Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

Similar documents
Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

COMMERCIAL VENTILATION

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Caution: The fans must not be used in bath or shower enclosures.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Series VENTS VUT R WH ЕС

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

Horizontal Split Case Pumps Type U

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

5 year fan housing and motor warranty

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation


Introduction to Fans. The Basics of Fan Principles and Terminology

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE

Air in Motion. Fan Guide Book. January 2001 FB-0101

Axial fans The right fan for every house

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Ducted Propeller. Airflow Volume

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

AGN 088 Air Flow and Cooling

EHH SERIES DRAW THROUGH FAN COILS CFM

Outside Air Requirements... SOLVED!

CR1 Series Triton Corrosion Resistant Washdown Heaters

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

CASSETTE UNIT. Comfort Circle

Selecting the Correct Fan

WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN!

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

Slim Contour Unit Cooler

TopMaster Air Handling unit. Installation instructions

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

Stationary screw compressors. Catalog #2

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

LOWERING THE COST OF HIGH CEILINGS

For performance and dimensional data, see back page.

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Glass Canopy Wall-Mount Hood

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Innovation for a Better & Greener Future

Innovation & Energy Efficient VENTILATION SYSTEMS.

Residential Fans & Air Purifiers

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SPECIFICATION FOR APPROVAL

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Selecting Fans and Determining Airflow for Grain Drying and Storage

U n i t H e at e r s

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Solar Powered Roof Ventilation Fan

LUH HORIZONTAL FAN-FORCED UNIT HEATER

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS

Enclosure Temperature Control

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

KOMFORT EC DB Suspended heat recovery air handling units

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Fans: Features and Analysis

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

K sin. Mini Split Air Conditioners and Heat Pump

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Condensing Units CUS 15-60

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

INSTALLATION DO S AND DON TS

Gas-Fired Unit Heaters Commercial & Industrial

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

Commercial Evaporative Cooling

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

IPVB EC inline power venter

Unico Training. Class for R E Michel Salesmen

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

Transcription:

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV Thermal Stratification Number One Reason for Energy Waste in Todays Buildings Tel: 1-888-640-0925 Tel: 513-348-3853 Fax: 513-268-4597 sales@ventsus.com VentsUS.com 11013 Kenwood Road Cincinnati, Ohio 45242

What is Thermal Destratification? Destratificator is one of the simplest and most cost-effective ways to lower energy costs and create an exceptionally comfortable thermal environment for inhabitants during both heating and cooling seasons. A destratificator gently directs the conditioned air at the ceiling to a required place at floor level. Cold Weather Problem Cold Weather Fix Naturally in any heated building, warm air migrates to the ceiling. On the average the temperature increases by 0.5-1 F for each elevated foot. This means, for example, it can be as much as 10-20 F hotter at the ceiling of a 20 ft. high facility as compared to the floor. The painful economic reality is that you pay for energy (heat) that is quite literally going through the roof (fig.1). 82 0 F Ceiling 77 0 F 64 0 F Floor Moving the superheated air at the ceiling - where it obviously doesn t do anybody any good - down to the floor level with a destratificator is one of the least expensive and easiest ways to lower utility bills drastically with the added bonus of generating a more comfortable environment for people inside. Ceiling Floor Cold and hot air resistance Hot Weather Problem An added factor is introduced in buildings with air conditioning. The cold air coming out of the ductworks at the ceiling is fighting the rising warmer air. The traditional solution has always been to install lots of refrigeration units as a way to force out the rising hot air with warm air. It has been estimated that up to 40% of the input energy for air conditioning is just wasted as it pumps out massive cold air volumes in attempts to overpower warm air that is formed at the floor. Hot Weather Fix Installing Destratificators near the cold air registers will actively direct the conditioned air where required, which results in tremendous energy savings. Moreover, it reduces wear and tear and prolongs service life of the already installed air conditioning equipment due to lower operating load. Conditioned air active pushing HOW TO ARRANGE А CORRECT HOT OR COLD AIR CONVECTION? WE SUGGEST YOU THE BEST SOLUTION WITH OUR BRAND NEW DESTRATIFICATION FANS!!! The VENTS Destratificator is a perfect solution for almost any commercial, educational, governmental or industrial buildings with 12-30 feet ceiling height.

Extract the maximum benefits from the heating and air conditioning you pay for with VENTS Destratificators! Less HVAC system load Lower energy losses Bad working environment Good working enwironment Fig.1 Negative heating stratification. Fig.2 Smart heating destratification. Benefits are clear: Up to 50% reduction of heating costs and 35% reduction of cooling costs. Longer HVAC equipment service life More comfortable working environment Low operating costs 12-24 months investment return Easy mounting without HVAC ducting Fig.3 Air conditioning destratification in a grocery shop. How Many do we Need? The rule of thumb for the healthy environment is to provide indoor air circulation once or twice per hour. So to determine the number of the destratification needed use this formula: step 1 step 2 V General rule calculation L x W x H = V (Height x Width x Length = Air Volume in Building) CFM / / = (Air Volume in Building) (the CFM of the Destratificator) (converts CFM to CFH) (Number of the units) 60 N 125 x 75 x 20 = 187,500 cu. Ft For example, a building is 125 ft long, 75 ft wide, and 20 ft high. 187,500/ 920 (for DRF-VKM 315) / 60 = 3.39 Destratificators (Always round up to the next number. In this case 4 Destratificators are required.)

DRF-VK Design Air Intake Head for more Efficient Intake of the hot air from under the ceiling space. Sound Attenuating Сover of Air Intake Head reduces noise reflection from the ceiling to the operating area. Centrifugal Impeller with Backward Curved Blades creates strong pressure to enable Powerful Air Jet for effective destratification. High-Efficient external rotor motor made in Germany. Equipped with built-in Thermal Overheating Protection with automatic restart. Motor Ball Bearings with selective lubricant oil ensure low-noise and Maintenance-Free fan operation. Aluminium Guiding Nozzle to Enhance Air Jet even more. UV-protected durable corrosion-resistant polymer case. The fastening design is so simple that you can install the DRF-VK fan with your own hands easy and quickly. The special Rotating Mounting Bracket is used for reliable fixation of the destratification fan at any angle not only to the ceiling, but to the wall. Tether for additional mounting Safety. Build-in Temperature Control turns the fan on only when hot air is collected under the ceiling (Models DRF-VK...U). DRF-VKM Design Air Intake Head for more Efficient Intake of the hot air from under the ceiling space. Sound Attenuating cover of Air Intake Head reduces noise reflection from the ceiling to the operating area. Centrifugal Impeller with Backward Curved Blades creates strong pressure to enable Powerful Air Jet for effective destratification. High-Efficient external rotor motor made in Germany. Equipped with built-in Thermal Overheating Protection with automatic restart. Motor Ball Bearings with selective lubricant oil ensure low-noise and Maintenance-Free fan operation. Aluminium Guiding Nozzle to Enhance Air Jet even more. Metal with polymer coating for Superior Corrosion Resistance. The fastening design is so simple that you can install the DRF-VKM fan with your own hands easy and quickly. The special Rotating Mounting Bracket is used for reliable fixation of the destratification fan at any angle not only to the ceiling, but to the wall. Tether for additional mounting Safety. Build-in Temperature Control turns the fan on only when hot air is collected under the ceiling (Models DRF-VKM...U). DRF-OV Design Axial fan combines Extremely Low Energy Demand and Powerful Air Jet. High-Efficient external rotor motor made in Germany. Equipped with built-in Thermal Overheating Protection with automatic restart. Motor Ball Bearings with selective lubricant oil ensure low-noise and Maintenance-Free fan operation. Durable metal case with polymer coating for Superior Corrosion Resistance. The fastening design is so simple that you can install the DRF-OV fan with your own hands easy and quickly. The special Rotating Mounting Bracket is used for reliable fixation of the destratification fan at any angle not only to the ceiling, but to the wall. Tether for additional mounting Safety. Build-in Temperature Control turns the fan on only when hot air is collected under the ceiling (Models DRF-OV...U).

Application Smooth opening of DRF-OV airstream Mushroom widening of DRF-VK and DRF-VKM airstream Operating area 6' (~2m) Installation height 29' (~9m) Privilege of the DRF-VKM & DRF-VK products DRF-VKM & DRF-VK destratification fan is equipped with a specially designed nozzle to attain the maximum possible destratification. A unique mushroom-shaped airstream, initially narrow with wide opened reach, is the basic advantage of the DRF-VKM/VK destratification fans. The smart airstream profile produces higher air supply with lower velocity in operating areas to create a more comfortable environment particularly where you need it. Due to initially slimmer air jet profile the centrifugal destratification fans DRF-VKM/VK applications are especially suitable for grocery shops and warehouses with high racks as compared to axial destratification fans as the centrifugal models are able to eject airstream precisely into aisles with higher destratification efficiency whereas the axial models have to fight air resistance created by the racks. DRF-OV Effective Destratificated Area DRF-VK and DRF-VKM Effective Destratificated Area Privilege of the DRF-OV product Axial fan of the DRF-OV destratificator combines high airflow and extremely low power demand. The axial DRF-OV models are especially suitable for wide open space premises. Due to high airflow in bigger areas you need less units and pay less energy costs to attain the desired microclimate! Control All VENTS destratification fans DRF-VKM & VK & OV can be supplied with a Built-in Speed Controller with Temperature Sensor (Models with "U" option). When the temperature exceeds the set point the speed controller starts the fan on at the set speed. As the air temperature drops below the set point the controller switches the fan off. As soon as the air temperature rises again and the temperature sensor exceeds the previously set temperature, the controller starts the motor ON automatically and it runs at the set speed. As a result, the fans only run when needed. Temperature settings range from 70 F to 95 F.

Technical data Volts Max. Watts Max. Amps RPM DRF-VK 315 120V, 60Hz 238 1.99 2180 DRF-VKM 250 120V, 60Hz 269 2.28 2710 DRF-VKM 315 120V, 60Hz 258 2.21 2800 DRF-OV 250 120V, 60Hz 60 0.51 1700 DRF-OV 300 120V, 60Hz 85 0.73 1655 DRF-OV 350 120V, 60Hz 162 1.38 1685 Airflow CFM (L/s) 470 (222) 430 (203) 550 (260) 420 198 830 392 1460 689 Air flow speed depending on DRF distance point, m/s 1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 11m 12m 6.4 3.9 3.0 2.3 1.8 1.6 1.4 1.2 0.9 0.5 0.3 0.1 7.5 5.5 3.8 2.7 1.7 0.9 0.5 0.3 0.1 - - - 6.7 4.3 3.7 2.7 1.5 0.9 0.5 0.3 0.1 - - - 2.1 1.5 1.1 0.8 0.5 0.3 0.1 - - - - - 4.6 2.9 1.6 1.1 0.8 0.5 0.3 0.1 - - - - 6.1 4.2 3.8 2.4 1.8 1.5 1.1 0.9 0.6 0.3 0.1 - Overall dimensions Type Dimensions [inch] D D1 D2 H H1 H2 Mass [lbs] DRF-VK 315 15 3/4 " 5 1/2 " 12 3/8 " 25 5/8 " 21" 2 1/2 " 14.55 Type Dimensions [inch] D D1 D2 H1 H H2 Mass [lbs] DRF-VKM 250 13 9/16 " 4 7/16 " 9 13/16 " 15 15/16 " 23 1/16 " 1 1/4 " 7.5 DRF-VKM 315 15 13/16 " 5 1/2 " 12 5/16 " 19 5/8 " 26 15/16 " 2 3/16 " 8.7 Type Dimensions [inch] A H H1 D D1 Mass [lbs] D1 A 9,1 DRF-OV 250 15 3/16 " 20 3/16 " 15 3/16 " 10 3/16 " 13 7/16 " 6.6 DRF-OV 300 17 1/4 " 23 7/8 " 17 15/16 " 12 3/16 " 15 7/16 " 11 H1 H DRF-OV 350 19 3/16 " 27 5/16 " 20 5/16 " 14 3/16 " 17 3/8 " 13.2 D Contacts Tel: 1-888-640-0925 Tel: 513-348-3853 Fax: 513-268-4597 sales@ventsus.com VentsUS.com 11013 Kenwood Road Cincinnati, Ohio 45242 VENTS US reserves the rights to modify any of its products features, designs, components, and specifications at any time and without notice to maintain the development and quality of manufactured goods. Flow Chart Graphs can be viewed at www.vents-us.com 12/01

Contacts Tel: 1-888-640-0925 Tel: 513-348-3853 Fax: 513-268-4597 sales@ventsus.com VentsUS.com 11013 Kenwood Road Cincinnati, Ohio 45242 VENTS US reserves the rights to modify any of its products features, designs, components, and specifications at any time and without notice to maintain the development and quality of manufactured goods. Flow Chart Graphs can be viewed at www.vents-us.com