PULSACOIL 2000 USER GUIDE. TEL:

Similar documents
PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS

PULSACOIL A CLASS USER GUIDE. TEL:

BOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers

systemate 2000 fully integrated thermal store

BOILERMATE A CLASS SP

BOILERMATE A CLASS OV

UNIT 5 COLD WATER SUPPLY

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Total Hot Water Solutions

THERMAL STORE MAINS PRESSURE SYSTEM

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Risk Assessment and Control Measures for Household Hot Water Systems

Description of the property and water systems:

Pressure Boosting Solutions

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Harlequin HeatStream Case Study

FREQUENTLY ASKED QUESTIONS

25 per cent of energy used in the home is used to heat water.

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

VENTED CYLINDER RANGE

Kills bills. How Vaillant technologies reduce home heating bills

THERMAL STORE MAINS PRESSURE SYSTEM

Unvented Hot Water Criteria

Energy Ambassadors Guide

AN ENERGY SAVING ADDITIVE FOR CENTRAL HEATING SYSTEMS

Legionella Policy and Procedure

Installation, Operating and Servicing Instructions

Hot water This guide will help you choose the right hot water system for your home and show you how to reduce your hot water costs.

ADVANCE ECB ELECTRIC COMBINATION BOILER

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Legionnaires Disease Risk Assessment

Performance on demand

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Operation & Installation Manual

Home owner user pack for the Nibe 200P

Energy and you. A guide to energy efficiency in your home. Energy and You A5.indd 1 26/10/ :15

Installation, Operating and Servicing Instructions

Operation / Installation Manual

Morco House Riverview Road Beverley HU17 0LD

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Section 7 F/602/2884 Understand and apply domestic hot water system installation and maintenance techniques

Helping you understand your water usage

For use with approved Bathstore head kits. Installation guide. Viso Digital installation instructions Page 1

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

Combi Konverter Solar System

Welcome to your new home

Dene Bath Shower Mixer

THERMOSTATIC SHOWER VALVE

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Morco House Riverview Road Beverley HU17 0LD

ADVANCE ELECTRIC THERMAL STORE

Dove Eco thermostatic bar mixer shower

The world s most advanced direct electric water cylinder

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

Bath Shower Mixer

Understand and apply domestic hot water system installation, commissioning, service and maintenance techniques

Installing, modifying and maintaining domestic plumbing systems. Water Supply (Water Fittings) Regulations 1999

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

RHEEM CONTINUOUS FLOW GAS HOT WATER YEAR WARRANTY ENERGY L/MIN GAS HOT WATER THAT NEVER RUNS OUT. factor COMES ON STEADY, HOT AND STRONG INSTALL A

Saving Energy. We promote equality of opportunity in every aspect of our business in line with our objectives.

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Installer & User Guide Effective February 2013

WATER DOMESTIC PROPERTIES REGULATIONS FOR. Information guide for your home

Torrent GreenHeat. Design, Installation & Servicing Instructions. Open vented thermal store providing heating and mains pressure hot water

What is solarcache touch? How does it work? What can I see on the screen?

1 Day to Day Repairs

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

THERMOSTATIC MIXING VALVES

Larch house and Lime house review of systems design and implementation

High Output Boiler Systems

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

PULSACOIL 2000 DESIGN, INSTALLATION AND SERVICING INSTRUCTIONS. TEL:

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

IT S NOT JUST SOLAR IT S SOLAHART

CT range. of shower, bathroom and whole house pumps

Water Supply (Water Fittings) Regulations 1999

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

FlowSmart. The high efficiency, high performance space saving heating system.

Roof Mount Solar Hot Water System USER MANUAL

FERVORE thermostatic mixer shower Installation and operating instructions

STAY WARM STAY HEALTHY

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Leaseholder Energy Efficiency November 2011

GREEN TIPS SAVE MONEY, SAVE THE ENVIRONMENT

TORRENT ECO INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

Where gas is not an option,

Hot water service. Energy. Water heaters. Hot water service. Storage water heaters

GB24 & GB30. User Manual

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

PulsaCoil Stainless. Design, Installation & Servicing Instructions. Hot water cylinder utilising off-peak electric. Models covered in this manual

Hot water temperature maintenance systems in hospitals

Frequently Asked Questions

Water Heater Mixing Valve

Installation & Technical Guide. Domestic & Commercial.

Installation Instructions and User Guide. Tel : NEWTEAM 1500-XT THERMOSTATIC POWER SHOWER

Index. Introduction. Pg 2. Powersaver - Single Element. Pg 3-5. Powersaver - Dual Element. Pg 6-11

Transcription:

PULSACOIL 2000 USER GUIDE Gas Council Approved Reference Numbers PulsaCoil 145 97-317-32 PulsaCoil 185 97-317-33 PulsaCoil 215 97-317-34 PulsaCoil 235 97-317-35 A mains pressure hot water supply system incorporating an off peak electric thermal store TEL: 0800 14 55 55 7 www.pulsacoil-2000.co.uk

Issue 6 : November 2004 WELCOME TO YOUR THERMAL STORAGE SYSTEM PULSACOIL 2000 - THE POWER BEHIND YOUR DOMESTIC HOT WATER The hot water in your home is provided by a high specification storage system which will give you many benefits. Simple to operate and exceptionally efficient in operation, your PulsaCoil 2000 Thermal Store is probably different to any water heating system you have ever experienced before. This booklet will explain why and how you can get the most from it. Page 2 OPERATING CHARACTERISTICS - with a PulsaCoil 2000, the domestic hot water you use at the tap is not stored but is produced instantaneously. This has the advantage of reducing the risk of contamination from things like Legionella as well as reducing the risks of scalding by allowing the temperature of the hot water at the tap to be controlled at about 55ºC. However, this also means that when you open the tap, the temperature takes a little time to stabilise. - the reason is simple; tepid water in the house pipework arrives at the tap first. Then the system senses that a tap has been opened so heat exchange is started and the domestic hot water will go fully hot to sterilise the pipework. Following that the controller will kick in and the supply will settle at 55ºC (approximately). - water should not be delivered to the tap below 50ºC for health reasons; see HS (G) 70 HTM 2040.

This system delivers fresh water from the mains supply to the hot taps and is designed to fulfil three basic needs. 1. Deliver hot water at good pressures whenever you need it 2. Operate as efficiently as possible to cost-effectively meet your household needs 3. Provide hot water to every tap that has not deteriorated in storage tanks Page 3 THIS APPLIANCE SHOULD BE LEFT PERMANENTLY CONNECTED TO THE OFF-PEAK ELECTRICAL SUPPLY AND NOT SWITCHED ON AND OFF WHEN HOT WATER IS NEEDED. PULSACOIL 2000 MODELS (EXCEPT MODEL PC125) ALSO HAVE AN ON-PEAK BOOST WHICH CAN BE SWITCHED ON FOR AN HOUR AT A TIME TO PROVIDE A BOOST TO THE TOP PART OF THE STORE ON DAYS WHEN A LARGE AMOUNT OF HOT WATER IS REQUIRED. PULSACOIL

1. DELIVER HOT WATER AT GOOD PRESSURES WHENEVER YOU NEED IT Your Thermal Storage System is designed to provide all the hot water you are likely to need under normal circumstances, and deliver that hot water at a pressure comparable with your cold water mains. This means that you can enjoy powerful showers without the need for a separate pump, or fill a bath with hot water in minutes. 2. OPERATE AS EFFICIENTLY AS POSSIBLE TO COST-EFFECTIVELY MEET YOUR HOUSEHOLD NEEDS Your Thermal Storage System will ensure that the energy it needs is minimised, avoiding costly use of fuel by taking advantage of off-peak tariffs whenever they are available. Hot water is available any time you need it when the system is switched on, summer or winter. 3. DELIVERING HIGH QUALITY WATER TO EVERY TAP With traditional systems which have a cold supply cistern in the roof space, there is always the risk that the tank could become contaminated by dust, birds or insects. The PulsaCoil is connected directly to the cold mains and therefore even the hot supply is pure high quality water every time. Page 4

WHAT IS A THERMAL STORE? The Gledhill Thermal Store is the heart and brain of your hot water system. It stores hot water at a constant temperature and incorporates a highly efficient plate heat exchanger which heats the hot water for all your domestic needs. The Thermal Store is superbly insulated and so the hot water stored has a very low heat loss. Off-peak supplies will automatically be used to heat the thermal store. You will also have the option* to switch on to the on-peak electricity supply when necessary to provide a boost to the top part of the thermal store to achieve the most efficient way of satisfying your demands on the system. HOW DOES THE SYSTEM DELIVER HOT WATER AT HIGH PRESSURE? Page 5 The water delivered to the taps and showers in your home is supplied at high pressure because it uses the mains pressure of your cold water supply. The PulsaCoil is connected to the mains system and the water passes through a highly efficient heat exchanger to raise its temperature before it travels to your taps and showers. Because it is so efficient, both high flow rates and high pressures are available to give the best performance for both baths and showers. PULSACOIL

WHY ARE THERE NO WATER CISTERNS IN THE LOFT Water tanks in the loft are required principally for the traditional domestic hot water system to give a better head of water - which is basically determined by the height of the cistern above the tap being used. In most cases, the higher the cistern, the greater the pressure. Because the Gledhill system uses the pressure from your cold water mains, these cisterns are not required. This removes any worries about freezing or contamination of the cold water system from insects, dust, birds etc and leaves more space for storage should you decide to use it. PLASTIC FEED TANK The plastic feed tank should have been filled to the water line by the installer at the time of commissioning. The water level in the plastic feed tank should be checked on a regular basis, generally 3-4 times a year, and topped up when necessary to approximately half way. Once the level has been topped up or after it has been checked, ensure the lid has been securely replaced. An optional sight glass can be fitted to the side of the feed tank, to overcome the need to remove the lid to check the water level. Page 6

WHAT IF THE SYSTEM DEVELOPS A FAULT? If your PulsaCoil should develop a fault, during the warranty period, switch the unit off and contact your house manager/installer. Do not attempt to remove or adjust any component part yourself. If the developers warranty has expired contact the manufacturer if you have an active Service Agreement. REMINDER! The off peak controller adjacent to the PulsaCoil will have a manual boost switch/facility. This should be switched on for an hour during late afternoon to provide a boost to the top part of the Thermal Store on days when a large amount of hot water is required. If you are considering changing your electricity supplier it is important that you ensure they are able to provide at least the same tariff. If not the operation and cost of running the appliance will be affected. Page 7 PULSACOIL

Sales, Service & Repair PulsaCoil 2000 C/O Hot Water Cylinders Limited 302 Foxhunter Drive Milton Keynes MK14 6GD TEL: 0800 14 55 55 7 www.pulsacoil-2000.co.uk