NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Similar documents
Smart THERMOSTAT. Installation Manual

2 x screws. 2 x wall plugs

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Optima ZigBee Thermostat

ShockLink. Important Product Information.

Smart Hub THERMOSTAT. Installation Manual

Rev D 3/20/17

Wi-Fi DOOR/WINDOW SENSOR

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Automatic Dimming Mirror with HomeLink

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

SZ-PIR04N ZigBee Motion Detector Installation Guide

Wireless Weather Station

ADT. Pulse 2017ADT LLC

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Wireless External Alarm

Atomic Digital Office Clock

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Touchscreen Comfort Control

1100D Wireless Receiver

InTemp CX Temperature Logger (CX40x) Manual

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

ecobee 3 Quick Start Guide Installation Guide DRAFT

Wireless Outdoor Air Reset Adaptor PN:

1100X Wireless Receivers

Water Sensor. Model CFWS10

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

PET IMMUNE PIR MOTION DETECTOR

Intelli-Time Alarm Clock model 13041RM

EL-TSTAT Owner s Manual

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Features and content. This is where air comes into your detector.

Pet Immune SAW PIR Motion Sensor

Impassa CDMA Module INSTALLATION GUIDE

Smart Radon Detector with Indoor Air Quality Sensors

TX3 Series. TX3 InSuite. User Guide

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Draft - develop and review

Smoke Bridge Owner s Manual

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

Caught a critter in the act?

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 6 Mounting 7 Probe Use 8 Probe Wrap Use 9

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

HOBO MX Temp/RH Data Logger (MX1101) Manual

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

EN1221S-60 Waterproof Pendant Installation and Operation Manual

OPTIMA ZigBee Thermostat

S541.RF 4G Product Guide

Technical support is also available by or by phone: (North America) (International)

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

180 Degree Ceiling Mounted Occupancy Sensors

Save these instructions This product is for household only

Installer Guide smart connect

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

GLAS. Installation Instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Enhance Your Assembly Experience. Intended Use...

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

Door/Window Sensor Installation Instructions

Atomic Digital Wall Clock

How to install your ecobee4

Installer Guide smart connect

Yale Real Living Touchscreen Lever Installation and Programming Instructions (YRL220)

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

PRODUCT DIAGRAM PACKAGE CONTENTS

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

USER S GUIDE. Smart Humidifier. Model: MBP86SN. The features described in this guide are subject to modifications without prior notice.

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

programmable control model installation and setup guide M /11/ Hunter Fan Company

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

Install Guide TP-2014-IG-V02

Little Anne. Important Product Information

XL200L/600L/700L GPRS Control Panel

Tech Support Line: (715) Concord 4 RE927X

FTS05 / FTS05P - Wireless Flood and Temperature Sensor, User Manual

Blueair C User Manual

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

Projection Alarm Clock

Failure to comply with the following instructions may result in death or serious injury to

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

1164/1164NS WIRELESS SMOKE DETECTOR

Transcription:

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE INSTALLATION AND OPERATION INSTRUCTIONS MODEL NUMBER NXSMP-LMI PRECAUTIONS Read and understand all instructions before beginning installation. CAUTION: FOR USE WITH CLASS 2, LOW VOLTAGE SYSTEMS ONLY. DO NOT USE IN HIGH VOLTAGE APPLICATIONS. NOTICE: Class 2 Device, 12-24V, 10mA NOTICE: Suitable for Use in Other Environmental Air Space (Plenums) in Accordance with Section 300.22, (C) of the National Electrical Code. NOTICE: For installation by a licensed electrician in accordance with National and/or local Electrical Codes and the following instructions. Confirm device ratings are suitable for application prior to installation. Use of device in applications beyond its specified ratings or in applications other than its intended use may cause an unsafe condition and will void manufacturer s warranty. Use only approved materials and components (i.e. wire nuts, electrical box, etc.) as appropriate for installation. NOTICE: Do not install if product appears to be damaged. FCC ID: YH9NXSMP IC: 9044A-NXSMP This device complies with FCC part 15 Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, 2. This device must accept any interference received, including interference that may cause undesired operation. FCC Interference Statement (Part 15.105 (b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. FCC Part 15 Clause 15.21: Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. ISED RSS-Gen Notice: This device complies with Industry Canada s licence-exempt RSSs. Operation is subject to the following two conditions: 1. This device may not cause interference; and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes: 1. l appareil ne doit pas produire de brouillage; 2. l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. SAVE THESE INSTRUCTIONS! 1

DESCRIPTION The NXSMP-LMI is a combination PIR occupancy sensor and closed loop daylight sensor specifically designed for installation within a lighting fixture or ceiling tile. When used with the appropriate NXFM fixture module, the NXSMP-LMI can be programmed to provide automatic On/ Off control based on occupancy and/or automatic light level control based on the amount of ambient daylight. An integral Bluetooth radio enables the NXSMP-LMI to be programmed locally using the NX Room Setup App on an Android or ios smart device. FOR INDOOR APPLICATIONS ONLY! INSTALLATION Note: The NXSMP-LMI is designed to mount on a flat surface in a round opening measuring between 1 3/16 and 1 1/4 in diameter. 1. Choose a mounting location on the fixture where the sensor lens will be oriented downward as close to level as possible. Use the supplied locking ring and gasket to secure the sensor in place. Do not over tighten the locking ring. 2. Plug the appropriate end of the supplied cable into one of the miniature 5 pin receptacles on the back of the sensor. Note that two receptacles are supplied to allow for additional NX modules to be connected in series. 3. Plug the other end of the cable into the RJ45 port on the NXFM fixture module. 4. Peel one of the supplied MAC address labels from the sensor body and apply it to the outside of the fixture in a position where it is visible from below. This label will be used by the technician during calibration of the sensor and later removed. 5. Assemble or reassemble the fixture as required. 6. Recommended mounting height for the sensor in the final installation is 8 to 12 ft. AFF (Above Finished Floor). Maximum mounting height is 14 ft. Minimum mounting height is 8 ft.

MOUNTING DETAIL Fixture Mount Ceiling Mount HOLE DETAIL Ø 1.25 SETUP AND CALIBRATION For setup and calibration instructions please visit http://cdn.hubbell-automation.com/content/products/instructions/instructions_files/nx_ Setup _Calibration_Guide.pdf or scan the QR code. 2

WIRING DIAGRAMS NXSMP-LMI with NXFM-1R2D-O-UNV NXSMP-LMI with NXFM-1R2D-I-UNV 3

NXSMP-LMI with NXFM-LV 4