Universal Tank Alarm Type Installation, Operation & Maintenance

Similar documents
Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Solar Separator Alarm Type Installation, Operation & Maintenance

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

14300 MAINS SEPARATOR ALARM MANUAL

SOLAR SEPARATOR ALARM

DB5 Intrinsically Safe Sounder Type DB-5

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

4) Intrinsic Safety Certification

SET Installation and Operating Instructions. Level switch for one sensor

IECEx Certificate of Conformity

Intrinsically Safe Solutions

HYTEK ATEX APPROVED TANK ALARM

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

INSTRUCTION MANUAL (ATEX / IECEx)

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

HYTEK ATEX APPROVED BUND ALARM

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Manual Isolating Barrier D461R1 (Revision 01)

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Inductive slot sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

OilSET-1000 (12 VDC)

SET-2000 Hi Level/Oil

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Earth-Rite II PLUS Static Earthing System

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

E2S Datasheet v10a

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Installation and Operating Instruction

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

Technical Data. General specifications. Rated operating distance s n 5 mm

Excellence in Level Measurement

Technical Data. Dimensions

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Annubar Flowmeter Series

INSTRUCTION MANUAL (ATEX / IECEx)

PROTECT SRB 200EXi-1A

RE-PR3-E-27 3-Phase Panel Mount 27kW

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Installationsmanual GWSL1100/2100, GWML3100

Declaration of conformity

EU DECLARATION OF CONFORMITY

IECEx Certificate of Conform ity

Alarm system For oil-water separator

Hazardous Area Zirconia Oxygen Systems

P R O D U C T D ATA S H E E T

RT FLOW RATE TOTALISER

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION & SERVICE MANUAL

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

XP95 Intrinsically Safe Product Guide MAN 3054

ABB Instrumentation. Instruction Manual. Model 6553 Series of Intrinsically Safe Gas Analyser Systems for Hydrogen & Purge Gas Purity Measurement

Intrinsically Safe Flame Detector Installation Guide

SET-2000 Oil/Sludge 12 VDC

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Manual Isolating Barrier D461 (Revision 05)

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SEK-3 Marine Grounding System

Certification Supplement Manual

Technical Data. Dimensions

P R O D U C T D ATA S H E E T

Gas cylinder scale Model GCS-1

TX6831 Data Sheet. Features. Benefits

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Rosemount 702 Wireless Discrete Transmitter

Certification Supplement Manual

User Guide IM/AK1/23 Rev. N. AK102 and AK103 Gas analyzer systems for Hydrogen-cooled alternators

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

TEM-EX-B. Figure: TEM-EX-B with PROMOS connector. ka055100en; Rev. 1.8

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

Operating Manual MS220Vi and MSR220Vi

Technical Data. Dimensions

FDOOT241-A9-Ex Multisensor fire detector

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

Transcription:

Universal Tank Alarm Type 14400 Installation, Operation & Maintenance

Universal Tank Alarm Type 14400 Contents Declaration of Conformity 3 IMPORTANT 3 General Description 4 General Operation 4 Installation 4 Technical Information 4 o Specifications 4 o Beacon output 4 o Input/Output Parameters 5 o Probe Cables 5 o Mechanical 5 o Probes Terminals 5 o Beacon Terminals 5 Accessories 6 o Probe Cable 6 o Beacon 6 Maintenance & Repair 6 MAN-8060 Rev. 2 (31/08/2015) 2

Declaration of Conformity Universal Tank Alarm Type 14400 Installation, Operation and Maintenance The above product meets all the essential safety requirements of the European Directives and standards listed below, and is issued under the sole responsibility of the manufacturer Name and Address of Manufacturer Darcy Products Ltd. Unit B7 Chaucer Business Park Watery Lane Kemsing Kent TN15 6QY United Kingdom Valid for European Directives 94/9/EC until 19 th April 2016 2014/34/EU from 20 th April 2016 Equipment Name and Type 14400 series Universal Tank Alarm Certificate Number Baseefa 13ATEX0172 Specific Marking of Explosion Protection [Ex ia Ga] IIB (-20 C Ta +50 C) ATEX Directive Marking Ex II (1) G Notified Body Baseefa 1180 Buxton UK CE Mark with Notified Body Number CE 1180 Harmonised Standards Used EN 60079-0:2012 EN 60079-11:2012 Serial Number and Year of Manufacture Displayed underneath the control unit On behalf of the above named company, I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment conforms to all technical and regulatory requirements of the above listed directives. Peter Bowden Quality Manager IMPORTANT Note: In all cases good, standard electrical practice should be followed, and the installation must conform to the appropriate local code of practice e.g. BS EN 60079-25 in the UK. In essence, the installation must be such that the intrinsic safety is not compromised by: - exposure to risk of mechanical damage, unauthorised modification or interference, exposure to moisture, dust and foreign bodies, excessive heat, invasion of intrinsically safe circuit by other electrical equipment or circuitry. Please contact Darcy for any advice on 01732 441016. MAN-8060 Rev. 2 (31/08/2015) 3

General Description The unit is designed to monitor a tank for a build-up of oil and sound an alarm and flash a xenon beacon when oil is detected. General Operation The unit continuously checks for the presence of oil at the probe by measuring conductivity; however a float switch probe may be used. The probe is normally submersed in water and the LED on the unit will be green. When there is a sufficient build-up of oil at the surface that covers the conductivity probe, a sounder inside the unit sounds intermittently and the attached xenon beacon flashes. The LED on the unit turns red. To silence the sounder and stop the xenon beacon flashing, press the button on the unit. The LED will remain red until the probe detects water once again. Installation This product has been designed and certified as being intrinsically safe. It is of paramount importance that the unit should not be modified in any way and the installation be carried out by an approved installer, in accordance with the Environment Agency guidelines (PPG3). Any deviation from this could invalidate the certification warranty and render the unit unsafe for its intended use. Technical Information Specifications Enclosure 180mm(W) 130mm(H) 60.5mm(D) IP66/67 ABS 230VAC ±10%, 50/60Hz TBA Supply Voltage Current Consumption Fusing FS1 T 250mA H 250V 1500A breaking capacity FS2 Littelfuse 0242.050UAT1 50mA 250V 4000A breaking capacity Max probe cable length Beacon Output (CN2) Table 1 - Specifications 200m (less if values in Table 3 would be exceeded) 11.2V DC, 100mA maximum Beacon Output The beacon output, CN2, must only be connected to a beacon. See notes below for restrictions on its use. This output is activated when the probe detects a build-up of oil and is deactivated again by pressing the button on the unit. MAN-8060 Rev. 2 (31/08/2015) 4

Notes on the beacon output: 1. Um = 0, i.e. no other source of power must ever be connected directly or indirectly to this output. 2. Cable used must have 1mm insulation and be 2m length. 3. Must only be connected to a beacon which is powered entirely from this unit, i.e. this output must not be used as a control signal to a beacon that has its own power supply. 4. The beacon must be isolated from earth. Input/Output Parameters U o 15.8 I o 175µA P o C i 0 L i 0 Table 2 - Hazardous Area Terminals (CN3) < 1mW Group Capacitance (µf) Inductance OR L/R Ratio (mh) (µh/ω) IIB 2.88 4463000 206000 IIA 11.6 9287000 412000 Table 3 CN3 Load Parameters Probe Cables The total capacitance and inductance of the cable used between the tank alarm unit and the probe must not exceed that shown in Table 3. Mechanical Protection and/or screening of the cable should be taken into account when choosing a suitable cable. The maximum cable length between the probes and the tank alarm unit must not exceed 200 metres, or less if the values in Table 3 would be exceeded. Probe Terminals Probe Type A B Table 4 - Probe Cable Connection Details (CN3) High Oil RED BLUE Beacon Terminals CN8 Terminal Connect To + Beacon positive terminal - Beacon negative terminal Table 5 - Beacon Cable Connection Details (CN2) MAN-8060 Rev. 2 (31/08/2015) 5

MAN-8060 Rev. 2 (31/08/2015) 6

Accessories Probe Cable Whilst many different cables can be suitable for use with the probe, some customers feel more comfortable with some guidance. A typical example of a suitable cable is shown in Table 6. It can be ordered from Darcy or from Farnell (http://www.farnell.com) as order code 1503980. Manufacturer Lapp Kabel Manufacturer Part No. 0012640 Inductance 0.65mH/km Capacitance Core-core: approx. 135nF/km Core-screen: approx. 185nF/km Table 6 - Typical Probe Cable Beacon A suitable 12V xenon beacon is detailed in Table 7. It can be ordered from Darcy or RS Components (http://www.rs-components.com) as order code 309-5944. Manufacturer Klaxon Manufacturer Part No. 45-713121 Voltage 12V Current 60mA (average) Colour Amber IP Rating IP65 Table 7 Beacon Specifications Maintenance and Repair For all repairs, contact Darcy Spillcare Manufacture on 01732 441016. MAN-8060 Rev. 2 (31/08/2015) 7

MAN-8060 Rev. 2 (31/08/2015) 8