Operating Manual SEVi 160 Series

Similar documents
AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

Pluggit iconvent Decentralized residential ventilation with heat recovery Operating and installation instructions

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

ST1. Mod. USE AND MAINTENANCE MANUAL

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Operating instructions for the radio heat detector GS412

CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a

Operating Instruction

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

User instructions DHP-AT

HSGM Heißschneide-Geräte

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Stripping machine AI 01

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

Ventilator insert Silvento V... Installation directions - Please pass on to the user -

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

smardy - pure water Reverse osmosis system YR100-A 75 GPD

ST 53.1 User s manual

Owner & Operator s Manual. Table of Contents

Flostop TS D7E and A8E. Operation Manual

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Original operating instructions Safety switch with guard locking AC901S AC902S

Operating Instructions

GB Operating instructions

DOCUMENTATION IPS640

User manual UV Flash Dry C1

Flopurge TS. Operation Manual

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

INSTALLER S & OWNER S MANUAL

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Instructions for the fan motor control system with integrated wiring terminals SILVER C

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

Crimping machine RC AS Operating instructions

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Ducted air conditioner Operating Manual

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user -

Voltage module +SBEC S8446

Instructions For Use ENG. LED Magnifier Lamp

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

Installation manual plugs and connectors QUICK-CONNECT (63 A)

SCHMIDT LED Measured Value Display MD Instructions for Use

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

+ English + 1. Safety warnings

Clean Air Optima HEPA UV ionizer air purifier CA-508

MANUAL Overflow sensor NVF-104/34-PF

V-ZUG Ltd. Range hood. Levante. Operating instructions

INSTALLER S & OWNER S MANUAL

No. Icon Name Function

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

Environmental Monitoring SmartSlot Card

DOCUMENTATION IPS640

Strip-Cut Shredder S5

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

Energy management function at adsorption dryer PDAD

V-ZUG Ltd. Range hood DW-SE/DI-SE. Operating instructions

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Warnings, Safety Information and Guidance

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

MOBILE CALL GSM Alarm System User s Manual

Digital Heat Block User Manual

AUTOMATIC VACUUM UNIT

Instructions for the fan motor control system, SILVER C

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Operator s Manual. IP-100 Immersion Probe Cooler

Operating instructions

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

Operating and Maintenance Instructions

PresenceLight 180 PresenceLight 360

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Ceiling Mount Air Purification System

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

compact office 24V compact office 24V Lux

Waste water ejection unit

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

RVL481. Heating Controller. including d.h.w. heating

Transcription:

Operating Manual SEVi 160 Series (Intelligent ventilation system with heat recovery) Production: SEVentilation GmbH E.-Thälmann-Str. 12 07768 Kahla Tel.: +49 36424 767472 Fax: +49 36424 767471 Email: info@seventilation.de As at: 10/2016

Notes Explanation of the safety-relevant symbols and terms used in this manual: Danger: indicates a danger with a high risk which can cause death or serious injuries if it is not avoided. Warning: indicates a danger with a mean level of risk which can cause death or serious injuries if it is not avoided. Caution: indicates a danger with a low level of risk which can cause slight or moderate injuries if it is not avoided. Note: Failure to adhere to the instruction or guideline can damage the device or affect the proper functioning of the device. For the purpose of this manual, the term qualified personnel refers to persons who have the appropriate professional education to perform the activities required (e.g. electrical installation, heating and ventilation installation) and know the relevant standards and regulations. For proper disposal of packaging, separate it according to the specific material! If you want to dispose of the system, observe the current provisions! Contact the local authority for detailed information! 2

Contents 1. General information concerning the Operating Manual... 4 2. Operation... 6 2.1 SEC-20 central control unit... 6 2.2 SEC-Basic and SEC-20-BF... 7 2.2.1 Determining the device type when using SEC-Basic... 8 2.2.2 Determining the device type when using SEC-20-BF... 8 3. Maintenance and service... 12 3.1 Maintenance intervals... 12 3.2 Maintenance guidelines... 13 3.3 Fault tracking... 15 Please, also observe the instructions given in the assemblymanuals of the ventilation systems! 3

1. General information concerning the Operating Manual Check the product for completeness (see packing slip) and transport damage immediately after receiving it! The product must be stored at a safe and dry place! Adhere to the instructions in this Operating Manual! Please, observe the approval regulations and the applicable construction provisions as well as the fire prevention regulation and accident prevention regulations of the Employers Liability Insurance Association when planning, installing and operating the system. When planning the ventilation system, details must be discussed with the responsible chimney sweeper and construction manager! Before installation, contact your planner to get to know whether a RAL installation is required. Assembly works and electrical installations are to be carried out by qualified personnel! Use the ventilation system only in compliance with the applications described in this documentation and only in connection with components which have been recommended and approved by the company SEVentilation and are specified in this documentation. Modifications or reconstructions of the ventilation system are not permitted. The correct and safe operation of the ventilation system is only possible, if it is properly transported, stored and mounted as well as carefully operated and maintained. This documentation is part of the ventilation system and must always be at hand. Observe all safety regulations included in this documentation. The manufacturer shall not be held liable for damages caused by improper installation, connection and use of the system. The warranty will expire. The legal warranty periods shall apply according the General Terms and Conditions! Product description and instructions for use The SEVi 160 ventilation system with heat recovery available in different variants is used for controlled living space ventilation. A SEVi 160 ventilation system includes at least 2 SEVi 160 fans and a control unit SEC-20. Ideally, an even number of devices is to be installed (exception: SEVi 160 DUO). Principle of heat recovery 4

The devices belonging to the ventilation systemare operated in opposite directions in the heat recovery mode. This means that in pairwise operation each fan alternatively expels used room air to the outside and replaces it by fresh air which has been pre-heated in the heat accumulator. The direction of the fan is changed in intervals of 75 seconds. The ventilation system is operated with 12 V and exclusively consists of high-quality materials. In addition to the heat recovery mode, intensive brief ventilation is possible (permanent intensive brief ventilation at fan stage 4) in which, depending on the installation condition of the fans, a constant air stream is provided towards one direction to ventilate the room without opening the window (noise protection). The operation of the ventilation system is recommended throughout the year. In the seasonsin which heating appliances are not necessary, the ventilation system acts in a contrary manner. Here, summer operation (intensive brief ventilation, passive cooling) is recommended, and in this mode, the generally lower inside air temperature of the morning hours is maintained in the living space analogue to the principle of heat recovery. When the ventilation system is not in use (important during the heating season), the upper part of the interior panel is to be turned by 180 to close the interior panel to avoid, for example, that heat escapes out of the building in an uncontrolled manner and cold air enters through the ventilation device in case of power failure or in special winter conditions. Closure of the interior panel Ideally, the opening of the interior panel faces upwards (avoidance of draught below the interior panel). Note: The ventilation system is always controlled via the control unit. The system must not be operated in rooms with high dust rate. The system must not be operated in rooms in which decomposing gases are used. The system is not suited for drying out buildings. The ventilation system shall only be started up after the completion of the construction works. The ventilation system is to be closed during the construction works. Temperature range of application: -20 C to +75 C 5

2. Operation 2.1 SEC-20 central control unit The ventilation systems of the SEVi 160 series are operated via the SEC-20 central control unit. The keys desired are activated by a pressure on the membrane keypad. The operating condition, the operating mode selected and the fan stage are indicated by a blue LED top left on the corresponding keypad. 1 Device On/Off: 2 Selection of the fan stage: 3 Acknowledgement/ filter change: 4 Operation in pairs: 5 Permanent intensive brief ventilation operation: Snooze function: When the device is switched off, the fan continues to run for a short period of time. If this key is pressed repeatedly, the fan stages 1 4 are run through. The fan stage currently set is shown in the LED display (6). The end of the maintenance interval for the dust filter is signalized by the LED. The display will be reset if the key is pressed for 5 seconds after the filter change. Heat recovery mode, normal operating condition in the fan stages 1 4. If this key is pressed, the ventilation system jumps to a permanent intensive brief ventilation mode which allows the ventilation of a room without opening the windows. For this purpose, stage 4 is set automatically. The control unit is provided with a snooze function by means of which the system can be started with a delay of 60 minutes. Set the desired operating mode and fan stage. Keep the keys 3 and 5 pressed for at least 3 sec. (press key 3 first) ->only the LED of the operating mode set (4 or 5) is lit. Press the keys (2), (4) or (5) to terminate the snooze phase prematurely. 6

2.2 SEC-Basic and SEC-20-BF Device On/Off: 2 Selection of the fan stage: 3 Acknowledgement/ filter change: 4 Operation in pairs: When the device is switched off, the fan continues to run for a short period of time. If this key is pressed repeatedly, the fan stages 1 4 are run through. The fan stage currently set is shown in the LED display (6). The end of the maintenance interval for the dust filter is signalized by the LED. The display will be reset if the key is pressed for 5 seconds after the filter change. Heat recovery mode, normal operating condition in the fan stages 1 4*. *depending on the device type; see page 8 5 Permanent intensive brief ventilation operation: Snooze function: If this key is pressed, the ventilation system jumps to a permanent intensive brief ventilation mode which allows the ventilation of a room without opening the windows. For this purpose, stage 4* is set automatically. *Configuration 3-6: If activated, all fans connected run automatically inair dischargemode (see p. 8 et seqq.). Intensive brief ventilation is to be set correspondingly via (2)! The control unit is provided with a snooze function by means of which the system can be started with a delay of 60 minutes. Set the desired operating mode and fan stage. Keep the keys 3 and 5 pressed for at least 3 sec. (press key 3 first) -> only the LED of the operating mode set (4 or 5) is lit. Press the keys (2), (4) or (5) to terminate the snooze phase prematurely. 7

2.2.1 Determining the device type when using SEC-Basic The SEC-Basic offers the possibility to connect different device types of the SEVi series with different configurations. Depending on the device type, various programmes are implemented in the software. They are described in the following. Currently, three different configurations are available. To select them, the keys (4) Alternating operation and (2) Fan stage are to be pressed simultaneously for ca. 5 seconds. Then, the LED display (6) flashes (see Table). To change the configuration, the key (2) Fan stage is pressed to select another configuration (the corresponding LEDs flash). You can exit the selection mode by keeping the keys (4) Alternating operation and (2) Fan stage pressed again for ca. 5 seconds. Note: The configurations 4 to 7 (indicated by the LED 4 or LED 1+2, 1+2+3, 1+2+3+4) are reserved for later assignment! Configuration Fan type Indicated by LED 1 SEVi 200 (DIBt) SEVi 160 sound-optimized operation at stage 1 2 SEVi 160 (DIBt) 2 3 SEVi 160 air discharge Stage 4 is designed purely as anair discharge solution in which all fans connected are operated at the highest air discharge stage (irrespective of the connection on the operator control unit). Note: Sufficient air must come in for pure air discharge operation! *Configuration 3: If this configuration is selected, all fans connected are automatically running (irrespective of their terminal assignment) in air discharge operation. Intensive brief ventilation at stage 1-3 must be correspondingly set via (2)! 1 3 2.2.2 Determining the device type when using SEC-20-BF The central control unit SEC-20-BF can be used for operating the fans of the SEVi 200 and SEVi 160 series. Moreover, the SEVi 160DUO MINI (available from autumn 2016) can be operated by using the SEC-20-BF.In addition to this, the central control unit can also be used as a humidity sensor. 8

Determining the device type- The SEC-20-BF offers the possibility to connect different device types of the SEVi series with different configurations. Depending on the device type, various programmes are implemented in the software. They are described in the following. To select them, the keys (4) Alternating operation and (2) Fan stage are to be pressed simultaneously for ca. 5 seconds. Then, the LED display (6) flashes (see Table). To change the configuration, the key (2) Fan stage is pressed to select another configuration (the corresponding LEDs flash). You can exit the selection mode by keeping the keys (4) Alternating operation and (2) Fan stage pressed again for ca. 5 seconds. (2) (4) (6) Configuration Device type Indicated by LED In the configurations 1 through 3, a difference is only made between air incoming side and air discharge side! All four terminals can be allocated by devices of the SEVi 200/SEVi 160-series! In the configurations 1 to 3, an allocation with SEVi 160DUO MINI is not possible! 1 SEVi 200 (DIBt) SEVi 160 sound-optimized operation at stage 1 2 SEVi 160 (DIBt) 2 3* SEVi 160 air discharge Stage 4 is designed as a pure air discharge solution in which all fans connected are operated at the highest air discharge stage (irrespective of the connection on the operator control unit). Note: Sufficient air must come in for pure air discharge operation! *Configuration 3: If stage 4 is activated, all fans connected are automatically running (irrespective of their terminal assignment) in air dischargeoperation. Intensive brief ventilation at stage 1-3 must be correspondingly set via (2)! In the configurations 4 to 7, attention is to be paid additionally to the allocation of the top and bottom terminal strips! The SEVi 160DUO MINI can only be operated via the bottom terminal strip. 1 3 9

The configurations 4 to7 are provided for the common operation of the devices of the SEVi 200/160 series and SEVi 160DUO MINI devices! 4 top SEVi 160 sound-optimized operation at stage 1 bottom SEVi 160DUO MINI- Stage 4 is designed as a pure air discharge solution in which the two fans are operated at the highest air dischargestage (irrespective of the connection on the operator control unit). 4 5 top Note: SEVi 160 (DIBt) Sufficient air must come in for pure air discharge operation! bottom SEVi 160DUO MINI -Stage 4 is designed as a pure air discharging solution in which the two fans are operated at the highest air discharge stage (irrespective of the connection on the operator control unit). 1 + 2 top Note: Sufficient air must come in for pure air discharge operation! SEVi 160 air discharge- Stage 4 is designed as a pure air discharging solution in which all fans connected are operated at the highest air discharge stage (irrespective of the connection on the operator control unit). 6 7 Note: Sufficient air must come in for pure air discharge operation! bottom SEVi 160DUO MINI - Stage 4 is designed as a pure air discharge solution in which the two fans are operated at the highest air discharge stage (irrespective of the connection on the operator control unit). top Note: SEVi 160 (DIBt) Sufficient air must come in for pure air discharge operation! bottom SEVi 160DUO MINI 4-stageHRS operation 1 + 2 + 3 1 + 2 + 3 + 4 10

The SEC-20-BF central control unit can be optionally operated with or without humidity control. The humidity control distinguishes between five different statuses: Status Indication by LED in setting mode Humidity threshold (RH%) Humidity control All LEDs off - off 1 LED fan stage 1 flashes 50 2 LED fan stage 2 flashes 55 3 LED fan stage 3 flashes 60 4 LED fan stage 4 flashes 70 To activate the humidity control or to set another humidity threshold, the following steps are to be taken: Keep the Alternating operation and Filter change keys pressed for 5 seconds. The control unit changes to the activate /deactivate mode. The statuscurrently set is indicated by the LED of the fan stages (see Table). If the Fan stage key is pressed, the desired status of the humidity control can be selected. If the Alternating operation and Filter change keys are pressed anew for at least 5 seconds, the setting selected will be stored. Afterwards, the control unit returns to normal operation. Note to humidity control: In the activated mode of the humidity control, the room humidity is continuously measured. If the value which has been set for the humidity threshold is exceeded, the fan stage of the fans connected is increased by one stage until fan stage4 is reached. The stages are gradually increased at 15-minute intervals. If the value measured is lower than the humidity threshold set (minus a hysteresis of about 5%), the fan stage is decreased gradually again down to stage 1. The manual change of the fan stage is still possible. However, the manual setting will be corrected at 15-minute intervals if the humidity control is switched on. Delivery status: configuration 1, humidity control off 11

3. Maintenance and service Danger: All works shall only be carried out when the system is in de-energized condition! 3.1 Maintenance intervals Check for impermissible contamination, damage (leakage) and smell every 12 weeks -->Change the corresponding filters, if required, Dust filter indication by control unit LED, (interior panel) Filter change at least every 12 months (4 x filter interval) Optional pollen filter (interior panel) Heat accumulator Change after 12 months, indication by control unit LED Cleaning required every 24 weeks, indication by control unit LED (2 x filter interval) compressed air washer vacuum cleaner Ventilator Cleaning of the blades required every 12 months soft, moistened cloth brush Sound insulation element (fan unit) Cleaning required every 24 weeks Rinse under running water, not leave in the water, installation only in completely dry condition 12

3.2 Maintenance guidelines Changingthe dust or pollen filters/sound insulation element Dust filter (in the interior panel): 1. Remove or disassemble the complete interior panel from the fixation tube. 2. Remove the dust filter out of the filter support and change the dust filter. 3. Assemble the interior panel and mount it in the fixation tube. Sound insulation element: 1. Demount the interior panel completely and disconnect the plug connection. Then, the fan unit can be taken out of the fixation tube by using the pullingout loop. Opening upwards 2. Lift the upper part upwards (remove the possibly existing fixation). 3. Exchange/clean/insert anew Caution:Heat accumulator can have sharp edges! To avoid injuries, suitable gloves must be worn! 4. Put on the upper part; position the protection grid (add the possibly existing fixation) and slide the fan unit into the fixation tube. Note: When putting on the EPP upper part, the correct position of the decoupling strip at the ventilator must be ensured! Note: When the fan unit is inserted into the fixation tube, it must be ensured that the condensation discharge is positioned at 6 o clock! 13

Removing the heat accumulator and the ventilator unit 1. Demount the interior panel completely and disconnect the plug connection. Then, the fan unit can be taken out of the fixation tube. 2. Remove the upper part (lift it upwards (remove possibly existing fixation). 3. Remove the sound insulation element, heat accumulator and fan. Caution: Heat accumulator can have sharp edges! To avoid injuries, suitable gloves must be worn! 4. Installation: After cleaning, insert the heat accumulator, sound insulation element and fan into the EPP lower part. When doing this, pay attention to the position of the cables! Note: When inserting the fan and putting on the EPP upper part, the correct position of the decoupling strip at the ventilator must be ensured! When inserting the unit into the fixation tube, it must be ensured that the condensation discharge is positioned at 6 o clock! 14

3.3 Fault tracking Danger: All works shall only be carried out when the system is in de-energized condition. Error Cause of error Troubleshooting Failure of fan System too loud Air volume flow too low No power Installation error Ventilator defect Dirty ventilator blades Dirty filter/heat accumulator Decoupling tape incorrectly inserted Interior panel closed Dirty pollen/dust filter Dirty heat accumulator Check the fuse, switching on/off at the control unit Check connections Check distributor board or humidity sensor Change of ventilator Cleaning Change/cleaning Check for correct position Open by turning the upper part by 180 Change Cleaning 15

Maintenance of the device Interval (LED display) Dust filter/pollen filter Accumulator/sound element Ventilator 16

Interval (LED display) Dust filter/pollen filter Accumulator/sound element Ventilator 17

Comments: 18

EC Declaration of Conformity The company SEVentilation GmbH E.-Thälmann-Str.12-14 07768 Kahla Germany declares under its sole responsibility that the products: of type: SEVi 200 / SEVi 200U / SEVi 200L /SEVi 160 / SEVi 160DUO / SEVi 160U / SEVi 160L / SEVi 160R / SEVi 160CE / SEVi 160RO / SEVi 160ALD / A160 (decentral ventilation devices with and without heat recovery), to which this declaration refers, comply with the following standards and normative documents: EN 55014-1; 2006 EN 55014-2; 1997, +A1; 2001 EN 61000-6-1, 2007; Generic StandardsEMC Immunity EN 61000-6-3, 2007; Generic StandardsEMC Emission Standard EN 61000-3-2, 12.2001; Low-Frequency System Perturbation EN 61000-3-3, 1.1998 EN 60335-1, EN 60335-2-65; (safety of household and similar electrical appliances) according to the provisions in the Directive 2004/108/ECor (EMC 2008), the Directive 2006/95/EC (Low Voltage Directive) and the RoHS Directive 2002/95/EC. The decentral ventilation systems: SEVi 200 / SEVi 200U / SEVi 200L /SEVi 160 / SEVi 160DUO / SEVi 160U / SEVi 160L / SEVi 160R / SEVi 160CE / SEVi 160RO / SEVi 160ALD / A160 with and without heat recovery are used for the ventilation of apartments/accommodation units. Kahla, 10/12/2015 Dipl.Wirt.Ing. (FH)* Nico Schellenberg *Graduate Industrial Engineer 19

Production: SEVentilation GmbH E.-Thälmann-Str. 12 07768 Kahla Germany The manufacturer reserves the right to change technical details! Telephone: +49 36424 767472 Fax: +49 36424 767471 Email: info@seventilation.de 20