a Unbeatable efficiency at partial loads a Compliance with the strictest environmental standards

Similar documents
Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1949 kw

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

High efficiency water cooled chiller, with oil-free centrifugal compressor, from 246 to 4191 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Air source units for 4-pipe systems, with screw compressors and full inverter technology, from 341 to 1125 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 235 TO 1463 kw

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLERS WITH INVERTER SCREW COMPRESSORS AND HFO REFRIGERANT FROM 377 TO 1463 kw

PROCESS CHILLERS. AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 140 TO 1710 kw R513A. climaveneta.com

COMFORT CHILLERS. AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 140 TO 1710 kw R513A. climaveneta.com

climaveneta.com AIR SOURCE UNITS FOR 4-PIPE SYSTEMS, WITH SCREW COMPRESSORS AND FULL INVERTER TECHNOLOGY, FROM 341 TO 1125 kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

COMFORT HYDRONIC TERMINALS

HYDRONIC RESIDENTIAL

Be sustainable while protecting your business

AIR HANDLING UNITS FROM 600 TO m3/h

Process Cooling PRODUCT OVERVIEW. climaveneta.com PRELIMINARY CHILLERS UNITS FOR SIMULTANEOUS AND INDEPENDENT PRODUCTION OF HOT AND COLD WATER

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

Air source chillers with screw compressors, from 289 to 1710 kw

Precision air conditioners with inverter technology for stable room conditions

AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 289 TO 1710 kw

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

WATER TO WATER HEAT PUMPS FOR VERY HIGH TEMPERATURE WATER PRODUCTION, CAPACITY FROM 70 TO 279 kw.

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

PROCESS CHILLERS. AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 235 TO 1463 kw. climaveneta.com

Conditioning your ambient, maximising your comfort.

NX-N. Climaveneta Technical Bulletin NX_N_0604T_1204T_201211_EN

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF


EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

Water-cooled chillers with High Speed Centrifugal Compressors

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 81,1 TO 182 kw, AIRFLOW FROM TO m 3 /h

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Modular Air-cooled Chillers

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

PACKAGED FRESH AIR UNIT, AIR FLOW FROM 2100 TO M 3 /H

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

H4T R410A. refrigerant

Innovation for a Better & Greener Future

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

Air-cooled Screw Chillers Model RTAF G Process

Reliability and extended operation

TurboChill Water Cooled 150kW kW*

1

Making equipment decisions

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

ARS. 1

Modular Air Cooled Scroll Chillers

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

ARV.

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Chillers for High Ambient Conditions: What Technologies and Fluids?

Refrigerants & Cooling in renovation buildings

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

HFCs or the Old Refrigerants - what is the best Choice?

Corporate Mission & 7 guiding Principles

FACT SHEET 6 Transport Refrigeration

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

QUANTUM. Series and features of the energy-efficient chiller series

Low GWP alternative refrigerants to R404A

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

Magnetic Refrigeration. Study Case

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

VZ Chiller series. Water cooled inverter chiller. The highest peak in chiller technology

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

BRAN. Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN ,6-31,3 kw. Reversible unit, air source for outdoor installation

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Air to Water Heat Pump Utilising Natural Refrigerant C02

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

FX-FC _201302_EN

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Air conditioning 23XRV

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Transcription:

Air and water cooled chillers with magnetic levitation compressors and HFO 1234ze refrigerant, from 339 kw to 1.364 kw a Unbeatable efficiency at partial loads a Compliance with the strictest environmental standards a 4 th generation green refrigerant a Simplified logistics a Low in rush current

The ultimate objective of this Convention is to achieve stabilization of greenhouse gas concentrations in the atmosphere at a level that would prevent dangerous anthropogenic interference with the climate system. Such a level should be achieved with a time frame sufficient to allow ecosystems to adapt naturally to climate change, to ensure that food production is not threatened and to enable economic development to proceed in a sustainable manner. UNFCCC, 1992 United Nations Framework Convention on Climate Change 02.03

Tackling stratospheric ozone depletion and the greenhouse effect have led to drastic regulatory changes in the HVAC&R industry. Starting from the United Nations Framework Convention on Climate Change UNFCCC, the Member States are progressively setting more challenging targets in order to: Reduce greenhouse gas emissions (GHG) Tackle climate change Promote sustainable development Reduction in greenhouse gases and -40% of CO2 emissions by 2030 Keeping global warming within 2 C compared to pre-industrial era (1850) Increasing use of renewables and efficiency targets for energy related products This has posed new challenges for the HVAC industry: Against Global Warming Challenging efficiency targets Refrigerant greenhouse and global warming potential are measured by two parameters: 4ODP Ozone Depletion Potential 4GWP Global Warming Potential While in the past the main focus was on reducing ODP values down to 0, new regulations now encourage Member States to work harder on GWP. Countries are becoming more and more aware that environmental targets must be regulated by laws and programs in terms of energy efficiency targets related both to products: 4ERP Ecodesign 2009/125/EC 4MEPS and to buildings: 4LEED 4BEAM 4Green Mark 4Green Star 4BREEAM

Responding to climate change with New generation chillers with magnetic levitation technology and HFO refrigerant embracing an innovative forward-looking concept of sustainability: GREEN The eco-friendly alternative to HFCs HFO, the new generation low GWP refrigerant GWP Global Warming Potential 20.000 The 4th generation refrigerant HFOs result in being the perfect solution to keep ODP=0 and GWP levels near zero. 4.000 CFC HFO 1234ze is a gas blend characterised by extremely low GWP whilst maintaining high efficiency values. Thanks to its compatibility with standard construction materials and operating performance similar to R134a, the new HFO 1234ze is the perfect alternative to HFC refrigerants. 2.000 HFC 0 HCFC 0,05 0,1 0,5 1,0 ODP Ozone Depletion Potential Negligible GWP HFO 1234ze GWP=7 R134a GWP=1430 Rapid molecule disintegration in the atmosphere HFO 1234ze =2 weeks R134a =14 years Approved by international standards (ASHRAE 34, ISO 817) HFO 1234ze classification=a2l (non toxic, mildly flammable), safety group 2 for PED (same as R134a) Compatible with common construction materials No special components No extra cost In-line with F-Gas regulation objectives No future retrofit required 04.05

All the advantages of an eco-friendly refrigerant combined with high performing magnetic levitation technology, together with Climaveneta's renowned experience providing sustainable and highly efficient solutions. This is TECS2 HFO's key feature for a long-term sustainable solution that satisfies even the strictest environmental requirements. EFFICIENCY The ultimate technology for unbeatable performance High performance magnetic levitation technology TECS2 HFO is the latest technology of chillers with magnetic levitation compressor optimised for HFO 1234ze refrigerant. The new chiller optimised for HFO is even more performing than its predecessor working with R134a, displaying an increased efficiency value of 3% if considering the same cooling capacity. Reliability and extended life cycle Reliability is a key concept for units meant to be forerunners. Thanks to a decade of experience in magnetic levitation compressor units and thousands units installed all over the world, Climaveneta represents the best proof of total reliability, significant cost savings and longer life cycle (HFO doesn't need any future retrofit due do refrigerant legislation compliance). Higher efficiency than similar chillers with R134a Less annual energy consumption than similar chillers with R134a TECS2 HFO EER 3,5 TECS2 EER 3,4 +3,3% TECS2 HFO ESEER 5,6 TECS2 ESEER 5,4 +3,7% TECS2-W HFO EER 5,2 TECS2-W EER 5,0 +4% TECS2-W HFO ESEER 8,2 TECS2-W ESEER 7,9 +3,8% Average values of the series, according to EN14511:2011

Technological choices Magnetic levitation compressor specifically designed for HFO New generation EC fans TECS2 HFO is the result of a smart combination between the centrifugal compressor with magnetic levitation technology and the HFO 1234ze refrigerant. It is well known that the efficiency levels achieved by the magnetic levitation compressors are far superior to those with traditional volumetric compressors. Besides the reduction of weight and dimensions with respect to traditional compressors, this is a solution that permits the compressor to operate without any oil at all, allowing a significant improvement in the heat exchange performance. Vibrations are virtually eliminated together with possible jolts due to inrush current in the start up phase: the unit s wear is minimised. The new HFO magnetic levitation compressor is 3% more efficient than similar technology working with R134a. EC electronic commutation fans are characterised by high efficiency motor and, according to Regulations 327/2011, their Efficiency Grade is far superior to any other AC fan. Their extraordinary efficiency, together with really low inrush current, improves chiller performance, especially at partial loads, and contributes to the overall reliability of the unit and thus to relevant running cost savings. The ability to continuously modulate the rotational speed and perfectly adapt to the plant requirements, provides great advantages in terms of: a Minimised sound levels and energy consumption at any load condition a Large running cost savings a Premium efficiency, especially when all year round operation is required 06.07

Efficiency, reliability, silent operation. But also great care to the environmental effects of its components. All of these premises have led to the creation of TECS2-HFO: the most advanced and eco-compatible solution available on the market. Advanced controller The new controller features proprietary settings which ensure fast adaptive responses to different dynamics. The interface is intuitive and user-friendly thanks to the adoption of LED icons for a full and immediate status display of the various circuits. As an option, a touch screen interface is available with: a 7 color display a USB port, for quick and easy application updates and download of all registered variables in graphic form. Innovative design of the heat exchangers Standard interface Easy-to read LED icons The flooded evaporator, fully designed and built by Climaveneta, together with the shell and tube condenser (in water source units), present an exclusive design aimed at maximising the cooling capacity and optimising the operation of the compressors. The shell and tube condenser is designed to ensure reduced pressure drops on the water side and to decrease the pumping costs as much as possible. In the evaporator the complete flooding of the tubes is also guaranteed during partial load conditions by an electronic expansion valve, managed by proprietary control logics. On the evaporator the presence of the refrigerant fluid in the shell side and water in the tube side allows: a Minimisation of pressure drops a Perfect unified temperature as well as complete refrigerant evaporation a No surface for the over-heating a Easy cleaning operations Controls for easy and safe access to the unit s setting Optional touch screen interface 7 colour display USB port

0351-1053 High efficiency air cooled chiller for outdoor installation (339-1017 kw) Units for outdoor installation, characterised by an extremely compact layout and 4 th generation refrigerant HFO 1234ze. TECS2 HFO units easily adapt to different thermal load conditions thanks to the precise thermoregulation together with the use of inverter technology. TECS2 HFO / SL-CA-E 0351 0702 1053 Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kw 339 679 1017 Total power input (1) kw 96,3 192 282 EER (1) kw/kw 3,52 3,53 3,60 ESEER (1) kw/kw 5,56 5,96 6,00 COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kw 338 677 1014 EER (1)(2) 3,48 3,50 3,55 CERTIFIED ESEER (1)(2) kw/kw 5,36 5,75 5,64 Cooling energy class A A A EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) m³/h 58,4 117 175 Pressure drop (1) kpa 27,4 23,1 45,7 COMPRESSORS Compressors nr. N 1 2 3 No. Circuits N 1 1 2 NOISE LEVEL Noise Pressure (3) db(a) 58 59 60 Noise Power (4) db(a) 90 92 93 SIZE AND WEIGHT A (5) mm 4000 7900 9700 B (5) mm 2260 2260 2260 H (5) mm 2430 2430 2430 Operating weight (5) kg 3130 6450 7610 Notes: 1 Plant (side) cooling exchanger water (in/out) 12 C/7 C; Source (side) heat exchanger air (in) 35 C. 2 Values in compliance with EN14511-3:2011. 3 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level. 4 Sound power on the basis of measurements made in compliance with ISO 9614. 5 Unit in standard configuration/execution, without optional accessories. Accessories: - VPF (Variable Primary Flow) kit: variable flow pumps with on board regulation - Electromagnetic compatibility (EMC) - EN6100-6-3 for residential environments - Compressors power factor correction 0.95 - Remote control keyboard (distance up to 200m or up to 500m, available with standard or touch screen keyboard) - Hydronic group - Set-up for remote connectivity with ModBus/Echelon protocol cards 08.09

0351-1414 High efficiency ficiency water cooled chiller for indoor installation (340-1364 kw) Units for indoor installation, characterised by a minimum footprint and 4 th generation refrigerant HFO 1234ze. Conceived to be extremely flexible and reliable units, TECS2-W HFO are also available with the /H function (heat pump reversible on hydraulic side). TECS2-W HFO / HC 0351 0712 1053 1414 Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kw 340 676 1015 1364 Total power input (1) kw 63,0 127 190 251 EER (1) kw/kw 5,39 5,34 5,35 5,43 ESEER (1) kw/kw 9,01 9,40 9,32 9,51 COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kw 339 674 1013 1361 EER (1)(2) 5,18 5,17 5,19 5,29 CERTIFIED ESEER (1)(2) kw/kw 7,83 8,12 8,22 8,50 Cooling energy class A A A A EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow (1) m³/h 58,5 116 175 235 Pressure drop (1) kpa 32,9 29,0 31,1 33,1 Water flow (1) m³/h 69,1 138 207 277 Pressure drop (1) kpa 40,8 39,6 32,0 23,0 COMPRESSORS Compressors nr. N 1 2 3 4 No. Circuits N 1 1 1 1 NOISE LEVEL Noise Pressure (3) db(a) 74 76 77 78 Noise Power (4) db(a) 92 94 96 97 SIZE AND WEIGHT A (5) mm 2990 3490 4990 5450 B (5) mm 950 1300 1300 1300 H (5) mm 1900 1800 1800 1990 Operating weight (5) kg 1570 3010 4380 5240 Notes: 1 Plant (side) cooling exchanger water (in/out) 12 C/7 C; Source (side) heat exchanger air (in) 35 C. 2 Values in compliance with EN14511-3:2011. 3 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level. 4 Sound power on the basis of measurements made in compliance with ISO 9614. 5 Unit in standard configuration/execution, without optional accessories. Accessories: - Electromagnetic compatibility (EMC) - EN6100-6-3 for residential environments - /H version (heat pump reversible on hydraulic side) - VPF or VPF.D signal - Condensing pressure control devices - Integral acoustic enclosure

Experience is by far the best proof Sir Francis Bacon British philosopher (1561-1626) 10.11

Malteurop Group 2015 Metz (France) Application: Process Cooling Plant type: Hydronic System Cooling capacity: 1546 kw Heating capacity: 1176 kw Installer: DALKIA France Machines installed: 1 x FOCS2-W/H/CA 2 x TECS2-W HFO/HC/H/S 1414 Project Malteurop Group is leader in the malt industry working with traditional and specialty breweries, brewing groups, and whisky distilleries, together with malt-based and agribusiness industries. Labelled as an environmentally green company, one of the main points of Malteurop Group s mission is to make sure that all agricultural, industrial, and economic activities are respectful of the environment. Challenge For a group completely committed to making the environment their first priority, the choice of the HVAC system was not only a need but also a responsibility. Extremely reduced CO2 emissions, sustainable technology and the highest product efficiency during each manufacturing malting process, were therefore the main objectives of the property owner. Solution To be in line with the strict Malteurop environmental standards, 2 water cooled TECS-W HFO chillers combined with a FOCS2-W unit were the perfect cooling package provided by Climaveneta to the malt industry. TECS2-W HFO/H in heat pump configuration, were selected for the dehumidification of the malt, utilising water recovered from other processes occurring within the same plant for the source side heat exchange.

After 10 years of in-depth knowledge in the field of magnetic levitation technology and sustainable green HVAC systems, Climaveneta has already tested the success of TECS2 HFO units in several renowned projects. Because experience is not only a matter of prestige but also the best proof to provide its customers with the highest quality levels and no-compromise reliability for all kinds of applications. Genève Plage 2015 - Cologny (Switzerland) Plant type: Hydronic System Application: Gyms/Swimming pools Cooling capacity: 680 kw Heating capacity: 341 kw Installed machines: 2 TECS2-W HFO/HC/H/S 0351 Ammeraal Beltech AG 2014 - Rapperswill-Jona (Switzerland) Plant type: Hydronic System Application: Mixed-used building Cooling capacity: 676 kw Installed machines: 1 TECS2-W HFO 12.13

Métropole Lausanne (Switzerland) Plant type: Hydronic System Application: Hotels and Resorts Cooling capacity: 1016 kw Installed machines: 2 TECS2-W HFO Merck Serono SA 2014 - Aubonne (Switzerland) Plant type: Hydronic System Application: Office building Cooling capacity: 1015 kw Installed machines: 1 TECS2-W HFO Geschäftshaus Lindbergh Allee 2014 - Opfikon (Switzerland) Plant type: Hydronic System Application: Office building Cooling capacity: 1015 kw Installed machines: 1 TECS2-W HFO

More than 1000 projects all over the world Baptist University School of Chinese Medicine 2014 - Hong Kong Application: Schools and universities Cooling capacity: 1830 kw Installed machines: 2x TECS2/SL-CA-E, 1x screw air cooled chiller Principal Place THE UN SQUARE MILE 2015 - London (Great Britain) Application: Mixed-use buildings Cooling capacity: 9243 kw Heating capacity: 478 kw Installed machines: 6x TECS2-W/LC, 1x FOCS2-W/R/CA-E Singapore Sports Hub 2014 - Singapore Application: Sport facilities Constructor: BYME Singapore Designer: ARUP Cooling capacity: 35000 kw Installed machines: 8x TECS2-W/LC, 8x FOCS2-W/D/CA-E, 7x FOCS2-W/CA-E, 4x ACU, 4x AXU Cajamar Almeria 2014 - Almeria (Spain) Application: Financial buildings Cooling capacity: 1805 kw Heating capacity: 856 kw Installed machines: 2x TECS2/SL-CA-E, 1x i-fx-q/sl, 1x ClimaPRO Wuxi National Super Computing Data Center 2015 - Jiangsu Province (China) Application: Data center Cooling capacity: 25000 kw Installed machines: 18x TECS-W /H Cisco Systems Vimercate 2014 - Milan (Italy) Application: Office buildings Cooling capacity: 4505 kw Heating capacity: 459 kw Installed machines: 1x TECS2/SL-CA-E, 2x TECS-W, 1x ERACS2-WQ, 2x FOCS/SL-CA-E, 1x FX-FC, 1x ClimaPRO, several AC close control units 14.15

TECS2 HFO is just one of the latest Climaveneta innovation in the range of chillers with magnetic levitation technology. The company portfolio includes countless prestigious projects, selected for their renowned quality and prestige. AIRBUS MILITARY TABLADA 2013 - Sevilla (Spain) Application: Military airports Investor: EADS Group Designer: Savener Proyectos Cooling capacity: 3531 kw Installed machines: 3x TECS2/SL-CA-E Department of Justice 2013 - Hong Kong Application: Institutions Cooling capacity: 4590 kw Installed machines: 4x TECS2 SL-CA, 2x TECS2-W/HC Volkswagen Plant 2014 - Emden (Germany) Application: Automotive Cooling capacity: 4180 kw Installed machines: 4x TECS2-W/H Kings Avenue Mall 2014 - Paphos (Cyprus) Application: Shopping centre Cooling capacity: 5082 kw Heating capacity: 1082 kw Installed machines: 2x ERACS2-Q/SL- CA, 3x TECS2/SL-CA-E, 2x i-axo 350 Euston Road 2014 - London (Great Britain) Application: Office buildings Cooling capacity: 1022 kw Heating capacity: 541 kw Installed machines: 1x ERACS2-Q, 1x TECS2/SL, 1x ClimaPRO Palais de l'europe 2013 - Strasbourg (France) Application: Institutions Cooling capacity: 9952 kw Heating capacity: 3764 kw Installed machines: 4x ERACS2-WQ, 4x TECS2-W/HC