FASTflo. Working towards a cleaner future

Similar documents
This manual must be kept with the appliance

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Copper-Fin GAS-FIRED WATER HEATERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Sirius FS. Working towards a cleaner future

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Sirius WH. Working towards a cleaner future

Light commercial products. High output boilers Cascade systems

economy environment engineering excellence Advanced Commercial Hot & Warm Water Solutions

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

MAXIMISER Semi-Storage Calorifiers

Multipoint Technical Data

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Installation and Servicing Instructions. Alpha FlowSmart

LBF RANGE BALANCED FLUED WATER HEATERS

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Our commitment to you

heat interface units A BOILER WITHOUT A FLAME

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

Stored Water District Heating Interface Units. Heat Interface Units

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

SGE Condensing Gas - Solar Water Heater

extreme HIGH EFFICIENCY HOT WATER SYSTEMS

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Installation and Servicing Instructions. Alpha GasSaver GS-1

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Working towards a cleaner future. Andrews Water Heaters Product Guide. 9.5kW to 550kW

Alpha CombiMax 350 and 600

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

1 VICTRIX ZEUS Superior kw I features

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Breeze extended to include Variable Speed Drives Breeze range extended to include Steam Primary

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Broag Pressurisation equipment

HOT WATER SYSTEMS.

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Unvented Hot Water Criteria

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Residential Heating Boilers

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Performance on demand

Installation & Technical Guide. Domestic & Commercial.

Installation and User Instructions HS10U, HS15U.

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

ENERGY TOP. Condensing boiler solutions

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Where gas is not an option,

Instructions for Use Installation and Servicing

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

SEALED THERMAL STORE

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

SATK 30 heat interface unit

Fusion 200, 300 & 500

Hydraulic Installation

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

User's Instructions. Alpha CB50

Commissioning Pack. Heating and Hot Water Heat Pumps. IMPORTANT DOCUMENTS To Be Kept At All Times. With Equipment. Accredited Ecodan Installer:

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

the electric heating company ELECTRIC BOILER HANDBOOK

Alpha FlowSmart 25 and 50

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

VORTEX BLUE OIL RANGE

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

VORTEX BLUE OIL RANGE

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

The iqe Boiler Range. Combination and System T Boilers.

INSTALLATION GUIDE, OPERATION AND SERVICE MANUAL

Series 1000 & Storage Water Heaters

EPU - WM30 EPU - WM 50 EPU - WM100

Installation and Servicing Instructions. Alpha GasSaver GS-2

Andrews Water Heaters

Baxi Maxflow Combi WM

aquaplus High performance combination boiler with integrated power store

BFC Cyclone Condensing Glass-Lined Water Heater

Baxi Maxflow Combi FS

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Hamworthy Dorchester DR-FC Evo 98%

GAS WATER HEATER WH42, LWH42, WH56, LWH56 (Internal) WHX42, LWHX42, WHX56, LWHX56 (External)

Packaged Solutions. Basic Packages

Gas Fired Storage Water Heaters

C Tahiti. condensing

Transcription:

NOW INCLUDES FASTflo PLUS Condensing Model FASTflo Continuous Flow Wall Hung range Balanced Flue Water Heaters Working towards a cleaner future

FASTflo Continuous Flow Wall Hung Balanced Flue Water Heaters, now including a condensing model The FASTflo range is ideal for commercial or large domestic applications where an endless supply of hot water is required. Unlike old instantaneous type water heaters, the design measures the incoming water flow and temperature then modulates the burner up or down to meet the desired hot water demand with plus or minus one degree accuracy. This technology ensures a continuous flow of hot water, that is also very safe to operate. Supplied with a BS Gas Cock, Installation Manual and Owners Guide. Further benefits Hot water on demand, with efficiency up to 103% (applies to Condensing Unit) Modulating burner and no stand-by heat losses Automatic ignition means no costs whilst unit is not in use Compact and light for easy location and installation Accurate temperature settings from 37ºC to 80ºC Condensing model available Internal room sealed and external models Factory fitted anti-frost protection on all models Safe and constant flow of endless hot water Reduced risk of harmful legionella bacteria forming Flue systems to suit most applications Remote Controller A remote controller, designed especially for the Andrews WH, WHX and WHC range of heaters, is required to operate the appliance*. This allows external adjustment of the required flow temperature and in addition provides a wide range of operation and fault diagnosis information. The remote controller is easily connected to the appliance by the low voltage cable supplied. * Please note that 1 remote controller is required per installation and must be purchased separately. Unvented System Kits If continuous flow water heaters are used on circulation systems an unvented system kit is required to allow for expansion of the hot water system. The kit includes the necessary safety devices required to confirm to the current building regulations. Three sizes of kit can be supplied and each contains a combined strainer/pressure reducing valve set to 3.5 bar, check valve, expansion valve set to 6.0 bar, tundish, 5 litre expansion vessel, wall bracket and hose. When the circulation system includes a storage cylinder/buffer vessel, a combined temperature/pressure relief valve must be sized to suit the total input of all the water heaters installed on the system (see table above right). This must be located on the storage unit. In addition the size of the expansion vessel must also be increased to suit both the storage cylinder plus the contents of the system pipework (see vessel table). Unvented System Kit Part No Size B235 3 4 inch dia. B234 1 inch dia. B276 1 1 4 inch dia. Tundishes Part No Size C384 1 inch 1 1 4 inch E326 1 1 2 inch 2 inch E497 2 inch 2 1 2 inch E497 2 inch 2 1 2 inch E497+C384 2 inch 2 1 2 inch + 1 inch 1 1 4 inch Expansion Vessel Part No Size C782 25 litre, 3.5 bar C789 40 litre, 3.5 bar Temperature and Pressure Relief Valves Part No Total Output Quantity & Size of Valves C380 Up to 56kw 1 x 1 inch E242 Up to 112kw 1 x 1 1 2 inch E242 + C456 Up to 126kw 1 x 1 1 2 inch + 1 x 3 4 inch E291 Up to 168kw 1 x 2 inch E497 E291 + C380 Up to 224kw 1 x 2 inch + 1 x 1 inch

Stainless steel secondary heat exchanger FASTflo Internal FASTflo External FASTflo PLUS Condensing model Internal view Multiple Units Andrews continuous flow water heaters can be combined in multiples of up to six units to provide a plentiful supply of hot water. With a temperature rise of 45ºC up to 1.8 litres/second (108 litres/minute) can be supplied constantly. Please refer to the water flow table. When installing two units in parallel, a Quick Connect Cord Kit can be installed which requires only one remote controller and a quick connect cord. For multiple installations of up to six units a System Controller is available (WH42, WH65, WHX56 and WHC56). This will ensure that when a small draw off occurs all the flow will pass through the lead unit (priority changes) rather than dividing the flow through all of them. As the flow rate increases additional units will fire thus maintaining the required system flow temperature. Other features of the System Controller includes BEMS fault indicator, remote power on indicator, circulation pump connection and remote switching. The Quick Connect Cord Kit or System Controller is not required when the installation incorporates a storage cylinder/buffer vessel or if a constant large volume of hot water is required. Please contact our Sales Department for more details. 1. Strainer 2. Pressure reducing valve 3. Non-return valve 4. Expansion vessel 5. Expansion valve and Tundish 1 2 3 4 5 Cold supply 3 Bronze recirculating pump Manifolded units with primary flow and pumped secondary re-circulation pipework complete with suitably sized mains unvented systems kit. Cold supply Five units connected in parallel without secondary re-circulation. Building flow Gas Hot outlets Gas Hot outlets

Circulating pumps When installing single or multiple units on a secondary pumped re-circulation system a minimum flow rate must be maintained to achieve optimum performance from the appliance, please refer to the pump selection table. When installing multiple units in conjunction with a storage cylinder the full heat output of all heaters is required to provide maximum recovery volume and thus reduced recovery times. In this case the pump must be sized to give a certain minimum flow rate through each heater. Selection data for the size of pump required is shown in the pump selection table overleaf. Pump Selection Table Pump selection using single or multiple units on a secondary return system (pump required for first unit only) (B249) Number Flow rate Approximate Speed of units required head setting 1 8 ltrs/min (0.13 ltrs/sec) 50kPa 2 Pump selection using multiple units with storage cylinder (flow through all units) 2 16 ltrs/min (0.27 ltrs/sec) 50kPa 2 3 24 ltrs/min (0.40 ltrs/sec) 60kPa 2 4 32 ltrs/min (0.53 ltrs/sec) 60kPa 3 5 40 ltrs/min (0.67 ltrs/sec) 60kPa 3 6 48 ltrs/min (0.80 ltrs/sec) 60kPa 3 Water Quality and Treatment In hard water areas, scale formation can occur in hot water systems and water heaters. The higher the temperature and volume of water used, the more problematic the scale build-up can be. Water treatment is highly recommended when the hardness reaches 100-150ppm (7-10 degrees Clark) and above. This problem can be minimised by reducing the water flow temperature or by fitting suitable water pre-treatment equipment. Please contact our Sales Department for further details.

Storage Cylinder Combination Secondary return 1. Strainer 2. Pressure reducing valve 6 Building flow 3. Non-return valve 4. Expansion vessel 5. Expansion valve 6. Temperature and pressure relief valve in tank 7. Tundish 8. Bronze circulator 1 2 3 4 5 8 Gas Remote control set to 70ºC 8 7 To drain STORAGE CYLINDER no burner or element Hot outlets* 3 3 Thermostat set to 65ºC Cold supply 7 To drain * The number of outlets is pictorial only and may vary Schematic diagram shows single WH/WHX unit with additional storage cyclinder, plus pipework and valve arrangement. Units should be pre-set to a minimum set point of 70ºC to maintain 65ºC flow from the cylinder. Please refer to the Andrews Design and Installation guide for further information. Andrews continuous flow water heaters can be combined with our range of ST storage cylinders to provide large volumes of hot water for peak flow use. This is especially useful in cases where the hot water flow rate requirement exceeds the flow capacity of the heaters for a limited period. Or where there is an intermittent large demand for hot water such as hospitals, hotels, apartments, sports changing rooms and health clubs. Storage Cylinder Details ST66 ST100 ST166 Capacity 300 ltrs 455 ltrs 755 ltrs Connection Rc1 1 2" Rc1 1 2" Rc2" Thermostat Connection Rc 3 4" Rc 3 4" Rc 3 4" Height 1492mm 1588mm 1981mm Diameter 610mm 711mm 813mm Weight Empty 95.2kg 141kg 245kg Weight Full 395kg 594kg 998kg Max pressure 10.3 bar 10.3bar 10.3bar

Specification Model (Natural Gas) WH42 WH56 WHX56 WHC56 Model** (Propane) LWH42 LWH56 LWHX56 N/A Heat input net 49.0 kw 62.3 kw 62.3 kw 54.0 kw Heat output net 42.0 kw 55.8 kw 55.8 kw 55.8 kw Gas rate natural 5.1m 3 /hr 6.5m 3 /hr 6.5m 3 /hr 5.1m 3 /hr Gas rate propane 1.9m 3 /hr 2.5m 3 /hr 2.5m 3 /hr N/A NOx emissions ppm 52ppm 52ppm N/A 60ppm NOx emissions mg/kwh 92mg/kWh 92mg/kWh N/A 105.84mg/kWh NOx emissions (propane) ppm N/A N/A 72ppm N/A NOx emissions (propane) mg/kwh N/A N/A 128mg/kWh N/A Noise Level db(a) 49 49 49 49 Water connection 3 4" BSP Gas connection (gas cock supplied) 3 4" BSP Efficiency 86% 90% 90% 103% Max water pressure 10.0 bar 10.0 bar 10.0 bar 10.0 bar Min water pressure*** 1.0 bar 1.0 bar 1.0 bar 1.0 bar Electric supply 230V 230V 230V 230V Frequency 50Hz 50Hz 50Hz 50Hz Fuse 5A 5A 5A 5A Max flow rate @ 25ºC rise 24 ltrs/min 32 ltrs/min 32 ltrs/min 32 ltrs/min Min flow rate 3.5 ltrs/min 3.5 ltrs/min 3.5 ltrs/min 3.5 ltrs/min Width 450mm 450 mm 450 mm 465 mm Height 615 mm 615 mm 615 mm 615 mm Depth 240 mm 240 mm 240 mm 240 mm Weight 29kg 29kg 30kg 29kg Flue Type Concentric Concentric External no Concentric 100mm 100mm Flue required 100mm ** L prefix propane models must be specified when ordering. *** Note:Although the heaters operate at low water pressure, maximum performance is not attained unless the incoming pressure is 2 bar or more. On pumped circulation systems a minimum flow of 8 litres/min through each heater is required for optimum performance. Water flow at different temperature rises Model (Natural Gas) 25ºC 35ºC 45ºC 55ºC 65ºC 1/sec 1/min 1/sec 1/min 1/sec 1/min 1/sec 1/min 1/sec 1/min WH42 0.4 24 0.29 17 0.22 13 0.18 10.8 0.15 9 WH56/WHX56 0.53 32 0.38 23 0.3 18 0.24 15 0.21 12 LWH42 0.4 24 0.29 17 0.22 13 0.18 10.8 0.15 9 LWH56/LWHX56 0.53 32 0.38 23 0.3 18 0.24 15 0.21 12 WHC56 0.53 32 0.38 23 0.3 18 0.24 15 0.21 12 0087 Publication Date: 0911 Baxi Commercial Division Wood Lane, Erdington, Birmingham B24 9QP Sales: 0845 070 1056 Technical: 0845 070 1057 Email: andrews@baxicommercialdivision.com www.andrewswaterheaters.co.uk