X11CA COMPUTER ANNUNCIATORS

Similar documents
X16PDM P R O G RAMMABLE

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

AIS750 Series Alarm Annunciator

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Model A1700 Series Annunciator

AN-3100D Annunciator

Series 725 Programmable Alarm Annunciator

System 9000TS Sequence of Events Recorder

Model A1600 Series Annunciator

Model A2100 Series Annunciator

DRAFT 20 October 2014

21-light Remote Annunciator. Owner s Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

Across-the-Line SERIES MP300 Combined Manual and Automatic

Soft Start Series MP700 Solid State, Reduced Voltage

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

SIL725 Safety Annunciator

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Complex alarming made simple

725B Configuration Software Manual

AO Annunciator Module

System 9000TS Event Recorder

ESP TECHNOLOGIES LIMITED

Variable Frequency Drive SERIES MP800 VFD

Annuciator Logic Controllers

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Conventional Releasing Control Panel

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

System 9000TS Sequence of Events Recorder

ME 3011C / Alarm Indication / Quick Reference Guide

Plant Security & Fire Alarm Systems. HVAC Systems. Power Plants & Switchyards. Geographical Maps. Industrial Process Plants

For Complete Fire and Gas Solutions

IntesisBox BACnet/IP Server - Notifier ID3000 series

Dependable Solutions for Gas Detection

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Industrial Grade Gas Detection Detecting The Difference

Fire and Gas Monitoring Panel ST7-HV

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

ACCURATE ELECTRONICS INC

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

ESSEX ENGINEERING CORPORATION

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

M1000 Alarm Annunciator

SEL-2523 Advanced Annunciator Panel

Addressable Fire Alarm Control Panel

MODEL B2 INSTALLATION MANUAL

Annunciator Sequences and Specifications

STATUS ALARM HISTORY ALARM RESET

I/A Series 716C 1/16 DIN Temperature Controller

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

INTELLIGENT FIRE ALARM CONTROL PANEL

SACO 16D3 Annunciator unit. User s manual and Technical description

INTREPID Perimeter Intrusion Detection System

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

Two-Channel Gas Controller

GasGard 100 Control System

Sensor Interface Module Installation/Operation Instructions

Flair 500 Series Annunciators

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Commercial and Light Industrial Fire Alarm Control Panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Specification/ Data Sheet

CAREL heatersteam Electric Element Steam Humidifiers

IF-L/RF Protection Switch

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Galaxy Pulsar Plus Digital Battery Plant Controller

SECTION AUTOMATIC TRANSFER SWITCHES

Window facia fault annunciators

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

TrueAlarm Fire Alarm Systems

Nov 08 PRODUCT SPECIFICATION SHEET

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

ACTIVE INFRARED BARRIER

INSTALLATION INSTRUCTIONS

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

CTT8 TEMPERATURE MONITOR DEVICE

Burner Company. Flame Safeguard Systems. Bulletin IG-1. Bulletin FS-1

RELEASE DEVICE CONTROLS

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

RS485 MODBUS Module 8AI

ModBus DE-1 INSTALLATION AND USER MANUAL

Transcription:

S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y

The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models. The XCA is designed for the process and power industries requirements, providing the most economical approach while offering the most advanced data acquisition in serial technology and monitoring, along with Ronan s high quality and performance standard. The systems in the Window Annunciator feature Monalarm, Dualarm, Trialarm and Quadalarm within Ronan s standard.0 inch (88.90 mm) by.0 inch (88.90 mm) mechanical cabinet modules. A system common trouble and a per-point auxiliary relay output may be utilized for field contact repeater or for remote group alarms. The system monitors internal routines and communication backbone, signaled by dedicated LED or relay contact closure. The XCA is equipped with a host interface module that provides advanced communication interface protocols to interface with an external host computer, local network, or plant network. F E A T U R E S INPUTS Dry Contact, System Powered Vdc ly Open/ly Closed Live Contacts (Isolated) Vdc, 8 Vdc, Vdc or Vac, 0 Vac SEQUEE All Standard ISA s User Configurable OUTPUTS Dual Configurable Auxiliary Contact Double Throw Selectable ly Energized or De-energized GP or HS Relays May be Added in the Field Common System Trouble Reflash System Trouble Serial Input/Output Protocol Ronan Proprietary MODBUS RTU Slave TCP/IP DNP.0 Serial Interface Object Linking and Embedding for Control (OPC) DESIGN TECHLOGY Microprocessor Based Noise Immunity Field Proven Off-the-shelf Worldwide Serial Input/Output Comprehensive User Configuration with Standard Software MECHANICAL Flush Ergonomic Front Panel Design Total 7.0 Inches (90.0 mm) Deep Light Weight Reinforced Terminal Block LIGHTING LED Colors: Red, Green, Amber, White, Blue Dual Bulbs Watts Each (Can use Watt with Transparent Film) COLOR CODING Eight Bezel Colors Colored Lenses Sandwich Lenses WARRANTY Three () Years APPROVALS UL Underwriters Laboratories CUL Canadian Underwriters Laboratories EMI/RFI CAPABILITY IEC 80-, -, -, - CE Compliant to EN008-/ EN008-

SYSTEM ELOSURES The Ronan XCA Computer Annunciator Systems with microprocessor based electronics are assembled from basic.0 inch (88.90 mm) by.0 inch (88.90 mm) modules to make up the overall size requirements and number of windows required. The mechanical modules assembled from aluminum castings and extrusions provide excellent heat dissipation for a continuously lit annunciator system and feature the structural strength required in industrial applications. The rear terminal is designed as a single piece molded plastic assembly per window for durability. A small. inch (8. mm) wide x 7. inch (89. mm) high x.00 inch (.0 mm) deep module (interface module), is provided to connect the system to an external host. All enclosures are painted with baked black semigloss enamel. Custom colors are optionally available. NEMA OR NEMA WINDOW The Panel-mount enclosure may be enhanced with a NEMA or NEMA door assembly to seal the front of the alarm system against control panels where it is subject to moisture or corrosive atmosphere. The door is supplied with a clear acrylic window, sealed with a neoprene gasket. Gasketing is supplied for sealing between door frame and control panels. PANEL-MOUNT The Panel-mount NEMA type enclosure, for control panel applications, mounts through a rectangular cutout and secures to the panel with a number of simple clamping devices supplied with each system. RACK-MOUNT The Ronan alarm system with various window sizes is available for standard 9.00 inch (8.0 mm) or.00 inch (09.0 mm) relay rack mounting. The five mechanical module wide unit is suitable for 9.00 inch (8.0 mm), and the six module wide unit can be used for.00 inch (09.0 mm) rack spacing. SURFACE-MOUNT The Ronan Surface-mounted mechanical arrangement alarm system provides front termination access. It is used for applications where the annunciator is to be in an explosion proof housing or NEMA enclosure, and for applications where a surface mounted window annunciator is found more suitable.

TEST SIL ACK RESET MONALARM, DUALARM, TRIALARM, QUADALARM SERIES MODELS XCA- 0 0 0, - 000,-000,-000 This Panel-mounted Series of computer annunciators is used for control panels. Various colors of bezels are available with four different configurations housed within the mechanical cabinet modules. A Overall B Cutout A 0.8" (9. mm) Maximum Panel Thickness A Overall B Cutout Optional Push Buttons 7.78" (97. mm) 9." (.9 mm) 0.7" (9.0 mm) Conduit Knock-out Optional Rear Cover MODELS XCA-RR- 0 0 0, -000,-000,-000 The Relay Rack-mounted Series of computer annunciators has a standard length of 9.00 (8.0 mm). An optional.00 (09.0 mm) length is also available. 8." (.07 mm).8" (0. mm) A Overall Field Contact Terminals 9.00" (8.0 mm) Overall." (9.78 mm) Fuse MODELS XCA/XCA-RR- 0 0 0, - 000,-000,-000 Rear Terminal Arrangement for Wiring Notes for XCA/XCA-RR: (H) Field Contact Voltage for Dry Contact or Live Input (FC) Field Contact Return (ME) Connect All First Out in a Group (TO) Transistor Output Driver Auxiliary Output / Selectable Notes for XCA-IM: TO: A, A, CTA, RFL RUN for Transistor Driver* A, A, CTA, RFL, RUN for Relay Output** : ly Open COM: Common : ly Closed A: Horn A: Horn CTA: Common Trouble RFL: Reflash RUN: System Diagnostic GP, GP: Programmable Function (Special Function) D C B Field Control Wiring for All Positions Dry A D C B A D C B A FV V+ V- G Communication Cable Live + XCA-000 (H) (FC) (ME) (TO) + Vdc Power Supply To XCA-IM Aux. Output

Panel Front Frame Clamp Assembly Jam Nut Cabinet Detail A XCA-000 XCA-000 XCA-000 XCA-000.90.. 07.9 8.0. 7.7 9.8 9.90 0.. 8.7 8 8 8.0 9..7 7. 0 0 0 8.90 80.0 8.. 8.0 8.9.7. 7 7 7 7.90 7.8.. 8 8 8 8 9.0 7.7 8.7 70. 9 9 8 9 7 9 8 8.90 8.. 89. 0 0 0 0 0 0 0 0.0 9..7 908.0 9.90 0. 9. 99.9.0 0..7 08.8 Specifications subject to change without notice. Inches A Overall mm Inches B Cutout mm Nameplate Sizes: Monalarm.00 inches (7.0 mm) x.00 inches (7.0 mm) Dualarm. inches (.8 mm) x.00 inches (7.0 mm) Trialarm 0.8 inches (.8 mm) x.00 inches (7.0 mm) Quadalarm.0 inches (. mm) x.0 inches (. mm) XCA-RR-000 XCA-RR-000 XCA-RR-000 XCA-RR-000 ** ** ** 0**.0 88.90 0 7.00 77.80 9 0 0.0.70 * 8* * 8* 0.00.0 * Not limited to high. ** Limited to wide only. 9.00 (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. * Not limited to 8 high. ** Limited to wide only. 9.00 (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. * Not limited to high. ** Limited to wide only. 9.00 (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. * Not limited to 8 high. ** Limited to 0 wide only. 9.00 (8.0 mm) rack. Also available wide.00 (09.0 mm) rack. Inches A Overall mm Field Control Wiring for All Positions Dry Live + B A FV V+ V- G B A B A Test Silence (H) (FC) Reset (ME) (TO) First Out Reset GP Aux. Output GP RS8 To Host RS A A TO CTA RFL RAN A COM A COM CTA COM RFL COM RUN COM GND V- V+ V+ XCA-IM TEST SIL ACK RST FRST GP GP TX+ TX- P GND RS8 RX+ RX- PRGM RUN P RS P * ** AC Horn Horn Horn Electronic Horn To Power as Required XCA-000 (+) Vdc ( ) Power Supply or DC to DC Converter P P RXD TXD RXD TXD ERROR RUN XCA-IM H(+) N( ) G Communication Cable Vac or Vdc * Open Collector Outputs **Relay Contact Outputs

SEQUEE DIAGRAMS Return to Off To while Return to Off First to Subsequent to d while or or Subsequent On Flashing On SEQUEE A Automatic Reset and Test Push Buttons Device Lock-in of Momentary s until d The Device is Silenced and Flashing Stops when d Automatic Reset of d Indications when Conditions Return to Operational Test Return to Subsequent to d On and Test Push Buttons Device Lock-in Momentary First until d No Lock-in of Momentary Subsequent s Flashing and Indications for First Only New Subsequent s Go to the d State First Out Indication is Reset and the Device is Silenced when d Automatic Reset of d Indications when Conditions Return to Operational Test Off while (First Out Reset) while (First Out Reset) SEQUEE FA Automatic Reset First Out with No Subsequent State First to or First Flashing or d On (First Out Reset) (First Out Reset) or First Silenced Flashing Silence or First Flashing SEQUEE FM- Manual Reset First Out with No Subsequent Flashing and Silence Push Button Silence,, Reset and Test Push Buttons FA, Automatic Reset First Out Device with No Subsequent State d Option : Silence Push Button to Silence the Device while Retaining First Out Flashing Indication Flashing Indication for First Only New Subsequent s have the Same Indication as d s First Out Indication is Reset when d Manual Reset of d Indications, Conditions Return to Operational Test ORDERING Typical Method of Specifying s with Options Using ISA Standard Nomenclature Basic Letter R - - - 9 Option Numbers F M - Basic Letter Option Number First Out Designation

Return to Off First to Reset while Off To while Subsequent to or Subsequent or d or Fast Flashing On Flashing First Out Reset while Subsequent d On while First Out Reset or First d Flashing or First Intermittent Flashing SEQUEE M Manual Reset, Reset and Test Push Buttons Device Lock-in Momentary s Until d The Device is Silenced and Flashing Stops when d Manual Reset of d Indications after Conditions Return to Operational Test SEQUEE FA Automatic Reset First Out Reset with First Out Flashing and Reset Push Button First Out Reset and Test Push Buttons Device Lock-in of Momentary s until d First Out Flashing Different from Subsequent Flashing First Out Reset Push Button to Change the First Out Indication to be the Same as Subsequent Indications Automatic Reset of d Indications when Conditions Return to Operational Test Ringback Reset RingBack Slow Flashing Ringback Off while Return to To Ringback or Fast Flashing Basic Option Key Words Number Letter Key Words A Automatic Reset Silence Push Button M Manual Reset Silence Interlock R Ringback First Out Reset Interlock No Lock-in No Flashing No 7 Automatic Silence 8 Common Ringback 9 Automatic Ringback Silence First Out Option Key Words Designation Number Key Words F No Subsequent State 0 No Ringback F No Subsequent Common Ringback Flashing F First Out Flashing and Automatic Momentary Reset Push Button Ringback Dim Lamp Monitor Lamp Test Return to Ringback On while SEQUEE R Ringback, Reset and Test Push Buttons and Ringback Devices Lock-in of Momentary s until d The Device is Silenced and Fast Flashing Stops when d Ringback and Indications when Conditions Return to Manual Reset of Ringback Indications Operational Test 7

XCA MODULES HOST INTERFACE MODULE The Model XCA-IM Interface Module connects the XCA Window Annunciator with external host devices. Hosts can be a DCS, PLC, or plant computer. An isolated RS8 or a 0 Base T network connection is used with the most common industry accepted communication standards such as MODBUS, DF, and TCP/IP protocols for host communication. The Module provides a number of special features such as time-stamped event archive, common trouble alarm, dual horn output, reflash output, and system diagnostic output. All 7." (8.0 mm) 7." (89. mm).00" (7.0 mm).00" (.0 mm) V+ XCA-IM A TEST A SIL TO CTA ACK RFL RST RAN FRST GP A COM GP TX+ TX- A COM P GND RS8 RX+ RX- CTA COM RFL COM PRGM RUN P RS RUN COM GND V- V+ P P P RXD TXD RXD TXD ERROR RUN." (8. mm) 0." (.0 mm) Dia. outputs are provided in the forms of an open collector transistor and selectable Form C relay dry contact. Additional on-board LEDs are designed to indicate serial communication and system status. The XCA-IM Interface Module is used to interface via a laptop or PC with the Ronan XCA configuration software for programming sequences, input/output assignment, and all other selectable features. ALARM SEQUEE/DISPLAY MODULE 8 The Ronan Model XCA Annunciator module is designed with all common sequences and options available internal to the module, allowing for field programmable selections of all commonly used ISA sequences through a computer or laptop. Selection of field contact polarity is allowed through the on-board jumpers per channel. Each combination of alarm/display module contains a single, dual, triple, or quad alarm channel with associated lamp or LED displays. The modules are removable from the front without interfering with the system. The XCA Window Annunciator display lens area is a back-lit window with standard colored bezels. The single or sandwich lens allows multi-line legend.

MONALARM The Monalarm plug-in Module features single channel alarm logic with two -watt incandescent or optional LED type indicators illuminating a.00 inch (7.0 mm) high by.00 inch wide (7.0 mm) window. DUALARM The double window Dualarm Module contains two channels of alarm logic to display alarm conditions on two windows sized for. inch (.8 mm) high and.00 inch (7.0 mm) wide lenses. TRIALARM The three window Trialarm Module provides three 0.8 inch (.8 mm) high by.00 inch (7.0 mm) wide nameplates and is illuminated by three sets of two -watt lamps or LED type indicators. Each set is driven by one channel of the three-channel alarm logic. QUADALARM The four window Quadalarm Module represents the highest density of annunciation in the XCA series. The.0 inch (. mm) high by.0 inch (. mm) wide window is illuminated by two -watt lamps or LED indicators. 9

XCA MODULES PUSH-BUTTON CONTROL The XCA system provides for an integral membrane push-button interface module or, as an option, a membrane switch overlaid on the rim of the system frame. The latter design allows full use of all module position input channels in each system. All external push buttons are interfaced through the interface module. The system alarm input modules provide self-generating flash signals that operate the flash sequence on indicators independently. All module flash generators are synchronized by the interface module. AUXILIARY CONTACT MODULES The Auxiliary Contact Modules are available for the XCA Window Annunciator with a separate relay circuit for each window. The modules plug in from the front of the system. They may be purchased initially, or added later in the field without any additional system components. Each relay provides for a form A or B type contact, normally open or normally closed, and normally energized or normally not energized, and is selectable by a jumper switch. 0

COMMUNICATION / PROTOCOLS The Ronan XCA Window Annunciators have comprehensive serial alarm communication facilities to interface to Host machines and transfer field input status to, or receive alarm data from PLCs, DCSs, Network Servers and Computers. MODBUS RTU SLAVE The MODBUS RTU Slave protocol allows users of PLCs and DCSs that are operating as MODBUS Masters to periodically acquire the status of annunciator inputs or transmit alarms to the annunciator for process monitoring. Status of the annunciator is continuously updated in a pre-defined Memory Register Map which complies to the MODBUS protocol. The Host (MODBUS Master) periodically reads or writes to the Memory Register Map serially using pre-defined MODBUS command sets. The data is then used for process monitoring. Events XCA-IM DCS, PLC or Computer XCA ALLEN BRADLEY DF INTERFACE The Allen Bradley DF protocol allows users of AB PLCs to periodically acquire or transmit alarm data to or from the annunciator for monitoring and control. The input status is periodically transmitted as a bitmap complying to the DF protocol. The PLC provides an open serial port to send or receive the bitmap status.

COMMUNICATION / PROTOCOLS NETWORK TCP/IP Transport Control Protocol/Internet Protocol (TCP/IP) The Ronan XCA provides as an optional connection to a local or plant network using the XCA-IM interface module and XCA-NM network converter module. The input alarm status is transmitted or received via TCP/IP at speeds of up to 0 MB all across the network. Typical TCP/IP Address 9.8.0. 0 Base T Ethernet 0 Base T XCA-IM XCA-NM Network Hub XCA Other Network Device Plant Network RONAN PROPRIETARY (/) The XCA provides features to serially transmit input alarm status to external host devices through XCA-IM. This feature can be used to transfer input alarm status serially to Ronan s X0 Serial Annunciator for remote visual annunciation display. Lamp Box Lamp Box XCA-IM X0-A X0-B XCA Events RS/RS8

OPC INTERFACE (Object Linking & Embedding for Control) OPC is designed to allow client applications access to alarm input status of a system in a consistent manner. With wide industry acceptance, OPC provides easy integration into the common Human Machine Interface (HMI) applications widely used in the process industry. OPC Client OPC Client Local OPC Server Ronan OPC Interface Driver XCA Ethernet Network OPC Server XCA-NM Ronan OPC Driver OPC Interface Typical TCP/IP Address 9.8.0. XCA-IM TYPICAL APPLICATION The XCA Serial Annunciators features an optional bit NT driver and mechanisms for OPC clients to be notified of the occurrences of specified events and alarm conditions. They also provide services which allow OPC clients to determine the events and conditions supported by an OPC server, and to obtain their current status. Graphics OPC Client Typical TCP/IP Address 9.8.0. Computer with HMI Interface OPC Server XCA-NM XCA-IM XCA Plant Ethernet Network

CONFIGURATION XCA-CONFIGNT The Ronan XCA Window Annunciators are configured fully with the use of a graphical user interface application operating in a environment on a PC or Laptop through an RS serial connection to the XCA-IM interface module. The application allows factory or field programmability of all features for each window. Configuration data is saved in non-volatile memory on-board each module. Selections such as alarm sequence, first out grouping, operational or lamp test, output signals follow alarm or field contact, time delay and special functions are all set through the configuration application software.

BEZELS AND ENGRAVING The XCA Window Annunciator can be supplied with engraved letters (top two examples) for all different models of bezels, or customized with laser printed lettering (bottom two examples) on heat resistant, translucent thin film material. Letter Size (Inches) Characters per Line Lines Bezels Shown Actual Size Monalarm Series 000 Model WB-( )* Dualarm Series 000 Model WB-( )* Trialarm Series 000 Model WB-( )* Quadalarm Series 000 Model WB-( )* *Color code typical bezel ordering information: WB-(0) = Black bezel for Trialarm Series