International Gas Union Research Conference Limitation of detection range in guided wave testing of buried pipeline

Similar documents
Long-range Ultrasonic Non-destructive Testing of Fuel Tanks

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

DUAL MODE PULSE REFLECTOMETRY

NOVEL BOREHOLE- AND TEST PROCEDURES FOR UNDERGROUND GAS STORAGE ASSETS BY USING AN INTELLIGENT PIG FOR DOWNHOLE INSPECTIONS

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

6 th Pipeline Technology Conference 2011

Application of Golay Coded Pulse Compression in Air-coupled Ultrasonic Testing of Flexible Package Seal Defect

DETERMINATION OF THE EFFECTIVE MOISTURE DIFFUSIVITY OF RED PEPPER IN A MICROWAVE CONVEYOR DRYER

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Performance Analysis of Water-Water Heat Pump System of 100 kw Scale for Cooling Agricultural Facilities

DEGRADATION OF OPTICAL FillERS AT CARBON-CARBON PYROLYSIS. Rockwell International Science Center P.O. Box 1085 Thousand Oaks, CA 91358

Brine Generation Study

Fire Test Evaluation using the Kerosene and Aviation Fuel

Contents. EN :2012 (E) Issue 5 ( ) Page

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Distributed Condition Monitoring of Power Cables a Brief Update

FREQUENCY SHIFTING SIGNAL DETECTION AND ANALYSIS OF BOILER TUBE LEAKS

Modelling the Performance of a Diffusion Absorption Refrigeration System

International Journal of Advanced in Management, Technology and Engineering Sciences

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

INCREASED RELIABILITY / REDUCED RISK BY APPLYING INTELLIGENT PIGGING TECHNOLOGY TO INSPECT COILS IN PROCESS HEATERS

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

The application of Long Range Ultrasonic Testing (LRUT) to inspect railway tracks

This paper will discuss the leak detection technologies that have been adapted to detect thefts and secure accurate tapping point locations.

Thermal Performance of a Loop Thermosyphon

AFMG. Design for Speech Intelligibility Using Software Modeling. Stefan Feistel, Bruce C. Olson AHNERT FEISTEL MEDIA GROUP

ProStar 325 UV-Vis Detector

Laboratory study of the effects of green roof systems on noise reduction at street levels for diffracted sound

Department of MCE, Islamic University of Technology 2. Abstract

Operation of a Two-Phase Reverse Loop Thermosyphon

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

An experimental study of the impact of tunnel suppression on tunnel ventilation

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

COMPARING PLASTIC STAKING TECHNOLOGIES

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Deployment of Cellular-Based Ultrasonic Corrosion Measurement System for Refining & Petro- Chemical Plant Applications

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

Performance of CO2 Cycles with a Two-Stage Compressor

EFFECT OF BOLT CONNECTION OF SQUARE-SHAPED GEOCELL MODEL ON PULLOUT TEST RESULTS

DISTRIBUTED FIBRE-OPTIC SENSING FOR LONG-RANGE MONITORING OF PIPELINES

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

A STUDY ON LOAD CAPACITY OF HORIZONTAL AND INCLINED PLATE ANCHORS IN SANDY SOILS

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

RaySense. Fiber Optic Distributed Vibration Sensing (DVS) for Pipeline Security and Leak Detection

WHAT IS LASER ULTRASONIC TESTING?

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Solar Drying Techniques And Performance Analysis: A Review

Effect of Vacuum Cooling Operation Parameters on Cooling Time and Weight Loss of Chinese Cabbage

A Study on Hierarchy of Spatial Configuration in Outpatient Department of General Hospital

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

EXPERIMENTAL STUDY ON PULL-OUT CAPACITY OF HELICAL PILE IN CLAYEY SOIL

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

Compressor Explosion Accident at Pump-Down of Air Conditioners

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Fire Detection Using Image Processing

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Classification of drying methods for macadamia nuts based on the glcm texture parameters Simon N. Njuguna 1,2, Stephen Ondimu 2, Glaston M.

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

RaySense. Fiber Optic Distributed Acoustic Sensing for Pipeline Security and Leak Detection

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Evaluation of the Red Jacket Fx1, Fx2, Fx1V and Fx2V Line Leak Detectors For Hourly Monitoring on Rigid Pipelines. Final Report

A Study on Anti-Loosening Characteristics of Different 3/8 BSW Threaded Fasteners

Non-destructive inspection method for concrete elements in tunnel linings using laser remote sensing

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Effect of Impeller Clearance and Multiple Impeller Combinations on Solid Suspension in a Standard Flat Bottom Agitated Vessel

AMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM

Flexibility, scalability andsecurity

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Experiment Study in Optical Fiber Temperature Monitoring

Australian Journal of Basic and Applied Sciences. Leak Detection in MDPE Gas Pipeline using Dual-Tree Complex Wavelet Transform

Equipment Based on NDT Technique and Used in Security and Safety Provision Systems

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Effect of Placement of Footing on Stability of Slope

Transmissivity of a Nonwoven Polypropylene Geotextile Under Suction

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Transcription:

International Gas Union Research Conference 2014 Limitation of detection range in guided wave testing of buried pipeline Main author Kim, YoungGeun South Korea Co-author Song, HongSeok South Korea 1

ABSTRACT As guided wave test is one of the promising inspection methods for the integrity of plant facility, it could be also a promising tool for inspecting buried pipeline. However, guided wave tends to leak into soil rapidly, and the coating of buried pipe also decreases the signal significantly. There has been ambiguity in detection range limit in buried pipe application. In this work, two types of sensor, magneto-striction sensor and piezoelectric sensor were applied to the buried pipeline test loop. The test loop with standard defects at various lengths was constructed at burial depth of 1.5 m. The results showed that the detection range is of 5~10 m. The magneto-striction sensor showed better S/N ratio at the results. But the lack of circumferential resolution limited the interpretation of signal. The piezoelectric sensor showed lower S/N ratio with circumferential resolution. The results showed the possibility of the method and the limitation together. The method was applied to existing valve station. It reveals several indication of metal loss at the unpiggable sections. The results were shown in this work. 2

1. INTRODUCTION The integrity of gas transmission pipes could be maintained by utilizing various inspection tools. The most powerful tool will be inline inspection pigging tool. However many pipes are unpiggable due to the structure of pipe system or other operation issues. The conventional maintenance practice for unpiggable pipe is the direct assessment of the pipelines. The use of RBI (Risk Based Inspection) methods helps to find the most critical parts of a given pipeline network. However many operation want to find more reliable method. The guided wave is regarded as a promising inspection method for the plant. The inspection range of the method reaches around 100m under favorable conditions. However the inspection range of buried pipe is limited by absorption of wave energy by pipeline coating and surrounding soil. Several authors reported the application of the guided wave method to buried pipe (1, 2). There is ambiguity in detection range limit in buried pipe application. The range of detection varied with applied coating and burial depth of pipe. And the detection ranges of the buried pipe were usually estimated by detection capability of girth weld not the real defects. In this work two types of sensor, magneto-striction sensor and piezoelectric sensor were applied to buried pipe line test loop. The test loop was constructed with defects at various lengths with burial depth of 1.5 m. ln this work it is tried to evaluate detection limit under real construction environment. The guided wave technology was also applied to unpiggable secton of pipe in existing valve station. The applicability of this technology was estimated. 2. TEST PIPELINE APPLICATION The test pipes of 8 inch diameter were constructed at sites (figure 1). The artificial defects were machined along the pipe. The defects were designed to have about 5% and10% cross-section area at each pipe (figure 2). The details of the test pipes were shown in table 1. Table 1. Test pipe details Pipe Specification diameter 8 inch thickness Straight 9.5mm Elbow 12.7mm Coating 3.2mm PE materials API 5L x42 Defects 5% Cross-section Straight DxCxA=5x58x10 mm D: Depth C:Circumferential length A:Axial length 3

5% Cross-section Elbow DxCxA=5x78x10 mm 10% Cross-section Straight DxCxA=5x116x10 mm 10% Cross-section Straight DxCxA=5x168x10 mm Figure 1. Test pipe installation and artificial defects The pipes were inspected with piezoelectric sensor type tool (GUL Co. G3) and magneto-striction type sensor (Digital Ultrasonic Co.) before burial. And the trench was backfilled with soil except for measuring holes (figure 2). Schematic diagram of test loop pipeline with defects relative to measuring points is shown in figure 3. Figure 2. Test pipes and holes for measurement Figure 3. Location of welds and defects at the test pipe 4

(W: weld, D: defect, MP: measuring point) Figure 4. Installation of magnetostriction type sensor Figure 5. Installation of piezoelectric type sensor The sensors applied to the test pipeline before burial are shown in figure 4 and figure 5. The typical signals taken before burial were shown in following figure 6 ~figure 7 and signals after burials in figure 8 ~figure 9. The signals taken after burial decays faster compared to respective sensor s signal results before burial due to the thick PE coating. Weld and defects signal could be identified up to about 10m range. The signal to noise ratio by magneto-striction sensor is much higher. The piezoelectric sensor showed circumferential resolution which magneto-striction sensor doesn t have and enabled to distinguish between weld signal and local defect. This capability is very useful practically when there is not much information about pipeline weld locations. The signal decay became more significant at the result obtained at buried pipes. The observed decay at buried pipe is around 6dB/m at 25 khz. The attenuation rate was known to be frequency dependant. At higher frequency the coefficient became higher (3, 4). The detection ranges were identified and are summarized at Table 2, 3. 5

Figure 6. Inspection results with magnetostriction sensor at measuring point 4 before burial Figure 7. Inspection results with piezoelectric sensor at measuring point 4 before burial 6

Figure 8. Inspection results with magnetostriction sensor at measuring point 4 after burial Figure 9. Inspection results with piezoelectric sensor at measuring point 4 after burial 7

Table 2. Detection range with magnetostriction type sensor (white shade: detectable, gray shade: semidetectable, dark gray shade: undetectable) Defect No. Defect No. (before burial) (after burial) D1 D2 D3 D1 D2 D3 5-2 2.0 4.0 20.3 2.0 4.0 20.3 5-3 12.0 6.0 10.3 12.0 6.0 10.3 5-4 15.0 9.0 7.3 15.0 9.0 7.3 10-2 2.0 4.0 20.3 2.0 4.0 20.3 10-3 12.0 6.0 10.3 12.0 6.0 10.3 10-4 15.0 9.0 7.3 15.0 9.0 7.3 Table 3. Detection range with piezoelectric type sensor (white shade: detectable, gray shade: semi-detectable, dark gray shade: undetectable) Test # %Crosssection/measuring point No Test # %Crosssection/measuring point No Defect No. Defect No. (before burial) (after burial) D1 D2 D3 D1 D2 D3 5-2 2.0 4.0 20.3 2.0 4.0 20.3 5-3 12.0 6.0 10.3 12.0 6.0 10.3 5-4 15.0 9.0 7.3 15.0 9.0 7.3 10-2 2.0 4.0 20.3 2.0 4.0 20.3 10-3 12.0 6.0 10.3 12.0 6.0 10.3 10-4 15.0 9.0 7.3 15.0 9.0 7.3 3. FIELD APPLICATION The field applications of piezoelectric sensor were conducted at sites (figure 10). The following results show that suspected defects was identified successfully as shown in figure 11. The detection range at the field is slightly shorter than the test pipe. It is believed that uneven soil condition and coating degradation induces 8

higher noise level than that of the test pipe. The detection range is also limited by elbows. In the valve station there are too many elbows in short distance which limit detection range. None the less the guided wave technology enables inspection of the pipe which could not be examined without this technology. Figure 10. Inspection with piezoelectric sensor at valve station Figure 11. Inspection results with piezoelectric sensor at valve station (suspected defects at -2m from the measuring point) 4. SUMMARY In this work two types of sensor, magneto-striction sensor and piezoelectric sensor were applied to buried pipeline test loop. The results showed that detection range is of 5~10 m. The magneto-striction sensor showed better S/N ratio at the results. But the lack of circumferential resolution limited the interpretation of 9

signal. The piezoelectric sensor showed lower S/N ratio with circumferential resolution. The method was applied to existing valve stations and reveals several indication of metal loss at the unpiggable sections. The results showed the possiblility of the method and the limitation for the inspection of buried pipeline integrity together. REFERENCES 1. A. Demma, D. Alleyne, B. Pavlakovic, 3rd MENDT-Middle East Nondestructive Testing Conference & Exhibition, 2005, Bahrain. 2. H. Kwun, S.Y.Kim, M.S.Choi,S.M.Walker, Torsional guided-wave attenuation in coaltar-enamel coated, buried piping,ndt&e International, 37,pag 663-665,2004 3. F. Bertoncini, et al., Effect of attenuation on inspection range and sensitivity in long-range guided wave NDT of coated and buried pipes, The e-journal of the nondestructive testing, vol. 11, ISSN: 1435-4934, 2010. 4. F. Bertoncini, M. Raugi, F. Turcu, Magnetostrictive sensors for long range guided wave inspection and monitoring of in-service pipelines, IGRC 2008, Paris, France, October 08-10, 2008 10