Ecodan Aerocyl Plus-me: Air Source Heat Pump and Stainless Steel Cylinder

Similar documents
2012 Heating Price List. Price List Heating 1st November Mitsubishi Electric is a market leader in renewable solutions.

Ventilation. Product Information

Fresh Air Ventilation

Fresh Air Ventilation

Lossnay RVX Fresh Series Air Ventilation

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Information Guide Maintenance and Refrigerant Regulations. Issue 35

Daikin Altherma Small Monobloc User Guide

Baxi Maxflow Combi FS

Daikin Altherma Large Monobloc User Guide

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Daikin Altherma High Temperature User Guide

Central Home Heating and Hot Water Supply

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Commissioning Pack. Heating and Hot Water Heat Pumps. IMPORTANT DOCUMENTS To Be Kept At All Times. With Equipment. Accredited Ecodan Installer:

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

BOILERMATE A CLASS SP

Daikin Altherma Hybrid User Guide

BOILERMATE A CLASS OV

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

heat interface units A BOILER WITHOUT A FLAME

GB24 & GB30. User Manual

Baxi Maxflow Combi WM

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Osprey 2 CFL

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Greenstar 12i/24i System

Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

USER GUIDE VOGUE MAX SYSTEM

GREENSTAR HIGHFLOW 440/550CDi

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

Kills bills. How Vaillant technologies reduce home heating bills

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Air to water Heat Pump System

USERS GUIDE 24, 30. For installation guide see reverse of book

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

GREENSTAR HIGHFLOW 440/550CDi

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Every Penny Counts. Cut your fuel bills how to save energy and switch supplier

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Operating instructions Oil condensing boiler

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

The world s most advanced direct electric water cylinder

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Greenstar 24i junior / 28i junior

Logic+ Combi

Energy Ambassadors Guide

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

User's Instructions. Alpha CB50

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

SmartRad Planning Manual

BOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers

Design, Installation & Servicing Instructions

The guarantee on this appliance is valid for 12 months from the first day of installation.

RF Programmable Room Thermostat User Instructions

ST9400A User Guide. Features

Modulating clock thermostat

Welcome to our Training Centre. Living Environmental Systems Division

Sweden s leading air source heat pump

System Installation. multi-zone heating

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

Greenstar 12i system / 24i system

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

User s Operation Instructions & Important Warranty Information

your comfort. our world. User Guide Small Monobloc For your new Daikin Altherma Small Monobloc heat pump

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

heating system Quantum at home The heater that adapts to its environment dimplex.co.uk/quantumathome

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Hot Water Heating Systems

USER GUIDE LOGIC HEAT H

THE HEAT PUMP CHOICE OF PROFESSIONALS

Daikin Altherma high temperature remote controller guide for schedule timers and operation functions

HEATING SYSTEMS. A guide to your central heating system and helpful energy saving advice.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Heating Control Danfoss Link & Connect Thermostats

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

ONE. User Manual. Electric Heating Element

VIESMANN. Operating instructions VITODENS 111-W. for the system user

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

CentaurPlus C27 Series 2 User Operating Instructions

GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

systemate 2000 fully integrated thermal store

ES3247B. 3 Channel Programmer. User and Installation Instructions

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Code of Practice. Efficient Use of Electricity

Your Daikin Altherma remote controller

Control Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L

Transcription:

HOMEOWNER KINGSPAN Homeowner s User Instructions MARCH 2012 Ecodan Aerocyl Plus-me: Air Source Heat Pump and Stainless Steel Cylinder Ecodan Air Source Heat Pump Model Number PUHZ-W50VHA(2)-BS PUHZ-W85VHA(2)-BS PUHZ-HW140VHA(2)-BS / YHA-BS PUHZ-HW140VHA-BS(2) / YHA(2)-BS

2

Homeowner s User Instructions Introduction The Ecodan air source heat pump extracts thermal energy from the outside air and transfers this into a property in the form of hot water as a conventional heating system does. The Ecodan will provide space heating (through radiators or under floor heating) and domestic hot water (taps, showers, etc). Domestic hot water always takes priority over space heating. The Ecodan Aerocyl Plus-me package is controlled by conventional heating system control equipment. A two channel time clock for ON and OFF periods, a cylinder thermostat for domestic hot water temperature and a room thermostat for space temperature. To optimise running costs it is advisable the homeowners seek the cheapest possible electricity tariff. An internet search facility like www.uswitch.com will be able to help. The homeowner will need to control the Ecodan Aerocyl Plus-me differently to a conventional gas boiler. The use of controls is paramount in achieving low running costs. Although electricity prices are higher than gas or oil, the efficiency of the system means that it requires less energy to supply the same heating demands, thus producing cheaper energy bills. Compared to regular electricity bills it will look higher than usual, but the homeowner should be aware that this bill incorporates heating that is usually achieved though gas or oil. Please note that heat pumps provide lower flow temperatures to radiators than a conventional gas boiler. Rather than the radiators turning on/off locally as with a gas boiler, heat pumps provide a more consistent lower flow temperature which allows for more efficiency and greater comfort. Warnings Don t allow anyone to interfere with the outdoor unit. Don t push any object through the grille area, there is a fast turning fan which could be damaged. Don t place objects too close to the outdoor unit. Don t ever cover the outdoor unit, air needs to circulate freely around the unit. Do be aware that ice may form in the winter period on the ground close to the outdoor unit. Please take particular care. Do ensure your installer includes anti-freeze (Alphi-11 or similar), 25% concentration into the heating circuit to prevent icing in the winter. Do complete your guarantee registration card and return to the manufacturer. If you do not complete and return the registration card the product will only be under guarantee for 12 months. Do take the installers contact details in case you need attention in the future. 3

Ecodan This will be located outdoors (most likely to be in the garden) facing away from the property. The air is sucked into the back and used to heat the refrigerant that is sealed within the unit. Cold air will be expelled from the front of the unit when the Ecodan is operating. The homeowner does not need to make any adjustments to this element of the system. Always ensure the front and back are clear of obstructions. Aerocyl Plus-me Stainless Steel Cylinder This will be located indoors in an airing cupboard. The controllers on this tank are used for installation purposes only and do not need to be adjusted by the homeowner. Wireless Receiver PAR-W21MAA Not necessary to adjust, the installation engineer uses this to commission the system Hot Water Control Thermostat Do not adjust Room Controllers Located within a room (placement on a wall will be dependent on installer). 2 channel time clock Used to control on/off periods for heating and hot water. Instructions on pages 9,10 and 11. Room Thermostat Used to control the room temperature. Instructions on pages 7 and 8. 4

The homeowner should know: How to switch on power to the Ecodan Aerocyl Plus-me This will be located inside the property near the mains power switch, it needs to be switched on. The outdoor unit does not needed to be touched. How to switch off power to the Ecodan Aerocyl Plus-me This will be located inside the property near the mains power switch, it needs to be switched off. If the homeowner is away from the property for several days only switch off the indoor switch. The outdoor unit does not need to be touched, do not switc h off at any time. How to set the radiator temperature Thermostatic radiator valves control the temperature of the radiator by a built-in sensor, which automatically opens and closes the flow of water into the radiator, maintaining the room at the pre-set temperature. A manual valve can only control the temperature of the radiator regardless of the room temperature. If you r property has thermostatic radiator valves, it is recommended that they are fully opened in occupied rooms. The Ecodan works by varying the flow temperatures to radiators depending on room thermostat and outside temperature. How to set indoor temperature The room thermostat is needed to set the indoor temperature. Refer to pages 7-8 for user instructions. How to set the timer The 2 channel time clock is needed to switch heating and hot water on/off. Refer to pages 9,10 and 11 for user instructions. How to switch to constant use Constant running dictated by the 2 channel time clock as this controls on/off periods. Refer to pages 7-8 for user instructions. Time clock pattern setup Each channel on the time clock should be programmed to meet the demands of the home occupier in the most efficient way. Hot water will take priority over heating. For example: If a homeowner wakes up in the morning and wants a shower at 7am and the property takes an hour to raise to the required room temperature then both channels should be set to 5am, as the vessel will take approximately one hour to achieve temperature before switching to space heating. Some electricity tariffs have cheaper off-peak tariffs (early hours of the morning) that can be used for heat-up times. Always check your electricity tariff by using www.uswitch.com. If the homeowner does not require hot water again until later in the evening then the time clock should be programmed to heat up approximately one hour prior. This is the most efficient pattern to use rather than maintaining a high storage temperature constantly. During cold periods the Ecodan will switch into a defrost mode occasionally. At this point the Ecodan will stop producing hot water for inside the dwelling. It will only be for a few minutes and will not cause radiators or under-floor heating to suddenly stop, nor will the heat of the cylinder radically drop. During this process steam may rise from the outdoor unit. This is a perfectly normal process, it is an automatic procedure. To maintain the efficiency of the Ecodan a weather compensation mode is activated (by the installer). When the outside temperature is colder the flow temperature to the radiators/under-floor is hotter. When warmer outside radiators will be less. This weather compensating curve is pre-set by the installing engineer. Lower flow temperatures mean higher efficiency. 5

Troubleshooting Fault Water does not heat up well Water or vapour is emitted from the Ecodan unit Cold water at hot taps Hot water provided but no heating Heating provided but no hot water Heating does not work at specific times Heating and hot water are active at different times during the weekend Room becomes too hot when heating is operated Possible Cause Ecodan may not be working to its highest capacity. Filter may be dirty and needs to be cleaned. During the heating mode, water may form and drop from the heat exchanger on the outdoor unit. During the defrosting mode, water on the heat exchanger or the outdoor unit evaporates and water vapour may be emitted. System may be switched off. Hot water used may have exceeded capacity of cylinder. Temperatures set are too low. Time clock has been programmed incorrectly. Time clock has been programmed incorrectly. Time clock has been programmed incorrectly. The programmable room thermostat has 5/2 split function to create different settings for the weekend. Programmable room thermostat set too high. Heating is not needed during summer months and should be switched off. Solution Make sure that there is plenty of space around the outdoor unit so air can flow in and out. Cleaning of this filter should be carried out by your installer. No solution necessary, this will not effect the performance of the Ecodan. No solution necessary, pay attention in icy conditions. Switch on unit and continue operation as usual. Tank will automatically fill up as water is used but will take time to heat up. This is dependent upon the size of the cylinder. Temperature parameters are too low and need to be set by your installer. Refer to pages 9, 10 and 11 for time clock instructions and set desired times for each function. Refer to pages 9, 10 and 11 for time clock instructions and set desired times for each function. Refer to pages 9, 10 and 11 for time clock instructions and set desired times. Refer to pages 7 and 8 for programmable room thermostat settings. Refer to pages 7 and 8 and lower temperatures. Refer to pages 9, 10 and 11 for time clock instructions to stop heating mode. If these options can not rectify the problems then please contact your local installer so a qualified engineer can fix the problem. Any work carried out by the homeowner will cause the warranty to be void. 6

Danfoss Thermostat User Instructions Your programmable room thermostat allows you to programme at different time periods. You can programme one set of times and temperatures for week days with a different set of temperatures for weekend days, this is referred to as 5/2 day operation. The thermostat can also be set up by your installer to provide one set of times and temperatures that are repeated each day of the week. This is referred to as 24 hour operation. The thermostat can also be set by you to provide two different programming blocks which can then be assigned to any day of the week, this is referred to as A/B programme operation. All thermostats can be set to provide up to 2,4 or 6 time and temperature settings each day. All thermostats feature useful overrides. 7

8

Danfoss 2 Channel Timeclock User Instructions The FP715 Si allows you to switch your heating and hot water on and off at times that suit you. Your programme has had the date and time set up during manufacture and will automatically change between Greenwich Mean Time and British Summer Time. You can programme up to 3 ON/OFF times per day for the heating and hot water and the two systems can be operated independently. 9

10

11

HOMEOWNER KINGSPAN Telephone: 01707 278666 After Sales Service: 0161 866 6089 email: heating@meuk.mee.com web: www.domesticheating.mitsubishielectric.co.uk UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881 IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531) Country of origin: United Kingdom Japan Thailand Malaysia. Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners. Printed in March 2012 SAP No. 250078 Designed by SquareBear 01604 899099. SquareBear are committed to using FSC certified paper and printers,wherever possible.