Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

Similar documents
VERSO Air Handling Units

VERSO Air Handling Units

DOMEKT. Residential ventilation units

DOMEKT. Heat Recovery Air Handling Units

Heat Recovery Air Handling Units

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

DOMEKT. Residential ventilation air handling units

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

Energy efficient ventilation equipment

KOMPAKT. Air Handling Units

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

Energy efficient ventilation equipment

KOMFORT EC DB Suspended heat recovery air handling units

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

AIR HANDLING UNITS ver B

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Series VENTS VUT R WH ЕС

We simplify construction

VERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h

Ionisation single-tube smoke detector for duct mounting

TopMaster Air Handling unit. Technical data

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

DOMEKT Residential ventilation units

AHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe

RoofVent Design Handbook

RIS V EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. AHU med varmegenvinding AIR HANDLING UNITS

TopVent Design Handbook

17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

We simplify construction

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

EC L2. and humidity sensors. All units are supplied tested and ready to install.

UNITES TERMINALES ET MINI CTA FIDJI

VERSO. Commercial ventilation units 01/03/ Tél

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Fan Coil Unit CULTRA

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Air handling units Compair. Technical Catalogue

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

OXeN. Ductless ventilation with heat recovery.

Heat recovery unit RDKS

Semi flush-mount room thermostat

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Heat Recovery Units. Heat Recovery 1

Gas heaters and convectors ROBUR

We simplify construction

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

Flush-mounted room thermostat

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Lo-Carbon Sentinel Kinetic Horizontal

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

C5.1. VERSO Pro S / R / P / RHP / PCF. EN Installation and Maintenance Service Manual

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Technical Information HXV - HRV Ventilation

COMPACT Air & Heat. Contents

Ceiling swirl diffusers

Bevent Rasch. FIDm. - Fire /11/2018

Transcription:

Domekt Units PRICE GUIDE 2018

price-list 2018 PRICE-LIST air handling units are designed for the ventilation of residential premise. series offers the standardized range of air handling units with heat recovery by rotary or counter-flow plate heat exchanger, or just airs supply units. Units' air flow performance ranges from 50 m 3 /h to 1000 m 3 /h. A compact and universal air handling units' design helps to integrate them in a kitchen furniture. It is also possible to hang the units on the wall, ceiling, or to put it on the floor. All units are based on the PLUG & PLAY principle: each unit has the integrated control system and is delivered with a complete automatic control installed and prewired inside the unit. A modern control panel can be supplied with each unit. Due to the availability of clever design and functions the units offer a great opportunity to keep running costs low. They are safe, reliable and durable in operation. The filtered air is supplied clean and fresh to the premises, which is extremely advisable for allergic people. Ordering example Inspection side is determined by the supply air direction, looking at the unit from the user's side. Page 2 of 16

SERIES AIR HANDLING UNITS Unit type Units with a rotary heat exchanger * Units with control system C4 Unit marking PRICE for unit with control system C6 (panel is not included) Domekt-R-200-V-E* 1724 Domekt-R-200-V-W/DH* 1869 Domekt-R-250-F 1754 Domekt-R-300-V 1896 Domekt-R-400-V 2069 Domekt-R-400-H 2465 Domekt-R-400-F 2169 Domekt-R-450-V 2300 Domekt-R-500-H 2856 Domekt-R-500-V 2982 Domekt-R-600-H 2444 Domekt-R-700-V 3377 Domekt-R-700-H 3246 Domekt-R-700-F 3716 Unit type Units with a counterflow plate heat exchanger Unit marking PRICE for unit with control system C6 (panel is not included) Domekt-CF-250-V* 1396 Domekt-CF-250-F 1571 Domekt-CF-400-V 2330 Domekt-CF-500-F 2461 Domekt-CF-700-V 2976 Domekt-CF-700-H 2976 Domekt-CF-700-F 3206 * Unit with control system C4, without any heater inside. Unit type Supply air units Unit marking PRICE for unit with control system C5 and panel C5.1 Domekt-S-650-F-E/3 1768 Domekt-S-650-F-E/6 1815 Domekt-S-800-F-E/6 1881 Domekt-S-800-F-E/9 1976 Domekt-S-800-F-W 1928 Domekt-S-1000-F-E/9 2164 Domekt-S-1000-F-E/15 2248 Domekt-S-1000-F-W 2189 Page 3 of 16

Units available up to July 2018 Unit type Units with a plate heat exchanger Unit marking PRICE for unit with control system C4 (panel is not included) Domekt-PP-300-V-E 1926 Domekt-PP-300-V-W/DH 2071 Domekt-PP-450-V-E 2356 Domekt-PP-450-V-W/DH 2482 Notes: Units with control system C6 are equipped with electric heater inside. Additionally duct mounted water heaters DH can be ordered and controlled (user must change settings to activate water heater function). Units' codes marked with W/DH are without any heater inside. Duct mounted water heater DH (see page 4) must be ordered additionally. Units' prices are indicated with M5 class filters. Panels for units with C6 and C4 control systems must be ordered additionally. Panel C6.1 Code 745201581 PRICE 234 Panel C6.2 745201583 123 Panel C4.1 745201515 234 Page 4 of 16

ACCESSORIES FOR UNITS HOT WATER DUCT MOUNTED AIR HEATER DH Type Dimensions, mm Tubes Code PRICE D B H L, L connection DH-125 125 335 295 152 270 1/2 712200054 194 DH-160 160 335 295 152 270 1/2 712200044 195 DH-200 200 360 320 152 270 1/2 712200043 208 DH-250 250 420 380 152 270 1/2 712200042 240 DH-315 315 470 510 152 270 1/2 712200041 292 DH-315M 315 480 520 132 250 1/2 712200051 356 DH-355 355 600 510 152 310 1/2 712200053 362 DUCT MOUNTED AIR HEATER-COOLER DHCW Type Dimensions, mm Code PRICE D B H L, L Tubes connection DHCW-125 125 335 335 164 280 1/2 712255603 300 DHCW-160 160 335 335 164 285 1/2 712200045 328 DHCW-200 200 365 365 164 285 1/2 712200049 351 DHCW-250 250 425 425 164 285 1/2 712200046 405 DHCW-315 315 560 515 164 285 1/2 712200047 478 DHCW-355 355 605 605 164 325 1/2 712200080 506 Unit size DH type DHCW type Domekt-R-200-V DH-125 DHCW-125 Domekt-R-250-F DH-160 DHCW-160 Domekt-R-300-V DH-160 DHCW-160 Domekt-R-400-V DH-160 DHCW-160 Domekt-R-400-H DH-160 DHCW-160 Domekt-R-400-F DH-200 DHCW-200 Domekt-R-450-V DH-160 DHCW-160 Domekt-R-500-H DH-250 DHCW-250 Domekt-R-500-V DH-250 DHCW-250 Domekt-R-600-H DH-200 DHCW-200 Domekt-R-700-H DH-250 DHCW-250 Domekt-R-700-V DH-250 DHCW-250 Domekt-R-700-F DH-250 DHCW-250 Domekt-CF-250-F DH-160 DHCW-160 Domekt-CF-400-V DH-160 DHCW-160 Domekt-CF-500-F DH-200 DHCW-200 Domekt-CF-700-V DH-200 DHCW-200 Domekt-CF-700-H DH-250 DHCW-250 Domekt-CF-700-F DH-250 DHCW-250 Domekt-PP-300-V DH-125 DHCW-125 Domekt-PP-450-V DH-125 DHCW-125 Page 5 of 16

ELECTRIC CIRCULAR DUCT AIR HEATER EHC-SI/FC (-30... 0 C) Heater with an integrated control (internal set point), with flow and pressure control. Type Heating power, kw Code PRICE EHC-125-1,0-1f SI/FC 1.0 762100476 199 EHC-160-1,0-1f SI/FC 1.0 762100477 202 EHC-160-1,5-1f SI/FC 1.5 762100478 211 EHC-160-2,0-1f SI/FC 2.0 762100479 215 EHC-200-1,0-1f SI/FC 1.0 762100480 204 EHC-200-1,5-1f SI/FC 1.5 762100481 216 EHC-200-2,0-1f SI/FC 2.0 762100482 219 EHC-250-1,0-1f SI/FC 1.0 762100483 208 EHC-250-1,5-1f SI/FC 1.5 762100484 217 EHC-250-2,0-1f SI/FC 2.0 762100485 220 EHC-250-3,0-1f SI/FC 3.0 762100486 237 EHC-315-2,0-1f SI/FC 2.0 762100487 229 EHC-315-3,0-1f SI/FC 3.0 762100488 245 Notes: Voltage 1~230 V/50Hz. Temperature working range for the indicated codes is from -30 C to -0 C. Heaters codes with temperature range from 0 C to +30 C must be asked upon request. Page 6 of 16

PIPEWORK PACKAGE PPU (fully assembled) 1. Stop valve 2. Return valve 3. Throttling valve 4. Control valve 5. Circulation pump 6. Manometer/ Thermometer 7. Actuator These PPU codes are indicated for right side connections (R). There is also a possibility to order left side (L) PPU. PPU type Code PRICE Air handling unit Heater PPU type PPU-HW-3R-15-0,4-W1 744110065 592 Domekt-R-200-V DH-125 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-15-0,63-W1 744110068 592 Domekt-R-250-F DH-160 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-15-1-W2 744110071 605 Domekt-R-300-V DH-160 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-15-1,6-W2 744110073 622 Domekt-R-400-V DH-160 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-15-2,5-W2 744110075 638 Domekt-R-400-H DH-160 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-20-4-W2 744110129 700 Domekt-R-400-F DH-200 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-20-4-W3 744110077 850 Domekt-R-450-V DH-160 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-20-4-W4 744110078 1189 Domekt-R-500-H DH-250 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-25-6,3-W2 744110130 735 Domekt-R-500-V DH-250 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-25-6,3-W3 744110081 888 Domekt-R-600-H DH-200 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-25-6,3-W4 744110082 1224 Domekt-R-700-V DH-250 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-25-10-W3 744110131 1224 Domekt-R-700-H DH-250 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-25-10-W5 744110084 1288 Domekt-R-700-F DH-250 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-32-16-W3 744110132 1317 Domekt-CF-250-F DH-160 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-32-16-W5 744110086 1383 Domekt-CF-400-V DH-160 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-32-16-W6 744110087 1749 Domekt-CF-500-F DH-200 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-40-25-W3 744110133 1432 Domekt-CF-700-V DH-200 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-40-25-W5 744110089 1499 Domekt-CF-700-H DH-250 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-40-25-W7 744110090 1854 Domekt-CF-700-F DH-250 PPU-HW-3R-15-0,63-W1 PPU-HW-3R-40-25-W8 744110091 2598 Domekt-S-800-F integrated PPU-HW-3R-15-2,5-W2 PPU-HW-3R-50-40-W7 744110092 2071 Domekt-S-1000-F integrated PPU-HW-3R-20-4-W2 PPU-HW-3R-50-40-W8 744110093 2822 Domekt-PP-300-V DH-125 PPU-HW-3R-15-0,4-W1 PPU-HW-3R-50-40-W9 744110094 3211 Domekt-PP-450-V DH-125 PPU-HW-3R-15-0,4-W1 Note: PPU selection program can be found on www.komfovent.com TWO WAY WATER CONTROL VALVE AND MODULATING ACTUATOR Valve type k vs, m 3 /h Code PRICE Actuator type Code PRICE VVP47.10-0.25 0.25 744600034 33 SSP61 744600235 119 VVP47.10-0.4 0.40 744600365 33 SSP61 744600235 119 VVP47.10-0.63 0.63 744600303 33 SSP61 744600235 119 VVP47.10-1.0 1.0 744600366 33 SSP61 744600235 119 VVP47.10-1.6 1.6 744600367 33 SSP61 744600235 119 VVP47.15-2.5 2.5 744600368 38 SSP61 744600235 119 VVP47.20-4.0 4.0 744600369 47 SSP61 744600235 119 VVP45.25-6.3 6.3 744600370 98 SSB61 744600240 119 VVP45.25-10.0 10.0 744600835 122 SSC61 744600245 177 Page 7 of 16

AIR DAMPERS WITH ACTUATORS Unit size Air damper + actuator with spring return Code PRICE Air damper + actuator without spring return Code PRICE Domekt-R-200-V AGUJ-M-125 + LF230 707055732 193 AGUJ-M-125 + LM230 707046715 96 Domekt-R-250-F Domekt-R-300-V Domekt-R-400-V/H Domekt-R-450-V Domekt-R-400-F Domekt-R-600-H Domekt-R-500-H/V Domekt-R-700-H/V/F AGUJ-M-160 + LF230 000035707 194 AGUJ-M-160 + LM230 707034983 97 AGUJ-M-200 + LF230 000022919 197 AGUJ-M-200 + LM230 707034987 100 AGUJ-M-250 + LF230 707029682 198 AGUJ-M-250 + LM230 707025128 101 Domekt-CF-250-V AGUJ-M-125 + LF230 707055732 193 AGUJ-M-125 + LM230 707046715 96 Domekt-CF-250-F Domekt-CF-400-V Domekt-CF-500-F Domekt-CF-700-V AGUJ-M-160 + LF230 000035707 194 AGUJ-M-160 + LM230 707034983 97 AGUJ-M-200 + LF230 000022919 197 AGUJ-M-200 + LM230 707034987 100 Domekt-CF-700-H/F AGUJ-M-250 + LF230 707029682 198 AGUJ-M-250 + LM230 707025128 101 Domekt-S-650-F AGUJ-M-160 + LF24 707018964 179 AGUJ-M-160 + LM24 707022764 97 Domekt-S-800-F AGUJ-M-200 + LF24 707000027 182 AGUJ-M-200 + LM24 707055006 100 Domekt-S-1000-F AGUJ-M-250 + LF24 000031047 183 AGUJ-M-250 + LM24 707061244 101 Domekt-PP-300-V Domekt-PP-450-V AGUJ-M-125 + LF230 707055732 193 AGUJ-M-125 + LM230 707046715 96 Control system Actuator ON/OFF Komfovent C4, C6 LF230 LM230 Komfovent C5 LF24 LM24 Notes: LF damper actuator is with spring-return. LM damper actuator is without spring-return. Type Code PRICE Air damper control cable connection 744900366 16 Note: For Domekt units with electric heaters and C4 automatic control. Page 8 of 16

DCW WATER AND DCF DIRECT EVAPORATION AIR COOLERS Air cooler is mounted next to the unit. Casing of the cooler section is made of the galvanized steel sheets with internal mineral wool insulation. Cooler section is assembled with a drop separator and a drain tray. Cooler control function is provided in the automatic control system of the unit. Refrigerant type - R410A, water 7/12. Air temperature in/out - 30/18 C. For units with C5 or C6 controllers. Type Supply air volume, m 3 /h Capacity, kw Air pressure drop, Pa* Fluid pressure loss, kpa BxHxL, mm B1xH1, mm Tubes connections Weight, kg Code PRICE DCF-0,4-3 400 2.7 16 0.3 600x550x390 300x400 1/2 / 22 mm 40 DCW-0,4-3 400 2.7 34 15.8 505x550x390 300x400 1/2 33 DCF-0,5-3 500 3.4 19 0.4 600x550x390 400x300 1/2 / 22 mm 40 DCW-0,5-3 500 3.4 30 29.5 600x550x390 400x300 1/2 35 DCF-0,7-5 700 4.7 22 0.4 705x610x390 500x400 1/2 / 22 mm 49 DCW-0,7-5 700 4.7 29 11.2 705x610x390 500x400 1/2 42 DCF-0,9-6 900 6.1 29 0.7 705x610x390 500x400 1/2 / 22 mm 49 DCW-0,9-6 900 6.0 36 3.7 705x610x390 500x400 3/4 45 Note: * With drop eliminator. 765300002 (R) 765300032 (L) 765300001 (R) 765300031 (L) 765300052 (R) 765300057 (L) 765300063 (R) 765300058 (L) 765300004(R) 765300034 (L) 765300003 (R) 765300033 (L) 765300006(R) 765300036 (L) 765300005 (R) 765300035 (L) 1014 857 1027 875 1039 892 1039 892 UNIVERSAL OUTDOOR UNITS MOU Outdoor units MOU are intended for direct evaporation coolers. Refrigerant type - R410A. Type Cooling capacity, kw Heating capacity, kw Maximal operating current, A Supply voltage, V Sound level, db (A) Diameter of tubes (fluid/gas), mm Maximal length of tubes, m Code PRICE Inverter MOU-18HFN6+KA8243 5,3(0,79-6,2) 5,7(0,88-7,0) 10 230 56.5 Inverter MOU-24HFN6+KA8243 7,0(1,2-8,2) 7,0(1,2-8,7) 14 230 60.5 Inverter MOU-36HFN6+KA8243 10,6(2,9-12,0) 11,1(2,6-13,2) 10 400 62 Inverter MOU-48HFN6+KA8243 13,8(4,0-16,1) 15,5(4,2-17,6) 13 400 65 Inverter MOU-55HFN6+KA8243 16,1(5,0-18,5) 18,2(5,3-20,5) 14 400 62.5 ON/OFF MOU-48HN1 14.1 15.2 11 400 59 ON/OFF MOU-60HN1 17.6 19.1 13 400 59.3 6,35/12,7 (1/4"/1/2") 9,52/15,9 (3/8"/5/8") 9,52/15,9 (3/8"/5/8") 9,52/15,9 (3/8"/5/8") 9,52/15,9 (3/8"/5/8") 12,7/19,0 (1/2"/3/4") 12,7/19,0 (1/2"/3/4") 30 765101717 1539 50 765101718 1867 65 765101719 2692 65 765101720 2974 65 765101721 3105 50 765134716 1615 30 765100322 1809 Page 9 of 16

FILTERS Filters Unit size M5 F7 (bxhxl), mm Code PRICE Code PRICE Domekt-R-200-V 285x130x46 774100091 16 774300060 18 Domekt-R-250-F 278x258x46 774132408 16 774300005 18 Domekt-R-300-V 290x205x46 774100137 16 774300107 18 Domekt-R-400-V 450x210x46 774132410 18 774300007 21 Domekt-R-400-H 410x200x46 774100046 18 774300004 21 Domekt-R-400-F 278x258x46 774132408 16 774300005 18 Domekt-R-450-V 470x240x46 774164415 24 774300013 26 Domekt-R-500-H/V 540x260x46 774100060 26 774300001 31 Domekt-R-600-H 475x235x46 774100108 24 774300014 26 Domekt-R-700-H/V 540x260x46 774100060 26 774300001 31 Domekt-R-700-F 370x360x46 774100154 26 774300104 37 Domekt-CF-250-V 145x350x46 774100129 18 774300095 21 Domekt-CF-250-F 265x250x46 774100130 18 774306667 21 Domekt-CF-400-V 350x235x46 774155061 18 774300012 21 Domekt-CF-500-F 484x250x46 774100166 25 774364273 29 Domekt-CF-700-H/V 390x300x46 774131406 21 774300020 26 Domekt-CF-700-F 400x300x46 774100140 24 774300099 29 Domekt-S-650-F 371x235x46 774100044 24 774300091 29 Domekt-S-800-F 371x287x46 774100100 24 774300092 29 Domekt-S-1000-F 558x287x46 774132406 31 774300051 37 Domekt-PP-300-V 300x200x46 774100090 16 774300052 18 Domekt-PP-450-V 300x200x46 774100090 16 774300052 18 Page 10 of 16

SILENCERS A - Outdoor intake B - Supply air C - Extract indoor D - Exhaust air AGS-d-h-L d - connecting diameter h - insulation thickness L - silencer length Unit size Silencer type Code PRICE Domekt-R-200-V -R-250-F -R-300-V -R-400-H/V -R-450-V A/D AGS-125-50-600-M 354273012 34 B/C AGS-125-50-900-M 354273016 47 A/D AGS-160-50-600-M 354273022 42 B/C AGS-160-50-900-M 354273026 51 Domekt-R-400-F Domekt-R-600-H Domekt-R-500-H/V Domekt-R-700-H/V/F Domekt-CF-250-V Domekt-CF-250-F Domekt-CF-400-V Domekt-CF-500-F Domekt-CF-700-V Domekt-CF-700-H/F Domekt-S-650-F Domekt-S-800-F Domekt-S-1000-F Domekt-PP-300-V Domekt-PP-450-V A/D AGS-200-50-600-M 354273037 47 B/C AGS-200-50-900-M 354273042 55 A/D AGS-250-50-600-M 354273202 56 B/C AGS-250-50-900-M 354273062 72 A/D AGS-125-50-600-M 354273012 34 B/C AGS-125-50-900-M 354273016 47 A/D AGS-160-50-600-M 354273022 42 B/C AGS-160-50-900-M 354273026 51 A/D AGS-200-50-600-M 354273037 47 B/C AGS-200-50-900-M 354273042 55 A/D AGS-250-50-600-M 354273202 56 B/C AGS-250-50-900-M 354273062 72 A AGS-160-50-600-M 354273022 42 B AGS-160-50-900-M 354273026 51 A AGS-200-50-600-M 354273037 47 B AGS-200-50-900-M 354273042 55 A AGS-250-50-900-M 354273062 72 B AGS-250-50-1200-M 354273066 86 A/D AGS-125-50-600-M 354273012 34 B/C AGS-125-50-900-M 354273016 47 Note: Countable acoustic data is: 50dB(A) for exhaust outlet and 40dB(A) for supply outlet. For other parameters use our selection program from www.komfovent.com Page 11 of 16

STANDARD BASE FRAMES Standard frame is 138 mm height, painted in RAL 7035. Regulating feet with rubber pad can be ordered additionally. Air handling unit Frame type Dimensions BxHxL, mm Domekt-R-400-H BF_00_000_465x650 465x138x650 712200542 79 Domekt-R-500-H BF_00_000_590x930 590x138x930 712200541 85 Domekt-R-500-V BF_00_000_590x1070 590x138x1070 712200543 92 Domekt-R-600-H BF_00_000_520x1130 520x138x1130 712200544 92 Domekt-R-700-H BF_00_000_590x930 590x138x930 712200541 85 Domekt-R-700-V BF_00_000_590x1070 590x138x1070 712200543 92 Code PRICE Type Code PRICE Regulating foot (1 pcs.) 782600013 6 Page 12 of 16

OTHER ACCESSORIES Komfovent kitchen hood (only for unit Domekt-R-200) Komfovent kitchen hood (only for unit Domekt-R-200) Type Code PRICE Type Code PRICE White color painted, 392-12 708300121 430 White color painted 708300115 206 Stainless steel 708300117 282 Adapter (only for unit Domekt R 200) Type Code PRICE Adapter, 392-12 710600269 35 Decorative panel (only for Domekt-R-200) Type Code PRICE White color painted 712199840 63 Stainless steel 710300006 79 Decorative panel (only for Domekt-R-200) Type Code PRICE White color painted, 392-12 710300009 72 Stainless steel, 392-12 710300010 97 For diffuser's connection, noise attenuation and air velocity reduction Air distribution box OSD (only for unit Domekt-R-200 for horizontal connection of ducts) Type Code PRICE DPSS-100-125 709100076 41 DPSS-125-125 709100081 43 DPSS-125-160 709100077 45 DPSS-160-160 709100082 52 DPSS-160-200 709100078 54 DPSS-200-200 709100083 69 DPSS-200-250 709100079 72 Type Code PRICE DPSS-250-250 709100084 96 OSD-200VE (100 mm) 712199841 107 OSD2-200VE (125 mm) 712199843 107 Connection box DPSS Outdoor grill LD Dimensions, mm Type Code PRICE d H B b L L i LD-125 white RAL9010 125 215 465 250 110 40 731420061 45 LD-125 black RAL9005 125 215 465 250 110 40 731420060 45 LD-160 white RAL9010 160 250 505 250 110 40 731420063 48 LD-160 black RAL9005 160 250 505 250 110 40 731420062 48 LD-200 white RAL9010 200 300 605 310 110 40 731420065 51 LD-200 black RAL9005 200 300 605 310 110 40 731420064 51 Page 13 of 16

OPTIONAL CONTROL ACCESSORIES UNIT PC CONTROL PING2 FOR C4 CONTROLLER An option to manage and control units via computer when connected to the PC network or Internet. Network module PING2 is intended for connection of KOMFOVENT air handling units to the computer network (Ethernet) or another network (RS-485). SUPPLY AIR DUCT TEMPERATURE SENSOR FOR C6 Applicable for -R-300-V for CAV function activation. Type Code PRICE Type Code PRICE Network module PING2 745200851 197 Temperature sensor 745200933 16 REMOTE UNIT INTENSITY CONTROL (OVR) OVR (Eng. Override - ignore) function is intended for the remote unit's control with an external accessory device. After this function is activated the current unit's mode is ignored and the unit starts working according to the newly set parameters. This function has the highest priority and may operate in every mode, even when the unit is switched off. This function is possible for all units with EC fans just by connecting one of the sensors listed below. Type Parameters Code PRICE Differential pressure switch DTV-500 Pressure range 50-500Pa One change-over contact (NO+NC) 250V AC, 1A Protection class IP54 354501300 18 Detection angle 180 Max. distance 12 m Protection Motion detector PIR180 745231030 18 class IP44 Wall mounted temperature sensor RTT Wall mounted humidity sensor RTH Temperature measuring range 0-50 C One change-over contact (NO+NC) 250V AC, 2A Protection class IP30 Relative humidity measuring range 0-100% One change-over contact (NO+NC) 250V AC, 2A Protection class IP30 744400200 59 744400201 141 Duct mounted humidity sensor DTH Relative humidity measuring range 0-100% One change-over contact (NO+NC) 250V AC, 2A Protection class IP54 744400202 189 CO 2 measuring range 0-2000 ppm Wall mounted CO 2 sensor RTC One change-over contact (NO+NC) 250V AC, 2A 744400203 297 Protection class IP30 CO 2 measuring range 0-2000 ppm Duct mounted CO 2 sensor DTC One change-over contact (NO+NC) 250V AC, 2A 744400204 314 Protection class IP54 Wall mounted air quality sensor RTQ Duct mounted air quality sensor DTQ Air quality measuring range 0-2000 ppm One change-over contact (NO+NC) 250V AC, 2A Protection class IP30 Air quality measuring range 0-2000 ppm One change-over contact (NO+NC) 250V AC, 2A Protection class IP54 744400205 278 744400206 314 Page 14 of 16

OPTIONAL CONTROL ACCESSORIES AIR QUALITY CONTROL (AQ) AQ ventilation intensity control option depends on the external sensor signal. Provides ventilation intensity correction according to the increased CO 2, humidity level, etc. A different AQ function may be set depending on the sensor type, therefore, the intensity of the unit will be regulated accordingly. User can activate this function anytime according to the demand and can also observe the premise's air quality on the panel. This function is possible for all the units with EC fans just by connecting one of the sensors listed below (except units with C4 control system). Type Parameters Code PRICE Wall mounted temperature sensor RST Temperature measuring range 0-50 C Output signal 0...10V DC Protection class IP30 744400207 63 Wall mounted humidity sensor RSH Relative humidity measuring range 0-100% Output signal 0...10V DC Protection class IP30 744400208 145 Duct mounted humidity sensor DSH Relative humidity measuring range 0-100% Output signal 0...10V DC Protection class IP54 744400209 189 Wall mounted CO 2 sensor RSC CO 2 measuring range 0-2000 ppm Output signal 0...10V DC Protection class IP30 744400210 271 Duct mounted CO 2 sensor DSC CO 2 measuring range 0-2000 ppm Output signal 0...10V DC Protection class IP54 744400211 299 Wall mounted air quality sensor RSQ Air quality measuring range 0-2000 ppm Output signal 0...10V DC Protection class IP30 744400212 271 Duct mounted air quality sensor DSQ Air quality measuring range 0-2000 ppm Output signal 0...10V DC Protection class IP54 744400213 297 VARIABLE AIR VOLUME CONTROL (VAV) ( C5 / C6) Unit supplies and exhausts the air volume correspondingly to the ventilation requirements in different premise. Because of frequently changing ventilation demands such air volume's maintenance mode signally reduces unit's exploitation costs. VAV function is possible for all units with EC fans. Type Parameters Code PRICE 0...100/200/300/500/1000/1500/2000/2500 Pa Pressure sensor P2500 354501604 144 24V AC/DC, <1VA, 0..,10V DC, IP54, 0...+50 C Page 15 of 16

HEAD OFFICE: 23 Revenge Road Lordswood Industrial Estate Chatham Kent ME5 8UD Tel: 01634 684419 Fax: 01634 200423 E-mail: chatham@ja-glover.co.uk BIRMINGHAM OFFICE: Units 6 & 7 Coleshill Trade Park Station Road Coleshill Birmingham B46 1JT Tel: 01675 465165 Fax: 01675 465214 E-mail: birmingham@ja-glover.co.uk EAST LONDON OFFICE: Units 11-12 Crescent Court Business Centre North Crescent Road London E16 4TG Tel: 020 7474 2757 Fax: 020 7474 2758 E-mail: stratford@ja-glover.co.uk LEICESTER OFFICE: Unit 6 Crafton Street East Leicester LE1 2DG Tel: 0116 262 8666 Fax: 0116 262 8636 E-mail: leicester@ja-glover.co.uk WEST LONDON OFFICE: 701b Tudor Industrial Estate Abbey Road Park Royal London NW10 7UY Tel: 020 8961 1666 Fax: 020 8961 7666 E-mail: wembley@ja-glover.co.uk SOUTH LONDON OFFICE: Unit A Pioneer Industrial Park Beddington Farm Road Croydon CRO 4XY Tel: 020 8665 7055 Fax: 020 8665 5108 E-mail: croydon@ja-glover.co.uk