure of the air at any level in the bed chamber was measured with the help of a liquid filled manometer. An excess pressure relief device was used if pressure rose above 0.030 m of H 2 O. Here it is to be noted that the thicknesses of the coatings were chosen very carefully to study the heat transfer phenomenon. 3. EXPERIMENTAL PROCEDURE Air from the compressor was allowed to pass through the chamber and its superficial velocity was noted. The electric heater was powered and its heating inputs were noted in terms of Volts and Amperes readings from the Voltmeter and Ammeter. Temperatures of the heating element, bed and the air supplied were taken from the digital temperature indicator. By varying the superficial velocity and the heater heat input following fluidized bed heat transfer analysis has been done: 1. Study of the heat transfer coefficient associated with the bare cylindrical heater (with no coating over it) i. e. Heater 1 only: effect of the heater height on the heat transfer coefficient has been studied. For different heights of the heater, the superficial velocity and the heater heat input were varied; the heat transfer coefficient values have been found out and are plotted in Fig. 2. 2. Study of the effect of the coatings, applied on the heaters i. e. heater 2 5, on the heat transfer coefficient: Individual heaters were affixed inside the fluidized bed chamber one by one and the analysis has been done as below: Study of the effect of the heater height H H on the heat transfer coefficient for different heat inputs and for different superficial velocities has been done. For the heaters, heater 2 heater 5, H H was varied and the effect of heater height on the heat transfer coefficient was investigated, the heat transfer coefficient values have been found out and are shown in Fig. 3 to Fig. 6. 4. OBSERVATIONS AND DISCUSSION Comparison of the results of the heat transfer studies has been done and is given in Table 2. Considering the Fig. 2 Fig. 6, for all the cases i. e. the case of the bare heater (heater 1) and the cases of the heaters painted with coatings (heater 2 heater 5), it is concluded that the heat transfer coefficient increases with the increase in the heater heat input and the superficial velocity and the heat transfer coefficient decreases by increasing the heater height H H. The comparison of the experimental data of the heat transfer coefficient values between the cases of the heaters painted with polyurethane coatings i. e. heater 2 and heater 3 is given in Fig. 7. From Fig. 7, it is concluded that, with the increase in the coating thickness of polyurethane, the heat transfer coefficient values have decreased. Similarly, the comparison of the experimental data of the heat transfer coefficient values between the cases of the heater painted with polyurethane based zinc coatings i. e. heater 4 and heater 5 is given in Fig. 8 Fig. 9 and it is observed from these figures that with increase in the polyurethane based zinc coating thickness, the heart transfer coefficient values have also increased. The comparison of the experimentally found heat transfer coefficient values among the bare heater, the polyurethane painted heater with 0.00215 m thickness and the heater painted with polyurethane based zinc coating of thickness 0.0003 m is portrayed in Fig. 10 (for heater height 0.11m) and Fig. 11 (for heater height 0.13 m). From Fig. 10 and Fig. 11, it is inferred that the heat transfer coefficient

Table No. 2 Comparison of the results of the heat transfer studies Cases studied Attributes Comments and Discussion A. Study of the effect of the heater height on the heat transfer 0.15 m. From the Fig. 2, it is concluded that the heat transfer coefficient has increased as the heater heat input and the superficial coefficient for the superficial velocity were velocity have increased. Also it has been bare cylindrical varied. found that, as the heater height increases heater alone B. Study of the case of the heater 2 which is painted with polyurethane coating of thickness 0.000115m. C. Study of the case of the heater 3 which is painted with polyurethane coating of thickness 0.000215m. D. Study of the case of the heater 4, which is painted with polyurethane, based zinc coating of thickness 0.00023 m. E. heater of 0.0158 m diameter 0.050 m length, with polyurethane based zinc coating of 0.0003 m thickness over the heating surface 0.15 m superficial velocity were varied. 0.15m superficial velocity were varied. 0.15m superficial velocity were varied. heater of 0.0158 m diameter 0.050 m length, with polyurethane based zinc coating of 0.00023 m thickness over the heating surface the heat transfer coefficient decreases. From the Fig. 3, it has been found that, by increasing the heater height the heat transfer coefficient decreases. The heat transfer coefficient has increased as the heater heat input and the superficial velocity have increased. It has been inferred form Fig. 4, the heat transfer coefficient decreases with increase in the heater height H H. The increase in the heater heat input and the superficial velocity resulted in increase in the heat transfer coefficient. From the Fig. 5 it has been concluded that, the increase in the H H has resulted in decrease in the heat transfer coefficient. Increase in the superficial velocity and the heater heat input has resulted in increase in the heat transfer coefficient. It is found from Fig. 6 that the heat transfer coefficient increases with the increase in the heater heat input and the superficial velocity and decreases with the increase in the H H. values obtained with the heater coated with the polyurethane based zinc coating are more than those obtained with the heater with only polyurethane coating. Comparison of the heat transfer coefficient values between the bare heater and the heater coated with polyurethane based zinc coating i. e. heater 5 shows that, the heat transfer coefficient values for the heater painted with the polyurethane based zinc coating are lower than those of the bare heater. But the rate of increase of heat transfer coefficient values with the superficial velocity for the heater coated with the polyurethane based zinc coating of thickness 0.0003 m is same as that of the bare heater at H H 11 m (for 17.25 W and 22.5 W heater heat input) and at H H 0.13 m. The heat transfer coefficient values obtained with the polyurethane coated heater are lower than those obtained with the bare heater. It is concluded from this experimental investigation of carefully chosen coating thicknesses that, the coating of polyurethane has offered thermal resistance to the heat transfer while the inclusion of zinc in polyurethane has overcome this heat resistive effect and together with the phenomenon of boundary layer (which couldn t be studied here in detail), heater with the polyurethane based zinc coating gave the higher values of the heat transfer coefficient as compared to those obtained with the polyurethane coated heater. In the present study, effect polyurethane based zinc coating of only concentration i. e. 3.94 gm of zinc powder per 1 gm of polyurethane paint, was investigated. Effect different coating concentrations for the same coating thickness, on the heat transfer properties are to be analyzed for thorough understanding. Also more experimental data for different coatings of various thicknesses and various coating concentrations is needed for wide range of experimental variables.

5. CONCLUSION Experimental assessment is done to find out the possibility of the application of the different coatings over the heat transfer surface of the horizontal heater to increase the vertical fluidized bed heat transfer coefficient. Different thicknesses of polyurethane coating and polyurethane based zinc coating are applied and their effect on the heat transfer coefficient with increase in the superficial velocity, heater heat input and the heater height are investigated. In order to analyse the phenomenon of heat transfer, thicknesses are chosen wisely and it is fount that, the application of polyurethane coating has rendered thermal resistance, thus decreasing the values of the heat transfer coefficient. Also by increasing the polyurethane coating thickness, the heat transfer coefficient values have decreased. In the case of heaters with polyurethane based zinc coatings, with increase in the thickness of polyurethane based zinc coating the heat transfer coefficient has increased. Heat transfer coefficient values for the heater painted with polyurethane based zinc coating are lower than those obtained with the bare heater but higher than those obtained with the polyurethane coated heater. The reason for this can be attributed to the addition of zinc, which has overcome the thermal resistance offered by polyurethane and the boundary layer phenomenon. More experimental analysis of the system along with the detail study of boundary layer phenomenon, for different coatings of various thicknesses and various coating concentrations is required. ACKNOWLEDGEMENT Special thanks are due to Prof. B. Gogoi, Prof. R. Subadar, Prof. Lourembam Lolit Kr. Singh and R & AC-2002 group for their help that has eased up the carrying out of the work. [7] Basakov, A. P., 1968, High speed non oxidative heating and heat treatment in a fluidized bed, Metallurgia (Moscow). [8] Vreedenberg, H. A., 1952, Heat transfer between fluidized beds and vertically inserted tubes, J. Appl. Chem., 2 (Suppl. Issue), 26. [9] Brotz, W., 1956 Utersuchungen uber transportvorgange in durchstrometem gekontem Gut, Chem. Ing. Techn., 28, 165. [10] Basakakov, A. P. and Berg, B. V., 1966, Inzh. Fiz Zh. Akad. Nauk Belorussk SSR6, 8, 3. [11] Botterill, J. S. M., Teoman, Y. and Yüregir, K. R., 1984, Temperature effect on the heat transfer behaviour of gas fluidized beds, AIChE Symp. Ser,. 77 (208), 330. [12] Xavier, A. M. and Davidson, J. F., 1985, Convective heat transfer in fluidized bed, in Fluidization, 2 nd ed., Davidson, J. F,. Clift, R. and Harrison, D,. Eds, Academic Press, London, Chap. 13. [13] Gelprin, N. I. and Einstein, V. G., 1971, Heat Transfer in fluidized beds, in Fluidization, Davidson, J. F. and Harrison, D., Eds., Academic Press, New York, Chap. 10. Legends for the figures H H or HH: Height of the heater from the reference line 1. H H 2.Heater 3.Bed 4.Thermocouple bid 5.Coating 6.to digital display 6 REFERENCES 4 4 [1] Sarkits, V. B., 1959, Heat Transfer from Suspended Beds of Granular Materials to Heat Transfer Surfaces (Russian), Leningrad Technol. Inst., Lensovieta. [2] Miller, C. O. and Logwink, A. K,. 1951, Fluidization studies of solid particles, Ind. Eng. Chem., 43, 1220. [3] Wicke, E. and Hedden, F,. 1952, Stromungsformen and wameubertrangung in von luft aufgewirbelten schuttgutschichten, Chem. Ing. Tech., 24 (2), 82. [4] Dow, W. M. and Jackob, M., 1951, Heat Transfer between a vertical tube and a fluidized bed air mixture, Chem. Eng. Prog., 47, 637. [5] Gaffney, B. J. and Drew, T. B., 1950, Mass tarnsfer from packing to organic solvents in single phase flow through a column, Ind. Eng. Chem., 42, 1120. [6] Traber, P. G., Pomaventsev, V. M,. Mukhenov, I. P. and Sarkits, V. B., 1962, Heat transfer from a suspended layer of catalyst to the heat transfer surface, Zh. Prikl. Khim., 35, 2386. 6 2 3 4 Fig. 1. Schematic of the Experimental Setup 1 5 Heater crosssection 2

450 400 350 300 250 200 150 100 HH 0.11 m, 1W HH 0.11 m, 17.25 W HH 0.13 m, 1 W HH 0.13 m, 17.25 W HH 0.15 m, 1 W HH 0.15 m, 17.25 W HH 0.11 m, 7.5 W HH 0.11 m, 22.5 W HH 0.13 m, 7.5 W HH 0.13 m, 22.5 W HH 0.15 m, 7.5 W HH 0.15 m, 22.5 W 0.12 0.14 0.16 0.18 0.2 Fig. 2. Variation of heat transfer coefficient with superficial velocity for the bare cylindrical heater only 440 390 290 190 Heater 2, HH 0.11 m, 7.5 W Heater 2, HH 0.11 m,22.5 W Heater 2, HH 0.13 m,17.25 W Heater 2, HH 0.15 m,7.5 W Heater 2, HH 0.15 m,22.5 W Heater 2, HH 0.11 m,17.25 W Heater 2, HH 0.13 m,7.5 W Heater 2, HH 0.13 m,22.5 W Heater 2, HH 0.15 m,17.25 W 90 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 Fig. 3. Variation of heat transfer coefficient with superficial velocity for the case of heater 2 i. e. the heater painted with polyurethane coating of thickness 0.000115 m heat transfer coefficient W m 2 K 3 2 0 2 7 0 2 2 0 1 7 0 1 2 0 H e a te r 3, H H 0. 1 1 m, 7. 5 W H e a te r 3, H H 0. 1 1 m, 1 7. 2 5 H e a te r 3, H H 0. 1 3 m, 7. 5 W H e a te r 3, H H 0. 1 3 m, 1 7. 2 5 W H e a te r 3, H H 0. 1 5 m, 7. 5 W h e a te r 3, H H 0. 1 5 m, 1 7. 2 5 W 7 0 0. 1 2 5 0. 1 3 5 0. 1 4 5 0. 1 5 5 0. 1 6 5 0. 1 7 5 0. 1 8 5 0. 1 9 5 s u p e r f i c i a l v e l o c i t y m / s Fig. 4. Variation of heat transfer coefficient with superficial velocity for the case of the heater 3 i. e. the heater painted with polyurethane coating of thickness 0.000215 m

325 275 225 175 125 Heater 4, mhh 0.11 m, 7.5 W Heater 4, HH 0.11 m, 17.25 W Heater 4, HH 0.11 m, 22.5 W Heater 4, HH 0.13 m, 7.5 W Heater 4, HH 0.13 m, 17.25 W Heater 4, HH 0.13 m, 22.5 W 440 390 290 190 Heater 2, HH 0.11 m, 7.5 W Heater 2, HH 0.11 m, 17.25 W Heater 2, HH 0.13 m,7.5 W Heater 2, HH 0.13 m,17.25 W Heater 3, HH 0.11 m,7.5 W Heater 3, HH 0.11 m,17.25 Heater 3, HH 0.13 m,7.5 W Heater 3, HH 0.13 m, 17.25 W 75 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 Superficial velocity m / s Fig. 5. Variation of heat transfer coefficient with superficial velocity for the case of the heater 4 i. e. the heater painted with polyurethane based zinc coating of thickness 0.00023 m 90 0.125 0.135 0.145 0.155 0.165 0.175 0.185 0.195 Fig. 7. Comparison of variation of heat transfer coefficient values with superficial velocity between the heater 2 and heater 3 i. e. the heaters painted with polyurethane coating with thicknesses 0.000115 m and 0.000215 m heat transfer coefficient W/m 2 K 100 200 300 400 Heater 5, HH 0.11m, 7.5 W Heater 5, HH 0.11 m, 17.25 W Heater 5, HH 0.13 m, 7.5 W Heater 5, HH 0.13 m, 17.25 W 0.12 0.14 0.16 0.18 0.2 Superficial Velocity m/s Fig. 6. Variation of heat transfer coefficient with superficial velocity for the case of the heater 5 i. e. painted with polyurethane based zinc coating of thickness 0.0003 m 320 300 280 260 220 200 180 Heater 5, HH 0.11 m, 7.5 W Heater 4, HH 0.11 m, 7.5 W Heater 5, HH 0.11 m, 17.25 W Heater 4, HH 0.11m, 17.25 W 0.125 0.145 0.165 0.185 superficial velocity m/s Fig. 8. Comparison of variation of the heat transfer coefficient values with superficial velocity between the heater 4 and heater 5 i. e. the heaters painted with polyurethane based zinc coating with thicknesses 0.00023 m and 0.0003 m at HH 0.11m.

Heater 5, 7.5 W Heater 5, 17.25 W 220 Heater 5, 22.5 W 200 180 160 120 100 80 9 Heater 4, 7.5 W Heater 4, 17.25 W Heater 4, 22.5 W 0.125 0.145 0.165 0.185 superficial velocity m/s Fig. 9. Comparison of variation of the heat transfer coefficient values with superficial velocity between the heater 4 and heater 5 i. e. the heaters painted with polyurethane based zinc coating with thicknesses 0.00023 m and 0.0003 m at HH 0.13m Heater 1, 7.5 W heater 3, 7.5 W Heater 5, 7.5W Heater 1, 17.25 W Heater 3, 17.25 W Heater 5, 17.25 W Heater 1, 22.5 W 290 190 90 Heater 5, 22.5 W 0.125 0.145 0.165 0.185 superficial velocity Fig. 11. Comparison of the variation of heat transfer coefficient values with superficial velocity among the heater 1 (bare heater), heater 3 (polyurethane coated heater) and heater 5 (heater painted with polyurethane based zinc coating), for HH 0.13 m Heater 1, HH 0.11 m, 7.5 W Heater 3, HH 0.11 m, 7.5 W Heater 1, HH 0.11 m, 17.25 W Heater 3, HH 0.11 m, 17.25 W 480 Heater 5, 7.5 W Heater 5, 17.25 W 430 380 330 280 230 180 130 0.125 0.135 0.145 0.155 0.165 0.175 0.185 Fig. 10. Comparison of the variation of heat transfer coefficient values with superficial velocity among the heater 1 (bare heater), heater 3 (polyurethane coated heater) and heater 5 (heater painted with polyurethane based zinc coating), for HH 0.11 m.