Yan Xue 1 and Qingyan Chen 2,1* Abstract

Similar documents
Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Residential ventilation concepts based on the idea of displacement airflow distribution

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

AIRFLOW PATTERN AND PERFORMANCE ANALYSIS OF DIFFUSE CEILING VENTILATION IN AN OFFICE ROOM USING CFD STUDY

DESCRIPTION OF TECHNOLOGY

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Displacement Ventilation

Better Air Dispersion for. Underfloor. Plenums

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Radiant Exchange in Stratified Environments: Considerations and Challenges for Hourly Energy Simulation of UFAD, DV, and Radiant Cooling Systems

Space Air Diffusion II

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Underfloor Air Distribution:

New Convection Correlations for Cooled Ceiling Panels in Room with Mixed and Stratified Airflow

Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

Underfloor Air Conditioning in North America David Arnold Troup Bywaters + Anders/ Director and Regional Chair ASHRAE Region at Large

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Raised Access Floor - (AE Breadth Area)

IMPLEMENTATION OF DISPLACEMENT VENTILATION SYSTEM BY USING A WALL-MOUNTED AIR CONDITIONER

System Using Exhaust Heat from Residential GHPs

K.F. Fong *, C.K. Lee, T.T. Chow

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

The Use Of Attic Space For Cooling and Dehumidification

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

ASHRAE JOURNAL ON REHEAT

ROOM AIR STRATIFICATION IN COMBINED CHILLED CEILING AND DISPLACEMENT VENTILATION SYSTEMS

An analysis of integrated ventilation systems with desiccant wheels for energy conservation and IAQ improvement in commercial buildings

Heat Transfer in Evacuated Tubular Solar Collectors

Effect of the Use Pattern on Performance of Heat Pump Water Heater

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Continuous Commissioning: A Valuable Partner to Retrofit Projects

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

American Society of Heating, Refrigerating and Air-Conditioning Engineers

CLASSIFICATION AND EXPERIMENTATION FOR THE DEVELOPMENT OF DAYLIGHTING SYSTEMS IN COLD AND SNOWY REGIONS

A WEB-BASED SIMULATION TOOL ON THE PERFORMANCE OF DIFFERENT ROOFING SYSTEMS

Copyright 2003 IBACOS, Inc. All rights reserved.

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

Thermal Comfort with Convective and Radiant Cooling Systems

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Cooling load calculations of radiant and all-air systems for commercial buildings

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

The Ed Roberts Campus Berkeley, CA

Comparison of radiant and convective cooling of office room: effect of workstation layout

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

Underfloor Air Distribution in a Commercial High Rise: The New York Times Headquarters

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

To describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Dehumidification: Energy Efficiency Comparisons

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

RADIANT COOLING RESEARCH SCOPING STUDY

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Efficiency of Non-Azeotropic Refrigerant Cycle

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Cork County Energy Agency

design brief This design brief provides an introduction into the design and application of DV. It addresses the following issues:

Experimental study of space cooling using ceiling panels equipped with capillary mats

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

MODELING OF THE SINGLE COIL, TWIN FAN AIR-CONDITIONING SYSTEM IN ENERGYPLUS

European Researcher, 2014, Vol.(75), 5-2

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Transcription:

1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 31 32 33 34 35 36 37 38 Xue, Y. and Chen, Q. 214. Influence of floor plenum on energy performance of buildings with UFAD systems, Energy and Buildings, 79, 74-83. Influence of floor plenum on energy performance of buildings with UFAD systems Yan Xue 1 and Qingyan Chen 2,1* 1 School of Mechanical Engineering, Purdue University, West Lafayette, IN 4797, USA 2 School of Environmental Science and Engineering, Tianjin University, Tianjin 372, China * Tel. (765)496-7562, Fax (765)494-539, Email: yanchen@purdue.edu Abstract The heat transfer through the floor slab in buildings with Under-Floor Air Distribution (UFAD) systems may have a negative impact on the energy performance of these buildings, although very few studies have been reported in the literature. By using an energy simulation program, EnergyPlus, this investigation compared the energy use in a Philadelphia office building with a UFAD system to that with a well-mixed ventilation system. When the heat transfer through the floor slab was taken into consideration, the thermal load of the building with the UFAD system was higher than with the well-mixed system. On the other hand, the higher supply air temperature of the UFAD system enables the use of more free-cooling. The annual energy consumption by the chillers in the building with the UFAD system was 16%-27% lower than with the well-mixed system, but energy consumption by the boiler was 12%-3% higher, and the energy consumption by the fan was 22-5% higher, depending on the manner in which the heat was supplied to the floor plenum. When the UFAD system was used with an un-ducted floor plenum and without heating coils under the diffusers, it consumed slightly more energy than the well-mixed system. 1. Introduction Unlike conventional overhead well-mixed systems, UFAD systems provide directly conditioned air to the occupied zone through diffusers in a raised floor, as shown in Figure 1. Thermal buoyancy causes temperature stratification in the occupied zone, and the air temperature in the lower part of the zone is lower than that in the upper part. Therefore, UFAD systems are believed to use less energy for cooling [1,2]. In addition, the thermal stratification in a room with a UFAD system can create better indoor air quality than in a room with a well-mixed air distribution system [3,4]. A UFAD system also allows individual control of airflow rate in order to meet the thermal comfort requirements of different occupants [5,6] and can thus provide a more comfortable environment than overhead well-mixed systems [7]. However, if the air supply and return in the plenums are un-ducted or un-insulated, the air temperature in the floor plenum is very low during the cooling mode, while the ceiling plenum is very warm. The temperature 1

39 4 41 42 43 44 45 46 47 48 49 5 51 52 53 54 55 56 57 58 59 6 61 62 63 64 65 66 67 68 69 7 71 72 73 74 75 76 difference between the floor plenum and downstairs ceiling plenum leads to heat transfer across the floor slab, as shown in Figure 1,which may have an impact on energy use. Studying the influence of the floor plenum on cooling load and energy use requires that the energy flow between the occupied zone and the floor plenum also be considered, so do the thermal stratification in the occupied zone [8]. Many previous researchers have analyzed the thermal stratification, and various models have been developed to predict the air temperature stratification in rooms with UFAD systems [9-15]. Air flow and heat transfer in the floor plenum contribute further complexity to the simulations. Linden [16] determined that there was a significant air temperature differential and air velocity variation in the floor plenum. These nonuniform air temperature and flow distributions could affect heat transfer in the floor plenum. In regard to the impact of the floor plenum on the energy performance of a UFAD system, Bauman et al. [17] found that the heat transfer in the floor plenum can be as high as 3%-4% of the room cooling load. However, this conclusion was made on the basis of a simplified first-law model that may not be accurate. Schiavon et al. [8] indicated that the presence of a raised floor changed the cooling load profile greatly, and the peak cooling load could vary in the range of 7 to + 4% as compared to the load without the raised floor. However, their study did not address heating. Lee et al. [18] simulated a three-floor office building with a UFAD system on two design days: a summer day and a winter day. They found that thermal decay in the floor plenum could result in a higher supply airflow rate and greater use of energy by the fans and chiller. However, the non-uniform flow in the floor plenum was not taken into account in their study. The current investigation systematically studied the influence of heat transfer through a floor slab on the energy performance of an office building with a UFAD system. The objective was to accurately simulate the thermal load and energy use as influenced by the floor plenum and to assess the impact of non-uniform flow in the floor plenum on energy modeling. 2. Method 2.1. Load and energy simulations for an office building To accurately study the impact of the floor plenum on energy performance, this investigation used EnergyPlus [19] as the main tool with the implementation of a room air stratification model. To simplify the study, this investigation simulated a typical middle floor, Floor N, in a multifloor building, as shown in Figure 2, rather than an entire building. Accurate simulations must take into account (1) the vertical air temperature stratification in the room air and (2) the nonuniform air distribution in the floor plenum. 2

77 78 79 8 81 82 83 84 85 86 87 88 89 9 91 92 93 94 95 96 97 98 99 1 11 12 13 14 15 16 17 18 19 11 111 112 113 114 115 2.2. Vertical air temperature stratification in the simulated room Because the EnergyPlus program did not calculate the room air distribution, the air temperature model from Lin et al. [12], implemented into the program by Liu et al. [2], was applied to calculate the vertical air temperature profiles in the room. The model predicts the vertical temperature profiles by simulating the buoyancy plumes from internal heat sources and the jets from air supply diffusers. The buoyancy plumes generate the air stratification and the jets lead to air mixing. 2.3. Non-uniform air distribution in the floor plenum Along with the air temperature stratification in the room, non-uniform air velocity and air temperature in the floor plenum also contribute additional complexity to the simulation[16]. To simulate the non-uniform flow in the floor plenum, Computational Fluid Dynamics (CFD) can be used in combination with the energy calculation [21,22], but doing so is too computationally demanding. Instead, this investigation used a multizone model [23] to simulate the non-uniform air distribution in the floor plenum for coupling with EnergyPlus. The floor plenum was divided into several subzones according to the temperature distribution determined by CFD simulation. The air velocity and temperature differences among these subzones represented the non-uniform air temperature in the floor plenum. The simulation results of the multizone model were then compared to a single zone model in which the floor plenum had uniform air distribution. The difference between them could indicate the impact of the non-uniform air distribution on the energy modeling. 2.4. Validation of the computer models The computer models described above use a number of approximations, and coupling them with EnergyPlus can lead to additional errors. The models needed to be validated before they could be used to simulate the cooling load and energy use in the building. This investigation used an environmental chamber as shown in Figure 3 to measure the air and surface temperatures in the floor plenum and the surface temperatures in the room. This chamber had dimensions of 4.8 m in length, 4.2 m in width, and 2.73 m in height, including a floor plenum with a height of.3 m. The room contained several pieces of furniture, lighting fixtures, and heated boxes that were used to simulate internal loads such as electrical appliances, occupants, etc. The supply air duct was connected to the floor plenum, and two linear grille diffusers were installed in the floor. The walls and ceiling were well insulated with a thermal resistance of 5.45 m 2 -K/W. The raised floor panels were made of.1 m thick lightweight concrete with a thermal resistance of.16 m 2 -K/W. A double-glazed window with dimensions of 3

116 117 118 119 12 121 122 123 124 125 126 127 128 129 13 131 132 133 134 135 136 137 138 139 14 141 142 143 144 145 146 147 148 149 15 151 152 153 154 4.65 m in width and 1.55 m in height and a thermal resistance of.25 m 2 -K/W was installed in the east wall of the chamber. Table 1 shows the power levels of the internal heat sources. Eight anemometers were placed in the middle of the floor plenum (.15 m from the slab) for measuring air temperature and velocity in the plenum. Temperatures of the different surfaces of the floor plenum and room were measured by a number of T-type thermocouples. The experiment was conducted under steady-state conditions in summer. The inlet temperature was 17.3 C, and the air change rate was 6 ACH. 3. Validation of the computer models and case setup 3.1. Validation of the computer models The CFD simulations for this investigation were performed for the floor plenum using a commercial software program FLUENT [24]. The CFD results provided greater understanding of the temperature distribution in the floor plenum, which was the basis of the multizone model. Figures 4 and 5 show the air velocity and temperature profiles, respectively, in two sections of the floor plenum. The air supply was located on the bottom wall under Position 7, as shown in Figure 6, and therefore Positions 3 and 7 were located in the jet region. As a result, the air velocities measured at these positions were high, and the air temperatures were low. The agreement between the CFD results and experimental data for air velocity and temperature is quite good. Figure 6 shows a non-uniform air temperature distribution in the floor plenum. Our EnergyPlus simulation divided the floor plenum into three subzones, as shown in Figure 6, for studying the impact of the non-uniform air temperature distribution on the load. Figure 5 depicts the air temperature profiles calculated with the multizone model in the two sections of the floor plenum, and again they are in good agreement with the measured data. The results shown in Figures 5 and 6 have validated the computer models for calculating air temperature in the floor plenum. Table 2 further compares the air temperature from the diffusers, air temperature at the exhaust, and EnergyPlus-simulated surface temperatures with the measured data. The columns of "Error" show the percentage difference between the experimental measurements and simulation results. Once again, agreement between the simulations and measurements is quite good. Therefore, the EnergyPlus program with the multizone air models can be used to predict thermal load and energy use in buildings. In addition, Table 2 shows the results obtained by EnergyPlus with the assumption of uniform air temperature in the floor plenum (one subzone). The air temperature with one subzone differed by only.5 K from that with three subzones, which was insignificant, although the air temperature between zones can differ by 2 K, as shown in Figure 6. Thus, the 4

155 156 157 158 159 16 161 162 163 164 165 166 167 168 169 17 171 172 173 174 175 176 177 178 179 18 181 182 183 184 185 186 187 188 189 19 191 192 impact of the non-uniform air distribution in the floor plenum on the energy simulation was very limited and our subsequent simulations used only one zone for the floor plenum. 3.2. Case description for a building with UFAD systems in Philadelphia Using the validated EnergyPlus model, this investigation conducted energy simulations for a mid-level floor of a multi-floor office building in Philadelphia. An office area with dimensions of 3 m 4 m 3.7 m, as shown Figure 7, was divided into five thermal zones: a central zone and four perimeter zones, because solar radiation would have a significant impact on the perimeter zones. The perimeter zones had a width of 5. m [25]. The construction and material information for the building envelope were taken from the default data for Chicago in EnergyPlus Version 7. Figure 8 shows the internal load profiles for weekdays and Saturdays. This study further assumed that the building was completely closed on Sundays, without an internal heat load. This investigation simulated three different scenarios for the office building, as shown in Figure 9: a well-mixed ventilation system, a UFAD system without heating coils in the diffusers, and a UFAD system with heating coils in the diffusers [26]. For each of the two UFAD scenarios, three cases were simulated with different floor plenum configurations: completely ducted floor plenums; partially ducted floor plenums (ducted floor plenums in the perimeter zones and an unducted core zone); and completely un-ducted floor plenums. The arrangement led to a total of seven simulation cases, as shown in Table 3. All of the cases used the same HVAC system, which incorporated an electric chiller and a gas boiler. The system used variable-air-volume control and an economizer. The thermostat in the occupied zone was set at 21 C during the winter and 24 C during the summer. The minimum fresh air rate was.3 L/(s m 2 ), in accordance with ASHRAE Standard 62.1-21 for indoor air quality [27]. For mixed ventilation, the supply air temperature was 13 C for cooling and 32 C for heating [28]. In the UFAD system without heating coils in the diffusers, the supply air temperature was 17 C [1,29] for cooling and 32 C for heating. In the UFAD system with heating coils, the air supply temperature from the HVAC system was 17 o C all year round. When heating was called for, the air was heated to 32 C by the heating coils. The HVAC system operated from 6: to 22:. 4. Results In order to explain the effects of the heat transfer through slabs on the energy performance of buildings, this section will show the heat flux profiles across slabs and analyze their influence on the thermal loads. Then the year-round energy consumption results will be reported. 5

193 194 195 196 197 198 199 2 21 22 23 24 25 26 27 28 29 21 211 212 213 214 215 216 217 218 219 22 221 222 223 224 225 226 227 228 229 23 231 232 4.1. Thermal load simulations for the building Figure 1 shows the heat flux at the two surfaces of the floor slab in the office building on July 21, the summer design day in EnergyPlus. The sum of the heat transfer at the two surfaces is equal to the thermal storage in the slab. For cooling, the heating coils in the diffusers were not activated, and thus the two UFAD scenarios were identical. For the well-mixed system, from 8: to16:, heat was transferred from the occupied zone to the slab, as shown in Case 1 of Figure 1(a, b). In the perimeter zones as shown in Figure 1(a), this heat transfer was caused by the high level of radiation from the direct sunlight on the floor slab and the internal heat sources, With the UFAD systems, however, the radiation from the sun and the internal load had no direct impact on the slab. Thus, the heat transfer profiles in these cases were very different from those with the well-mixed system. In the thermal zones with ducted floor plenums, there was a small amount of heat transfer across the floor slabs. As for the un-ducted UFAD systems, cool air was supplied to the floor plenum, and the downstairs ceiling plenum was warm. The significant temperature difference between the two sides of the floor slab led to a high heat transfer rate from the downstairs ceiling plenum to the floor slab and further to the floor plenum. In the wellmixed system, from 6: to 8: and 18: to 22:, when the internal load and solar radiation were small, heat was transferred from the floor slab to the room air as a result of the high floor slab temperature. In the UFAD system, however, the total air supply was lower during these two periods than during the occupied hours, and thus the heat transfer from the floor plenum to the slab was smaller. Despite the drastic difference in heat transfer profiles between the well-mixed ventilation and UFAD, the cooling loads of these systems had similar shapes on the summer design day, as shown in Figure 11. For the winter heating, the heat transfer between the well-mixed system and UFAD system could be different but the heating load is also very similar as shown in the cooling scenario. Due to limited space in this paper, the detailed results are not presented here. 4.2. Annual energy consumptions of the building Figures 12 and 13 illustrate the monthly energy consumption by the chiller and boiler, respectively, in the HVAC system in year-round simulations. With the well-mixed ventilation system, more energy was used by the chiller, especially during the shoulder seasons when the outdoor air temperature was suitable for free-cooling. In the two UFAD scenarios, the levels of electricity consumption by the chillers were almost identical. They were lower than that in the well-mixed system by 27% for the ducted cases (Cases 2 and 5), 23% for the partially ducted cases (Cases 3 and 6), and 16% for the un-ducted cases (Cases 4 and 7). The percentage numbers are based on the UFAD systems. However, the natural gas consumption levels by the boiler with 6

233 234 235 236 237 238 239 24 241 242 243 244 245 246 247 248 249 25 251 252 253 254 255 256 257 258 259 26 261 262 263 264 265 266 267 268 269 27 271 272 the UFAD systems were higher than that with the well-mixed system. Without heating coils under the diffusers, the boiler energy consumption in the UFAD system was higher than that in the well-mixed system by 18% in the completely ducted case (Case 2), 21% in the partially ducted case (Case 3), and 3% in the un-ducted case (Case 4). When there were heating coils under the diffusers, the boiler energy consumption in the UFAD system was higher than that in the well-mixed system by 12% in the completely ducted case (Case 5) and by 18% in the partially ducted (Case 6) and the un-ducted (Case 7) cases. The levels of electricity consumption by the fans in the building s HVAC system were 22-5% higher with the UFAD systems than with the well-mixed system by using the energy use of the UFAD system as the reference, as shown in Figure 14. This difference occurred because the supply air temperature in the UFAD systems was higher than that in the well-mixed ventilation system, and a higher airflow rate is required in order to remove the same amount of heat. A comparison of the different cases indicates that the ducting of floor plenums can reduce energy consumption by the chiller and the boiler, and that this effect is more significant in perimeter zones. Furthermore, during the heating mode, supplying warm air directly to the floor plenum without ducts is not recommended because heat flow in the plenum would cause significant energy loss. In addition to ducting of the floor plenums, the use of heating coils under the diffusers is recommended in order to reduce energy use by the boiler. Using the energy consumption data, this investigation conducted a cost analysis for these cases with EnergyPlus. Table 4 shows the monthly price of natural gas [3]. The cost of electricity [3] was calculated using the block method shown in Table 5. The tax rate was 8%, and the monthly service fee for electricity was $8.81. Table 6 shows the annual electricity costs for the chiller and fans and the gas costs for the boiler. For the same building, the use of electricity by lights and electrical equipment was exactly the same with either the well-mixed ventilation or UFAD. Variations in energy consumption arose from the HVAC systems. Because only the perimeter zones of the building required heating and natural gas was much cheaper than electricity, the gas costs for the boiler were much lower than the electricity costs for the chiller. As discussed above, energy consumption by the chiller was greater with the wellmixed system than with the UFAD systems. Therefore, as shown in Table 6, chiller operation was more expensive in the well-mixed case (Case 1) than in the UFAD cases (Cases 2-6). Among the UFAD cases, those with un-ducted floor plenums (Cases 4 and 7) had higher electricity costs than the other cases. However, the addition of heating coils under the diffusers did not contribute significantly to the electricity costs. Although chiller operation was cheaper in the UFAD cases, both the gas costs for the boiler and the electricity costs for the fan were higher with the UFAD systems than with the well-mixed 7

273 274 275 276 277 278 279 28 281 282 283 284 285 286 287 288 289 29 291 292 293 294 295 296 297 298 299 3 31 32 33 34 35 36 37 38 39 31 311 system. These higher costs are consistent with the energy consumption levels shown in Figures 13 and 14. In the UFAD cases, the addition of heating coils under the diffusers (Cases 5-7) reduced the gas cost for the boiler, especially in the cases with un-ducted floor plenums. The total energy cost for a building with a UFAD system could be lower than that with a well-mixed system if the floor plenum was ducted. Unfortunately, ducting of the floor plenum is not a common practice at present. 5. Conclusions Using validated computer models, this investigation assessed the energy performance of a building in Philadelphia with several different UFAD systems and with a well-mixed ventilation system. The study led to the following major findings: The airflow and air temperature distribution in the floor plenum can be highly nonuniform. The non-uniform air temperature distribution can be calculated with the use of a simple subzone model. By comparing the supply air temperature, exhaust air temperature, and enclosure surface temperatures between the multizone model and the single zone model, this study found that the impact of the non-uniform air temperature distribution on the energy modeling is small. In cooling situations, the temperature difference between the cold air in the floor plenum and the warm air in the downstairs ceiling plenum can result in significant heat transfer through the floor slab in a building with a UFAD system. This heat transfer leads to a slightly higher cooling load than with a well-mixed ventilation system. In heating situations, when a UFAD system is used in the building without heating coils in the air supply diffusers, the presence of warm air in the floor plenum can lead to a higher heating load than that with the well-mixed ventilation system. This increased heat load is again attributed to heat transfer from the plenum air to the floor slab. By conducting an annual energy analysis for the building, this investigation found that the chiller used 16%-27% less energy with the UFAD systems than with the well-mixed system because of the use of free cooling during the shoulder seasons. However, the boiler consumed 18%-3% more energy with the UFAD systems because of heat loss in the floor plenum. The use of heating coils in the air supply diffusers and/or the utilization of ducts for supplying air to the floor plenum can reduce energy use by the boiler. Finally, because the UFAD systems had a higher supply air temperature for cooling, the total supply airflow rate was higher than that with the well-mixed ventilation system. As a result, energy consumption by the fans in the UFAD systems was 22-5% higher. The total energy cost for a UFAD system with un-ducted floor plenums and without heating coils under the diffusers could be slightly higher than that for a well-mixed system. Either ducting the floor plenums or using the heating coils under the diffusers would reduce the energy cost. However, ducting the floor plenums would increase the 8

312 313 314 315 316 317 318 319 32 321 322 323 324 325 326 327 328 329 33 331 332 333 334 335 336 337 338 339 34 341 342 343 344 345 346 347 348 349 35 351 352 353 354 initial investment and maintenance costs. Therefore, although the UFAD system with completely ducted floor plenums and with heating coils (Case 5) had the lowest energy costs, the partially ducted UFAD system with heating coils (Case 6) would be the most favorable one. Acknowledgement This research was funded partially by the Energy Efficient Building Hub led by the Pennsylvania State University and funded by the U.S. Department of Energy and other government agencies, where Purdue University was a subcontractor to the grant. References [1] F. Bauman, T. Webster, Outlook for Underfloor Air Distribution, ASHRAE Journal 43 (6) (21) 18-27. [2] Y. Cheng, J. Niu, X. Liu, N. Gao, Experimental and Numerical Investigations on Stratified Air Distribution Systems with Special Configurations: Thermal Comfort and Energy Saving, Energy and Buildings 64 (213) 154-161. [3] D. Faulkner, W.J. Fisk, D.P. Sullivan, Indoor Airflow and Pollutant Removal in a Room with Floor-Based Task Ventilation: Results of Additional Experiments, Building and Environment 3(3)(1995) 323-332. [4] C. Shen, N. Gao, T. Wang, CFD Study on the Transmission of Indoor Pollutants under Personalized Ventilation, Building and Environment 63 (213) 69-78. [5] E.A. Arens, F.S. Bauman, L.P. Johnston, H. Zhang, Testing of Localized Ventilation Systems in a New Controlled Environment Chamber, Indoor Air 3 (1991) 263-281. [6] A. Hedge, A.T. Michael, S.L. Parmelee, Reactions of Office Workers and Facilities Managers to Underfloor Task Ventilation in Offices, Journal of Architectural and Planning Research 1(3) (1993) 23-218. [7] G. Kim, L. Schaefer, T.S. Lim, J.T. Kim, Thermal Comfort Prediction of an Underfloor Air Distribution System in a Large Indoor Environment, Energy and Buildings 64 (213) 323-331. [8] S. Schiavon, K.H. Lee, F. Bauman, T. Webster, Influence of Raised Floor on Zone Design Cooling Load in Commercial Buildings, Energy and Buildings 42 (21) 1182-1191. [9] H. Ito, N. Nakahara, Simplified Calculation Model of Room Air Temperature Profile in Under-Floor Air-Conditioning System, Society of Heating, Air Conditioning and Sanitary Engineers of Japan, proceedings of the International Symposium on Room Air Convection and Ventilation Effectiveness (ISRACVE), held at the University of Tokyo(1992) 183-188. [1] J. Lau, Q. Chen, Floor-Supply Displacement Ventilation for Workshops, Building and Environment 42 (27) 1718-173. [11] K.S. Lee, Air Distribution Effectiveness and Thermal Stratification with Stratified Air Distribution Systems, Ph.D. thesis, Purdue University, West Lafayette, 211. [12] Y.J.P. Lin, P.F Linden, A Model for an Under Floor Air Distribution System, Energy and Buildings 37 (25) 399-49. 9

355 356 357 358 359 36 361 362 363 364 365 366 367 368 369 37 371 372 373 374 375 376 377 378 379 38 381 382 383 384 385 386 387 388 389 39 391 392 393 [13] Q.A. Liu, P.F. Linden, The Fluid Dynamics of an Underfloor Air Distribution System, J. Fluid Mech 554 (26) 323-341, Cambridge University Press, United Kingdom. [14] Q. Kong, B. Yu, Numerical Study on Temperature Stratification in a Room with Underfloor Air Distribution System, Energy and Buildings 4 (28) 495-52. [15] G. Xue, K. Lee, Z. Jiang, Q. Chen, Q., Thermal Environment in Indoor Spaces with Under- Floor Air Distribution Systems: Part 2. Determination of Design Parameters (1522-RP), HVAC&R Research 18:6 (212) 1192-121. [16] P.F. Linden, I. Kanda, D. Yamaguchi, Flow in an Underfloor Plenum, 24 IBPSA-USA National Conference, Boulder, CO. [17] F. Bauman, H. Jin, T. Webster, Heat Transfer Pathways in Underfloor Air Distribution (UFAD) Systems, ASHRAE Transaction 112 (26) Part 2. [18] K.H. Lee, S.Schiavon, F. Bauman, T. Webster, Thermal Decay in Underfloor Air Distribution (UFAD) Systems: Fundamentals and Influence on System Performance, Applied Energy 91 (212) 197-27. [19] EnergyPlus, EnergyPlus Engineering Reference, University of Illinois and Ernest Orlando Lawrence Berkeley National Laboratory, 212. [2] Q.A. Liu, P.F. Linden, The EnergyPlus UFAD Module, Third National Conference of IBPSA-USA, Berkeley, California, 28. [21] Z. Zhai, Q. Chen, Numerical Determination and Treatment of Convective Heat Transfer Coefficient in the Coupled Building Energy and CFD Simulation, Building and Environment 36(8) (24) 1-19. [22] H. Xu, J. Niu, Numerical Procedure for Predicting Annual Energy Consumption of the Under-Floor Air Distribution System, Energy and Buildings 38 (26) 641-647. [23] G.N. Walton, Thermal Analysis Research Program Reference Manual, NBSSIR 83-2655, National Bureau of Standards, 1983. [24] FLUENT 6.3 Documentation, ANSYS Fluent Inc., Lebanon, NH, 25. [25] O.T. Karaguzel, K.P. Lam, Development of Whole-Building Energy Performance Models as Benchmarks for Retrofit Projects, 211 Winter Simulation Conference. [26] CBE, http://cbe.berkeley.edu/underfloorair/techoverview.htm (accessed Jan. 214). [27] ASHRAE Standard 62.1-21, Ventilation for Acceptable Indoor Air Quality, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA. [28] E.C. Montanya, Performance of Underfloor Air Distribution Systems. Temperature Stratification and Ventilation Effectiveness in the Child Development Centre, Master s thesis, University of Calgary, Alberta, Canada, 29. [29] K.H. Lee, Supply Air Temperature Impact in Underfloor Air Distribution Systems under Korean Climate Conditions: Energy, Humidity and Comfort, Energy and Buildings 58 (213) 363-371. [3] EnergyPlus Example File Generator, National Renewable Energy Laboratory (NREL), 212. 394 1

395 396 397 398 399 4 Table 1.Power inputs of the lights and heated boxes. Number Power [W] 1 43. 2 44. Lighting 3 26.5 4 43.5 1 93.3 Heated boxes for manikins 2 84. 1 65. Heated boxes for equipment 2 65. 3 65. Table 2.Comparison of simulated and measured temperatures for the environmental chamber. Locations Experimental measurements 11 E+ simulation with1- zone floor plenum (uniform air temperature) E+ simulation with 3- zone floor plenum (non-uniform air temperature) Error (%) Error (%) Air at the diffusers 2.2 19.9 1.5 2.4 1. Air at the exhaust 24.2 24.4.8 24.2. Slab surface (facing floor plenum) 23.7 23.6.4 23.6.4 Ceiling surface 24.3 24.7 1.6 25.4 4.5 North wall of floor plenum 23.8 22.7 4.6 23.7.4 South wall of floor plenum 22.7 22.7. 23. 1.3 West wall of floor plenum 23.5 22.7 3.4 23. 2. East wall of floor plenum 22.7 22.7. 23. 1.3 North wall of room 25.1 25.2.4 25.5 1.6 South wall of room 24.1 25.2 4.6 25.5 5.8 West wall of room 24.7 25.2 2. 26.4 6.9 East wall of room 25.4 25.2.8 25.5.4 Table 3.Simulated cases. Case Ventilation system Floor plenum Heating coils under configuration diffusers 1 Well-mixed N/A N/A 2 UFAD Completely ducted No 3 UFAD Ducted perimeter zones Un-ducted core zone No 4 UFAD Completely un-ducted No 5 UFAD Completely ducted Yes 6 UFAD Ducted perimeter zones Un-ducted core zone Yes 7 UFAD Completely un-ducted Yes

41 Table 4. Monthly natural gas price (unit: $/kwh). Jan Feb Mar Apr May Jun.344.343.343.346.371.4 Jul Aug Sep Oct Nov Dec 42 43 44 45 46.391.386.376.375.322.331 Table 5.Electricity price (unit: $/kwh). Summer (Jun Sep)and Winter (Oct - May) Charge Energy [$/kwh] Transition [$/kwh] Distribution [$/kwh] < 8 hrs..188.669.344 8-16 hrs. Summer:.592 Summer:.319 Summer:.162 Winter:.428 Winter:.25 Winter:.13 16-4 hrs..428.25.13 > 4 hrs..275.95.46 Case Table 6. Annual energy cost for the whole building in different cases. Electricity cost Electricity cost for Gas cost for for the chiller the fans the boiler ($) ($) ($) Total cost as a percentage of Case 1 (%) 1 4275 369 244 1. 2 3425 481 3 86.1 3 3553 66 32 92.7 4 3797 756 372 1.7 5 3424 481 274 85.7 6 3553 659 29 92.4 7 3814 744 297 99.6 12

47 48 49 41 411 412 413 414 415 416 417 418 419 42 421 422 423 424 425 426 427 428 429 43 431 432 433 434 435 436 437 438 Ceiling plenum Occupied zone T room = T plenum Floor slab Floor plenum Heat transfer Ceiling plenum Figure 1.Schematics of well-mixed (left) and UFAD (right) systems. Return plenum Room Floor plenum Floor plenum Return plenum Room Floor plenum Figure 2. Floor N in a multi-floor building with a UFAD system. 439 13

Lights Exhaust Room Heated boxes for manikin and equipment Desk Diffusers North Floor plenum 44 441 442 Conditioned air inlet Figure 3.Schematic of the environmental chamber. 443 444 445 446 447 448 449 45 451 452 453 454 1 2 3 4 5 6 7 8 y x U[m/s] Experiment Simulation 1.6 1.2.8 3.4 1 2 4. 1 2 3 4 5 x[m] U[m/s] Experiment Simulation 1.6 1.2 7.8.4 8 5 6. 1 2 3 4 5 x[m] 455 456 Figure 4. Comparison of CFD results with experimental data for air velocity in two sections of the floor plenum (horizontal cross-section of the plenum at.15m above the floor). 457 14

458 CFD Experiment E+ (three subzones) T[ ] 25 24 23 22 21 2 19 18 17 1 2 x[m] 3 4 5 T[ ] 25 24 23 22 21 2 19 18 17 Experiment CFD E+ (three subzones) 1 2 3 4 5 x[m] 459 46 Figure 5. Comparison of measured air temperature with that computed by CFD and by the multizone model in two sections of the floor plenum 461 (K) 462 463 464 465 Figure 6.Air temperature distribution at.15m above the floor slab as simulated by CFD, and division of the plenum into three subzones. 15

466 467 468 5.m 4.m N 469 47 5.m W Central Zone E 5.m 3.m 471 472 473 474 475 476 477 S 5.m (a). Top view of thermal zone layout. Ceiling Plenum.7m Ceiling Plenum Room 3.m Room Floor Plenum.4m 3.m.3m 478 479 48 481 482 483 484 W/m 2 12 1 8 6 4 2 (b). Side view of thermal zone layout. Figure 7.Medium-sized office building in Philadelphia. Internal heat on weekdays Electric Lights Occupancy : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: Time/h W/m 2 6 Figure 8.Internal heat load of the office building on weekdays (left) and Saturdays (right). 5 4 3 2 1 Internal heat on Saturdays Electric Lights Occupancy : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: Time/h 16

485 486 487 488 489 49 491 492 493 494 495 496 497 498 499 5 Supply air Diffuser Return air Exhaust Exhaust Supply air Return air Diffuser Exhaust Supply air (a) (b) (c) Return air Diffuser Heating coil Figure 9. Simulated scenarios: (1) well-mixed ventilation system, (2) UFAD system without heating coils in the diffusers, and (3) UFAD system with heating coils in the diffusers. 51 Heat flux [W/m 2 ] 15 1 5-5 -1-15 Perimeter zones Heat flux from room/floor plenum to slab 2/5.UFAD (completed ducted) 3/6.UFAD (ducted perimeter zones) 4/7.UFAD (completed un-ducted) : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: Time[h] Heat flux [W/m 2 ] 15 1 5-5 -1-15 Core zone Heat flux from room/floor plenum to slab 2/5.UFAD (completed ducted) 3/6.UFAD (un-ducted core zone) 4/7.UFAD (completed un-ducted) : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: Time[h] 52 (a) (b) 17

53 54 Heat flux [W/m 2 ] 15 1 5-5 -1-15 Perimeter zones Heat flux from ceiling plenum to slab 2/5.UFAD (completed ducted) 3/6.UFAD (ducted perimeter zones) 4/7.UFAD (completed un-ducted) : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: Time[h] (c) Heat flux [W/m 2 ] 15 1 5-5 -1-15 Core zone Heat flux from ceiling plenum to slab 2/5.UFAD (completed ducted) 3/6.UFAD (un-ducted core zone) 4/7.UFAD (completed un-ducted) : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: (d) Time[h] 55 56 57 58 59 51 511 512 513 514 515 516 Figure 1. Heat transfer across the floor slab of the office building on the summer design day - a weekday. Refer to Table 3 for case descriptions. (a) Heat flux from the room/floor plenum to the floor slab in perimeter zones, (b) Heat flux from the room/floor plenum to the floor slab in the core zone, (c) Heat flux from the downstairs ceiling plenum to the floor slab in perimeter zones, and (d) Heat flux from the downstairs ceiling plenum to the floor slab in core zones (right) Cooling load [W/m 2 ] 7 6 5 4 3 2 1 Perimeter zones_cooling load 2/5.UFAD (completed ducted) 3/6.UFAD (ducted perimeter zones) 4/7.UFAD (completed un-ducted) : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: Time[h] (a) Perimeter zones Time[h] (b) Core zone Figure 11. Cooling loads on the summer design day for the office building with different ventilation systems. The numbers are for different cases as described in Table 3. Cooling load [W/m 2 ] 7 6 5 4 3 2 1 Core zone_cooling load 2/5.UFAD (completed ducted) 3/6.UFAD (un-ducted core zone) 4/7.UFAD (completed un-ducted) : 2: 4: 6: 8: 1: 12: 14: 16: 18: 2: 22: 18

517 518 519 52 521 522 523 524 525 Electric Consumption [kwh] Gas Consumption [kwh] 8 7 6 5 4 3 2 1 Chiller energy consumption No heating coils in diffusers 2.UFAD (completed ducted) 3.UFAD (partially ducted) 4.UFAD (completed un-ducted) 1 2 3 4 5 6 7 8 9 1 11 12 Month 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 11 12 Month Figure 12.Monthly energy consumption by the chiller in the building s HVAC system.the numbers are for different cases as described in Table 3. 4 35 3 25 2 15 1 5 Boiler energy consumption No heating coils in diffusers 2.UFAD (completed ducted) 3.UFAD (partially ducted) 4.UFAD (completed un-ducted) 1 2 3 4 5 6 7 8 9 1 11 12 1 2 3 4 5 6 7 8 9 1 11 12 Month Month Figure 13.Monthly energy consumption by the boiler in the building s HVAC system. The numbers are for different cases as described in Table 3. Electric Consumption [kwh] Gas Consumption [kwh] 4 35 3 25 2 15 1 5 Chiller energy consumption With heating coils in diffusers 5.UFAD (completed ducted) 6.UFAD (partially ducted) 7.UFAD (completed un-ducted) Boiler energy consumption With heating coils in diffusers 5.UFAD (completed ducted) 6.UFAD (partially ducted) 7.UFAD (completed un-ducted) 526 19

527 528 529 53 Electric Consumption [kwh] 8 7 6 5 4 3 2 1 Fan energy consumption No heating coils in diffusers 2.UFAD (completed ducted) 3.UFAD (partially ducted) 4.UFAD (completed un-ducted) 1 2 3 4 5 6 7 8 9 1 11 12 1 2 3 4 5 6 7 8 9 1 11 12 Month Month Figure 14.Monthly energy consumption by the fans in the building s HVAC system.the numbers are for different cases as described in Table 3. Electric Consumption [kwh] 8 7 6 5 4 3 2 1 Fan energy consumption With heating coils in diffusers 5.UFAD (completed ducted) 6.UFAD (partially ducted) 7.UFAD (completed un-ducted) 2