Technical Data 04/2005 UK VOGEL & NOOT. compactradiator VOGEL & NOOT. Wärmetechnik

Similar documents
PANEL RADIATORS DESIGN RADIATORS TOWEL WARMERS.

VERTICAL VONOVA & VERTICAL VONOPLAN. 20 VERTICAL VONOVA & VERTICAL VONOPLAN PANEL RADIATORS. VERTICAL VONOVA Type 20. VERTICAL VONOPLAN Type 20.

T6 - Centrally Connected & VONOPLAN T6.

30 VIENNARAIL DESIGN RADIATORS & TOWEL WARMERS VIENNARAIL.

planal vertical The ultimate modern statement room, Planal Vertical radiators and exciting, flexible way to make an impression

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

Buying goods/services

Corrosion Resistant Fluid and Air Handling Systems.

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

UEA BROADVIEW LODGE TERMS AND CONDITIONS Any variation to these standard terms and conditions must be agreed in writing with UEA Broadview Lodge. 1.

LOW SURFACE TEMPERATURE RADIATORS

Security Alarm Monitoring Agreement

INSTRUCTION MANUAL HS-229G

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

- User Brochure tekmarnet 4 Setpoint Control 161

Heating Emitters. Find the right radiator for each room. Radiators Towel Warmers Towel Warmer Valves 295

Model PT-05 Model PT-06

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

3RD GENERATION PANEL RADIATORS

Air Pump Up to 800 gallons

PLAN KLASIK LINE KLASIK

Pressurized Filter Up to 1250 gallons

Installation & Operation Manual

Model pictured: ST6001

LST i PLUS. Safety Series

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

FTTN Business Readiness Testing Special Terms

AUTOMATIC FIRE ALARM MONITORING

Automated Fire Monitoring New Connection Contract Customer to Complete Page 1 and 2

Power flushing and protecting your heating system can increase efficiency by at least 25%.

LST Plus Vertical. Plus Vertical 3 models. Lengths: 560mm, 660mm & 760mm. Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr

CD6102 / CD6102 OC / CD6102-2

- User Brochure Programmable Thermostat 510

Dene Bath Shower Mixer

General Terms and Conditions of Use of the Wacker Neuson WebEDI Portal for Suppliers (Last Update: July 1 st, 2018)

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Bath Shower Mixer

Advokatfirmaet BAHR AS - ENGAGEMENT TERMS

Installation and Operations Manual

EB Mawson & Sons Pty Ltd Trading as Mildura Mini Mix and Garden Supplies

Cast Iron Radiators. General Information 2. Block make up 6.

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07)

User's Manual. and Warranty Information. ThyssenKrupp. ThyssenKrupp Access

Model pictured: ST3701

Studio Mug. Operators Handbook. Rev A - 24/08/ a.adkins and sons limited. all rights reserved

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

DIGITAL STEEL FIRE & SECURITY

3.2 If there is an inconsistency between the documents forming the CSA, specific requirements will prevail over general requirements.

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

AGREEMENT FOR THE PROVISION OF FIRE ALARM MONITORING SERVICES AND EQUIPMENT

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

LST STANDARD. Safety Series

STAINLESSLITE PLUS BUFFER STORE

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

First Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts)

Model pictured: ST7001SLIM/ST7001SLIMA

Active Thermal Management. SEC-1 Installation Instructions

Sovereign Double CC/DD

CPL Series Pedestal Convection Heater

DESIGNER RADIATORS.

MILLI CUBE HEATED TOWEL RAIL 825 X 600

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

General Terms and Conditions of Pillow s Willow VR Studios B.V.

Preamplifier Power Supply PPS-02 user's guide

STAINLESSLITE PLUS BUFFER STORE

ion Genesis Pump Controller

INSTALLATION GUIDE AND WARRANTY INFORMATION

CONDENSING WATER BOILERS. (Models VLT , Q VX ,

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

PANEL RADIATOR RANGE. inside

636 and 646 Keypads. User s Manual

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

2018 Canadian Price List

BOARD OF COUNTY COMMISSIONERS

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

installation, operation & Maintenance manual Floor-mounted Induction units

DFG200-3 COMPACT FLOOR GRINDER. Operating Manual

DIGITAL STEEL FIRE & SECURITY

Developer, new connection and infrastructure charges

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

UBBU60LFA. Built-under Fridge Manual for Installation, Use and Maintenance IM UBBU60LFA_

The Series LFII (TY3596) Residential

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

XT Series Thermostats

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

PhoneWatch Install, Monitoring & Service Terms and Conditions

Compact Equipment Warranty Policy

WHE 2.24 / WHE 2.24 FF

K Series (Model A) Fan Forced Wall Heaters

Transcription:

Technical Data 04/2005 UK VOGEL & NOOT radiator VOGEL & NOOT Wärmetechnik

Compact Range General The Vienna Line radiator series is of an advanced high efficiency design and comprises of 3 radiator-types K1SPG, P+ and K2 each in 5 heights except P+ - 300, 400, 500, 600 and 750 mm. Radiator lengths from 400 3000 mm are available. The types are as follows: Type K1SPG Type P+ Type K2 single panel & convector surface plus side panels & top grill double panel & one convector surface plus side panels & top grill double panel & two convector surfaces plus side panels & top grill The heat output figures for the 300 mm, 400 mm, 500 mm, 600 mm and 750 mm high radiators have been derived from calculations which conform with the requirements of BSEN 442: 1997. BS Kitemark The Vogel & Noot Vienna Line range is manufactured and tested in accordance with BSEN 442: 1997 via a factory Quality System certified as meeting the requirements of BSEN ISO 9002: 1994. All radiators therefore carry the BSI KITEMARK which certifies the heat output figures contained in this leaflet and verifies the technical excellence of the product as well as the maintenance of high production quality standards. Appearance On types K1SPG, P+ and K2 the top grill and side panels are included in the price. Every Vienna Line radiator is subjected to a thorough painting process involving degreasing, phosphating and primer coating (stoved) prior to the final finishing coat of white semi-gloss epoxy paint, which is cured at 210 C. This means that Vienna Line radiators can be installed without further painting, although if desired (e.g. colour change), overpainting can be carried out using a good quality, oil-based gloss paint. Additionally, white touch-up paint is available. Pressures Every VN radiator is tested to a pressure of 13 bar (189 psi). Working pressures 10 bar (145 psi) are therefore acceptable. Packaging Each VN radiator is individually wrapped in heavy duty polythene shrink-wrapping, being clearly marked externally with type and size. Corners are additionally well protected with preformed caps, the radiator panel itself also being wrapped in cardboard. The packaging is so designed as to enable full fitting and assembly of radiators into the heating system, without removing the protective packaging - a real plus point for new building installations. Additionally, radiators left protected in this way can be filled and run 40 deg C during initial cleaning and commissioning of the heating system. The wall fixing brackets, blanking plug, air vent plug and vent key are supplied packed with each radiator. Application For use on indirect or closed circuit heating systems only, which have been properly designed and installed in accordance with the recommendations of BS 5449. In open-vented systems, special attention should be paid to the correct location of the pump in relation to the cold feed and vent pipe connections, to avoid ingress of air or water discharge through the open vent. Heat Emission Data The Vienna Line range is of an advanced design giving high efficiency characteristics. The high outputs per unit surface area for the convector models have been achieved by ensuring excellent contact between the convector plates and both the water channels and dividing metal of the radiator panels - see fig. 1. The convector surface is spot-welded to the metal channels, but also firmly locates into grooves on the water channels, thus ensuring high heat transfer rates. fig.1 Tappings and Fittings Each VN radiator has 4 x 1 2" BSP tappings as standard, allowing maximum flexibility of connection. Each radiator is supplied complete with wall fixing brackets, blanking plug, air vent plug and vent key. 2

Types available K1SPG P+ K2 61 80 7 105 7 einlagig mit einem Konvektionsblech zweilagig mit einem Konvektionsblech zweilagig mit zwei Konvektionsblechen 32 23 47 59 Type K1SPG P+ K2 Heights [mm] 300 400 500 600 750 300 500 600 750 300 400 500 600 750 Tapping Centres 246 346 446 546 696 246 446 546 696 246 346 446 546 696 Mounting Lug Centres 120 220 320 420 570 120 320 420 570 120 220 320 420 570 Lengths [mm] 2600 2200 2600 Steps all dimensions start at 400 mm graded 200 mm; plus 520, 720, 920, 1120 and 1320 mm right Richtig Stau Falsch wrong OA T T + 10 % = OA 3

Mounting Lug Positions - All Radiator Types The brackets supplied are suitable for mounting all types of radiators of the same height. X Y X The diagrams below are based on the wide flange being fixed to the wall. 110 40 Plastic Insert 40 Radiator Measurement X mm K1SPG 93 P+ 100 K2 100 70 Baulänge Length Overall length Measurement Y = for all radiators 2 with an overall length of 1800 mm and above. Radiator Bracket System Type K2 Type P+ Type K1SPG Height nominal mm A in Dimensions mm B in 12 300 11 13 / 16 145 5 11 / 16 16 400 15 3 / 4 254 10 20 500 19 11 / 16 345 13 9 / 16 24 600 23 5 / 8 445 17 1 / 2 30 750 29 1 / 2 595 23 7 / 16 64

Water Content in Litre/m length Heigth [mm] Type 300 400 500 600 750 K1SPG 2,0 2,6 3,3 3,7 4,4 P+ 3,9 5,0 6,1 7,1 8,6 K2 3,9 5,0 6,1 7,1 8,6 Warranty When used in systems designed and installed in accordance with the good practice recommendations given in the previous Application and Installation sections, each VN radiator is guaranteed for 5 years from date of installation. However, failure to pay proper attention to these recommendations (in new or existing systems) will invalidate the manufacturer s warranty. Installation All installation work should be carried out in accordance with recognised good practice to ensure long life. In particular, pay careful attention to the following: Soldered joints should be made with a minimum amount of solder and flux. Choose a flux which is readily soluble in water. Copper pipes should be cut and cleaned in such a way as to avoid small copper particles being left in the system (this can lead to electrolytic action and eventual corrosion in the radiator). Corrosion inhibitors should be used strictly in accordance with the manufacturer s instructions. Installation instructions for the radiators themselves are supplied in each radiator package. 5

Delta T 60 Heat outputs to BSEN 442 CERTIFICATION Heat outputs based on a mean radiator water temperature of 80 C and room temperature of 20 C Delta T 60. height (mm) 300 400 500 600 750 Model length (nominal) mm in secs 400 15.7 10 K1 SPG P+ K2 output 290 429 564 363 699 432 636 824 498 729 940 592 862 1108 Watt 988 1464 1926 1239 2386 1473 2168 2812 1698 2487 3208 2022 2943 3780 Btu/h 520 20.4 13 600 23.6 15 720 28.3 18 800 31.5 20 920 36.2 23 1000 39.4 25 1120 44.1 28 1200 47.2 30 1320 52.0 33 1400 55.1 35 1600 63.0 40 1800 70.9 45 78.7 50 2200 86.6 55 2400 94.5 60 2600 102.4 65 2800 110.2 70 3000 118.1 75 376 558 734 472 909 561 826 1071 647 947 1222 770 1121 1440 Watt 1285 1904 2504 1610 3102 1915 2819 3656 2208 3233 4170 2629 Btu/h 434 644 847 544 1049 647 953 1236 746 1093 1410 889 1294 1661 Watt 1483 2197 2890 1858 3579 2209 3253 4218 2548 3730 4811 3033 4415 5670 Btu/h 521 773 1016 653 1259 777 1144 1483 896 1312 1692 1066 1552 1994 Watt 1779 2636 3468 2230 4295 2651 3903 5062 3057 4476 5774 3640 5298 6804 Btu/h 579 858 1129 726 1398 863 1271 1648 995 1458 1880 1185 1725 2215 Watt 1977 2929 3853 2478 4772 2946 4337 5624 3397 4974 6415 4044 5886 7560 Btu/h 666 987 1298 834 1608 993 1462 1895 1144 1676 2162 1363 1984 2547 Watt 2273 3368 4431 2849 5488 3387 4987 6468 3906 5720 7377 4651 6769 8694 Btu/h 724 1073 1411 907 1748 1079 1589 2060 1244 1822 2350 1481 2156 2769 Watt 2471 3661 4816 3097 5965 3682 5421 7030 4246 6217 8019 5055 7358 9450 Btu/h 811 1202 1580 1016 1958 1208 1780 2307 1393 2041 2632 1659 2415 3101 Watt 2768 4100 5394 3469 6681 4124 6072 7874 4756 6963 8981 5662 8241 10584 Btu/h 869 1288 1693 1088 2098 1295 1907 2472 1493 2186 2820 1777 2587 3323 Watt 2965 4393 5779 3716 7158 4418 6505 8436 5095 7460 9623 6066 8830 11340 Btu/h 956 1416 1863 1197 2307 1424 2097 2719 1642 2405 3102 1955 2846 3655 Watt 3262 4833 6357 4088 7874 4860 7156 9280 5605 8206 10585 6673 9713 12474 Btu/h 1014 1502 1975 1270 2447 1511 2225 2884 1742 2551 3290 2073 3018 3877 Watt 3459 5125 6742 4336 8351 5155 7589 9842 5944 8704 11227 7077 10301 13230 Btu/h 1158 1717 2258 1451 2797 1726 2542 3296 1990 2915 3760 2370 3450 4430 Watt 3954 5858 7706 4955 9544 5891 8674 11248 6794 9947 12830 8088 11773 15120 Btu/h 1303 1931 2540 1633 3146 1942 2860 3708 2239 3280 4230 2666 3881 4984 Watt 4448 6590 8669 5575 10737 6628 9758 12654 7643 11191 14434 9099 13244 17010 Btu/h 1448 2146 2822 1814 3496 2158 3178 4120 2488 3644 4700 2962 4312 5538 Watt 4942 7322 9632 6194 11930 7364 10842 14060 8492 12434 16038 10110 14716 18900 Btu/h 1593 2361 3104 1995 3846 2374 3496 4532 2737 4008 5170 3258 4743 6092 Watt 5930 10595 8100 11926 15466 9341 13677 17642 Btu/h 1738 2575 3386 2177 4195 2590 3814 4944 2986 4373 5640 3554 5174 6646 Watt 6425 8786 11558 7433 14316 8837 13010 16872 10190 14921 19246 12132 Btu/h 1882 2790 3669 2358 4545 2805 4131 5356 3234 4737 6110 3851 5606 7199 Watt 6919 9519 12522 8052 15509 9573 14095 18278 11040 16164 20849 13143 Btu/h 2027 3004 3951 2540 4894 4449 5768 3483 5102 6580 4147 6037 7753 Watt 7413 10251 13485 8672 16702 10310 15179 19684 11889 17408 22453 14154 Btu/h 2172 3219 4233 2721 5244 4767 6180 3732 5466 7050 444 6468 8307 Watt 10 14448 92912 17895 11046 16263 21090 12738 18651 24057 Btu/h 6

Delta T 50 Heat outputs to BSEN 442 CERTIFICATION Heat outputs based on a mean radiator water temperature of 70 C and room temperature of 20 C Delta T 50. height (mm) 300 400 500 600 750 Model length (nominal) mm in secs 400 15.7 10 K1 SPG P+ K2 output 226 335 438 283 543 337 497 640 388 570 730 461 673 856 Watt 771 1144 1495 966 80 1852 1149 1695 2184 1325 1945 2492 1574 2297 2922 Btu/h 520 20.4 13 600 23.6 15 720 28.3 18 800 31.5 20 920 36.2 23 1000 39.4 25 1120 44.1 28 1200 47.2 30 1320 52.0 33 1400 55.1 35 1600 63.0 40 1800 70.9 45 78.7 50 2200 86.6 55 2400 94.5 60 2600 102.4 65 2800 110.2 70 3000 118.1 75 294 436 569 368 706 438 646 832 505 741 950 600 875 1113 Watt 1002 1487 1943 1256 2408 1494 2204 2839 1723 2528 3240 2046 2986 3799 Btu/h 339 503 657 425 814 505 745 960 583 855 1096 692 1010 1285 Watt 1157 1716 2242 1449 2778 1724 2543 3276 1988 2917 3738 2361 3446 4383 Btu/h 407 603 788 510 977 606 894 1152 699 1026 1315 830 1212 1542 Watt 1388 2059 2690 1739 3334 2069 3051 3931 2385 3501 4486 2833 4135 5260 Btu/h 452 670 876 566 1086 674 994 1280 777 1140 1461 922 1346 1713 Watt 1542 2287 2989 1933 3704 2298 3390 4368 2651 3890 4984 3147 4594 5844 Btu/h 520 771 1007 651 1248 775 1143 1472 893 1311 1680 1061 1548 1970 Watt 1774 2631 3437 2223 4260 2643 3899 5023 3048 4473 5732 3619 5283 6721 Btu/h 565 838 1095 708 1357 842 1242 1600 971 1425 1826 1153 1683 2141 Watt 1928 2859 3736 2416 4630 2873 4238 5459 3313 4862 6231 3934 5743 7305 Btu/h 633 939 1226 793 1520 943 1391 1792 1088 1596 2045 1291 1885 2398 Watt 2159 3202 4185 2706 5186 3218 4746 6115 3711 5446 6978 4406 6432 8182 Btu/h 678 1006 1314 850 1628 1010 1490 1920 1165 1710 2191 1384 2020 2569 Watt 2313 3431 4484 2899 5556 3448 5085 6551 3976 5835 7477 4721 6891 8766 Btu/h 746 1106 1445 935 1791 1111 1639 2112 1282 1881 2410 1522 2222 2826 Watt 2545 3774 4932 3189 6112 3792 5594 7206 4373 6418 8224 5193 7580 9643 Btu/h 791 1173 1533 991 1900 1179 1739 2240 1359 1995 2556 1614 2356 2997 Watt 2699 4003 5231 3382 6482 4022 5933 7643 4638 6807 8723 5508 8040 10228 Btu/h 904 1341 1752 1133 2171 1347 1987 2560 1554 2280 2922 1845 2693 3426 Watt 3085 4575 5978 3865 7408 4597 6781 8735 5301 7780 9969 6295 9188 11689 Btu/h 1017 1508 1971 1274 2443 1516 2236 2880 1748 2565 3287 2075 3029 3854 Watt 3470 5147 6725 4348 8334 5171 7628 9827 5964 8752 11215 7082 10337 13150 Btu/h 1130 1676 2190 1416 2714 1684 2484 3200 1942 2850 3652 2306 3366 4282 Watt 3856 5719 7473 4832 9261 5746 8476 10919 6626 9725 12461 7868 11485 14611 Btu/h 1243 1844 2409 1558 2985 1852 2732 3520 2136 3135 4017 2537 3703 4710 Watt 4241 6291 8220 5315 10187 6321 9323 12011 7289 10697 13707 8655 12634 16072 Btu/h 1356 2011 2628 1699 3257 2021 2981 3840 2330 3420 4382 2767 4039 5138 Watt 4627 6862 8967 5798 11113 6895 10171 13103 7952 11670 14953 9442 13782 17533 Btu/h 1469 2179 2847 1841 3528 2189 3229 4160 2525 3705 4748 2998 4376 5567 Watt 5012 7434 9714 6281 12039 7470 11018 14195 8614 12642 16199 10229 14931 18994 Btu/h 1582 2346 3066 1982 3800 2358 3478 4480 2719 3990 5113 3228 4712 5995 Watt 5398 8006 10462 6764 12965 8044 11866 15286 9277 13614 17446 11016 16079 20455 Btu/h 1695 2514 3285 2124 4071 2526 3726 4800 2913 4275 5478 3459 5049 6423 Watt 5784 8578 11209 7247 13891 8619 12714 16378 9940 14587 18692 11803 17228 21916 Btu/h 7

8 Weight in kg Height [mm] 300 400 500 600 750 Type Length [mm] K1SPG P+ K2 400 4,47 6,88 8,17 5,85 10,85 7,20 11,13 13,49 8,58 13,26 16,17 10,64 16,46 20,18 520 9,26 14,32 17,42 11,06 17,10 20,94 600 6,42 9,92 11,82 8,51 15,92 10,57 16,35 19,97 12,66 19,57 24,07 15,80 21,41 30,22 720 12,60 19,47 23,85 15,12 23,36 28,81 18,90 29,19 36,24 800 8,36 12,95 15,46 11,17 20,99 13,94 21,56 26,44 16,75 25,88 31,97 20,97 32,37 40,26 920 15,97 24,69 30,33 19,21 29,67 36,71 24,10 37,15 46,28 1000 10,30 15,98 19,11 13,83 26,06 17,31 26,78 32,92 20,84 32,20 39,87 26,13 40,33 50,30 1120 19,34 29,91 36,80 23,29 35,98 44,61 29,23 45,10 56,32 1200 12,24 19,01 22,75 16,49 31,13 20,68 31,99 39,39 24,93 38,51 47,77 31,30 48,29 60,33 1320 22,70 35,12 43,28 27,38 42,30 52,51 34,40 53,06 66,36 1400 14,19 22,04 26,40 19,15 36,19 24,05 37,21 45,87 29,02 44,82 55,67 36,47 56,25 70,37 1600 16,13 25,07 30,04 21,81 41,26 27,42 42,42 52,34 33,11 51,13 63,57 41,64 64,20 80,41 1800 18,07 28,10 33,68 24,47 46,33 30,79 47,64 58,82 37,19 57,44 71,47 46,80 72,16 90,45 20,02 31,14 37,33 27,13 51,40 34,16 52,85 65,29 41,28 63,76 79,37 51,96 80,12 100,49 2200 40,97 37,53 58,07 71,77 45,37 70,07 87,27 2400 44,62 40,90 78,25 49,46 95,17 2600 48,26 44,27 84,72 53,55 103,07 2800 51,91 3000 55,55

Outputs The radiator outputs quoted in this publication are based on a mean water temperature in the radiator of: 1.) 70 C (158 F) and a room temperature of 20 (68 F) Delta T50. 2.) 80 C (176 F) and a room temperature of 20 (68 F) Delta T60. For other operating conditions i.e. difference between mean water temperature and room temperature other than 50 C or 60 C the correction factors below should be applied (see example below). 1.) Factors for differences between mean water temperature and room temperature in C and F other than 50 C (122 F) C F 5 C 0.050 45 C 0.872 10 F 0.039 80 F 0.578 10 C 0.123 50 C 1.000 20 F 0.095 90 F 0.673 15 C 0.209 55 C 1.132 30 F 0.161 100 F 0.772 20 C 0.304 60 C 1.267 40 F 0.235 110 F 0.874 25 C 0.406 65 C 1.406 50 F 0.314 120 F 0.979 30 C 0.515 70 C 1.549 60 F 0.397 130 F 1.086 35 C 0.629 75 C 1.694 70 F 0.486 140 F 1.196 40 C 0.748 2.) Factors for differences between mean water temperature and room temperature in C and F other than 60 C (140 F) C F 5 C 0.040 45 C 0.688 10 F 0.032 80 F 0.483 10 C 0.097 50 C 0.789 20 F 0.080 90 F 0.563 15 C 0.165 55 C 0.893 30 F 0.135 100 F 0.646 20 C 0.240 60 C 1.000 40 F 0.196 110 F 0.731 25 C 0.406 65 C 1.110 50 F 0.262 120 F 0.818 30 C 0.320 70 C 1.222 60 F 0.332 130 F 0.908 35 C 0.496 75 C 1.337 70 F 0.406 140 F 1.000 40 C 0.590 An example of radiator selection at a non-standard temperature difference is given below: Example Heat emission required Watts Room air temperature required 15 C Mean water temperature in radiator 65 C 1. Temperature difference = 65-15 = 50 C 2. From Factor Table 50 C gives a factor of 0.798 3. Divide required heat emission by factor = = 2506 Watts 0.798 4. From selection tables choose any radiator rated at 2506 Watts or more. Again, in accordance with BSEN 442: 1997, the heat output figures in this leaflet have been derived from tests made with top and bottom same side connection (T.B.S.E.). When bottom opposite end connections are used (B.O.E.), there will be a small reduction in heat output. 9

Conditions of sale (U.K. sales) Unless varied by us by endorsement on our Acknowledgement of Order all goods are sold only upon the following conditions (except those which are inconsistent with any terms overleaf) and will override any terms in the Buyer order: 1. Quotations: Are valid for acceptance for 28 days from the date shown unless withdrawn by us before that date and are subject to our written acceptance of the Buyer s order. 2. Prices and Discounts: Are subject to alteration without notice and are given as a guide only as all goods are sold at prices ruling on date of despatch. Prices are exclusive of Value Added Tax which will be added to the Buyer s invoice where applicable. 3. Delay and Cancellation: Any delivery date indicated shall be regarded as an estimate only, although we shall make every effort to ensure prompt delivery. Whilst every effort will be made to carry out the contract, its due performance is subject to cancellation by us without compensation or to such variation as we may find necessary as a result of scarcity of labour, materials or supplies, or because of any Act of God, war, strike, lockout or other labour disputee fire elements legislation, or (without prejudice to the generality of the foregoing) any other cause beyond our control. 4. Delivery and Risk: Delivery shall be when the goods have been delivered to the Buyer s premises or to such other place as the Buyer may require. The risk shall pass to the Buyer when the goods have been delivered. 5. Transport: Will be effected or arranged by us and goods will be delivered to destinations in the United Kingdom carriage paid unless: (i) value of order is less than 300, or (ii) we are informed by the Buyer that goods are to be transported by Passenger train, air or other special delivery the extra carriage charges involved will be added to the Buyer s invoice. 6. Damage in Transit: No claim for goods lost or damaged in transit will be entertained by us unless notification of the nature and extent of such a claim is recieved by us and the Carrier within 48 hours of receipt of damaged goods or within 28 days of despatch in the event of loss. Our liability shall in no circumstances exceed in the invoiced value of the goods lost or damaged. Goods subject to claim shall be stored free of charge for inspection. They shall not be returned to nor accepted by us without our prior written consent. 7. Warranties: (i) Radiators: All Radiators are tested by us to a hydrostatic test pressure of 189 psi. Subject to the provisions of paragraph (ii), we will only accept responsibility for the replacement of any radiator which is or has become faulty by reason of defective materials or negligent workmanship. No liability is accepted for installation charges that may be incurred. (ii) General: a) All components not of our own manufacture which are or have become faulty by reason of defective materials or negligent workmanship are guaranteed to the extent only of our supplier s guarantee (if any) and without further responsibility on our part. b) Goods subject to claim shall not be returned to nor will be accepted by us without our written consent. c) The above warranties shall not be available to the Buyer if the part has been rendered faulty by alteration treatment or processing by either the Buyer or installer or ultimate consumer other than in the ordinary course of installation or in the ordinary use and/or if we do not receive notification of the fault within 14 days of its occurence. 8. Dimensions and Illustrations. Given in our pricelists and publicity brochures have been prepared with every care but their accuracy is not guaranteed and we reserve the right to vary such information without notice. Exact dimensions will be provided on application. 9. Payment: All invoices shall be due for payment on or before the last day of the month following the date of invoice. Default in payment of any invoice shall entitle us to treat any outstanding contracts between us and the Buyer as repudiated by the Buyer. 10. Ownership: Until full payment has been made of all sums (including debts arising before the date of this Contract) outstanding from the Buyer to us (time of such payment being of the essence) a) the property of the goods shall remain with us. b) the Buyer shall keep and store the goods in such a manner that they can be identified as being our property. c) the Buyer shall be at liberty to sell the goods in the ordinary course of business for our account. d) the benefit of any contract of sale and the proceeds of any sale shall be our property and held in trust for us absolutely and the Buyer shall transfer to us any claim it may have against a third party resulting from a sale of the goods by the Buyer. e) we may by written notice terminate the Buyer s power of sale at any time if the Buyer goes or threatens to go into receivership or liquidation and f) at any time after the termination of the power of sale, we may reposses the goods and the Buyer hereby grants us an irrevocable licence to enter upon any premises of the Buyer for the purpose of so doing. 11.Liability: The rights conferred by these conditions shall so far as legally possible replace and exclude all common law, statutory or other warranties or conditions whether express or implied. Save as specifically mentioned above we do not accept liability, whether in tort or contract or otherwise, for any direct or indirect loss or damage, howsoever arising. 12.Waiver: Our rights shall not be affected or restricted by any indulgence or forbearance to the Buyer. No waiver by us of any breach shall operate as a waiver of any later breach. 13.Variation of Conditions: No variation of these conditions or the particulars in our acceptance shall be valid unless agreed by us in writing. 14.Law: English law applies. Any dispute shall be referred to arbitration in accordance with the Arbitration Act 1950. 10 6

VOGEL & NOOT Wärmetechnik VOGEL & NOOT PRODUCTS LIMITED Hortonwood 1, Telford, Shropshire, TF1 7GN Telephone: 01952 / 676622 Fax: 01952 / 676633 http://www.vnwt.com http://www.vnwt.co.uk