RQE Series Temperature Controllers

Similar documents
NQ Series Portable Chillers

SENTRA Series Water Unit

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

Aquatherm Series Temperature Controllers. Installation, Operation and Maintenance Manual

Circulating Water Temperature Controller

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Tankless On Demand Electric Water Heater

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Precise Temperature Control; Compact Footprint

Outstanding Performance; Application Flexibility

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

GUIDE SPECIFICATIONS AQUARIUS ii

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Installation, Operation and Maintenance Manual. RQ Series. Mold Temperature Control Units 0.75 to 7.5 hp and 0 to 24 kw

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

CX1 ProVector Explosion-Proof Heaters

Temptek Auxiliary Equipment

water to water heat pumps

LXG-300 Series. Models with LXG-300 Series Instruments

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

LQ AQ SQ. Air-cooled and water-cooled portable chillers

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Scroll Medical Air Compressor with Premium NFPA Control Panel

GUIDE SPECIFICATIONS AQUARIUS ii

CF1 ProVector Explosion-Proof Heaters

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

Static Pressure Control

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

"ESDDR" Series Electric Humidifier

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Enclosed Scroll Air Compressor System SES 3-5 HP

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Temperature Controllers

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Multistage Centrifugal Blowers

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Danfoss gas detection units

CLE SERIES Fluid heating for emergency eyewash stations

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

Central Chillers TS Series

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Danfoss gas detection units

Control and power circuit fusing to meet N.E.C.

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

Series 5000 Hydrazine Analyzer Model 60002

WZH Ground source heat pumps

TrilliumSeries. Condenser

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

Technical Manual. Level Alarm Unit CARLA & WIDS

Guide Specification Model CTG Automatic Transfer Switch

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

DESICCANT AIR DRYERS. BD + CD + CD series

VWR symphony CO 2 INCUBATORS

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

PURGE/PRESSURIZATION SYSTEM

Multistage Centrifugal Blowers

Hydronic & HVAC Control Systems

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

The water heater evolved. Hot water. Perfected.

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Triton Series High Efficiency Boiler

OACS Outdoor Air-Cooled Central Chillers

ULTRA-SAFE Explosion-proof Duct Heaters

Fixed Speed Rotary Screw Compressors UP6S Series hp (11-22 kw)

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

C44A/C44AW DISHWASHER

Proudly assembled in U.S.A

C1N & C2N SERIES Fluid heating for light industrial applications

Proudly assembled in U.S.A

Revitalize Building Mechanical Systems (4619)

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Fill Point, Level Gauges, and Control Range

Construction Electrical

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

wireless. web-based. worthy of the name RACO.

Altanium Temperature Controllers

VENTLESS DOOR-TYPE DISHWASHER

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

Better Design, Better Control, Better Systems.

BuildingName The Description of the Project P DOCUMENTS

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

Transcription:

RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature control units provide long lasting and dependable performance. Maximum Performance Carefully designed for high-flow mold cooling with precise temperature control our mold temperature control units ensure maximum performance to reduced cycle times. High-Flow Pumps Specifically designed to meet the rapid cooling requirements of injection mold cooling our unique high-flow energy-efficient pumps provide the best flow and pressure available in the industry. Long-Life Heaters Our heaters provide the best combination of performance and longevity with Incoloy sheathed electrical heater elements for better corrosion resistance than copper or stainless steel. Reliable Using the best available components and control software combined with our extensive experience in providing industrial cooling equipment ensures our units have outstanding reliability. Leak-Proof Pump/Heater Assembly Heavy-duty cast-iron pumps, heater tubes, and mixing tubes with tight-sealing O-ring seals eliminate threaded fittings that are a common cause of internal pressure losses and leaks. Long-Life Pump Seals/Internal Flushing System High-temperature pump seals, impellers with an integral flush system, and turbulence ribs inside the seal chamber extend seal life and are more effective and energy efficient than external seal flush lines. High-Performance Cooling Valves With both fast-acting solenoid valves for high-speed injection molding and high-capacity modulating valves for more demanding requirements, we can match the right valve to meet your needs. Control Panel Cooling Fan All units with heating capability include an electrical control panel fan to eliminate heat build-up to keep all electrical components to run cooler for peak performance and extended life. High-Quality 24 VDC Control-Circuit Power The 24-volt DC control-circuit power supply provides dependable and safe control circuit power and isolates the control circuit from static interference for stable and precise operation. Easy to Use We package our high-flow pumps, heaters, highperformance cooling valve, and other long-life components into a compact cabinet that minimizes floor space and provides easy-access. Tilted Front Panel Conveniently angled for optimal viewing, our front panel offers quick and easy monitoring and adjustment of the set point and other control functions. RQE Series Mold Temperature Controller Specification Form 7-219.4 Page 1 of 6

Tool-Free Cabinet The lift-off mechanical enclosure cover provides quick access to the pump and heater and the control panel has an easy-open front electrical control panel door for quick and easy component access. Front Facing Pressure Gauges Large easy-to-read supply and return pressure gauges located on the angled front of the unit provides easy monitoring of the mold circuit and unit performance. Internal Extended Power Cord An internal extended power cord from the control panel to the pump motor allows pump motor removal for pump seal and impeller access without the need to disconnect the pump motor wiring. Standard Controller Our control system provides an excellent combination of proven hardware with a powerful software control system for outstanding performance that is reliable and easy to use. Seal-Saver Program Stopping a pump without allowing the pump seal to cool down can lead to seal warping that shortens seal life, so our automatic seal saver program allows for pump seal cooling before the pump stops. Pump Running Hours Display Standard with every controller our pump running hour display provides a quick and easy way to monitor and record machine run time for planned maintenance. Temperature Deviation Warnings and Alarms The deviation warning provides a visual alert of a potential problem before a fault occurs. If the condition worsens, the alarm sounds and the unit stops to prevent equipment damage. Adjustable Deviation Alarm Time Delays Adjustable deviation alarms provide a way to program a start-up time delay to deactivate the alarms long enough for the process loop to stabilize without nuisance temperature alarms. Supply and Return Temperature Display The continuous display of the set point and supply temperatures and the ability to check the return temperature allow for complete monitoring of the process and unit operation. Alarm Horn and Silence Switch Standard on every unit, our alarm horn provides an audio and visual indication of an alarm condition and allows silencing of the alarm horn after acknowledgement of the alarm condition. Automatic Air Purge with 120 F Air Purge Cancel Designed to purge air from the mold at start-up our automatic air purge sequence deactivates when the mold circuit is above 120 F to avoid cooling of the mold during temporary power interruptions. RQE Series Mold Temperature Controller Specification Form 7-219.4 Page 2 of 6

Premium Controller This option provides more system monitoring and control for those applications where additional features are required. The premium controller also has an optional expansion port to allow for remote communications. Available Options Rotary non-fused disconnect switch C-UL508A industrial control panel construction Hand-held remote control panel Solid state relay heater controls Brazed plate heat exchangers 300 F maximum operating temperature Stacking rack Remote heat/cool contact Premium controller 4-20 ma supply output signal Premium controller ModBUS RTU communications Premium controller SPI communications Warranty 5 year control board parts 3 year entire unit parts 3 year labor Lifetime pump/heater casting Lifetime standard pump seal Lifetime $175 control board exchange More Premium Controller Features: Electrical phase error protects against loss of phase, phase reversal, and phase imbalance Heat error light alerts the operator when there is a heater contactor malfunction Dedicated quick access button to initiate the Seal- Saver sequence to extend seal life RQE Series Mold Temperature Controller Specification Form 7-219.4 Page 3 of 6

RQE Series Temperature Control Units Model Heating Capacity Pump Performance Unit FLA Ship Weight Model Heating Capacity Pump Performance Unit FLA Ship Weight kw hp gpm psi 460V (lbs) kw hp gpm psi 460V (lbs) RQE0008 0 ¾ 40 26 1.6 265 RQE2408 24 ¾ 40 26 31.7 265 RQE0010 0 1 50 28 2.0 270 RQE2410 24 1 50 28 32.1 270 RQE0020 0 2 75 30 3.0 280 RQE2420 24 2 75 30 33.1 280 RQE0030 0 3 85 32 4.1 340 RQE2430 24 3 85 32 34.2 340 RQE0050 0 5 100 46 6.4 345 RQE2450 24 5 100 46 36.5 345 RQE0075 0 7½ 125 54 9.0 350 RQE2475 24 7½ 125 54 39.1 350 RQE00TN 0 10 140 68 12.8 360 RQE24TN 24 10 140 68 42.9 360 RQE0908 9 ¾ 40 26 12.9 265 RQE3608 36 ¾ 40 26 46.8 265 RQE0910 9 1 50 28 13.3 270 RQE3610 36 1 50 28 47.2 270 RQE0920 9 2 75 30 14.3 280 RQE3620 36 2 75 30 48.2 280 RQE0930 9 3 85 32 15.4 340 RQE3630 36 3 85 32 49.3 340 RQE0950 9 5 100 46 17.7 345 RQE3650 36 5 100 46 51.6 345 RQE0975 9 7½ 125 54 20.3 350 RQE3675 36 7½ 125 54 54.2 350 RQE09TN 9 10 140 68 24.1 360 RQE36TN 36 10 140 68 58.0 360 RQE1208 12 ¾ 40 26 16.7 265 RQE4808 48 ¾ 40 26 61.9 295 RQE1210 12 1 50 28 17.1 270 RQE4810 48 1 50 28 62.3 300 RQE1220 12 2 75 30 18.1 280 RQE4820 48 2 75 30 63.3 310 RQE1230 12 3 85 32 19.2 340 RQE4830 48 3 85 32 64.4 370 RQE1250 12 5 100 46 21.5 345 RQE4850 48 5 100 46 66.7 375 RQE1275 12 7½ 125 54 24.1 350 RQE4875 48 7½ 125 54 69.3 380 RQE12TN 12 10 140 68 27.9 360 RQE48TN 48 10 140 68 73.1 390 RQE1808 18 ¾ 40 26 24.2 265 RQE1810 18 1 50 28 24.6 270 RQE1820 18 2 75 30 25.6 280 RQE1830 18 3 85 32 26.7 340 The standard operating range is 50 F to 250 F. RQE1850 18 5 100 46 29.0 345 RQE1875 18 7½ 125 54 31.6 350 RQE18TN 18 10 140 68 35.4 360 RQE Series Mold Temperature Controller Specification Form 7-219.4 Page 4 of 6

Manufacturer reserves the right to change specifications or design without notice or obligation. RQE Series Mold Temperature Controller Specification Form 7-219.4 Page 5 of 6

Notes RQE Series Mold Temperature Controller Specification Form 7-219.4 Page 6 of 6