CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

Similar documents
Cleanroom Air Showers

CLEAN AIR SYSTEM.

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

LAMINAR FLOW FOR ALL YOUR NEEDS

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

HALCO PRODUCTS COMPANY

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Clean Bench Animal Transfer Stations

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Innovation in air purification unmatched air quality

AIR SHOWERS CAP701 SERIES

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Air Shower TECHNICAL DATA

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

SOLUTIONS TO STATIC PROBLEMS

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms

LABORATORY CABINETS 103

PRODUCT OVERVIEW. or other secondary operations using a high velocity, high impact air stream.

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Biological Safety Cabinet

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

INCREASE YOUR LAB EFFICIENCY

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

laboratory & sterilization technology

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Air Micron, a 5 year old venture, in the field of integrated micro contamination control, specializes in:

DOWNDRAFT BENCH SERIES

L a b o r a t o r y E q u i p m e n t C a t a l o g

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Laminar Flow Hoods and Booths

Our Honesty. Our Expertise. Your Safety.

Laminar Flow Cabinets eco air V

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

XPert Balance and Bulk Powder Enclosures

systemräume Gaining space for man and technology CLEAN ROOMS AND CONTROLLED ZONES

Our energy efficient experts and engineers have made ground breaking innovations in this field.

How to comply with CDC Guidelines

Precision Containment for All Applications

5.0 Installation Instructions

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and


CREATING A CLEANER ENVIRONMENT EAZIFLO FUME CAPTURE SYSTEM

BioSafety Cabinet- Class 100

Safe Operating Procedure (Revised 2/10)

Gelaire BH-EN and UltraSafe cabinets

KIC Air Curtains. Technical Guide

ENVAIR lab CO2 Incubator

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Series 650 Read ALL INSTRUCTIONS carefully.

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

INCREASE YOUR LAB EFFICIENCY

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

PROTECTION PRODUCT. Series CleanLamin AirFlow. Cabinets Series CLF, DLF and DLF/PCR


PRODUCT CATALOG HORIZONTAL AUTOCLAVE.

IVF/ART Series Laminar Flow Cabinets

MODEL NUMBER NOMENCLATURE

INCREASE YOUR LAB EFFICIENCY

Equipment guide for local exhaust ventilation (LEV)

Customized Industrial Products

Plant Growth Chamber MPGR14

Biological Safety Cabinets. Biological Safety Cabinets

Standard Features. Performance/Capacities

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

INCREASE YOUR LAB EFFICIENCY

GLOBAL FINISHING SOLUTIONS

Centeral Station Air Handling Unit

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Microbiological Safety Cabinets

Benchtop CO 2 Incubator. the Oasis 6400 series

Industrial Air Purification Guide

Pharmaceutical Facility Design

DEKO Washer-disinfector WASHROOM SYSTEMS

Class II ECO Generation 8 Microbiological Safety Cabinet

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

ZERO Economy Blast Cabinets

Vertical Laboratory Autoclave A series:

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

Indirect Gas-Fired Make-Up Air

Double Skin Air Handling Units

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

92831 TEL: (714) FAX:

Transcription:

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL CLEAN BOOTH JAPAN AIR FILTER

CLEAN ROOM EQUIPMENT SERIES Summary Clean Room Equipment are used for a wide range of applications, starting from controlling fine particles or microbial particulars such as fungi and bacteria, or to maintain the pressure of a room, or to control contamination, and many more. These equipment are required for clean rooms in various field ranging from precision, semiconductor, pharmaceutical and Food & Beverage plants to hospitals and laboratories. As wide as the range of equipment are, we are able to cater for the needs of our clients.

Product Category Product Name Pressure Relief Damper Product Introduction Self contained chambers Minimizes particulate matter entering or exiting the clean space High velocity HEPA-filtered air jets Maintains the internal positive pressure of a clean room Adjustable pressure difference Simple and reliable mechanical design Page 4 5 Effective solution to transfer materials into controlled environment without fear of possible air borne Pass Box contamination or actual personnel movement Interlocking door mechanism 6 Maximum chemical resistance and enhanced durability Pass Though Clean Bench Vertical Down Flow Type Clean Bench Horizontal Down Flow Type Clean Booth Effective solution to transfer materials on carts into controlled environment without fear of possible air borne contamination or actual personnel movement Interlocking door mechanism Maximum chemical resistance and enhanced durability Effective way to remove surface-deposited particles on carts as you transfer them into the clean room ( type only) Standalone adjustable clean filtered air supply Laminar air flow Ease of assembly and disassembly Standalone adjustable clean filtered air supply Laminar air flow Ease of assembly and disassembly Simple clean room but install most conveniently & quickly Different clean rade & space assortment, according to application Can install in normal grade clean room to save cost 7 8 9 10 Model Configuration 3

Standard Type Self contained chambers Minimizes particulate matter entering or exiting the clean space High velocity HEPA-filtered air jets Air Nozzle Outer Dimension Inner Dimension Nozzles (Qty) Person per Cycle (Qty) SIngle Side Double Side Double Side + Top 1300x1000x2040 1300x2000x2040 1300x3000x2040 1500x1000x2040 1500x2000x2040 1500x3000x2040 1500x1000x2200 1500x2000x2200 1500x3000x2200 800x900x1910 800x1900x1910 800x2900x1910 800x900x1910 800x1900x1910 800x2900x1910 800x900x1910 800x1900x1910 800x2900x1910 6 12 18 12 24 36 14 28 42 1-2 2-4 3-6 1-2 2-4 3-6 1-2 2-4 3-6 Filter: Pre-Filter and HEPA Filter, Power Supply: AC 230 V/1ph/50 Hz. Showering Period: 10-99 seconds (adjustable) Please Discuss for other special & custom sizes & design. Photo Sensor Automatic Door Movement ULPA Filter Stainless Steel Construction Leveling Floor Surface UV Lights Emergency Stop Electronic Door Strikert PLC Control System Door Opening Direction Standard Design Electronics Inter-locking Indication Lights (Power, Operating) HEPA Filter Fan Blower Single Door Opening Fluorescent Lighting SS Nozzles Infrared IR Sensor Pre-Filter SS Floor Panel Fluorescent Lighting Single Door Opening Electronics Inter-locking A B C D E Please discuss for sliding doors & other special & custom design like tunnel system, special walk way type, cargo use type, etc. Operating Sequences Clean Room when entering Clean Room when entering No Shower Direct Exit Clean Room when entering when Exit Light Indicators HEPA Filter Fan Blower SS Nozzles Infrared IR Sensor Pre-Filter SS Floor Panel One-Way Two-Way One-Way Two-Way 4

PRESSURE RELIEF DAMPER CLEAN ROOM EQUIPMENT Standard Type Pressure Relief Damper Maintains the internal positive pressure of a clean room Adjustable pressure difference Simple and reliable mechanical design Pressure Relief Damper Pressure Relief Damper Air Flow Rate (m 3 /min) Damper Opening Area LxH (mm) Construction Balancer Applicable Wall Thickness 4.7 9.9 15.0 19.8 200x150 400x150 600x150 600x200 Electro Galvanized Steel with Powder Baked Movable Fine Adjustable Balancer Minimum 2 Please discuss for other special & custom sizes & design. Stainless Steel Construction Pressure Gauge Standard Design L Wall Removable louver face Locking Screw Weight H 5

PASS BOX CLEAN ROOM EQUIPMENT Standard Type Pass Box Pass Box Pass Box Effective solution to transfer materials into controlled environment without fear of possible air borne contamination or actual personnel movement Interlocking door mechanism Maximum chemical resistance and enhanced durability Type Outer Dimension Inner Dimension Contruction Internal Stucture Construction Door Mechanism Standard With 585x490x480 685x580x590 785x680x690 985x880x890 780x480x1350 880x580x1450 980x680x1550 1180x880x1750 400x400x400 500x500x500 600x600x600 800x800x800 400x400x400 500x500x500 600x600x600 800x800x800 Electro Galvanized Steel with Powder Baked Stainless Steel Mechanical interlocking mechanism prevents both doors from opening at the same time Please discuss for other special & custom sizes & design. Electronics Locking Device (Electromagnetic) HEPA / ULPA Filtration Systems for Laminar Flow/ UV Lights / Normal Fluorescence Lights Full Stainless Steel Body System Emergency Door Electronics Devices (Phone-Access, Alarm) Mechanical Devices (Pressure Gauge) Indicator Lights Standard Pass Box Design SS Nozzles Hinges Lever Hinges Lever Lever Knob Glass Indicators Lever Knob Glass Pressure Gauge ON/OFF Switch Standard Type With Type 6

PASS-THOUGH CLEAN ROOM EQUIPMENT Standard Type Pass-Though Pass-Though Pass-Though Effective solution to transfer materials on carts into controlled environment without fear of possible air borne contamination or actual personnel movement Interlocking door mechanism Maximum chemical resistance and enhanced durability Effective way to remove surface-deposited particles on carts as you transfer them into the clean room ( type only) Dimension Dimension based on customer s requirement Contruction Electro Galvanized Steel with Powder Baked Please discuss for other special & custom sizes & design. Door Mechanism Mechanical interlocking mechanism prevents both doors from opening at the same time Electronics Locking Device (Electromagnetic) HEPA / ULPA Filtration Systems for Laminar Flow/ UV Lights / Normal Fluorescence Lights Full Stainless Steel Body System Emergency Door Electronics Devices (Phone-Access, Alarm) Mechanical Devices (Pressure Gauge) Indicator Lights Standard Pass-Through Design SS Nozzles Lever Hinges Indicators ON/OFF Switch Glass Lever Knob With Type Without type available too. 7

CLEAN BENCH CLEAN ROOM EQUIPMENT Standard Type Clean Bench Clean Bench Standalone adjustable filtered clean air supply Laminar air flow Ease of assembly and disassembly Clean Bench Vertical Down Flow Type Outer Dimension 680x680x1800 1280x680x1800 1280x1010x1800 1280x1280x1800 Power Source: AC 230 V/1ph/50 Hz. Please discuss for other special & custom sizes & design. Inner Dimension 600x600x680 1200x600x680 1200x930x680 1200x1200x680 Stainless Steel, Static Coated Steed Plate Frame ULPA Filter Roller Base Type Pressure Gauge Pressure Alert/Alarm Movable Bench Top Perforated Bench Top Vinyl Curtain Standard Design VSC FFU ON/OFF Indicators FAN HEPA Bench Top 8

CLEAN BENCH CLEAN ROOM EQUIPMENT Standard Type Clean Bench Clean Bench Standalone adjustable filtered clean air supply Laminar air flow Ease of assembly and disassembly Clean Bench Horizontal Cross Flow Type Outer Dimension Inner Dimension 840x900x1620 840x650x720 1300x900x1620 1300x650x720 1600x900x1620 1600x650x720 1900x900x1620 1900x650x720 Power Source: AC 230 V/1ph/50 Hz. Please discuss for other special & custom sizes & design. Stainless Steel, Static Coated Steed Plate Frame ULPA Filter Roller Base Type Pressure Gauge Pressure Alert/Alarm Movable Bench Top Perforated Bench Top Standard Design Transparent acryl plate W 150 550 100 Light fitting Light diffuser Air blow-out surface HEPA filter Bench Top Switch Panel Pre-filter H (Outer) 730 H (Inner) 30 100 Blower Power supply (AC230V 1 ph 50hz) Adjuster Castor Wheel 9

CLEAN BOOTH CLEAN ROOM EQUIPMENT Standard Type Clean Booth Clean Booth Simple clean room but install most conveniently & quickly Different clean rade & space assortment, according to application Can install in normal grade clean room to save cost Clean Booth Outer Dimension WxDxH (mm) Inner Dimension WxDxH (mm) Frame Contruction Wall Contruction 2700x1800x2550 2700x1800x2200 Electro Galvanized Steel with Powder Baked Vinyl Curtain Filter: JAF Pre-Filter and HEPA Filter, Power Supply: AC 230 V/1ph/50 Hz. Number of FFU & Air Change are depending on customer's class requirement. Please Discuss for other special & custom sizes & design. Soft Wall (See through Acrylic, Antistatic Vinyl curtain) Strip Doors Stainless Steel Swivel Casters Standard Design 2700 1800 Fan filter unit 2550 2200 350 Switch Vinyl Curtain Weight Chain Power Supply Exit/Entrance Point 10

NOTE

BUSINESS LINE Air-conditioning Sector Environmental Sector Plant Sector Electromechanical Sector Air-cond air filter Dry/wet type precipitator Gas turbine, clean air intake Electrical, electronic measurement Air-cond, ventilation silencer equipment application control system Ihitchen exhaust/odour hood filter Agricultural drainage/wastewater Clean room for various type of plant Freezer, Heater, Air-cond raw Clean room/bio-cleanroom equipment sludge treatment Clean room for nuclear power plant material Equipment related product maintenance /equipment Laser marker Humidifier Deodorizing equipment Silencer equipment/setup Sterilization equipment Cold intake devices Air-cond equipment maintenance Exhaust duct work Sound proof work Air-cond equipment work Lot. 4, Jalan Halba 16/16, Section 16, Shah Alam Estate, 40200 Shah Alam, Selangor, Malaysia. Tel +6012 973 9979 Fax +603 5510 0266 car/cre/042013