VITALink. FAQs I. GENERAL QUESTIONS

Similar documents
Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

Comtran Cable. Hub-LINK Cables for Transit Applications

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

Surviving the Survivable Cable Crunch

Questions/Comments for Richard Roux from Webinar on 7/11/13

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

CommerciaL fire-rated

Fire Alarm Wiring. Circuit types, styles and limitations

2018 NICET Code Transition Changes

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Fire Alarm System Fundamentals

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

NewGeneration Cables. BELDENCable TM

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Osceola County Department of Fire Rescue and Emergency Medical Services

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Solutions for Mass Notification Systems

Article by: Ark Tsisserev, Principal, Stantec Consulting Ltd.

CONNECTION SYSTEMS TRANSIT APPLICATIONS

SIGA-CC1 Single Input Signal Module Installation Sheet

Print Specification. Publication. Instructions. Specific requirements. General requirements

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Fire Protection Coffee Break Training May 2016

Fire Alarm, Water Flow Alarm & Signaling Systems

Hospital Fire Alarm Systems Recurring Misapplications and Misused Requirements

Welcome to the AccessibilityOnline Webinar Series. Listening to the Webinar. Listening to the Webinar, continued

Winnipeg Fire Department Fire Prevention Branch

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

The Cannabis Industry: Fire Department Requirements

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Welcome to the AccessibilityOnline Webinar Series. Listening to the Webinar

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

Fire Resistant Cables - Update Alan Cavers Engineering Manager Certificate Services Group

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

Applying Performance-based Fire Alarm System Design Part 4

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

MODULE 8. Tying the Systems Together: Emergency Control Functions and Interfaces

Advanced Fire Alarm Systems Training Program Outline (5 Day)

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

Graphic Products,

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures


Fire Safety in Tall Building: Performance-Based Solutions. Chris Jelenewicz, P.E., FSFPE

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Second Revision No. 601 NFPA [ Section No [Excluding

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

Preview of the MA Building Code (780 CMR) 9 th edition

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Related Sections: TBD. Effective Date: January 1, 2016

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

Maintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Are Electric Cables my biggest Fire Risk?

WHITE PLAINS SMOKE CONTROL CODE PART 1. GENERAL REQUIREMENTS

BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

Some information I have read tells me to evacuate immediately in case of fire. Fire In Your Residential Building. To Go?? To Stay??

Fire Alarm/Life Safety Cable 6

NEC 2017 Changes and Their Effect Upon the ICT Industry

TrueAlarm Analog Sensing

Drexan Energy Systems Inc.

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

PHOTOLUMINESCENT EXIT SIGNS EVALUATED AND TESTED TO UL924

JESSUP JESSUP. GLO BRITE EXIT AND EGRESS Photoluminescent signs and tapes. Adhesive Coated Films. Adhesive Coated Films. Jessup Manufacturing Company

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Overview of Fire Alarm Provisions Based on the 2012 IBC, IFC and NFPA 72, 2013 Edition

Fire Inspection Frequently Asked Questions

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

First Revision No. 339-NFPA [ Section No. 2.2 ]

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

Transcription:

I. GENERAL QUESTIONS 1) Why do I need to use Circuit Integrity cables? Circuit Integrity cables are utilized to protect critical emergency circuits and maintain operability of fire alarm system in order to ensure adequate egress time and first responder safety during fire conditions. Pathway survivability is necessitated both by code and engineering risk analysis and varies according to each location circumstance. Generally, it is used in large and/or high occupancy structures that require partial evaluation or relocation in event of a fire. If you would like to learn more about the What, Where, When and Why of CI, please contact sales@comtrancorp.com to schedule a webinar or on-site training. 2) Where do I need to use Circuit Integrity Cables? A. Typical locations a. High-rise buildings b. High occupancy buildings (places of assembly, i.e. stadiums, casinos, airports, etc) c. Hospitals and health care facilities d. Hotels, universities, government buildings e. Tunnels and subways B. Common applications: a. EVAC Emergency voice-alarm communications, smoke & fire alarm systems b. Area of Refuge and Fireman s Telephone c. Fan/Damper pressurization systems d. Command center critical operations e. Mass notification f. Elevator occupant evacuation operation 3) What s the difference between CI and CIC? VITALink cables are dual rated CI and CIC one cable qualified to UL 2196 for two different installation scenarios. CI for free air installation is a conduit-free solution for riser and horizontal (non-plenum) installations per NEC Code 760.24. CIC is a circuit integrity system that includes the physical protection of conduit and is installed per UL FHIT 40A. Please consult your local AHJ for local code enforcement. 4) What are the NFPA code applications? NFPA 70 - National Electrical Code NFPA 72 - Fire Alarm & Signaling Code NFPA 130 Fixed Guideway for Transit and Passenger Railway Systems NFPA 502 - Road Tunnels, Bridges, and Other Limited Access Highways

2 5) Where can I access a specification? Please visit our website at www.comtrancorp.com 6) Where can I purchase this product? Product is sold through our distribution partners. Please contact us at 800-842-7809 or email sales@comtrancorp.com 7) What are the benefits of VITALink over other 2-Hour Fire Rated cables? VITALink features: The MOST versatile choice one cable, dual CI/CIC listing The BEST conduit fill in the industry The LONGEST vertical distance The BEST product spectrum The MOST comprehensive listings and BEST ratings 8) What are the benefits of VITALink over alternative 2-Hour Fire Rated methods? Requires no special tools, connectors, or certification for installation Ease of installation installs like standard cable; product is flexible and comes in long lengths Lower installed costs Readily available no lead time; stocked at partner locations throughout North America II. INSTALLATION & TECHNICAL QUESTIONS 1) Where can I find the manufacturer s installation instructions when cables are being installed in conduit (CIC)? Please visit our website at www.comtrancorp.com 2) What are the installation instructions when cables are being installed as CI for free air? Installation is per the NEC code Article 760. 3) Do installers need special tools, training, or certification? No, any licensed contractor/integrator can install our cable with normal cable installation tools.

3 4) Are there specific branded components that need to be utilized with the system when installed as CIC? Why? Hardware requirements can be found in the FHIT document and the manufacturer s installation instructions Specific components utilized to pass the UL 2196 qualifying become part of the assembly listing to ensure control and compatibility of materials required to maintain the listing. VITALink has the most versatile conduit selection, with both EMT and IMC certified. EMT brands include Allied Tube & Conduit Corp., Wheatland/Western Tube Co. and Columbia-MBF. IMC brands include Allied Tube & Conduit Corp. and Wheatland/Western Tube Co. Using non-approved hardware will nullify the circuit integrity rating; always check with the AHJ for exceptions 5) Why not get approvals for alternate brands of components? Any product or changes/additions in the assembly components or procedures requires extensive re-testing at UL. 6) Can cables be installed in rigid conduit? No, see above. 7) Tell me about approved pull boxes System is approved with Wiegmann brand NEMA rated boxes. Wiegmann is manufactured by Hubbell. Recommendations for box sizes can be found in the manufacturer s installation instructions 8) Tell me about conduit fill The conduit fill chart can be found on the FHIT document and manufacturer s installation instructions. VITALink has the best conduit fill in the industry. All constructions allow up to 10 cables in a 2 conduit with exception of 18 AWG which is 7 cables in a 2 conduit. 18 AWG is less because it is more difficult to pass the test with a smaller AWG size. When combining 18 AWG with other constructions, limitation defaults to the most stringent. Conduit fill is the same for both vertical and horizontal constructions. Conduit fill takes into account max NEC fill ratios of 40%. 9) Can I put shielded and non-shielded in same conduit? Yes

4 10) Can I install other types of cables in the same conduit? No, only cables and components tested and approved through the UL 2196 test may be utilized. Adding additional building wire or communication cables will have an unpredictable effect on the ability of the fire rated cable to operate in case of a fire, which would jeopardize the 2-hour rating. 11) Can I use condulets for installation? No, condulets are not recommended unless allowed by the AHJ. 12) Can VITALink cables be spliced? Yes, we have an approved splicing procedure which can be accessed on our website at www.comtrancorp.com III. APPROVAL & RATING QUESTIONS 1) Where can I find the UL 2196 FHIT sheet? Our FHIT sheet is #40A. It can be accessed through the UL Directory at: http://www.ul.com/code- authorities/fire-code/fire-resistive-and-circuit-integrity-cables/ or by visiting our website at www.comtrancorp.com 2) Is VITALink approved for use in Canada? Yes, however it must be installed in conduit per the Canadian Electric Code CAN/ULC-S139 Certified with Hose Stream Test for use in FHIT7 system 40A CEC and CSA listed FAS 90 to C22.2 No. 208-14 3) Is VITALink approved for use in New York City? Yes, Comtran has obtained formal approval #54502 from the NYC Electrical Advisory Board authorizing use in New York City. 4) Is VITALink approved for use in California? Yes, VITALink is approved by the California State Fire Marshal listings numbers: 7161-1295-0100 7160-1295-0101 7160-1295-0102 5) Is VITALink Riser and/or Plenum Rated? VITALink cable is FPLR rated and achieves a plenum rating when installed in conduit.

5 6) Is VITALink wet rated? Yes, all VITALink cables may be installed in damp locations (such as basements and tunnels), however it is not designed for prolonged submerged use. 7) Is VITALink sunlight resistant? Yes 8) What is the temperature rating? The temperature rating of 105 C is the best polymeric two hour fire rated cable in the industry. 9) Is VITALink Low Smoke, Zero Halogen? Yes, the outer jacket is a LSZH polyolefin compound. IV. OTHER RESOURCES Contact us or visit our website for additional assistance and resources: UL FHIT.40A and FHIT7.40A Manufacturer s installation instructions Splicing guide