Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Similar documents
Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Fire resistance test on fire collars protecting a concrete slab penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

BS EN ISO : 2010

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

Test Report: ICL/CR15/11/087

BS EN ISO : 2010

IMO Resolution MSC 61(67): Annex 1: Part 2

BS EN ISO : 2010

Classification of Fire Performance of Wall and Ceiling Lining Materials

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Review Fire Test Report

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BCTC CARPET TECHNICAL CENTRE

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Analysis Report

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS 476: Part 6: 1989+A1:2009

AS/NZS 4012:1999 AS/NZS

BS 476: Part 6: 1989+A1:2009

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Australian Standard. Components for the protection of openings in fire-resistant walls. Part 1: Fire-resistant doorsets AS AS 1905.

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

BS EN : 2001 & IEC :2000

MEDIUM-DENSITY HOUSING # 7. Fire safety

NF X : Parts 1, 2, 3, 4 & 5

Test Report: ICL/H18/9039 Rev 1

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Report VNLF Test Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CERTIFICATION SAFETY & BEYOND

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

Australian/New Zealand Standard

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

New European Fire Testing Classification for Construction Products

Abrasion Resistance of Fluoropolymer and polyester Coatings

Australian/New Zealand Standard

Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

INTERNATIONAL STANDARD

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

SLIP RESISTANCE TESTING OF ENDURO-MESH PANEL

Information Bulletin

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Australian/New Zealand Standard

AS/NZS :2014

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Australian/New Zealand Standard

Australian/New Zealand Standard

Australian/New Zealand Standard

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Australian/New Zealand Standard

Test Report to AS/NZS :2015. Report No. T160402_S

Loss Prevention Standard

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

Are Your Kitchen Hood Filters Compliant?

Australian/New Zealand Standard

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

AS/NZS IEC :2015

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Australian/New Zealand Standard

Analysis Report

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Alarm Signalling Equipment: Connection Requirements (Victoria) TAN 06. Technical Advisory Note. Version 1 October 2018

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

Medical electrical equipment

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

This document is a preview generated by EVS

Australian/New Zealand Standard

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

Aon Sprinkler Certification Technical Note

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

AS Australian Standard. Guards and patrols. This is a free 6 page sample. Access the full version online.

Transcription:

INFRASTRUCTURE TECHNOLOGIES Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in accordance with AS/NZS 3837:1998 Fire Testing Report Author: Heherson Alarde Report Number: FNK 11494 Quote Number: NKI 7440 Date: 20 October 2015 Version: A Client: Steadiform Pty Ltd Commercial in confidence NATA Accredited Laboratory Number: 165 Corporate Site No 3625 Accredited for compliance with ISO/IEC 17025.

Enquiries Enquiries should be addressed to: Team Leader, Fire Testing and Assessments Infrastructure Technologies 14 Julius Avenue North Ryde, NSW 2113 Australia Telephone +61 2 94905444 Author Infrastructure Technologies 14 Julius Avenue North Ryde, NSW 2113 Australia Telephone +61 2 94905445 Client Steadiform Pty Ltd 110 Nojoor Road MUDJIMBA QLD 4564 AUSTRALIA Test Report Details Document: Fire Testing Report Test Standard: AS/NZS 3837:1998 at 50 kw/m² irradiance Client: Steadiform Pty Ltd Quote Number: NKI 7440 Test Report Status and Revision History VERSION STATUS DATE DISTRIBUTION COMMENT ISSUE NO. Draft Draft for internal review 20 October 2015 A Final for issue 20 October 2015 CSIRO CSIRO Draft Steadiform Pty Ltd FNK 11494 Test Report Authorisation AUTHOR REVIEWED BY AUTHORISED BY Heherson Alarde Russell Collins Brett Roddy 20 October 2015 20 October 2015 20 October 2015 Use of this Report Use of Reports Testing This report is subject to binding obligations under which it was prepared. In particular, the Report must not be used: as a means of endorsement; or in a company prospectus or notification to a Stock Exchange document for capital raising, without the prior written consent of CSIRO. The Report may be published verbatim and in full, provided that a statement is included on the publication that it is a copy of the Report issued by CSIRO. Excerpts of the Report may not be published without the prior written consent of CSIRO. Copyright and disclaimer 2015 CSIRO To the extent permitted by law, all rights are reserved and no part of this publication covered by copyright may be reproduced or copied in any form or by any means except with the written permission of CSIRO. Important disclaimer CSIRO advises that the information contained in this publication comprises general statements based on scientific research. The reader is advised and needs to be aware that such information may be incomplete or unable to be used in any specific situation. No reliance or actions must therefore be made on that information without seeking prior expert professional, scientific and technical advice. To the extent permitted by law, CSIRO (including its employees and consultants) excludes all liability to any person for any consequences, including but not limited to all losses, damages, costs, expenses and any other compensation, arising directly or indirectly from using this publication (in part or in whole) and any information or material contained in it.

Contents 1 Summary... 1 2 Test Details... 1 2.1 Sample Identification... 1 2.2 Sponsor... 1 2.3 Manufacturer... 1 2.4 Job Number... 1 2.5 Test Date... 1 2.6 Description of Sample... 1 2.7 Documentation... 2 3 Method... 2 3.1 Conditioning of Specimens... 2 3.2 Test Method... 2 3.3 Departure from Standard... 2 3.4 Duration of Test... 2 4 Results and Observations... 3 Observations... 3 4.2 Results of Tests... 4 5 Assessment Certificate... 7 Tables Table 1 Results of test... 4 Figures Figure 1 Heat Release Rate (HRR)... 5 Figure 2 Effective Heat of Combustion (EHC)... 6 Figure 3 Certificate of Assessment 2238... 7 FNK 11494, A i

1 Summary Sponsored Investigation Report Number FNK 11494 Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in accordance with AS/NZS 3837:1998 2 Test Details 2.1 Sample Identification Steadiform H Sample 2.2 Sponsor Steadiform Pty Ltd 110 Nojoor Road MUDJIMBA QLD 4564 AUSTRALIA 2.3 Manufacturer Steadiform Pty Ltd 110 Nojoor Road MUDJIMBA QLD 4564 AUSTRALIA 2.4 Job Number NKI 7440 2.5 Test Date 8 October 2015 2.6 Description of Sample The sponsor described the tested specimen as extruded rigid polyvinyl chloride (PVC) profile used as permanent formwork for concrete walls. The rigid PVC profile formed the exposed face of the tested specimen and was laid onto the horizontal surface of the concrete substrate and allowed to dry. Nominal thickness of PVC facing: Nominal total thickness: Nominal mass of PVC facing: Nominal total mass: Colour: 3 mm 50 mm 3.8 kg/m² 115 kg/m² off white (PVC) FNK 11494, A 1

2.7 Documentation The following documents were supplied by the sponsor as a full and complete description of the sample: Test Agreement and form FTAF33 dated 27 August 2015. 3 Method 3.1 Conditioning of Specimens Prior to the test, the specimens were conditioned to constant mass at a temperature of 23 2 C and a relative humidity of 50 10%. 3.2 Test Method Tests were performed in accordance with Australian/New Zealand Standard 3837:1998 Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter. All test specimens were exposed in the horizontal orientation with the standard pilot operating. Nominally 100 x 100 mm specimens were tested as supplied. Specimens were tested with the use of an edge frame. The edge frame reduces the test surface area to 0.0088 m². The specimens were restrained with a wire grid which further reduced the test surface area to 0.0081 m 2, and this is the area used in calculations. For the test, specimens were wrapped in aluminium foil so that the four edges and the bottom of the specimen were covered. The foil formed a shallow tray that retained any molten material during testing. Three specimens were tested at an irradiance level of 50 kw/m². The nominal exhaust system flow rate for all tests was 0.024 m³/s. A measured quantity of ethanol was burnt to obtain a C factor to be used in the Heat Release calculations. 3.3 Departure from Standard In performing heat release rate calibration to determine the orifice constant, C, an alternative procedure was employed as specified in Clause 10.2.4 of ISO 5660 1:2002(E) by burning a measured quantity of absolute ethanol. 3.4 Duration of Test The test is terminated when any one of the following is applicable: 1. 2 minutes have passed since all flaming from the specimen ceased; and 2. the average mass loss over a 1 minute period has dropped below 150 g/m²; 3. 60 minutes have elapsed; or 4. the specimen fails to ignite after a 10 minute exposure. Note: The mass loss test end criterion was not used for this test. 2 FNK 11494, A

4 Results and Observations Observations 4.1.1 SPECIMEN 1 The specimen began to smoke after 19 seconds exposure to the test. Some flashing occurred prior to ignition. The specimen ignited during the test. The test was terminated when two minutes had passed since all flaming from the specimen ceased. 4.1.2 SPECIMEN 2 The specimen began to smoke after 17 seconds exposure to the test. Some flashing occurred prior to ignition. The specimen ignited during the test. The test was terminated when two minutes had passed since all flaming from the specimen ceased. 4.1.3 SPECIMEN 3 The specimen began to smoke after 19 seconds exposure to the test. Some flashing occurred prior to ignition. The specimen ignited during the test. The test was terminated when two minutes had passed since all flaming from the specimen ceased. FNK 11494, A 3

4.2 Results of Tests The results of tests as specified in the Standard are summarised in Table 1. Test Details: Date of test: 08/10/15 Test Report Date: 20/10/15 Ethanol burn ('C' factors): 0.038430 Table 1 Results of test IRRADIANCE (kw/m²) TIME TO SUSTAINED BURNING (s) TEST DURATION (s) THICKNESS (mm) SPECIMEN MASS (g) MASS REMAINING (g) MASS LOSS (g) PERCENT OF MASS PYROLYSED (%) AVERAGE RATE OF MASS LOSS (g/m².s) PEAK HRR (kw/m²) AVERAGE HRR (FIRST 60s AFTER IGN) AVERAGE HRR (FIRST 180s AFTER IGN) AVERAGE HRR (FIRST 300s AFTER IGN) TOTAL HEAT RELEASED (MJ/m²) AVERAGE EHC (MJ/kg) AVERAGE SPECIFIC EXTINCTION AREA (m²/kg) Sample 1 50 157 375 50 1147.38 1134.18 13.20 1.15 5.43 99.5 80.0 45.1 n/a 8.85 5.43 410.9 Sample 2 50 133 350 50 1200.21 1187.41 12.80 1.07 5.08 89.3 76.7 46.7 n/a 10.60 6.71 397.6 Sample 3 50 167 395 50 1121.38 1108.58 12.80 1.14 5.03 88.7 72.3 47.2 n/a 10.84 6.86 399.8 Mean 152.3 373.3 1156.3 1143.4 12.9 1.1 5.2 92.5 76.3 46.3 10.1 6.3 402.8 SD 17.5 22.5 40.2 40.2 0.2 0.0 0.2 6.0 3.9 1.1 1.1 0.8 7.1 Notes: 1. The results of this fire test may be used to directly assess fire hazard, but it should be recognised that a single test method will not provide a full assessment of fire hazard under all fire conditions. 2. As per Section 9 (n) of AS 5637.1:2015, the determination of the group number was based on the AS/NZS 3837:1998 test, and was deemed valid in the cone calorimeter for the assignment of National Construction Code (NCC) group number. 4 FNK 11494, A

Figure 1 Heat Release Rate (HRR) FNK 11494, A 5

Figure 2 Effective Heat of Combustion (EHC) 6 FNK 11494, A

5 Assessment Certificate Figure 3 Certificate of Assessment 2238 FNK 11494, A 7

CONTACT US t 1300 363 400 +61 3 9252 6000 e enquiries@csiro.au w www.csiro.au YOUR CSIRO Australia is founding its future on science and innovation. Its national science agency, CSIRO, is a powerhouse of ideas, technologies and skills for building prosperity, growth, health and sustainability. It serves governments, industries, business and communities across the nation. FOR FURTHER INFORMATION Infrastructure Technologies Heherson Alarde Fire Testing Engineer t +61 2 9490 5445 e heherson.alarde@csiro.au w www.csiro.au/organisation Structure/Divisions/CMSE/Infrastructure Technologies/Fire safety.aspx Infrastructure Technologies Brett Roddy Team Leader, Fire Testing and Assessments t +61 2 94905449 e brett.roddy@csiro.au w www.csiro.au/organisation Structure/Divisions/CMSE/Infrastructure Technologies/Fire safety.aspx 8 FNK 11494, A