MODEL 7000 SUCTION UNIT

Similar documents
Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

LoveGo. Portable oxygen concentrator Your Second Doctor. Table of contents. Lovego, let s go along with love. DO what you want to do

MaxiCompressor. evo. High Performance 50 PSI Compressor TH PLACE ADEL, IOWA 50003

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

SAVE THESE INSTRUCTIONS

SUCTION PUMPS CareLinc Home Medical Equipment and Supply, LLC SS170CE00101

USER MANUAL SAVE THESE INSTRUCTIONS

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

DEHUMIDIFIER. User Manual 50BT, 70BT

ASPIRE Laboratory Aspirator

WA A Aqua Sub Bottom-load Water Cooler

Table of Contents. English

Margo Moo TM and Digger Dog TM Steam Inhaler Guidebook

User Manual. 40 Tower Fan MODEL: WFTR40W

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

Cool Mist Ultrasonic Humidifier

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

P.N User Manual STAINLESS STEEL ELECTRIC KETTLE 5964/5965 Series MODELS

COOL MIST HUMIDIFIER USER MANUAL FOR MODEL: PAU1. Your Source for Home Comfort

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

PORTABLE DEHUMIDIFIER

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

HERCULES (110V) (220V) USER S MANUAL

16 Stand Fan with Remote Control Model No: FS3-40R-30

IMPORTANT SAFEGUARDS

18 INCHES, OSCILLATING STAND FAN

Outdoor Refrigerator USER S MANUAL

Portable Dehumidifier with Internal Pump

Manual Parts Washer. Operating Instructions & Warranty Information

CORDLESS GLASS ELECTRIC KETTLE WITH BONUS TEA INFUSER

Ui REFRIGERATOR SPEC SHEET

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

20 High Velocity Fan with 135 Tilt Head

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

P.N ELECTRIC KETTLE User Manual Series MODEL BVSTKT308

CONSTANT SUCTION UNIT

Portable Dehumidifier

English. Your Model Number is: HD1500 IMPORTANT

ELECTRIC KETTLE Model BVSBKT1703 Series. User Manual. QUESTIONS? COMMENTS? IN CANADA: P.N Rev.A

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

User Manual. Wine Cellar

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

ELECTRIC FIREPLACE OWNER S MANUAL

Instruction Cum User Manual For EUROLITE

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

Ultrasonic Humidifier

PORTABLE AIR CONDITIONER OWNER S MANUAL

HI Industrial Utility Heater HI Soleus Air International

User Manual. Juice Extractor MODEL: WJE2BSLA

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Outdoor/Commercial Refrigerator USER S MANUAL

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

IMpORTANT SAFETy INSTRUcTIONS

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

RJ11-17-TI CORDLESS GLASS ELECTRIC KETTLE. CUSTOMER SERVICE:

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

Owner s Manual Window Air Conditioner

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

- Oscillating Table Model Fan

INSTRUCTIONS FOR OPERATION AND CARE OF

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

User Manual ELECTRIC KETTLE Manual del Usuario HERVIDOR ELECTRICO. MODEL/MODELO BVSTKT7098 Series.

I N S T R U C T I O N S

PIPELESS WHIRLPOOL FOOT BATH OWNER S MANUAL. Model: FB2-S115

K Specifications. Max. Water Volume

IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

- 1 - Updated on 18 March, 2010

VersaBrew SINGLE SERVE COFFEE MAKER USER GUIDE

PORTABLE AIR CONDITIONER OWNER S MANUAL

Xaact Spot. Xaact Hot Spot

unprocess your food TRUGLIDE ELITE RAPID SKILLET Instruction manual & recipe guide MODEL DTGS14

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

MINI ELECTRIC CONVECTION HEATER

Instruction Manual. MODEL: FD1603 POWER SUPPLY: VAC, 60Hz or VAC, 50Hz POWER CONSUMPTION: 250W

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Model CWA200 Owner s Manual

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

INSTALLATION & OPERATING INSTRUCTIONS

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

NJ100 Series OWNER S GUIDE. Express Chop

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

R100 Oil-Less Refrigerant Recovery Unit

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

OWNE R S MA N UA L. Made in USA. September 2015

BASEBOARD MICATHERMIC HEATER

EP8020 STEAM GENERATOR IRON PROFESSIONAL TYPE IRONING SYSTEM WITH DETACHABLE WATER TANK FOR HOUSEHOLD USE ONLY

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

Transcription:

MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device. Check ALL parts for shipping damage. If shipping damage is noted, DO NOT use. Contact medical equipment provider for further instruction.

Index 1. Safety Information... 2 2. AC Power Source... 3 3. Electrical... 3 4. Introduction... 4 5. Illustration of Important Parts... 5 6. Set-Up... 8 7. How to Operate Your PROBASICS Suction Unit... 8 8. Cleaning Instructions... 11 9. Maintenance... 12 10. Troubleshooting... 14 11. Specifications/Classifications... 15 12. Warranty... 16 1

1. SAFETY INFORMATION When using electrical products, especially when children are present, basic safety precautions should always be followed. Read all instructions before using. Important information is highlighted by these terms: DANGER Urgent safety information for hazards that will cause serious injury or death. WARNING Important safety information for hazards that might cause serious injury. CAUTION Information for preventing damage to the product. Information to which you should pay special attention. READ ALL USER S MANUAL BEFORE USING. USER S MANUAL DANGER To reduce the risk of electrocution: 1. Do not use while bathing. 2. Do not place or store product where it can fall or be pulled into a tub or sink. 3. Do not place in or drop into water or other liquid. 4. Do not reach for a product that has fallen into water. Unplug immediately. WARNING To reduce the risk of burns, electrocution, fire or injury to persons: 1. Close supervision is necessary when this product is used by, on, or near children or invalids. 2. Use this product only for its intended use as described in this guide. 3. Never operate this product if: a. It has a damaged power cord or plug. b. It is not working properly. c. It has been dropped or damaged. d. It has been dropped into water. 4. Return the product to an authorized PROBASICS medical equipment service center for examination and repair. 5. Keep the power cord away from heated surfaces. 6. Never use while drowsy or asleep. 2

SPECIFIC WARNINGS TO REDUCE THE RISK OF ELECTRICAL SHOCK OR INJURY TO PERSONS, DO NOT DISASSEMBLE THIS UNIT. Disassembly or attempted repairs if accomplished incorrectly can create electrical shock hazard. Only qualified technicians should perform servicing of this suction unit. DANGER The PROBASICS Suction Unit is a vacuum suction device designed for the collection of nonflammable fluid materials in medical applications only. Improper use during medical applications can cause injury or death. For all medical applications: 1. All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority. 2. Some attachments or accessories may not fit the tubing supplied. All attachments or accessories should be checked prior to use to assure proper fit. 2. AC POWER SOURCE CAUTION The Model 7000 is used with a power supply allowing operation on AC voltage (115 VAC, 60 Hz). 3. ELECTRICAL Compressor If the overload protector shuts off the motor frequently, you may have a low voltage situation. Low voltage can also be suspected when: 1. The motor does not get up to full power or speed. 2. Other motor operated appliances fail to operate properly. Too many motor operated appliances on same circuit. The motor of this compressor has a thermal overload protector. If the motor overheat, the overload protector will shut off the motor. If this occurs, turn the ON/OFF switch to the OFF position and allow the motor to cool (approximately 5 minutes). Restart compressor. If the compressor fails to start, wait an additional 5 minutes before attempting to restart. If this fails, inspect the fuses on your suction unit. If the unit still does not restart, call your medical equipment provider immediately. 3

WARNING Proper operation of this product is necessary to avoid physical harm. Improper use can cause personal injury and/or tissue damage. This product should not be used unless the operator has been instructed by a physician or other qualified health care professional. 1. Familiarize yourself with this unit. 2. Place unit on table and push down hard so that suction feet hold unit firmly in place. 3. Before plugging power cord into electrical outlet, check if the ON/OFF switch is in the OFF position. Before attempting to start a cold unit, let the unit reach room temperature in a heated area. 4. INTRODUCTION Your PROBASICS Suction Unit is a professional medical suctioning device that produces a maximum vacuum of 520 mmhg. The unit is equipped with an 800 ml collection bottle and has been designed for convenient and reliable usages. Features: New anti-bacteria filter design helps contamination. High quality vacuum regulator and anti-vibration vacuum gauge setting. Oil-less, permanent lubrication. Collection bottle with overflow protection. Superior performance and high reliability for continuous operation design. Easy cleaning. Following the recommended operating and maintenance procedures outlined in this user s manual will maximize the life of this product. Refer to the diagrams on page 6. This unit complies with electromagnetic compatibility standards as defined in the attached declaration of conformity. 4

5. ILLUSTRATION IMPORTANT PARTS MODEL: 7000 Part # Description 1. 7001 Vacuum Adjust Knob 2. 7002 Vacuum Gauge 3. 7003 Fuse 4. 7004 Power Cord 5. 7005 Power Switch 6. 7006 Cushion Feet 7. 7007 Bacteria Filter 8. 7008 Connection Tubing 9. 7009 Patient Tubing Connector 10. 7010 Patient Tubing 11. 7011 800cc Collection Bottle 12. 7012 Collection Bottle Holder Figure 1 Figure 2 5

6. SET-UP 1. Connect either end of the connecting tubing (item# 8) to the top of collection bottle connector then connect the other end to the bacteria filter. 2. The patient tubing should be connected to collection bottle at the outlet labeled (patient). Please assure that all connections are secure and without leaks before using. 7. HOW TO OPERATE YOUR PROBASICS MODEL 7000 SUCTION UNIT 1. Before use, check the specification label on the side of the suction unit to ensure that the voltage and current indicated on the unit correspond with the voltage and current available. Make sure the power switch located on the side of the unit is in the Off position before connecting the unit to a power source. Figure 3.. Off position 2. Switch the power switch to I position (on), the unit start running. Figure 4 On position 6

3. Adjust the vacuum level from 0 to 520 mm Hg by turning the vacuum adjust knob (clockwise to increase vacuum and counter-clockwise to decrease vacuum). Referring to the vacuum gauge while setting the desired level of vacuum. To accurately read the gauge, block the patient end of the hose or cap off the collection bottle and allow the gauge to reach a stable vacuum reading. Vacuum Gauge Vacuum Adjust Knob Figure 5 Block Patient End of the Hose Cap Collection Bottle Figure 6 7

4. Place the patient tubing to the appropriate position of patient and start to suck sputum. 5. When the sputum reaches the safe full level of collection bottle (800 cc), the suctioning will stop sucking automatically (float shut-off). Safe Full Level Collection Bottle Figure 7 6. Switch the power switch to O position (off), shut off the suction motor. 7. Remove the sputum from collection bottle after the motor stops turning completely. (Please refer to the section CLEAN INSTRUCTIONS on page 9 for the directions of how to clean the collection bottle). 8. Turn on the unit and start to run the suction unit again. 1. If the unit sustains a severe drop, validity of the gauge must be checked. Inspect if the float shut-off is still functioning properly when the liquid in the collection bottle reaches the safe full level. 2. Always transport unit with vacuum adjust knob rotated fully clockwise in case unit is dropped. CAUTION 1. When automatic float shut-off is activated, contents of the collection bottles should be emptied. Further suctioning could cause damage to the vacuum pump. 2. Should fluid be aspirated back into the unit, send your suction to an authorized service center for a detailed inspection as the vacuum pump may have been damaged. 8

8. CLEANING INSTRUCTIONS Clean Collection Bottle: 1. Turn off the suction unit and allow vacuum to drop, then disconnect AC power source. 2. With the collection bottle still in the holder, remove the collection bottle lid. The bottle can now be taken out of the holder to be emptied. Holder Collection Bottle Figure 8 Collection Bottle Lid Collection bottle should be emptied after each use. 3. Collection bottle should be thoroughly cleaned after each use by one of the following three methods: a. Wash in a hot water/dishwashing detergent solution and rinse with clean, hot tap water. Then wash in one part vinegar to three parts hot water solution. Rinse with hot tap water and air dry. b. Wash with rubbing alcohol and air dry c. Wash with a commercial (bacterial-germicidal) disinfectant, follow disinfectant manufacturer's recommended instructions and dilution rates carefully. 9

Clean Suction Unit and Collection Bottle Lid: 1. Disconnect the suction unit from all external power sources. 2. Wipe the suction unit housing and collection bottle lid with a clean cloth and any commercial (bacterial-germicidal) disinfectant. CAUTION Do not submerge in water as this will result in severe damage to the vacuum pump. Clean Tubing: 1. Disconnect the tubing from the unit. 2. Tubing should be rinsed thoroughly after every use by running hot tap water through it followed by a solution of one part vinegar to three parts hot water. 3. Rinse with hot tap water and air dry. 4. Keep the outer surface of the tubing clean by wiping with a clean, damp cloth. WARNING The waste in collection bottle may cause respiratory infection which must be handled according to medical waste disposing regulation. Operator must wear gloves and medical class mask before cleaning the collection bottle, tubing and handle the wasting unit and/or accessories. 9. MAINTENANCE Inspect suction tubing and collection bottle for leaks, cracks, etc. before each use. DANGER Electric shock hazard Do not attempt to open or remove the suction cabinet. If a service is required, return your suction to an authorized Dealer. Opening or tampering with the unit will void warranty. 10

Bacteria Filter Change: 1. Bacteria filter should be replaced every two month. If overflow occurs, change the filter immediately. 2. Remove filter by disconnecting it from tubing connected to pressure adjusting valve and tubing connected to collection bottle lid assembly. 3. Replace with a new PROBASICS bacteria filter and connect to above two tubing. Additional filters can be purchased from an authorized dealer. Collection Bottle Lid Pressure Adjusting Valve Tubing Tubing Bacteria Filter Figure 9 Use only PROBASICS filters. Do not substitute any other material for this bacteria filter. Improper substitution may lead to contamination or poor performance; Fuse Change: 1. Use only the same type of fuse to replace the broken fuse. 2. Fuse specification: Miniature Glass Fuse 5x20mm WARNING When this unit or accessories reach the end of their useful lives (depends on using conditions), residues in collection bottle, tubing and filter may cause respiratory infection. Dump the wasting collection bottle, tubing and filter into a specific waste bin labeled with medical waste. 11

10. TROUBLESHOOTING Your PROBASICS Suction Unit contains no user-serviceable parts. If you believe your unit is not working properly, BEFORE YOU RETURN IT TO THE MEDICAL EQUIPMENT PROVIDER WHERE YOU PURCHASED IT OR TO PROBASICS, please take a few moments to check for these possible causes: PROBLEM Unit does not turn on Motor runs, no vacuum Low Vacuum ACTION 1. Check power source and connection 2. Ensure that the wall outlet is live 3. Check power cord is not damage 1. Verify tubing connection security 2. Check for leaks or tubing kinks 3. Ensure that float shut-off is not activated 4. Check for bottle leaks and cracks 1. Use vacuum adjust knob to increase vacuum level 2. Check system for leaks 3. Adjust vacuum adjust knob and release 12

11. SPECIFICATIONS / CLASSIFICATIONS Dimensions Weight. Maximum Vacuum Flow Range Sound Level (L) 375 x (W) 175 x (H) 250 mm (14.8 x 6.8 x 9.8 in) 5.5 kg (12.1 lb) 520 ± 3% mm Hg 40 LPM 58 dba Electrical Requirements 7000: AC 115 V 60Hz Power Consumption Bacteria Filter pore size Collection Bottle Capacity Operating Temperture Operating Humidity 7000: 70 watts 0.2 microns 800 ml (cc) 32 ~ 104 F (0 ~ 40 C) 95% RH Operating Atmospheric Pressure 10.2 ~15.4 psi ( 70 ~106 kpa ) Storage Temperture 14 ~ 158 F ( -10 ~ 70 C ) Storage Humidity 0 ~ 95% Storage Atmospheric Pressure 7.3 ~15.4 psi ( 50 ~106 kpa ) Fuse Specification Equipment Classifications Miniature Glass Fuse 5x20mm With respect to protection from electric shock Class I 13

12. WARRANTY Two years limited warranty The compressor portion of the PROBASICS Suction Unit is warranted to be free from defective workmanship and materials for a period of two years from date of purchase and six months on accessories. Any defective part(s) will be repaired or replaced at PROBASICS option if the unit has not been tampered with or used improperly during that period. Make certain that any malfunction is not due to inadequate cleaning or failure to follow the instructions. If repair is necessary, please contact you medical equipment dealer. This warranty does not cover providing a loaner unit, compensating for costs incurred in rental while said unit is under repair, or costs for labor incurred in repairing or replacing defective part(s). THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF THE EXPRESS LIMITED WARRANTY AND TO THE EXTENT PERMITTED BY LAW. ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED. THIS IS THE EXCLUSIVE REMEDY AND LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER ANY AND ALL WARRANTIES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE LIMITATION OR EXCLUSION OF CONSEQUENTIAL OR INCIDENTAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. For Service Call Your Authorized PROBASICS Medical Dealer: 15 South Main Street 2 nd Floor Marlboro, New Jersey 07746 www.pmiusa.biz 14