INSTALLATION MANUAL. FLA 2 model E#4 L=1290 FLA 2 model E#4 REMOTE L=1290. Automatic fuel pump

Similar documents
USER S MANUAL. WallFire. Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB750. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

USER S MANUAL LINCOLN PF Manufactured by: Planika Sp. z o.o. ul. Bydgoska Brzoza Poland

USER S MANUAL. Fire Line Automatic 3. Manufactured by Planika Sp. z o.o. ul. Bydgoska Brzoza Poland. I0773#05 of

LATA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

TAB. Ventless Ethanol Fireplace. User s Manual

LIMA. Ventless Ethanol Fireplace. User s Manual Installation Instructions

ATER SS. Ventless Ethanol Fireplace. User s Manual Installation Instructions

REMOTE CONTROLLED BIOETHANOL BURNER USER GUIDE

Instruction manual Safety instructions. Bio-fireplace

User s Manual & Safety Instructions Read Carefully Before Use

Braga Free Standing Floor Indoor Outdoor Ethanol Fireplace User s Manual Model: GF202100

Vigo Ventless Tabletop Bio Ethanol Fireplace. User s Manual. Model: GF301801

Cavo Tabletop Ventless Bio Ethanol Fireplace. User Manual. Model: GF301900BK (BLACK) GF301900W (WHITE)

INSTALLATION & USER INSTRUCTIONS

Electron Microscopy Sciences. INSTRUCTIONAL MANUAL CAT & Step Up Slide Warmer

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Electric Fireplace Instruction Manual

Model No: Little Devil II (inc ss)

INSTALLATION & USER INSTRUCTIONS

Avila Contemporary Indoor Outdoor Ethanol Fireplace. User s Manual. Model: GF201500

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

PERSONAL SIZE FIREPLACE

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Wall Mount Electric Fire Place with Remote Control

Instruction Manual for Wall Mounted Fireplace, Models: ARC 103A & VAGUE 101A

SMART BIO ETHANOL ELECTRONIC BURNER

40 Built-in Electric Fireplace Operating and Installation Instructions

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

INSTALLATION AND OPERATING INSTRUCTIONS

WARNING FIRE OR EXPLOSION HAZARD.

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

by PRIMUS Portable Buddy Compact Propane Heater User Manual and Product Specifications

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Lo-Carbon SELV Tempra

Safety Warnings & Advice 3 Your Blast Vac Pro 4 Care & Cleaning 13 Using Your Vacuum 8 Troubleshooting 14 Guarantee 14 Technical Information 15

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

arrangements of products

VERNON ELECTRIC FIREPLACE

Electric Fireplace. Electric Fireplace

Installation instructions for the T 9820 Gas Dryer

INSTALLATION & USER INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

OPERATING INSTRUCTIONS AND OWNER S MANUAL PORTABLE BUDDY RADIANT HEATER

Owners Manual. Australia s original Outdoor brand. Part No. COMP243. SAI Global Cert. GSCS20069 AS 2658:2008

READ AND SAVE THESE INSTRUCTIONS

16 Ultiflame Inset Electric Fire

2000W Ceramic Wall Heater with LED Display

'Safety, Signs and Signals' Results For JOE BLOGGS. Safety, Signs and Signals. Summary

WARNING FIRE OR EXPLOSION HAZARD.

Installation Instructions & Operating Manual IMPORTANT

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

Mobile Air Conditioner Instruction Manual Model TC-N9KM

OWNER'S MANUAL DIGITAL OIL FILLED RADIATOR HEATER WITH REMOTE CONTROL ITEM NO.: MG-MTOH907L. 120V ~ 60Hz 1500W

SG Burner Only

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Installation Requirements for Models:

CLASSIC WALL-MOUNTED PATIO HEATER

VERNON ELECTRIC FIREPLACE

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Wall Mountable Electric Fireplace with remote control

Renovator Range Firebox 900SS

Garage Ventilation Installation Instructions

Installation instructions. Built-in oven NZ AU. BI453 and BI603 models

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

OWNERS MANUAL. To Order Parts Call SPEED AIR MOVER

PELLET STOVES & INSERTS. PELLET STOVES & INSERTS

S6 Upright Vacuum Cleaner Instruction Manual

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

Renovator Range Firebox XL 1200SS

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

ATM Lighting sp. z o.o

NO VENTING REQUIRED 120V AC;

From Your Building Inspector

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

FIRE PREVENTION IN THE USE OF CUTTING OR WELDING PROCESSES

Fire Bowls and Fire Bowl Inserts (Automated Operation) Operating and Maintenance Instructions

INSTALLATION & USER INSTRUCTIONS

ASSEMBLY AND OPERATION MANUAL

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

INSTALLATION & USER INSTRUCTIONS

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

Transcription:

INSTALLATION MANUAL FLA 2 model E#4 L=1290 FLA 2 model E#4 REMOTE L=1290 A B C D x 3 x 3 x 1 E F G * x 1 Automatic fuel pump x 1 SERVICE KIT x 1 x 1 * only REMOTE Stainless steel Black [mm] [ ] [mm] [ ] H 196 7 11 /16 195 7 11 /16 H1 139 5 1 /2 139 5 1 /2 H2 3 1 /8 2 1 /16 L 1290 50 13 /16 1290 50 13 /16 L1 1090 42 15 /16 1090 42 15 /16 L2 100 3 15 /16 100 3 15 /16 D 255 10 1 /16 255 10 1 /16 D H H1 H2 L2 L1 L L2 Copyright 2017 Planika Sp. z o.o. www.planikafires.com i1269#01 18.05.2017 1

! Do not install the device in areas with a capacity of less than 225 m 3 / 7947 ft 3 (87 m 2 / 931 ft 2 with a height of 2.6 m / 8.53 ft). While installing the device according to the instruction manual local and national guidelines are to be observed. Place the device on a levelled surface. The cavity for the fireplace has to be designed with the use of a spirit level. It is not permitted to use the fireplace that is not placed in a housing. The cavity has to be designed according to the guidelines and dimensions in the instruction manual. If the cavity has different dimensions it has to be adjusted in such a way that it complies with the guidelines stated in the installation manual. Do not obstruct the ventilation slots and/or ventilators. Do not place any decorative elements on the device. Do not install the device in areas of large drafts of air, near fans, vents, etc. Do not place in areas where there might be a potentially explosive atmosphere of paint vapours, industrial dusts, etc. No flammable items should be placed in direct contact and within a radius of 1 m / 3.28 ft around the device. Do not place near curtains, net curtains, etc. Do not expose the device to weather conditions. The product is for internal use only. Do not expose the device to meteorological conditions. The device is for indoor use only. Do not place the device in close proximity to sources of humidity. It is obligatory to have a carbon-dioxide (CO 2) or dry chemical extinguisher placed nearby the device. Installation of the device must provide an easy removal of the device for service. The room in which the device will be installed must have efficient ventilation to ensure air exchange in the room at least once per hour. Do not start the device before a complete and proper installation. Do not fill the fuel container before placing the product into its final position. In case of mounting more than one unit in the room, the minimal cubature is the sum of cubatures required for each unit. Device must be kept out of reach of children, animals and unauthorized persons. Do not install the device on a mobile object (eg. caravan, yacht ). Copyright 2017 Planika Sp. z o.o. www.planikafires.com i1269#01 18.05.2017 2

INSTALLATION WARNING! If you have purchased the original steel casing for the device, please follow the instruction manual provided for the casing and skip the procedure described below. Place the device in a housing that is closely connected to the construction of the building. The elements of construction placed above the furnace must be made of non-flammable materials. Recess in which the fireplace will be placed must be sealed. If there is going to be a cover over the furnace, it must be made of non-flammable materials and the minimum distance from the furnace must be kept at no less than 40 cm / 15 ¾ in. Supply the housing with a loose cable min. 3x0,75 mm 2, with power supply 230 V, 50 Hz, to connect the device to the mains. It is not allowed to use a device before placing it into a prepared wall recess or other housing/cavity. Due to fire safety, it is forbidden to place any flammable materials within a 1 m (40 inches) radius from the fireplace. Also, Planika does not recommend to place any heat sensitive materials or devices within this radius as it can significantly limit the materials properties and longevity. Planika will not take any responsibility for the damage of any materials or devices being installed above the fireplace. Non-flammable materials Non-flammable materials min 1000 mm min 39 3 8 " min 1500 mm min 59 1 16 " min. 50 mm min. 1 15 16 " min. 50 mm min. 1 15 16 " min 1000 mm min 39 3 8 " min 1000 mm min 39 3 8 " Copyright 2017 Planika Sp. z o.o. www.planikafires.com i1269#01 18.05.2017 3

How to self-make the housing for the device. Make a cavity for the insert following the diagram below. Making the cavity make sure that the plane on which you are going to set the furnace inset is well levelled, as later it will not be possible to level the insert. The difference in level between the ends of the furnace must not exceed 2 mm. Poor levelling may cause abnormal operation of the device and, in extreme cases, it can cause leaks of the Fanola liquid and the danger of fire. Level the surface of the cavity. The deviation cannot exceed 2 mm (1/16 in) Cable min. 3 x 0,75mm 2, powered with 230 V, 50 Hz Then connect the supplied cable with a connection block at the end of the cord. Note that connection to the mains must be made by a qualified electrician. Previously connected burner should be placed in the cavity by the use of attached handles. Please make sure to remove the handles before starting the device and keep them for the lifetime of the product. If necessary, remove the device using these handles. Handle Connection to the mains must be made by a qualified electrician. Copyright 2017 Planika Sp. z o.o. www.planikafires.com i1269#01 18.05.2017 4

Installing the furnace glass shield. C D B C B C B Situations where the installation of glass shield protecting the furnace is necessary. Situations in which the montage of the glass slat covering the fireplace is forbidden. Copyright 2017 Planika Sp. z o.o. www.planikafires.com i1269#01 18.05.2017 5

WARNING! Make sure that the device has been correctly installed and read the attached instruction manual. You are not allowed to fill the fuel tank and start the device before having read the instruction manual. If in the future it is necessary to take the device out of the housing, wait until the fuel has burned-up completely and the display shows the housing. FUEL, disconnect the power supply and take the device out of Keep this instruction manual throughout the lifetime of the device. Copyright 2017 Planika Sp. z o.o. www.planikafires.com i1269#01 18.05.2017 6