MultiVac 300-MS MultiVac 300-MB MultiVac 600-MS MultiVac 600-MB MultiVac 300-MB-T MultiVac 600-MB-T Vacuum Filtration System

Similar documents
Laboratory filtration systems.

RCM-C Vinyl Cleaner. Part List: Operation conditions:

Owners Manual MINI-CLASSIC II. Pure Water. Water Distiller

original your automatic choice Socorex The Socorex original models Twin syringe = extended programme

High Output Vacuum/Pressure Pump

INSTRUCTIONS CertoClav EL

CAUTION EXPOSED SHARP OBJECTS INSIDE. HAZARDOUS MOVING PARTS DO NOT OPERATE WITH COVER OPEN. for Block Ice

ASPIRE Laboratory Aspirator

Owners Manual. Model MINI-CLASSIC CT. Pure Water. Water Distiller

LABOKLAV. Autoclaves Made in Germany

Dishwasher Installation Manual

ROTARY VACUUM EVAPORATOR RVO 004

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

RENZ FOR QUALITY PRODUCT CATALOGUE.

Manual Page 1 of 8. Manual. Laboratory autoclave

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

LABORATORY VERTICAL AUTOCLAVE

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

Vertical Laboratory Autoclave A series:

MONSTER FLOOR (SC1Z1) INSTRUCTION MANUAL. CUSTOMER SERVICE: (AUS) (NZ) Model #: SC1Z1 AUS, NZ

BRAVO AUTOCLAVES. Installation Notes. BRAVO 1 Quick Start Guide SD-402 Rev. 1.0 Copyright 2012 SciCan Ltd. All rights reserved

For more Parts Information:

Benchtop Pro with Omnitronics

PAVIA INSTALLATION GUIDE

OPERATION AND MAINTENANCE MANUAL

EN Instruction manual. gasprofi 1 SCS micro. The smallest laboratory gas burner with more safety. DIN 30665, part 1

Solids, Total Filterable (Total Dissolved)

Tornado Operations & Maintenance Manual

Vacuum Pump V-100 Technical data sheet

FLUSH WATER SAVER DUAL FLUSH KIT

Supplemental Installation & Operation Manual. THE COLDWELL Stainless Steel Cold Trap

Pure Water C-60/75 Installation Manual

Owner s Manual. Terpene Trap CF 1000

O P E R A T I N G M A N U A L

Power Direct Vent PDV(S&T) Models

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

INSTRUCTION BOOKLET. Electric Steam Sterilizer

MODEL 6430T, 6460 & 6460T POTATO PEELER

Vacuum Equipment. Manifolds. Traps. Pumps. Adapters. Easy to assemble Ace-Safe connector versions. O-Ring connections. Added safety and versatility

Science Lab Equipment

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

Bacti-cinerator Sterilizer

Chemical resistant Vacuum Pumps

USER S GUIDE IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING VACUUM CLEANER USE ONLY AS DIRECTED. WATER FILTRATION VACUUM CLEANER

IMAGE V. Parts and Service Manual

EDR Series. Model. Instruction Manual. Rev 5.0. Thank you for purchasing the EDR Auto Smart.

GLASSWARE WASHER INSTALLATION INSTRUCTIONS

Operator s Manual. The FREEDOM ROCKER. Contents. Congratulations!

B.I.C.A Built-In Coffee Appliance

KITCHEN FAUCET COS-KF222C

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

Get Cleaning... What s your Vax s model number? User Guide. Steam Cleaner. Vax Careline: AU: NZ: VSTHM1600

VERONA INSTALLATION GUIDE

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Personal Blender User guide

Rambo CAST IRON RING BURNERS OPERATING INSTRUCTIONS. C40LP 3 Ring Burner C50LP 4 Ring Burner

WATT R TWIN Energy-Efficient Home Water System

PRO 2000i LOW LEVEL DEPOSITOR

6/8 burners gas range on gas oven

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

INSTALLATION INSTRUCTIONS

6 IN 1 Compact Multifunction Food Processor

Load type and process/autoclave selection

Interior Condensing Tankless Models

1. Plug electric cord to appropriate 110V 220V electrical outlet. Push the off/on switch to fill position.

Standard Operating Procedure for Oil & Grease Method EPA1664A

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Bravo. Troubleshooting Guide

Rice Cooker GL 3056 GL User s Guide

Gas Fire Patio Heater Lhotse-817

Steam Fresh Let s get started

CHLORIDE GASES CHLORIDES

Aspirator with trap flask FTA-1

MODEL CMA-180UC PARTS MANUAL Rev 1.16

INSTRUCTIONS MANUAL. 1.8L Electric Kettle with Multi-Temp Feature SK-1800R (Red) SK-1800SS (Stainless Steel)

EZ9Plus & EZ11Plus Instructions on: Operating

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

DEVIATING VALVES ART K063

AUC Cell Washer. User Manual

DURABLE RELIABLE EFFICIENT DURABLE

Laboratory Techniques

MacDonald Steel Limited

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

Single-Control Lavatory Faucet

PERFORM Operating Document

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Owner's Manual. WS Series. Water Softener

INSTALLATION GUIDE NZ AU GB IE C

Water Circulator (Chiller) & Cold Trap

Tornado Operations & Maintenance Manual

ACCESSORIES EVO700 EVO900

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

Multi-Mode Electrode pro

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

Description of a Standard 125 ml Separatory Funnel

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

Transcription:

MultiVac 300-MS MultiVac 300-MB MultiVac 600-MS MultiVac 600-MB MultiVac 300-MB-T MultiVac 600-MB-T Vacuum Filtration System

Important notice The instrument shall not be modified in any way. Any modification will void the warranty and may result in potential hazard. We are not responsible for any injury or damage caused by any non-intended purposes and modifying the instrument without authorization. Unpacking When unpacking, notice if the package is complete and in good situation. If you find any damage or missing parts, please preserve serial number, shipping carton and contact your dealer for quick solution. Please discard the packing materials according to your local environmental protection policy. Model Composition Q ty MultiVac 300-MS 3-branch stainless steel manifold with #8 silicon stopper adaptor

Model Composition Q ty MultiVac 300-MB 3-branch stainless steel manifold with Rocker's funnel adaptor(without funnel) Model Composition Q ty MultiVac 600-MS 6-branch stainless steel manifold with #8 silicon stopper adaptor

Model Composition Q ty MultiVac 600-MB 6-branch stainless steel manifold with Rocker's funnel adaptor (without funnel) Model Composition Q ty MultiVac 300-MB-T 3-branch stainless steel manifold with Rocker's funnel adaptor (without funnel) Stainless Steel Funnel 100ml Rocker 400, Oil Free Vacuum Pump, AC220V, 50Hz Dragon 100, Torch Burner Heavy Duty PP Waste Bottle 4000ml with draining PALL, GN-6 Metricel Membrane Disc Filter, grid, 47mm, 0.45 um, 200/PK Silicone Tube(φ6x12mm),100cm Dragon 100 x 3 x 2

Model Composition Q ty MultiVac 600-MB-T 6-branch stainless steel manifold with Rocker's funnel adaptor(without funnel) Stainless Steel Funnel 100ml Rocker 400, Oil Free Vacuum Pump, AC220V, 50Hz Dragon 100, Torch Burner Heavy Duty PP Waste Bottle 4000ml with draining PALL, GN-6 Metricel Membrane Disc Filter, grid, 47mm, 0.45 um, 200/PK Silicone Tube(φ6x12mm),100cm Dragon 100 x 6 x 2

Installation and Operation Attention MultiVac manifold can connect with vacuum pump for the filtration. It is always recommended to install a waste bottle between the manifold and vacuum pump to prevent water from flowing into the vacuum pump. The direction of the outlet of MultiVac manifold is interchangeable. You can disassemble the outlet by hand or tool to change the direction into your desired position. The adjustable vent valve design can avoid Water Hammer and help to drain residual liquid o the tube. Operation Make sure all valves are off before use, rotate the valves counterclockwise to up position for filtration. On Off If water hammer effect happens during filtration, adjust the vent valve until smooth. After filtration, turn the vent valve counter-clockwise to draw out the remaining liquid if necessary. Off On

The flexible filtration head design make funnel adaptor convertible and user can change funnel adaptor to fit to Rocker s stainless steel funnel or other major brands disposable funnels easily. Tighten fixing screw with L-Type hex key (2mm) to prevent support base from rotation. Replace the base adaptor

Installation with Filter Holder Adaptor for Silicone Stopper funnel adaptor Rocker s stainless steel funnel Adaptor Adaptor for Pall 4870 (100ml), 4871 (250ml) - lter funnel Millipore MIACFD101 (100ml), MIACFD201 (250ml) plastic Adaptor for Sartorius 16A07 (100ml) plastic funnel funnel

Vacuum filtration system Installation A. Follow below diagram to install the system. B. Use two silicone tubes to connect the vacuum pump, waste bottle and manifold. C. Turn on the pump and pour the sample water into the funnel and turn the valve to up position to start the filtration. System assembly diagram

Maintenance Please suck in pure water to clean the tubing after every use. MultiVac manifold and waste bottle are autoclavable. SUS316 which offer excellent chemical resistance and can be fast sterilized by flame, steam and oven etc. Silicone tube and O-ring are consumables. Please change the silicone tube and O-ring if you have air leakage problem. Replace O-ring that locates in the control valve Replace O-ring that locates in the plug Replace O-ring that locates in the outlet Replace O-ring that locates in the support base

Ordering Information 180300-00 MultiVac 300, 3 Places S.S. Manifold without funnel adaptor 180600-00 MultiVac 600, 6 Places S.S. Manifold without funnel adaptor 180300-01 MultiVac 300-MS, 3 Places S.S. Manifold with No. 8 stopper funnel adaptor 180300-02 MultiVac 300-MB, 3 Places S.S. Manifold with Rocker S.S. funnel adaptor 180600-01 MultiVac 600-MS, 6 Places S.S. Manifold with No. 8 stopper funnel adaptor 180600-02 MultiVac 600-MB, 6 Places S.S. Manifold with Rocker S.S. funnel adaptor 190100-20 Adaptor for Rocker S.S. Funnel 190100-71 Adaptor for No. 8 Stopper ( for MultiVac series manifold) 190100-73 Adaptor for Millipore MIACFD101 (100ml), MIACFD201 (250ml) plastic funnel 190100-74 Adaptor for Sartorius 16A07 (100ml) plastic funnel 190100-75 Adaptor for Pall 4870 (100ml), 4871 (250ml) filter funnel 190100-76 Hose barb adaptor (for Ø4-8mm tubing) 167103-61 Stainless steel funnel 100ml 167103-63 Stainless steel funnel 300ml 167103-65 Stainless steel funnel 500ml 167400-11 Rocker 400 Vacuum pump, AC110V/60Hz 167400-22 Rocker 400 Vacuum pump, AC220V/50Hz 167200-48 4000ml PP waste bottle with drain 167100-52 GN-6 membrane filter, grid, sterilized, 0.45um. 177100-00 Dragon 100 torch burner 167200-38 Silicon tube, 1 m.

Rocker Scientific Co., Ltd. / www.rocker.com.tw / +886-2-26033311 / EnV2016.8