Self-learning Room Temperature Controller

Similar documents
Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

REA22 Room Temperature Controller

Self-learning Room Temperature Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Use. Functions. Key function. Other functions

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

QAW70. Room Unit. Building Technologies. for use with heating controllers

Room Unit. Building Technologies SYNERGYR

Room thermostat with Auto Timer, Option External Input

Room thermostats with LCD for wall mounting

RVL470. Heating Controller. Use. Functions. Series B

Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, Option External Input

Wireless room thermostat with LCD

Flush-mounted room thermostats

Room Temperature Controller with LCD

Room thermostat with independent DHW control

Room Temperature Controller

Immersion Temperature Controller

Room thermostat with 24-hour time switch and large LCD

Room Temperature Controller

RVP310. Heating Controller. Building Technologies HVAC Products

RAA30 RAA30.16/GR RAA30.26/GR. Room Thermostat. Adjustable room thermostat for heating only or cooling only systems

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Room Temperature Controllers

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Digital Room Thermostat for Heating Applications with 7-Day Time Program

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

G a

for relative humidity and temperature

Room Temperature Controller

Semi flush-mount room thermostat

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

PRELIMINARY EDITION

Application guide RDG160 Remote control

Semi flush-mount room thermostats

Room Temperature Sensors

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

District Heating Controller

Room thermostats with LCD RDD100..

Flush-mounted room thermostat

for relative humidity and temperature

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Touch Screen Flush-mount Room Thermostats with KNX Communications

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Preliminary Release. Room Temperature

Semi flush-mount communicating room thermostats

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Landis & Gyr RAV 91 Operating Instructions

Room thermostat with Auto Timer, independent DHW

Frost Protection Thermostat

for relative humidity and temperature with calibration certificates

Use. For 2-pipe fan coils

UV Flame Supervision System

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Operating Instructions

Room Air Quality Sensors

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room thermostat with Auto Timer, Option External Input

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Wall-mounted room thermostat with LCD

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Room air quality sensors

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

RVL480. Heating Controller

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Room Temperature Sensors

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

RVL481. Heating Controller. including d.h.w. heating

RVL479. Heating Controller. for use with a partner unit

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

Saving energy while ensuring an enhanced room climate

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Control solutions Biofloor

Storage tank size Rated volume [l] Actual volume [l]

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

ECL Comfort V a.c. and 24 V a.c.

Thermostatic Actuators

LC2200 Level Controller Installation and Maintenance Instructions

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

Room controllers with manual forced ventilation function

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

LAE10 LFE10. Use. Series 02

TIREE FAN COIL CONTROLLER - T6580

Duct Temperature Sensors

Duct Air Quality Sensors

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Boiler Sequence Controller

Transcription:

2 226 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch and possibility of remote control RAV12 Mains powered room temperature controller featuring straightforward operation. Self-learning two-position controller providing PID control (patented). Freely selectable switching times. Use Functions ype summary Ordering Delivery Room temperature control in: Single-family and holiday houses Apartments and office spaces Individual rooms and consulting rooms Commercially used spaces For the control of the following pieces of equipment: Solenoid valves of instantaneous water heaters Solenoid valves of atmospheric gas burners Forced draught gas and oil burners Circulating pumps in heating systems Electric direct heating Fans of electric storage heaters Zone valves (normally closed) PID control Self-learning or selectable switching cycle Freely adjustable 24-hour mode Freely adjustable weekly mode with weekly time switch Frost protection function Minimum limitation of set point Room temperature controller, AC 230 V mains powered without time switch (not soled in this form) Room temperature controller, AC 230 V mains powered with analogue 24-hour time switch Room temperature controller, AC 230 V mains powered with analogue weekly time switch Analogue 24-hour time switch Analogue weekly time switch When ordering, please give type reference according to "ype summary". he unit is supplied with all necessary features. RAV12 RAV12.1 RAV12.7 AUZ3.1 AUZ3.7 Siemens Building echnologies CE1N2226E / 01.02.2000 Landis & Staefa Division 1/8

8 Mechanical design Plastic casing with analogue 24-hour or weekly time switch, easily accessible operating elements and removable cover. he base plate can be fitted to all commercially available recessed conduit boxes or directly on the wall and can then be wired before attaching the controller to it. he casing accommodates the electronics with the DIP switch. he potential-free changeover contact and the connection terminals are located on the base plate. Display and operating elements 6 16 1 14 13 12 11 10 1 20 2 30 3 1 20 18 19 21 17 10 9 7 6 AUO C 2 22 23 24 1 2 3 4 10 1 20 2 4 30 C 2226Z02 Analogue time switch appets tilted outward for normal temperature appets tilted inward for economy temperature Operating mode selector Heating periods according to tappet settings on time switch Continuous normal temperature Continuous economy temperature Standby with frost protection Setting knob for normal temperature Setting knob for economy temperature LED Signalisation of override by remote control or activation of relays by switched on heating system. Position for time switch Operating modes Heating periods according to tappet settings on time switch Continuous normal temperature Continuous economy temperature Standby with frost protection Set points Factory settings Setting range 20 C 30 C 1 C 30 C LED When the LED lights up, the following is signalised: With a connected remote control the unit is overridden from the outside (e.g. by a telephone switch). When no remote control is connected, the relays is activated and the heating is switched on. CE1N2226E / 01.02.2000 Siemens Building echnologies 2/8 Landis & Staefa Division

Calibration of detector emp. Offset DIP-Switch Reset 2224Z17 If the measured room temperature does not agree with the temperature set on the knob, the temperature detector can be recalibrated. his can be done by adjusting a potentiometer that is located on the rear of the unit. First, the unit must be removed from the socket. 2224Z04 he possible settings on the potentiometer are: 20 1 2 10 30 ( C) ( C) Pos. 22.00 20.00 8 21.7 20.00 7 21.0 20.00 6 21.2 20.00 21.00 20.00 4 20.7 20.00 3 20.0 20.00 2 20.2 20.00 1 20.00 20.00 0 <= Factory setting 19.7 20.00 F 19.0 20.00 E 19.2 20.00 D 19.00 20.00 C 18.7 20.00 B 18.0 20.00 A 18.2 20.00 9 After the corrections are made, the new setting must be confirmed by pressing the reset button. Otherwise the previous settings are still active! After the reset the controller can be remounted to the socket. Remote operation With the help of a suitable remote operation unit, the controller can be switched to the economy temperature set for operating mode. Changeover takes place through the making of a potential-free contact connected to terminals 1 and 2. he LED indicates this by being light. After the contact opens, the selected operating mode becomes active again. Operation according to the settings made on the controller 1 Continuous economy temperature 1 2 2226Z04 2 2226Z0 Suitable remote operation units are e.g.: elephone modem manual switch window switch presence detector central unit Siemens Building echnologies CE1N2226E / 01.02.2000 Landis & Staefa Division 3/8

echnical features DIP-Switch Self learning PID 12 PID 6 2-Pt 1 2 3 4 2224Z01 Control Self-learning mode he RAV12 is a two-position controller providing PID control. he room temperature is controlled through the cyclic switching of a regulating unit.. he controller is supplied with an active self-learning mode, which enables it to automatically adapt to the controlled system (type of building construction, type of radiators, size of rooms, etc.). After a certain learning period, the controller optimises its parameters and then operates in the mode it has learned. In exceptional cases, where the self-learning mode may not be adequate, it is possible to choose between PID 12, PID 6 or 2-Pt mode: PID 12 mode PID 6 mode 2-Pt mode Switching cycle of 12 min for normal or slow controlled systems (e.g. massive building structures, large spaces, cast-iron radiators, oil burners). Switching cycle of 6 min for fast controlled systems (e.g. light building structures, small spaces, plate radiators or convectors, gas burners). Pure two-position control with a switching differential of 0. C (±0.2 C) for very difficult controlled systems with considerable outside temperature variations. Setting knobs Standard 30 C 30 C Version 1 * 20 C 1 C Version 2 * 18 22 C 13 17 C Version 3 * 1 2 C 10 20 C * upon request Analogue time switches he unit has an opening for fitting a plug-in type switch. If desired, the time switch fitted can be replaced by another. he electrical connections to the controller are established via a terminal strip so that no wiring is required. he time switches can only be mounted in one position. he analogue time switches are equipped with a quartz clock he switching dial is equipped with tappets that can be tilted. he heating periods are entered by tilting the tappets within the required period of time: appets tilted outward: appets tilted inward: 24-hour time switch Normal temperature Economy temperature Weekly time switch he 24-hour time switch has a 24-hour switching dial. It carries 96 tappets, which means four tappets per hour, giving a resolution of 1 minutes. he shortest possible heating period also is 1 minutes. he weekly time switch has a 7-day switching dial. It carries 84 pairs of tappets, which means 12 pairs of tappets or 24 individual tappets per day. he resolution is thus one hour. However, since - for mechanical reasons - at least two tappets need to be tilted together to set one heating period, the shortest possible heating period is two hours. CE1N2226E / 01.02.2000 Siemens Building echnologies 4/8 Landis & Staefa Division

Notes Engineering he room temperature controller should be fitted in the main living room. he place of installation should be chosen so that the sensor can capture the room temperature as accurately as possible, without being affected by direct solar radiation or other heating or cooling sources. Mounting height is approx. 1. m above the floor. he unit can be fitted to most commercially available recessed conduit boxes or directly on the wall. Fitting and installation Commissioning When installing the room temperature controller, the base plate must first be fitted and wired. hen, the unit is engaged at the top, swung downward and secured with a screw. For more detailed information, please refer to the installation instructions supplied with the controller. For the electrical installation, the local safety regulations and standards must be complied with. he control characteristics can be changed with the help of the DIP switches located at the rear of the unit. If the reference room is equipped with thermostatic radiator valves, they must be set to their fully open position. If the measured room temperature does not agree with the set room temperature on the setting knob, the detector should be recalibrated (please refer to "Calibration of detector"). echnical Data Operating voltage AC 230 V - conformity to EEC directive 89/336/EEC low voltage directive 73/23/EEC Switching capacity of relays Voltage AC 24 20 V Current 8 (3.) A Measuring element NC 68 kω at 2 C Measuring range 0 40 C ime constant 2 min max. Set point setting range Normal temperature 3 29 C Economy temperature 3 29 C Resolution of analogue time switches 24-hour time switch 1 min Weekly time switch 60 min Set point for frost protection C Insulation class to EN 60730-1 II Degree of protection to EN 6029 IP 30 Electromagnetic compatibility Immunity EN 0082-2 Emissions EN 0081-1 Perm. ambient temperature Operation 3 3 C Storage -2 +60 C Perm. ambient humidity to DIN 40040 G Weight 0.2 kg Colour White RAL 9003 Siemens Building echnologies CE1N2226E / 01.02.2000 Landis & Staefa Division /8

Connection diagram L Lx AC 230 V L N 1 2 L2 Lx L1 N1 AC 24...20 V S1 N Nx Y1 M1 2226A01 L Live, AC 230 V Nx Neutral AC 24...20 V Lx Live, AC 24...20 V N1 RAV12.. controller L1 N.O. contact, AC 24 20 V / 8 (3.) A S1 1 Remote operating unit (potential-free) Signal "remote operation" L2 N.C. contact AC 24...20 V 2 Signal "remote operation" M1 Circulating pump Y1 Regulating unit N Neutral AC 230 V Application examples N1 F1 F2 N1 F2 F1 Y2 M1 Y2 M1 2222S01 2222S02 Instantaneous water heater) Atmospheric gas burner N1 Y1 M1 2222S03 Circulating pump with pre-control by manual mixing valve F1 hermal reset limit thermostat N1 RAV12.. room temperature controller F2 Manual reset safety limit thermostat Y1 Manually operated three-port valve M1 Circulating pump Y2 Solenoid valve CE1N2226E / 01.02.2000 Siemens Building echnologies 6/8 Landis & Staefa Division

Dimensions 138 2226M02 37 2226M01 104 Siemens Building echnologies CE1N2226E / 01.02.2000 Landis & Staefa Division 7/8

1999 Siemens Building echnologies Ltd. Subject to change CE1N2226E / 01.02.2000 Siemens Building echnologies 8/8 Landis & Staefa Division