Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM Technical Data Sheet

Similar documents
Ice*Meister Model 9732-PLASTIC*

Marley Collection Basin Heater Circuit

An overview of unmanned aerial vehicle hazards due to ice-induced tailplane stall, its causes, effects and detection before landing.

/ Marley Collection Basin Heater / User Manual

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

GAS MONITOR Model Model

Basic Vehicle Fire Protection Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Fiber Optic Cable Fence Disturbance Sensor

F1202 TRACE HEATING. Road & Ramp

FR-A180 FR-A360. Occupancy detector. Use

ADDITIONAL INFORMATION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Model OEM-2 INSTRUCTIONS FOR USE

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Instructional & Operating Manual

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Dual Column Dehydrating Breather Manual

NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

NT DUAL CHANNEL DISPLAY. User Guide

D-TEK Select. Refrigerant Leak Detector

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

DRC12FR DRC12FR347. Dynalite. Install Guide

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Steam Humidification Light Commercial Applications. Better technology means better business.

Model GIT 4 Gutter Snow and Ice Melting Control

CMT MANUAL 6. NMC SENSORS

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

GUIDE BOOK FROSTIE FROST FIGHTING CONTROLLER

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Macurco HD-11 Hydrogen Gas Detector

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

RK-05 Combustible Gas Transmitter Operator s Manual

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Owner s Manual Compact Fluorescent Lunar Aqualight

onlinecomponents.com

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

PANTHER. Condensate removal pump Installation and operating guide

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

H-10PM. Refrigerant Leak Detector

THERMAL MANAGEMENT SOLUTIONS

Light Level Detector, Surface Mount 5754PE. Installation Instructions

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

ACS-30-EU-EMDR- 10-MOD

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

AlarmLine Linear Heat Detector

Installation Instructions

FOOD WARMING/MERCHANDISING CABINET MODEL 737/737HH

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Mark 25 Ultrapure Water Conductivity Analyzer

RMS/RPX Reader. User Manual

Sitron s CF Line of Flow Switch Monitors

Model 3300 Technical Support and Installation Manual

Remote Storage Safety 3 Alarm Installation Guide

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

INTRODUCTION / TABLE OF CONTENTS

SEC Signature Process Gas Analyzer

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Important Notes: Please read carefully before installing your refrigerator.

RX1200 ROOF AND GUTTER DE-ICING CONTROLLER INSTALLATION AND OPERATION MANUAL

Dual Laser InfraRed (IR) Thermometer

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

RK CO 2 Transmitter Operator s Manual

Tru Pointe Ultra Ultrasonic Leak Detector

KILOVAC K1K High-Voltage Contactor

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

DETECT-A-FIRE Heat Detectors

Dry Contact Probe DCP (#30008)

Sintrol Snifter A1+ Manual. Version 1.2.2

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

For use with models: BP , BP , BP

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

DEVELOPMENT OF AN ELECTROTHERMAL ICE PROTECTION SYSTEM FOR WIND TURBINE APPLICATIONS. IWAIS Conference. Presenter: Dave O HernO. Goodrich Corporation

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

Model 6021 Electrically Heated Rain and Snow Gauge

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

THERMAL MANAGEMENT SOLUTIONS

SC Installation, Operation & Application Guide

Powerley Thermostat. Installation & Operation Guide

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

IN2 Lighting Control Devices

MicrOTDR. Optical Fault Locator. User Manual

Transcription:

1 Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM Technical Data Sheet Figure 1 Ice*Meister Model 9734-SYSTEM optical ice sensing detector system is easy to install and completely self-contained in one compact, lightweight unit. Senses H2O in its solid and liquid phases. Indicates ice alert with output relay contacts and blue indictor LED. 1

2 GENERAL DESCRIPTION Ice*Meister Model 9734-SYSTEM industrial ice detecting sensor system is an optical go/no-go ice sensor for general purpose industrial applications, such as wind power turbines, HVAC cooling towers, radio and TV broadcast towers, oil and gas rigs, vehicular bridges, overpasses, etc. It is completely selfcontained. No external components are required. Model 9734 consumes little energy; powered by a 5W solar panel, is suitable for use in remote locations. 9734 monitors the optical characteristics of whatever substance is on the probe. If AIR is on the probe, output indicates NO ICE. If H2O is on the probe, output indicates ICE ALERT. Liquid water simply runs off by gravity, but ICE adheres to the optical surfaces. There are no moving parts. Unit detects H2O in its solid and liquid phases, including rime ice, snow, frost, clear ice, standing water. Gravity removes ice melt from the optics. This sensor has no specified accuracy, and is not intended to be used as an analog measuring instrument of any kind. Model 9734 contains a small embedded circuit board, an optical probe, a plastic housing, and a lightweight blue cable that connects to its host system. Standard cable length is 6 feet, but the cable length can be greatly extended by if necessary. Model 9734 indicates the presence of ice. An optional protective cage is available to help guard against falling debris. Various mounting options are available for diverse applications. Figure 2 a, b -- Ice*Meister Model 9734-SYSTEM senses frost (left) and ice (right). 2

3 SPECIFICATIONS SENSITIVITY TO ICE ACCUMULATION: Better than 0.01 inch of rime or clear ice. ORIENTATION: Unit operates with the top of its housing facing UP. OPERATING / STORAGE TEMPERATURE: -40 deg C to + 50 deg C. Not warranted to detect ice above 0 deg C. ELECTRICAL INPUT: Any clean DC voltage from 6 VDC to 30 VDC Current draw at 24 VDC < 100 ma max red wire = + 24 volts DC black wire = earth ground, - 24 volts DC ELECTRICAL OUTPUT: 1 set of single pole, single throw, normally open relay contacts, Rated at 1 Amp, 50 volts non-inductive (see attached relay data sheet) Close when frost is present, Open when frost is absent. Green and white wires = relay contacts VISUAL OUTPUT: Probe turns BLUE to indicate ice is present and relay contacts are closed. CONNECTING CABLE (figure 4): 0.1 inch diam lightweight four-conductor shielded cable, stripped and tinned Red, black wires: 24 VDC in Green, white wires: Relay contacts out Length: 6 feet DIMENSIONS: Sensor head: Height: 2½ inches Width: 1¼ inches Depth: 1 inch Probe extension from housing: 1 inch Mounting plate: Length: 11 inches Width: 4 inches Thickness: ½ inch WEIGHT: 4 ounces exclusive of mounting hardware 3

4 CONNECTING CABLE Figure 3 -- Lightweight blue cable features rugged Teflon outer jacket, internal aluminum shield with ground wire, and four stranded, tinned copper wires. Figure 4 -- Specifications for connecting cable. 4

5 TESTING STANDARD TEST CONDITIONS for testing in a laboratory ambient temperature energize unit, soak at ambient temp ½ hour 25 deg C (normal office temp) fluorescent illumination (from ceiling) 500 lux (normal office lighting) ambient lighting white LED illumination no limit sunlight 0.0 incandescent lamp 0.0 mechanical mounting plate orientation sensor air-gap orientation horizontal up testing I desktop test with 9-volt battery and foam dunnage chip. convenient out-of-the-box test testing II desktop CLEAR ICE test with transparent tumbler of tap water. differentiates clear ice from frost testing III field test with commercial component cooler cold spray. simulates actual frost ice 5

6 TESTING I (out-of-the-box) Convenient, simple, first-thing-out-of-the-box desktop or field test with supplied 9-volt battery and foam dunnage chip: Connect 9734 s red wire to the 9-volt battery s positive ( + ) terminal, and the black wire to the battery s negative ( ) terminal. Insert foam dunnage into 9734 s air gap. Observe blue indicator LED glows, indicating the foam has simulated FROST threshold. Listen for relay activation *click* inside the solid 9734 housing. Using a suitable continuity checker, confirm output relay contacts close between white and green wires. Figure 5 a, b -- Desktop test with supplied 9-volt battery and opaque charcoal test foam. Figure 6-- Opaque charcoal test foam is readily available from office supply stores. A 9-volt battery and foam sample are supplied with 9734 order. 6

7 TESTING II (water CLEAR ICE test) Simple, CLEAR ICE test with a clear glass tumbler of clean tap water. With 9734 still connected to the battery or a suitable DC power supply, submerge the probe into a tumbler of clean tap water. The tumbler must be transparent glass, as shown below. Observe the blue LED illuminates, the relay *clicks* closed, and continuity tester confirms the relay contacts are closed, as Testing I, above. Figure 7 a, b -- CLEAR ICE test with 9-volt battery and clear glass tumbler of clean tap water. 7

8 TESTING III (field test) 9734 can be tested with Radio Shack brand component cooler p/n 64-4321 cold spray. Be certain to use only TETRAFLUOROETHANE COMPONENT COOLER to avoid damaging the acrylic optical components in the air gap. Figure 8 a, b -- Commercial component cooler spray freezes moisture out of the ambient air, simulates detectable ice. Figure 9 a, b Test 9734 for frost and rime ice with sprayed stream of Radio Shack tetrafluoroethane component cooler p/n 64-4321; leaves no residue. Cold spray freezes moisture out of the ambient air, creates detectable surface frost. 8

9 DISCLAIMERS 1. Specifications and other contents are subject to change at any time without notice. 2. This document is not contractual. Nothing in it constitutes or implies a warranty or guaranty of any kind, explicit or implicit. Warranty information is given only in separate "warranty" statement. 3. Plastic optical probe is made of Polymethylmethacrylate, also called PMMA, acrylic, or Plexiglas. It should be protected from mechanical abuse, abrasion and harsh chemicals. Damage to the probe voids the warranty. 4. No warranty is given as to the suitability of this product for any particular application. 5. Initial thermal shocking of the sensor may cause condensation to form on the optics and register as "frost". 6. This unit is not a measuring instrument, and provides no specific calibration. 7. When installed on a met tower, probe should face NORTH to minimize sunlight contamination. 8 Allow unit to soak at ambient temperature before evaluating. Test under fluorescent or energy-saving LED lighting; see STANDARD CONDITIONS. NOTES 1. Ice*Meister is a trademark of New Avionics Corporation. 2. Ice*Meister is protected under one or both US Patents # ooooooo and # oooooooo. Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM New Avionics Corporation 2501 East Commercial Blvd Fort Lauderdale FL 33308 USA Info@newavionics.com 954-776-1900 9