EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

Similar documents
RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

EC L2. and humidity sensors. All units are supplied tested and ready to install.

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

RIS V EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. AHU med varmegenvinding AIR HANDLING UNITS

RIS V. AHU with heat recovery. exchanger. AHU is used for ventilation of houses and other heated areas. Stouch and TPC remote control devices.

AIR HANDLING UNITS ver B

RIS H NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

RIRS V. AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

CHIME-FLEX SA. Centrales compactes RECUPERATEUR A PLAQUES VERSION VERTICALE

RIS H EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

RIS H EC NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

RIS P RIS P EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit wärmerückgewinnung

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

RIS P RIS P EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

KOMFORT EC DB Suspended heat recovery air handling units

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

air handling units Issue 2016 ver. A

EKA / EKA NV / EKA NI / EKA NIS

Ventilationsaggregater med krydsvarmeveksler

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

RIRS H. AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła. Вентиляционные агрегаты с рекуперацией тепла

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

We simplify construction

RIRS V EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

VEX100 series Air handling units with cross-flow heat exchanger

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

RIS H EKO NEW! AHU with heat recovery. Rekuperatoriniai įrenginiai. Centrale wentylacyjne z odzyskiem ciepła

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

We simplify construction

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

VERSO Air Handling Units

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Systemair product news - Fans NEWS

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

Series VENTS VUT R WH ЕС

We simplify construction

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

UNITES TERMINALES ET MINI CTA FIDJI

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

BARKELL AIR HANDLING UNITS

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Air heater/cooler in combination with ground source heat pump

Swegon CASA. duct coils for heating. the supply air

SMART WAY TO HANDLE THE AIR

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

2013 innovation. Room-by-room demand controlled heat recovery ventilation

TopMaster Air Handling unit. Technical data

Air handling units Compair. Technical Catalogue

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

VERSO Air Handling Units

GLOBAL RX. Ventilation unit with rotary heat exchanger

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Topvex SR03, SR04, SR06 Compact Air Handling Unit

SILVERTOP RANGE ENERGY RECOVERY

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

CONTENT: VEX308 Decentralised ventilation VEX308

OXeN. Ductless ventilation with heat recovery.

VENTILATION. Effective heat exchange and fresh air ventilation

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Gas heaters and convectors ROBUR

Transcription:

EC A1/L2 Application Ventilation of houses, offices or other heated premises (classrooms, apartments, conference rooms, etc.) Description 3. is a range of heat recovery units with high-efficiency counter-flow heat exchangers and low height. The units are designed for mounting under ceilings in order to save space. There are 5 sizes (airflow interval 42-25 m 3 /h) with separate heaters available for different climate zones. 3. units have high overall energy savings due to the highly efficient heat recovery (up to 9%), quiet and economical EC fans, effective low-pressure-drop filters, % motorized bypass dampers (for the 19 and 25 versions) and top-level of air tightness. Energy efficiency ensures full thermal comfort for passive houses, without an additional pre-heater at temperatures above -5 C. All the 3. units are fully equipped with automatic controls. Optional external sensors for CO 2 and humidity and the event planning feature will help to control automatically your climate (demand-level control). 3. units are service-friendly and are easy to mount. Filter pollution may be identified by timers or contamination controls (RIS 1-25 P EKO 3.). All units are supplied tested and ready to install. Remote control Features Construction Three remote control options are available: 1. Flex, Stouch or Ptouch remote controllers. 2. Building management system connections. 3. Remote control via PC MB-Gateway. Ideal for ceiling installations. Ready for Passive House technology: high efficiency. Easy and quick mounting. Water/electrical heating options. Fully integrated plug-and-play control system. Frameless construction from double-skinned panels. Acoustic and thermal wall insulation: RIS 4 25 P EKO 3. 3/5 mm. RIS 4-7 P EKO 3. powder-coated white housing RAL 916; RIS 1 25 P EKO 3. powder-coated grey housing RAL 74. Integrated electrical heater or optional duct-based water heater/cooler. Low-pressure-drop filters: F7/M5. Hinged door with locks grants easy access to internal components. Separate compartment on the side of the unit grants quick access to the control board (plug-and-play). Stainless steel condensate tray. Fitted with mounting brackets. Integrated anti-frost pressure switch (RIS 1-25 P EKO 3.). RIS 4 P E.9 EKO 3. Equipped with new control board AHU with EC motors and efficient heat exchanger Electrical heater power in kw Heater type (E - integrated electrical heater; W - prepared for water heater) Housing type (V - vertical, H - horizontal, P - ceiling) AHU size according to maximum airflow range m 3 /h AHU with plate heat exchanger 64

RIS 4P EKO - RIS 7P EKO 3. RIS 1P EKO - RIS 25P EKO 3. H4 H4 H H1 F H H1 F G H2 W W1 H3 H2 W W1 H3 D W2 W2 Dimensions [mm] Unit W W1 W2 H H1 H2 H3 H4 F ød G D RIS 4PE/PW EKO 3. 13 1361 65 768 67 158 33 98 31 - - RIS 7PE/PW EKO 3. 138 1461 695 169 97 16 35 99 4 25 - - RIS 1PE/PW EKO 3. 155 1655 78 1497 1397 172 39 52-5 25 RIS 19PE/PW EKO 3. 175 187 71 1955 185 194 399 15 6-7 3 RIS 25PE/PW EKO 3. 185 197 72 255 195 244 499 15 6-7 4 Unit Flex Stouch Ptouch MB- Gateway S-1141 S-RC2-F2 S-KFF-U SSB Heating SSB Cooling SP Supply Optional accessories SP Exhaust SVS SSK SKS RMG VVP/ VXP SKG AKS AP AVS AVA EKA NV PH RIS 4PE EKO 3. + + - 81 CM23-1-F-L CM23-1-F-L - - - - - RIS 4PW EKO 3. + + 61 81 TF23 CM23-1-F-L - - + + - RIS 7PE EKO 3. + + - 81 CM23-1-F-L CM23-1-F-L - - - - 25 25 - RIS 7PW EKO 3. + + 61 81 TF23 CM23-1-F-L - - + + 25 25 - EKS NV PH RIS 1PE EKO 3. + + - - LM23A-TP LM23A-TP - 5x25 - - - - 5x25 RIS 1PW EKO 3. + + 61 - NF23A LM23A-TP 5x25 5x25 + + - - 5x25 RIS 19PE EKO 3. + + - - LM23A-TP LM23A-TP - 7x4* - - - - 7x4* RIS 19PW EKO 3. + + 61 - NF23A LM23A-TP 7x4* 7x4* + + - - 7x4* RIS 25PE EKO 3. + + - - LM23A-TP LM23A-TP - 7x4 - - - - 7x4 RIS 25PW EKO 3. + + 61 - NF23A LM23A-TP 7x4 7x4 + + - - 7x4 *necessary to order flange adapter STP 7x4-7x3 Accessories Network Module Remote controller Control panel Remote controller Pressure transmitter CO2 sensor MB- Gateway p. 178 Ptouch p. 175 FLEX p. 177 Stouch p. 176 S-1141 p. 179 S-RC2-F2 p. 18 Humidity sensor Thermic water valve actuator Actuator for dampers Water heater coil Damper for rectangular duct Rectangular duct silencer Shut-off damper Circular duct silencer S-KFF-U p. 181 SSB p. 195 SP p. 21 SVS p. 19 SSK p. 213 SKS p. 215 SKG p. 212 AKS p. 216 Mounting clamps Heating coil Circular duct water cooler Electrical duct pre-heater Electrical duct pre-heater Mixing point 2 and 3 way valves Flange adapter AP p. 219 AVS EKS EKA p. 185 AVA p. 193 NV PH p. 23 NV PH p.21 RMG p. 196 VVP/VXP p. 197 STP p. 22 65

RIS 4PE EKO 3. RIS 4PE EKO 3. 5% 5% Extract air Outdoor air GAGRIS1747_17A 4PE.9 EKO 3. Integrated electrical heater GAGRIS1746_17A 4PE 1.6 EKO 3. Integrated electrical heater GAGRIS1692_16A 4PE 3. EKO 3. Integrated electrical heater.9 EKO 3. 1.6 EKO 3. 3. EKO 3. Electrical heater phase/voltage [5Hz/VAC] ~1, 23 ~1, 23 ~1, 23 [kw],9 1,6 3, EC fans phase/voltage [5Hz/VAC] ~1, 23 exhaust power/current [kw/a],85/,73 fan speed [min -1 ] 3 supply power/current [kw/a],85/,73 fan speed [min -1 ] 3 Max power consumption [kw/a] 1,7/5,5 1,77/8,5 3,17/14,5 Housing insulation, mineral wool [mm] 3 Colour RAL white 916 Weight (net, without packing) [kg] 74 Comply with ERP 216; 218 * Calculated according EN 13141-7. (balanced mass flow) EN 13141-7: RIS 4PE EKO 3. LWA, Supply 67 54 59 64 58 57 54 47 Extract 58 48 5 53 51 48 46 41 Surrounding 51 4 43 46 45 4 39 36 Measured at 395 m 3 /h, Pa 66

RIS 4PW EKO 3. 5% 5% RIS 4PW EKO 3. Extract air Outdoor air GAGRIS1748_19A 4PW EKO 3. Optional water heater 4PW EKO 3. Water heater (optional) AVS Fans phase/voltage [5Hz/VAC] ~1, 23 exhaust power/current [kw/a],85/,73 fan speed [min -1 ] 3 supply power/current [kw/a],85/,73 fan speed [min -1 ] 3 Max power consumption [kw/a],17/1,5 Housing insulation, mineral wool [mm] 3 Colour RAL white 916 Weight (net, without packing) [kg] 73 Comply with ERP 216; 218 * Calculated according EN 13141-7. (balanced mass flow) EN 13141-7: RIS 4PW EKO 3. LWA, Supply 67 54 59 64 58 57 54 47 Extract 58 48 5 53 51 48 46 41 Surrounding 51 4 43 46 45 4 39 36 Measured at 395 m 3 /h, Pa 67

RIS 7PE EKO 3. 18 16 14 12 8 6 4 2 18 16 14 12 8 6 4 2 Extract air Outdoor air GAGRIS1737_8A 7PE 1.2 EKO 3. Integrated electrical heater GAGRIS1736_7A 7PE 3. EKO 3. Integrated electrical heater GAGRIS1693_5B 7PE 4.5 EKO 3. Integrated electrical heater 1.2 EKO 3. 3. EKO 3. 4.5 EKO 3. Electrical heater phase/voltage [5Hz/VAC] ~1, 23 ~1, 23 ~3, 4 [kw] 1,2 3, 4,5 EC fans phase/voltage [5Hz/VAC] ~1, 23 exhaust power/current [kw/a],168/1,4 fan speed [min -1 ] 323 RIS 7PE EKO 3. supply power/current [kw/a],168/1,4 fan speed [min -1 ] 323 Max power consumption [kw/a] 1,54/8,34 3,34/15,84 4,84/9,3 Housing insulation, mineral wool [mm] 3 Colour RAL white 916 Weight (net, without packing) [kg] 13,5 14 14,5 Comply with ERP 216;218 * Calculated according EN 13141-7. (balanced mass flow) EN 13141-7: RIS 7PE EKO 3. LWA, Supply 75 64 66 68 7 66 6 59 Extract 62 53 55 57 56 52 49 45 Surrounding 56 45 47 5 5 47 43 42 Measured at 7 m 3 /h, Pa 68

RIS 7PW EKO 3. 18 16 14 12 8 6 4 2 18 16 14 12 8 6 4 2 RIS 7PW EKO 3. Extract air Outdoor air GAGRIS1738_9A 7PW EKO 3. Optional water heater 7PW EKO 3. Water heater (optional) AVS 25 Fans phase/voltage [5Hz/VAC] ~1,23 exhaust power/current [kw/a],168/1,4 fan speed [min -1 ] 323 supply power/current [kw/a],168/1,4 fan speed [min -1 ] 323 Max power consumption [kw/a],34/2,84 Housing insulation, mineral wool [mm] 3 Colour RAL white 916 Weight (net, without packing) [kg] 13 Comply with ERP 216;218 * Calculated according EN 13141-7. (balanced mass flow) EN 13141-7: RIS 7PW EKO 3. LWA, Supply 75 64 66 68 7 66 6 59 Extract 62 53 55 57 56 52 49 45 Surrounding 56 45 47 5 5 47 43 42 Measured at 7 m 3 /h, Pa 69

RIS 1PE EKO 3. RIS 1PE EKO 3. Extract air Outdoor air GAGRIS1744_22A 1PE 3. EKO 3. Integrated electrical heater GAGRIS1745_21B 1PE 6. EKO 3. Integrated electrical heater GAGRIS171_2B 1PE 9. EKO 3. Integrated electrical heater 3. EKO 3. 6. EKO 3. 9. EKO 3. Electrical heater phase/voltage [5Hz/VAC] ~1, 23 ~3, 4 ~3, 4 [kw] 3, 6, 9, EC fans phase/voltage [5Hz/VAC] ~1,23 exhaust power/current [kw/a],45/2,95 fan speed [min -1 ] 34 supply power/current [kw/a],37/2,5 fan speed [min -1 ] 34 Max power consumption [kw/a] 3,82/18,49 6,82/14,19 9,82/18,49 Housing insulation, mineral wool [mm] 5 Colour RAL grey 74 Weight (net, without packing) [kg] 17 Comply with ERP 216;218 * Calculated wet efficiency. (balanced mass flow) : RIS 1PE EKO 3. LWA, Supply 76 58 69 71 69 67 64 56 Extract 64 52 56 61 56 5 45 42 Surrounding 56 42 48 5 49 48 46 4 Measured at 1298 m 3 /h, Pa 7

RIS 1PW EKO 3. RIS 1PW EKO 3. Extract air Outdoor air GAGRIS1721_23A 1PW EKO 3. Optional water heater 1PW EKO 3. Water heater (optional) SVS 5x25 Fans phase/voltage [5Hz/VAC] ~1,23 exhaust power/current [kw/a],45/2,95 fan speed [min -1 ] 34 supply power/current [kw/a],37/2,5 fan speed [min -1 ] 34 Max power consumption [kw/a],82/5,49 Housing insulation, mineral wool [mm] 5 Colour RAL grey 74 Weight (net, without packing) [kg] 17 Comply with ERP 216;218 * * Calculated wet efficiency. (balanced mass flow) EN : RIS 1PE EKO 3. LWA, Supply 76 58 69 71 69 67 64 56 Extract 64 52 56 61 56 5 45 42 Surrounding 56 42 48 5 49 48 46 4 Measured at 1298 m 3 /h, Pa 71

RIS 19PE EKO 3. 6 5 4 3 6 5 RIS 19PE EKO 3. 4 3 Extract air Outdoor air GAGRIS1751_25A 19PE 3. EKO 3. Integrated electrical heater GAGRIS1752_24B 19PE 6. EKO 3. Integrated electrical heater GAGRIS176_1B 19PE 12. EKO 3. Integrated electrical heater 3. EKO 3. 6. EKO 3. 12. EKO 3. Electrical heater phase/voltage [5Hz/VAC] ~1, 23 ~3, 4 ~3, 4 [kw] 3, 6, 12, EC fans phase/voltage [5Hz/VAC] ~1, 23 exhaust power/current [kw/a],485/3,12 fan speed [min -1 ] 254 supply power/current [kw/a],488/3,16 fan speed [min -1 ] 254 Max power consumption [kw/a] 3,97 /2,32 6,97 /14,92 12,97 /24,32 Housing insulation, mineral wool [mm] 5 Colour RAL grey 74 Weight (net, without packing) [kg] 269 27 272 Comply with ERP 216;218 * Calculated wet efficiency. (balanced mass flow) : RIS 19PE EKO 3. LWA, Supply 77 53 64 69 73 7 65 61 Extract 68 42 58 64 62 61 58 55 Surrounding 6 5 52 54 54 5 48 41 Measured at 1938 m 3 /h, Pa 72

RIS 19PW EKO 3. 6 5 4 3 6 5 4 3 Extract air Outdoor air GAGRIS1753_26A 19PW EKO 3. Optional water heater RIS 19PW EKO 3. 19PW EKO 3. Water heater (optional) SVS 7x4 Fans phase/voltage [5Hz/VAC] ~1, 23 exhaust power/current [kw/a],485/3,12 fan speed [min -1 ] 254 supply power/current [kw/a],488/3,16 fan speed [min -1 ] 254 Max power consumption [kw/a],97 /6,32 Housing insulation, mineral wool [mm] 5 Colour RAL grey 74 Weight (net, without packing) [kg] 269 Comply with ERP 216;218 * Calculated wet efficiency. (balanced mass flow) : RIS 19PW EKO 3. LWA, Supply 77 53 64 69 73 7 65 61 Extract 68 42 58 64 62 61 58 55 Surrounding 6 5 52 54 54 5 48 41 Measured at 1938 m 3 /h, Pa 73

RIS 25PE EKO 3. RIS 25PE EKO 3. Extract air Outdoor air GAGRIS1754_27B 25PE 4.5 EKO 3. Integrated electrical heater GAGRIS1755_28B 25PE 9. EKO 3. Integrated electrical heater GAGRIS177_15B 25PE 18. EKO 3. Integrated electrical heater 4.5 EKO 3. 9. EKO 3. 18. EKO 3. Electrical heater phase/voltage [5Hz/VAC] ~3, 4 ~3, 4 ~3, 4 [kw] 4,5 9, 18, EC fans phase/voltage [5Hz/VAC] ~1,23 exhaust power/current [kw/a],725/3,24 fan speed [min -1 ] 28 supply power/current [kw/a],675/3 fan speed [min -1 ] 28 Max power consumption [kw/a] 5,9 /12,78 1,4 /19,28 19,4 /32,28 Housing insulation, mineral wool [mm] 5 Colour RAL grey 74 Weight (net, without packing) [kg] 322 Comply with ERP 216;218 * Calculated wet efficiency. (balanced mass flow) : RIS 25PE EKO 3. LWA, Supply 8 6 68 72 75 74 71 65 Extract 69 56 6 64 63 6 58 41 Surrounding 62 46 54 56 57 54 5 45 Measured at 2548 m 3 /h, 12 Pa 74

RIS 25PW EKO 3. GAGRIS1756_29A 25PW EKO 3. Optional water heater RIS 25PW EKO 3. Extract air Outdoor air 25PW EKO 3. Water heater (optional) phase/voltage [5Hz/VAC] SVS 7x4 Fans phase/voltage [5Hz/VAC] ~1, 23 exhaust power/current [kw/a],725/3,24 fan speed [min -1 ] 28 supply power/current [kw/a],675/3 fan speed [min -1 ] 28 Max power consumption [kw/a] 1,4 /6,28 Housing insulation, mineral wool [mm] 5 Colour RAL grey 74 Weight (net, without packing) [kg] 322 Comply with ERP 216;218 * Calculated wet efficiency. (balanced mass flow) : RIS 25PW EKO 3. LWA, Supply 8 6 68 72 75 74 71 65 Extract 69 56 6 64 63 6 58 41 Surrounding 62 46 54 56 57 54 5 45 Measured at 2548 m 3 /h, 12 Pa 75

RIS 4PE EKO 3. / RIS 7PE EKO 3. (ceiling mounted) versions with electrical heater AVA IV - exhaust air fan PV - supply air fan PR - plate heat exchanger PF - filter for supply air (class F7) IF - filter for extract air (class M5) KE - electrical heater M1 - actuator of by-pass damper TL - fresh air temperature sensor TJ - supply air temperature sensor TE - exhaust air temperature sensor DTJ.1- humidity + temperature sensor AVA - optionally supplied water cooler EKA NV PH - optional fresh air pre-heater RIS 1PE EKO 3. / 19PE EKO 3. / 25PE EKO 3. (ceiling mounted) versions with electrical heater EKS NV PH IV - exhaust air fan PV - supply air fan PR - plate heat exchanger KE - electrical heater PF - filter for supply air (class F7) IF - filter for extract air (class M5) TE - temperature sensor for exhaust air TL - temperature sensor for fresh air EKS NV PH - optional fresh air pre-heater DTJ.1 - humidity + temperature sensor TJ - temperature sensor for supply air M1 - actuator of by-pass damper PS1 - supply air differential pressure switch PS2 - extract air differential pressure switch PS3 - heat exchanger antifrost pressure switch 76

RIS 4PW EKO 3. / RIS 7PW EKO 3. (ceiling mounted) versions with water heater AVA T1 EKA NV PH DTJ.1 IV - exhaust air fan PV - supply air fan PR - plate heat exchanger PF - filter for supply air (class F7) IF - filter for extract air (class M5) TV - antifrost sensor M1 - actuator of by-pass damper AVA - optionally supplied water cooler M4 - water heater circulation pump M6 - optionally supplied mixing valve and motor TL - fresh air temperature sensor TJ - supply air temperature sensor TE - exhaust air temperature sensor T1 - antifrost thermostat DTJ.1 - humidity + temperature sensor AVS - optionally supplied water heater EKA NV PH - optional fresh air pre-heater RIS 1PW EKO 3. / RIS 19PW EKO 3. / 25PW EKO 3. (ceiling mounted) versions with water heater EKS NV PH DTJ.1 IV - exhaust air fan PV - supply air fan PR - plate heat exchanger PF - filter for supply air (class F7) IF - filter for extract air (class M5) TE - temperature sensor for exhaust air TL - temperature sensor for fresh air TJ - temperature sensor for supply air T1 - antifrost thermostat TV - antifrost sensor DTJ.1 - humidity + temperature sensor M1 - actuator of by-pass damper M4 - water heater circulation pump M6 - optionally supplied mixing valve and motor PS1 - supply air differential pressure switch PS2 - extract air differential pressure switch PS3 - heat exchanger antifrost pressure switch SVS - optionally supplied water heater EKS NV PH - optional fresh air heater 77

Description of the functions Fans Functions FUNCTIONS Date and time settings 4 speeds for easy and user-friendly control ( Stop the unit is stopped; Low, medium, and High. Service menu allows adjusting each speed individually) Electric heater Water heater DX cooler Water cooler Bypass damper Filter pollution monitoring Sensors Functional units Emergency signals and inputs/outputs Remote controllers BOOST function (Fans operate at highest speed) Comfortable air temperature function Cold/heat recovery Fire place function Dryness protection Weekly schedule Holiday schedule User and service control levels Manual air flow balancing CO 2 level indication and reduction function Night cooling function Relative humidity (RH) level indication and reduction function Software and configuration update possibility temperature control according to the extract air sensor E RIS EKO 3. Monitoring function (all sensors and I/O) 2 2 Mode switch (start/stop) Extracted air relative humidity converter Manual components control 1 1 Soft start and stop Fan failure protection Speed synchronous/asynchronous -1V control On/Off / PWM control Manual protection Overheat protection (additional protection software) Pulse-width modulation (PWM) valve actuator control Protection using temperature sensor Protection using termostat (NC) Circulation pump control Return water temperature sensor Control On/Off Pulse-width modulation (PWM) valve actuator control Control with three-positional valve actuator 3-position actuator control By pressure switch (NC) By filter timer temperature sensor Fresh air temperature sensor temperature sensor Extract air temperature sensor Fire protection input Working indication output Alarm indication output Stouch Flex Ptouch MB-Gateway W 1 With FLEX TEST remote controler 2 Only sensors 78