MICROGENUS HE WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILER. minimum space HIGH EFFICIENCY

Similar documents
WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

WALL-HUNG COMBINATION

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

WALL-HUNG COMBINATION

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

The iqe Boiler Range. Combination and System T Boilers.

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Our Boiler Family Our Boiler Family

A/23 MFFI - A/27 MFFI

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

Compact HRE Boiler Range. The smart choice for heating and hot water

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

The guarantee on this appliance is valid for 12 months from the first day of installation.

For latest prices and delivery to your door visit MyTub Ltd

ecotec plus New high efficiency condensing combination and system boiler ranges

Sirius FS. Working towards a cleaner future

turbomax plus High performance combination boiler range

1 VICTRIX ZEUS Superior kw I features

Baxi 600, 400 & 200 boilers. Range guide

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Condensing, pre-mixed, wall-hung gas boilers with water tank

thermocompact High performance system boiler range

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

The xi Range of High Efficiency Condensing Boilers. hxi Range 12-38kW

MAINTENANCE AND SERVICE GUIDE

ACCUMULATION OF EUROPEAN CLASS

ecomax pro High efficiency condensing boiler range for traditional systems

Residential Heating Boilers

C Tahiti. condensing

Ciao Green Condensing Wall-Hung Boilers

SPECIFICATIONS - NIKE

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

ENERGY TOP. Condensing boiler solutions

aquaplus High performance combination boiler with integrated power store

Duo-tec combi, Megaflo system and Solo heat only boilers. Range guide

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Our Boiler Family Our Boiler Family

New Zealand Sales Hotline: Sales Fax:

Installation and Servicing Instructions. Alpha CB50

DOMESTIC BOILER RANGE & ACCESSORIES.

Exclusive Green E Condensing Wall-Hung Boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Power X High Power Condensing Wall-Hung Boilers

Installation and Servicing Instructions. Alpha CD50

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

Power X High Power Condensing Wall-Hung Boilers

The mechatronics of EVE 05

PRODUCT CATALOGUE Issue 3 SYSTEM BOILERS COMBI BOILERS FLOOR STANDING BOILERS WATER HEATERS SPARE PARTS AFTER SALES SERVICE TRAINING

Light commercial products. High output boilers Cascade systems

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Compact 24 SE. Standard efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. GC No

Mynute Green Condensing Wall-Hung Boilers

E-COMBI EVO E-SYSTEM EVO

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Sirius WH. Working towards a cleaner future

CBX 24, 32 & 38 SBX 30

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Ideasandformsinevolution

Easicom. Quality, reliability, flexibility

Performa System 12e, 18e, 24e & 28e

microgenus II 24 MFFI microgenus II 28 MFFI microgenus II 31 MFFI Installation and Servicing Instructions Type C Boilers

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

A homeowner s guide to the Baxi Neta-tec Combi

HEAT ONLY & COMBI BOILER

NEW BUILD YOUR COMPLETE SOLUTION.

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Installation and Servicing Instructions. Alpha CD24C/32C

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Domestic heating solutions

Baxi Maxflow Combi WM

Alpha CD13R,18R and 24R

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Baxi Maxflow Combi FS

Installation, Servicing and Operating Instructions. Type C Boilers LEAVE THESE INSTRUCTIONS WITH THE END USER

InTec 2 X HIGH EFFICIENCY BOILERS LOW CARBON SOLUTIONS

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

Gas condensing boiler

Installation and Servicing Instructions. Alpha CD25C/28C/35C

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

VBX 18 & 30. Eden X Type INSTALLATION AND SERVICING INSTRUCTIONS OPEN VENT CONDENSING BOILER. SINGLE PAGES 20/9/10 09:58 Page 1

Installation Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS WITH THE END-USER

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

SERIES. Installation and Servicing Instructions Type C Boilers ACO 35 MFFI G.C.N: LEAVE THESE INSTRUCTIONS WITH THE END USER

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Transcription:

MICROGENUS HE WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILER minimum space HIGH EFFICIENCY

Compact, performance and reliability? Ariston in the UK Ariston is one of the main brands of the MTS Group, worldwide leaders in the production of central heating and hot water production appliances. Ariston (meaning the best, in Greek) was established in 1960; over the decades that have followed, the name has been given to a variety of domestic appliances. Ariston products are dedicated to design, simplicity and elegance enhancing and home comfort. Wider environmental concerns and green issues are addressed by research and development that continue to offer the most ecologically advanced products and services available. All Ariston products and production facilities are covered by a 'European corporate certificate' that certifies quality control procedures in line with ISO 9001 giving consumers peace of mind. The product portfolio covers domestic gas boilers, unvented cylinders and water heaters. The famous Ariston brand has a powerful market presence through an extensive network of builders and plumber merchants throughout the UK and Ireland. What are high efficiency boilers? A high efficiency boiler (also known as condensing) always extracts more heat from the combustion process and does not waste heat through the flue when compared to a standard efficiency (also known as noncondensing) boiler. A high efficiency boiler produces the same amount of heat output whilst burning less fuel and therefore creating less greenhouse emissions. High efficiency boilers burn gas in a traditional manner, but rather than losing energy in the form of high temperature gases from the flue, they recover that useful heat through the use of an enlarged primary heat exchanger or an additional heat exchanger. The extra surface area of the heat exchanger allows more heat to be extracted from the combustion process for the same amount of fuel that is used by a standard efficiency boiler. The system does not need to be designed to condense all the time to achieve improved efficiency; therefore it requires less fuel to apply the same amount of heat to the system when using a high efficiency boiler rather than a standard efficiency boiler. A high efficiency boiler is always saving on gas, money and reducing CO2 emissions. Legislation that will make the installation of high efficiency boilers compulsory in the majority of cases from April 2005 in order to reduce CO2 emissions throughout the UK has been introduced. CO2 is the major cause of global warming, adding to the greenhouse effect that is produced by burning fossil fuel. A central heating and hot water system in a typical household using a standard efficiency boiler will produce around 5 tonnes of CO2 a year. A high efficiency boiler s typical production of CO2 given the same factors is around 3 tonnes a year. Energy Efficiency Recommended is an Energy Saving Trust initiative backed by the government. The logo is only found on products that have been carefully selected for their energy efficiency. Buy where you see the sign and help save energy, money and the environment.

microgenus HE is the answer. - Domestic hot water (D.H.W.) temperature regulation knob - Central heating (C.H.) selector and temperature regulation knob - Economy/Comfort mode selector - Boiler reset button - Boiler ON/OFF selector knob - Display for: Auto-diagnostics Temperature Heating function Lock-out Holiday mode microgenus HE the user benefits 2-year guarantee extendable up to 5 years Energy Efficiency Recommended saving fuel and money Simple to use controls instant display of operational status Compact, space saving design Hot water on demand flow rates of up to 12.5 l/min Comfort switch pre-heat function guarantees hot water within seconds Easy-to-use mechanical time clock for central heating Reliable technology microgenus withstands the test of time When the microgenus range was first introduced it heralded a new era in central heating boilers. The microgenus was designed not only to be compact and offer high levels of comfort but also was launched with a 2-year guarantee. This parts and labour guarantee was not intended to be a gimmick but a true commitment to the level of quality and longevity incorporated in to the boiler. It is said that time will tell and this was certainly true for the microgenus as now it is one of the UK s best selling gas boilers and has scored favourably not only in terms of popularity but more importantly in reliability. But what happens when the 2-year guarantee is over? Simple, Ariston also offers a unique scheme that means the guarantee can be extended at the time of installation to 5 years in total and then annually for the life of the boiler; so simply microgenus offers total peace-of-mind.

microgenus HE from Ariston. microgenus HE the installer benefits 2-year guarantee SEDBUK Band B complies with latest regulations D.H.W. flow rates of up to 12.5 l/min Quick and easy installation Built-in mechanical time clock Filling-loop as standard Multiple flueing options maximum siting flexibility 10 reasons to choose microgenus HE Meets the latest requirements for High Efficiency boilers Virtually the same Three outputs to suit as microgenus II most situations Compact and light-weight 2 3 4 Needs just one extra connection 5 Complete selection of accessories available All inclusive package no hidden extras 6 7 Self-diagnostics 8 9 First-class back-up service Brilliant guarantee with flexible options for extending cover 1 10

Reassuringly Familiar. microgenus HE High Efficiency with a familiar face microgenus HE is SEDBUK Band B rated, it achieves this level of efficiency by incorporating an additional latent heat exchanger or recuperator, which significantly increases efficiency by extracting heat from the flue gases. The recuperator takes this heat, which is normally lost through the boiler flue, and uses this energy to pre-heat the boiler primary circuit water before it enters the main heat exchanger. This energy is usually wasted in standard efficiency boilers. The benefit of this is that it is based on existing technology and offers the installer a known boiler layout whilst meeting the requirement of the latest regulatory changes. 700 mm microgenus HE of course offers all the benefits of the microgenus range such as compact dimensions, builtin time clock, anti-frost device, by-pass and filling-loop as standard plus a myriad of flue and standard accessories making it one the most flexible and popular combi boilers available. In addition to the shared features above microgenus HE also features a condensate trap that is accessible from the outside of the boiler casing, thus eliminating the need for any disassembling for periodical maintenance. microgenus HE is simply the perfect solution for both the end-user and installer alike. 315 mm 400 mm

MICROGENUS HE 24 MFFI 28 MFFI 32 MFFI WALL-HUNG HIGH EFFICIENCY GAS COMBI BOILER ROOM SEALED COMBUSTION CHAMBER SEDBUK Band B - complies with latest Building Regulations Compact dimensions (700x400x315 mm) Available in 3 outputs of 23.3 kw - 79,500 Btu/h, 27.0 kw - 92,100 Btu/h or 30.5 kw - 104,000 Btu/h Fully modulating in C.H./D.H.W. with an accuracy to ± 1 C Auto-diagnostic system Comfort switch (pre-heat function) guaranteeing hot water at the outlet in seconds High D.H.W. flow rates up to 12.5 l/min (2.8 gal/min) (30.5 kw - 104,000 Btu/h) Anti-frost device Anti-scale device Anti seizing device for the pump Built-in automatic by-pass Built-in mechanical time clock Built-in condensate trap accessible from outside of of boiler casing. Coaxial flue system up to 4 m, twin pipe flue system up to 40 m Split exhaust and intake pipes for built-in combustion analysis Optional outdoor sensor: regulates the heating temperature automatically D.H.W. stainless steel plate heat exchanger guaranteed for 5 years 2 year manufacturer's guarantee Guarantee extendable up to 5 years This product has an energy rating of A on a scale of A-G for more information see www.sedbuk.com P.C.B. with microprocessor Automatic by-pass Highly Efficient Low NOx Electronic ignition Fully modulating C.H. Temp. adjustment D.H.W. temp. adjustment Insufficient system pressure shutdown MICROGENUS HE 24 MFFI MICROGENUS HE 28 MFFI Combustion analysis device CLEARANCE DIMENSIONS - PIPE FITTINGS - EXHAUST OUTLETS A Central heating flow 22mm copper tail 22mm copper tail Anti-frost device IP24D B Domestic hot water outlet 15mm copper tail 15mm copper tail C Gas inlet Anti-scale device 15mm copper tail 15mm copper tail D.H.W. plate heat exchanger D Domestic hot water inlet 15mm copper tail 15mm copper tail Integral auto-diagnostics E Central heating return 22mm copper tail 22mm copper tail Outdoor sensor (optional) F Flue (Ø mm) F1 60/100, 80/125 F2 80 F1 60/100, 80/125 F2 80 MICROGENUS HE 32 MFFI 22mm copper tail 15mm copper tail 15mm copper tail 15mm copper tail 22mm copper tail F1 60/100, 80/125 F2 80 Coaxial exhaust Twin pipe exhaust

TECHNICAL DATA MICROGENUS HE 32 MFFI 24 MFFI 28 MFFI 32 MFFI EFFICIENCY SEDBUK rating band B B B SAP efficiency % TBC TBC TBC POWER & PERFORMANCE Heat input min. (net) kw-btu/h 12.2-41,600 13.3-45,400 13.3-45,400 Heat input max. (net) kw-btu/h 26.7-91,100 31.1-106,100 35.0-119,400 Heat output min. kw-btu/h 10.4-35,500 11.4-38,900 11.3-38,600 Heat output max. kw-btu/h 23.3-79,500 27.0-92,100 30.5-104,000 Central heating temp. max. (high temp.) C 82 82 82 Central heating temp. min. (high temp.) C 42 42 42 Central heating temp. max. (low temp.) C 44 44 44 Central heating temp. min. (low temp.) C 38 38 38 D.H.W. temperature maximum C 56 56 56 D.H.W. temperature minimum C 36 36 36 D.H.W. flow rate T =35 C l/min 9.5 11.0 12.5 D.H.W. flow rate T =35 C gal/min 2.1 2.4 2.8 CHARACTERISTICS Consumption at nominal capacity G20 (1) m 3 /h 2.54 2.98 3.33 Exhaust gas temperature at nominal capacity C 72 65 64.5 Minimum ambient temperature C 5 5 5 Pressure loss through boiler (max) ( T=20 C) mbar 200 200 200 Residual head of system bar 0.25 0.25 0.25 D.H.W. minimum flow rate l/min 2.5 2.5 2.5 Domestic hot water pressure maximum bar 6 6 6 Domestic hot water pressure minimum bar 0.2 0.2 0.2 Built-in expansion vessel capacity l 7 7 7 Built-in expansion vessel pre-charged vessel bar 0.7 0.7 0.7 Maximum water content of system l 130 130 130 Maximum heating pressure bar 3 3 3 Gas inlet pressure - Natural Gas (G20) mbar 20 20 20 Servicing clearances - top/front/bottom mm 250/450/200 250/450/200 250/450/200 Servicing clearances - left/right mm 35/35 35/35 35/35 Zero compartment ventilation Yes Yes Yes Weight kg 37 38 39 G.C. number 47-116-37 47-116-38 47-116-39 ELECTRICAL DATA Electrical supply V/Hz 230/50 230/50 230/50 Power consumption W 120 140 165 Protection grade of electrical system IP X4D X4D X4D Internal fuse rating FAST 2 AT FAST 2 AT FAST 2 AT (1) :15 C, 1013 mbar Flue connector Air intake (Twin flue) Air pressure switch Fan Combustion chamber hood Main heat exchanger Safety thermostat C.H. flow temperature probe Combustion chamber Detection electrodes Ignition electrodes Motorised diverter valve Insulated secondary heat exchanger DHW temperature probe Pump pressure switch Gas valve Spark generator DHW flow switch Combustion analysis intake Latent heat exchanger (recuperator) Venturi tubes Expansion vessel C.H. return temperature probe Burner 3 bar safety valve circulation pump with automatic air release valve SCHEMATIC mbar 600 Graph of boiler residual head ROOM-SEALED FAN FLUE 24 MFFI - 28MFFI - 32 MFFI 500 400 2 1 300 200 100 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 flow rate l/h 1-24 kw model 2-28 & 31 kw models Simplified Coaxial system coupling Separation of the air intake Access to air pressure switch

FLUE PIPE ACCESSORIES - EASY INSTALLATION WITH UNRIVALED FLEXIBILITY Ariston boilers are designed to be completely adaptable to every possible flue situation that may be encountered in boiler installation. The need for alteration to flue components is almost completely eliminated, making installation of the boiler quick and easy. It is possible to site flue terminals in a variety of positions in accordance with BS5440-1:2000. INSTALLATION CONDITIONS TERMINAL POSITION mm A Directly above/below an opening, air brick, opening windows, etc 300 B Horizontally to an opening, air brick, opening windows, etc 300 C Below gutters, soil pipes or drain pipes 75 D Below eaves 200 E Below balconies or car port roof 200 F From vertical drain or soil pipe 150 G From an internal or external corner 300 H Above ground roof or balcony level 300 I From a surface facing the terminal 600 J From a terminal facing the terminal 1200 K From an opening in the car port 1200 (e.g. door, window) into the dwelling L Vertically from a terminal on the same wall 1500 M Horizontally from a terminal in the same wall 300 N Fixed by use of terminal and matched flashing plate -

0 1 Coaxial system: up to 4 m (60/100) - (80/125) TBC Twin pipe system up to 40 m TYPE 1 Coaxial System TYPE 2 Coaxial System Vertical installation with coaxial piping on a flat roof. Vertical installation with coaxial piping on a pitched roof. TYPE 3 Coaxial System TYPE 4 Twin pipe system TYPE 5 Twin pipe system TYPE 6 Twin pipe system Horizontal installation with coaxial piping. Installation with two separate pipes - exhaust on a pitched roof, air inlet through a wall. Installation with two separate pipes - exhaust and air inlet on a pitched roof via a coaxial adaptor. Installation with two separate pipes - exhaust via flue duct, air inlet through a wall. COAXIAL FLUE ACCESSORIES Horizontal installation with coaxial piping. OUR REF. DESCRIPTION COAXIAL 60/100 3318073 Horizontal coaxial kit - 1000mm 3318074 Horizontal coaxial kit 3318075 90 o Coaxial Elbow 3318076 45 o Coaxial Elbow (pack of 2) 3318077 Coaxial Extension - 1000mm 3318078 Coaxial Extension - 500mm 3318079 Vertical starter 3318080 Vertical flue with black terminal 3318081 Vertical flue with red terminal COAXIAL 80/125 3318090 Horizontal coaxial kit + adaptor 80/125 3318091 90 o Coaxial Elbow 80/125 3318092 45 o Coaxial Elbow 80/125 3318093 Coaxial Extension 80/125-1000mm 3318094 Coaxial Extension 80/125-500mm 3318095 Adaptor 60/100-80/125 TWIN PIPE FLUE ACCESSORIES OUR REF. DESCRIPTION TWIN PIPE 3318082 Adaptor (Ø 60/80) 3318083 Horizontal twin pipe systems 3318084 90 o MF Elbow (Ø 80) 3318085 45 o MF Elbow (Ø80) (pack of 2) 3318086 Extension (Ø 80) - 1000mm 3318087 Extension (Ø 80) - 500mm 3318088 Adaptor 80/125-80 3318089 Adaptor 80/125-80+80 SUNDRY ITEMS 3318009/3318010 Lead Flashing Base Cap Black/Red 3318011/3318012 Vent Cap Base for Flat Roof Black/Red 3318015 Wall Bracket Kit (Ø 80 - Ø 125)

ACCESSORIES AND SPARE PARTS ENGINEERED FOR PERFECT INSTALLATION JIG-KIT (Supplied within the boiler as standard) The jig-kit makes installation easier because it allows you to fill the system even without the boiler fitted. It is equipped with 4 isolation valves: 2 for the heating circuit, 1 for the domestic water system and one for the gas. The system return isolation valve can be connected to the system cleaner using the cap provided. The bracket that holds the valves can be positioned in two ways depending on whether installation is with or without the rear-piping chassis, and allows small adjustments for irregular walls. The kit is supplied with: double non-return valves on the filling loop for filling the system. Copper tail pipes to ease soldering to the system piping. SYSTEM CLEANER - 705998 A practical accessory for cleaning the heating system. It is simple to use: connect the system cleaner to the system return isolation valve, open the system return isolation valve, switch on the boiler, allow the pump to run for the necessary time then remove the system cleaner from the kit. The filter provided is made up of a removable cartridge which absorbs any impurities in the system. This allows the flushing of a new heating system without the impurities damaging the boiler components. The system cleaner can also be used to add chemical additives such as cleansers and inhibitors. REAR-PIPING CHASSIS - 706190 Allows easy installation in situations where the system pipes are required to run up the rear of the boiler. The rear-piping chassis consists of a bracket on which the boiler is hung, this has two flanks that extend the side panel of the boiler chassis. Assemble by just bringing forward the valve kit and connecting the pipes. The rear-piping chassis kit includes the pipe work elements for connection to the system.

ANTI-THEFT DEVICE - 705982 Protects the boiler from theft and can be assembled in two ways: with or without the rear-piping chassis. The simple assembly instructions are included in the jig-kit and on the anti-theft device itself. LPG CONVERSION KIT - 998717 (Not illustrated) This kit enables the conversion of a standard Natural Gas version of the microgenus HE to be used with LPG. The kit includes burner injectors and gas type identification label. JIG-KIT COVER - 706346 To conceal the pipe-work or jig-kit below the boiler a specially designed cover is available. The cover is simply and easily mounted to the bottom of the boiler. DIGITAL TIME CLOCK - 706348 The addition of a 7 day digital time clock allows the user to program the central heating to operate in conjunction with their lifestyle and weekly routine. It is possible to set the boiler to turn on and off up to 20 preset times during the week: allowing users to differentiate setting between weekdays and the weekend for example. It is also possible to override the automatic settings and operate the boiler manually at any time. OUTDOOR SENSOR - 3318059 (An optional accessory to optimise comfort and efficiency) The microgenus HE outdoor temperature sensor kit can increase both comfort and energy efficiency. The sensor and interface PCB works in conjunction with the advanced microprocessor to monitor outside temperatures and conditions assessing the thermal power requirements. Increasing power when cold, decreasing power when warmer therefore increasing overall system efficiency.

ARISTON QUALITY PRODUCTS EXCEPTIONAL SERVICE Month & Year Printed by Vario Press REGIONAL TRAINING CENTRES Plymouth High Wycombe Gt. Manchester COMPREHENSIVE TRAINING Training courses are available across the entire Ariston range including all the necessary theory and practical aspects. The courses are open to any CORGI Registered installer or engineer at fully equipped training centres in High Wycombe, Plymouth and Golbourne (near Wigan) and other venues up and down the country. The courses on offer include boiler installation, maintenance and servicing and unvented domestic hot water systems. TECHNICAL ADVICE Immediate and effective technical assistance is only a phone call away. Including advice as to which product is most suited to your needs and the requirements of your system installation. Our skilled team is also trained to talk you through the trickiest problems that might crop up during an installation and answer the most obscure technical questions you could possibly think of. http: for the latest product info visit: www.ariston.co.uk CUSTOMER SERVICE Ariston offers unrivalled customer service; in the unlikely event of a problem with an Ariston appliance all of our Customer Services team are trained to deal with any situation swiftly and to offer advice where possible. Should it be necessary for an engineer to call a specially trained technician will soon be on hand, prepared for most eventualities. In the interests of our customers, MTS (GB) Limited is continually developing these products to improve both performance and design. We therefore reserve the right to change specification without prior notice. This brochure is accurate at the date of printing. Consumer statutory rights are not affected. MTS (GB) Limited MTS Building Hughenden Avenue High Wycombe Bucks, HP13 5FT Tel: 01494 755600 Fax: 01494 459775 Technical Advice & Customer Service Fax 01494 463066 technical@uk.mtsgroup.com info@uk.mtsgroup.com