PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

Similar documents
Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Lo-Carbon SELV Tempra

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

MANUAL INTELLIVENT CELSIUS

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Centrif Duo & Centrif Duo Plus

Lo-Carbon Quadra Centrifugal Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra SELV

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Silhouette Installation and Wiring Instructions

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

OPAL PANEL HEATERS. Home/Other Products/Obsolete Ranges

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Sentinel Kinetic MVHR RANGE

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

DUKA S7. Bathroom fan and Heat mover 8-11 User and Installation instructions. 2 Mounting illustrations 3 Parts. dukaventilation.dk

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Lo-Carbon T-series Window & Roof Models

CI/SfB (57.7) 1st edition

Lo-Carbon PoziDry Pro

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

Installation and Wiring Instructions

HR200WK Through the wall Heat Recovery Ventilator

SUPER T WALL FANS. Installation and Wiring Instructions

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

The UK s Leading Ventilation Company. Lo-Carbon Revive. 2nd Edition.

CI/SfB (57.7) 2nd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Installation and user manual

Warnings, Safety Information and Guidance

Alarm System SECURE AS 302

EFET 535. Installation Manual INT INT

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Diplomat Inverter/Diplomat Duo Inverter

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Sentinel. Kinetic Advance MVHR. Installation & Commissioning. Stock Ref. N Advance S Advance SX

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

5, SE GÅNGHESTER,

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Digital Electronic Thermostat With RF

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

Lo-Carbon Sentinel Kinetic Horizontal

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

aura-t TP536/EU ventilation systems

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

AUS. Devireg TM 535 Installation and user manual

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

aura-t TP536/GBR ventilation systems

Digital Electronic Thermostat With RF

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

Model: Available in : Sapphire Black and Glacier White. 1 Series

User instructions DHP-AT

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

GB User and maintenance manual

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3021H Non Programmable Thermostat. Table of Contents. Description. Initial Thermostat Power up

Ventilation and Hand Dryers

Programmable Electronic Thermostat

REA 105 Arc Protection Module. Operator s Manual

Model: RT310. Installation Manual

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Sentinel. Kinetic Advance MVHR. Installation & Commissioning. Stock Ref. N Advance S Advance SX

Model: RT310RF. Installation Manual

M2500 Engine Controller Installation Manual

Wet 2 Straight. 10,000 prize draw. Register online for S7300. EXTRA year guarantee FREE rewards gallery

USER MANUAL CEF AP28 CONTROL PANEL

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

User and maintenance manual

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

HOTLINE:

DOLKPS1KB Programming & Installation Manual

Original instructions. Thermoplus PL RU

Transcription:

PUREAIR SESE at hroom Fan wi t h O dour Sen se Tec h n ology Instruction Manual 101475 - Vent-Axia PureAir Sense F&W Manual.indd 1 A product by 12/02/2019 09:01:35

READ THIS FIRST! IMPORTAT! Please read these instructions carefully before use. The fan is designed for permanent installation and must be installed by an authorized electrician. According to the E 60335 Standard, the following must be taken into account: This product can be used by persons aged 8 years and over and by persons with reduced physical or mental ability or lack of experience and knowledge, if they have received guidance or been instructed on the use of the product in a safe manner and are aware of the risks. Children must not play with the product. Cleaning and maintenance must not be carried out by children without supervision. The fan channel length must not be less than 200mm. When mounting in wall or ceiling the external opening must always be protected against rain/snow with a hood/exterior grille. Functions Odour Sensor The Vent-Axia PureAir Sense fan is equipped with an odour sensor that increases the airflow when the air is poor. Adjustable Timer Triggered via light sensor. Possibility of a 2 minute delay, and selectable run-on time 15 or 30 minutes. The airflow can be adjusted from the control panel or via the app. Automatic Humidity Control System Fully automatic humidity control, which means the fan increases the airflow at increased humidity. The airflow can be adjusted from the control panel or via the app. Continuous or Intermittent Operation et the fan run continuously if you need basic ventilation in your home. The flow can be adjusted from the control panel or via the app. Airing Function If the fan has been inactive for 26 hours, it will run an airing program for 60 minutes. The airing function is not active when the fan is running continuously. The airflow can be adjusted from the control panel or via the app. App The Vent-Axia Connect App can be downloaded to Android and IOS devices. The app gives you access to a variety of settings and functions. See the Vent-Axia website for detailed information on all fan functions with and without the app. www.vent-axia.com 2 101475 - Vent-Axia PureAir Sense F&W Manual.indd 2 12/02/2019 09:01:35

Dimensions (mm) A A C D C D Reset Press the function button once. Press and hold the function button for at least 5 seconds. Speed EØ FØ EØ FØ Timer Function A C D EØ FØ 185 160 40 28.5 100 125 Settings Press the function icon and all adjustable/programmable symbols will light up. Then press any of the Timer, Humidity control, Continuous or ight/odour. This will only light up the selected function, which is then ready for adjustment. You can control speed/flow +/- is provided for certain functions. it lamps next to each symbol indicates the function is selected. See the Vent-Axia website for detailed information on all fan functions with and without the app: www.vent-axia.com Default Factory Settings Constant running low speed Airing function (every 26hr) Overrun timer Humidity function ight sensor Odour sensor O - 10l/s O - 15l/s 60min O - 15l/s 15min & 2min Delay O - 28l/s OFF - 15l/s O - 21l/s Technical Data Maximum airflow Min sound level Max pressure Power consumption Spigot depth Hole size Material Protection rating Insulation class Voltage frequency Certificates Mounting options luetooth E Humidity control Continuous ight/odour sensor 140 m³/h or 39l/s 19 d (A) 3 m 57 Pa 2-5 W 29 mm 105-130 mm AS plast IP44 X 100-240V AC 50-60 Hz DC6 Wall or ceiling -12dm EIRP (63µW), nominellt 2450MHz 3 101475 - Vent-Axia PureAir Sense F&W Manual.indd 3 12/02/2019 09:01:36

Electrical Wiring Electrical installation must be carried out by an authorised electrician. The fan is double insulated and should not be grounded. The fan is fitted with a multi-pole switch and does not require a pre-wired external switch. Installation Options The fan can be connected in three different ways depending on the desired function. The fan is connected with constant voltage supply 100-240 VAC 50/60 Hz, phase () and Zero (), see wiring diagram Time control with light switch, see wiring diagram 2. The fan is connected with constant voltage supply 100-240 VAC 50/60 Hz, phase () and Zero (). The control phase () is connected to activate the fan s time control, i.e. when the bathroom light comes on, there is power to the igniter wire. This option provides a delayed start of 2 minutes. The fan will run as long as the light is lit. When the light goes out, the fan will run for another 15/30 minutes. Time control with spring-loaded switch, see wiring diagram 3. The fan is connected with constant voltage supply 100-240 VAC 50/60 Hz, phase () and Zero (). The control phase () is connected to activate the fan s time control with spring-loaded switch. The fan runs for 15/30 minutes after the spring-loaded switch has been activated. Time control with spring-loaded switch, see wiring diagram 3. The fan is connected with constant voltage supply 100-240 VAC 50/60 Hz, phase () and Zero (). The control phase () is connected to activate the fan s time control with spring-loaded switch. The fan runs for 15/30 minutes after the spring-loaded switch has been activated. 1 2 3 100-240VAC 50/60Hz 4 101475 - Vent-Axia PureAir Sense F&W Manual.indd 4 12/02/2019 09:01:36

Mounting Options The fan is suitable for ceiling and wall mounting. A A C D C D EØ FØ EØ FØ A C D EØ FØ 185 160 40 28.5 100 125 Capacity Curve Maximum flow and available pressure 140 m³ / 39l/s / h_57 Pa with Ø 118mm (125) adapter. 60 55 50 45 40 Pressure Pa 35 30 25 2 1 2 Ø100 max speed Ø125 max speed 20 1 15 10 5 0 0 5 10 15 20 25 30 35 40 Volume Flow l/s 5 101475 - Vent-Axia PureAir Sense F&W Manual.indd 5 12/02/2019 09:01:37

Mounting 1 2 Ø98 Ø118 Ø98-100 Ø108 Ø127 Ø133 Ø118 Ø125 3 ~1-2 4 min 200 mm Min 200 mm 6 101475 - Vent-Axia PureAir Sense F&W Manual.indd 6 12/02/2019 09:01:38

5 124 6 40 20 20 40 13 7 A 124 92 46 56 112 A 40 40 8 Min 120mm 9 1(x4) 4(x1) Min 80mm 2(x4) 3(x4) Installation 10 11 7 101475 - Vent-Axia PureAir Sense F&W Manual.indd 7 12/02/2019 09:01:39

12 13 14 1 2 3 100-240VAC 50/60Hz 15 16 8 101475 - Vent-Axia PureAir Sense F&W Manual.indd 8 12/02/2019 09:01:40

17 18 19 On / 1 Cleaning & Maintenance The Vent-Axia PureAir Sense is designed to work efficiently for many years. For the fan to work correctly, it must be cleaned regularly. The cleaning interval is determined by how long the fan is operated and the air quality. Clean the fan at least twice/year or as necessary. When cleaning, disconnect the power to the fan by pressing the multi-pole switch upwards to the O-OFF position. 1 Off / 0 2 3 4 5 9 101475 - Vent-Axia PureAir Sense F&W Manual.indd 9 12/02/2019 09:01:41

Mounting of Magnetic Front Cover (accessory) 1 2 3 Warranty We provide a 7-year warranty against manufacturing defects. For the warranty to be valid, proof of purchase is required and the fan: must be assembled and installed in accordance with the installation guide in this manual must have been maintained according to the maintenance instructions in this manual must be mounted in a normal residential environment must be connected to a voltage of 100-240VAC 50/60Hz has not been exposed to lightning or abnormal power surges has not been subjected to tampering has been installed so that water cannot spray/flush the fan must not have been installed in an environment where the temperature has exceeded 50 Celsius Product complaints shall be made to the point of purchase. Recycling The product is labelled with the WEEE symbol indicating that it must not be disposed of in the household waste, but should be recycled at the appropriate place in each municipality. 10 101475 - Vent-Axia PureAir Sense F&W Manual.indd 10 12/02/2019 09:01:42

Quick Guide Function indication is given with different colours. The function symbol is lit depending on the active function: To access the functions that can be programmed: First press the function icon. lue light The fan is running due to increased humidity. Flashing blue light The fan is running because it has detected that it can lower the humidity in the room. Select time: Activate/deactivate delayed start: Increase/decrease airflow: One press at a time Hold for 2 secs. The lamps flash 3 times Press the +/- buttons 15 min 30 min 15 min 30 min Humidity Control All programmable function symbols light up. o light The fan is off or activated for continuous operation. Timer Timer Humidity Control Continuous Odour/ight Operation Sensor To activate the desired function, press any of the four symbols and then follow the instructions to the right. The process is then ended by pressing the function icon twice. The lights will show which selection option you are on: Press once to scroll to the next option. Keep scrolling until you get to the option you want. Increase/decrease airflow during humidity-activated operation: Hold for 2 secs Press the +/- buttons Fast Fast ormal ormal Slow Slow Deactive Deactive Continuous Operation Activate: Deactivate: Increase/decrease airflow: Press until the lamp comes on Press until the lamp goes off Press the +/- buttons ight and Odour Sensor Green light Indications: Activate/deactivate: Increase/decrease airflow: The air quality sensor has activated the fan. The corresponding lamp lights up Press repeatedly until the lamp goes on or off Select the Timer speed function, which is common for the flow with the lights sensor ight Sensor ight Sensor Air quality function has same speed as humidity function Odour Sensor Press the +/- buttons Activate 1 touch Touch and hold for 5 sec Purple light The fan has been started by the airing function. Yellow light The fan is running on the timer. Flashing yellow The delay timer counts down, faster flashes towards the end. Odour Sensor ight Sensor & Odour Sensor Inactive Reset (to factory settings) 11 101475 - Vent-Axia PureAir Sense F&W Manual.indd 11 12/02/2019 09:01:47

Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. SAES EQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHICA SUPPORT: Tel: 0344 8560594 Fax: 01293 532814 Accessories available: (purchased separately) 1. Wall Mounting ack Plate Stock Ref. 406762 2. Internal Wall Kit - White Stock Ref. 474779 with ackdraught Shutter 1. 2. Copyright Vent-Axia We accept no liability for printing errors and reserve the right to make changes to materials and designs. 0119 479563A 008752 101475 - Vent-Axia PureAir Sense F&W Manual.indd 12 12/02/2019 09:01:49