Peacock Salt. Multisol Pro VA Operation & Training Manual

Similar documents
CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Owners Manual for the Rainmaster Water Recycling System

What to expect from your water softener

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

Salt Spray Cabinet. Manual. Model Ref.: VF7705 (500 liter) VF7710 (1000 liter)

Water Softener Installation / Operation Manual

Brivis Service Manual

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

Warm Case Troubleshooting Guide 9/18/2014

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

The Professional s Choice

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

Emissions testing Honda Accord/Prelude

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

CRU-S Series Stainless Steel Condensate Recovery Unit

Owner's Manual. WS Series. Water Softener

SAFETY AND OPERATING MANUAL

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Rev B, 9/2/2009. Kodiak Chiller Overview

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Water Softener. Operating Manual

TPMS USER MANUAL. Table of Contents. Impaqed Products BV.

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

IJ3000 IJ3000 Flushing System N Revision B Installation Instructions Page 1 of 10

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

Operating, Installation and Service Manual W3400H, CLC 41 Clarus Control

BRAVO AUTOCLAVES. Installation Notes. BRAVO 1 Quick Start Guide SD-402 Rev. 1.0 Copyright 2012 SciCan Ltd. All rights reserved

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

VADA - Rain2Main Automatic Rainwater Controller

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Owners Manual For The Rainmaster Water Recycling System

CONTENTS. Page. Contents. Introduction, features and benefits. PART ONE Overview of the water softening process 4-5

A Steam-e product All Rights Reserved. GUM REMOVER Operating Instructions - June 2018

INSTRUCTION MANUAL FOR OIL BURNER MODELS

MV Hydro 5. MV Hydro 5-S Diesel Powered Water Heater Instruction Manual Ed MV Heating UK Ltd

CQUBE EVO OPERATION MANUAL EVO_OM_VKI_EN. Part No.: _06

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

NetworX Series NX-870E Fire Supervision Module Installation and Startup

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

INSTANTANEOUS ELECTRIC SHOWER

IMER USA (301) Koine 35 Quick User Guide IMER USA

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Which Refrigerant Analyzer do I have? Ultima ID Model RI-2004HV Series

Ceiling Mount Air Purification System

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

INSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

USING YOUR PRESSURE SEWER SYSTEM

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Water Softener VSOFT 15. Fitting and operating instructions. Changes of technical details are reserved. VSOFT / BWT UK Limited F R E E H O M E

DOMESTIC STEAM GENERATOR Installation Instructions

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Installation and Setup

Eco-Safe Digester. Installation Manual For E3 Series Digesters. Version 1.6 Published: Apr. 13, 2017

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

USER GUIDE VOGUE MAX SYSTEM

Glass and Dishwashers AMX / AUX Series

NOT EVERYTHING IN LIFE IS COMPLICATED.

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

O p e r a t i n g I n s t r u c t i o n s

IN ORDER TO PERFORM THESE TASKS, YOU WILL NEED THREE THINGS:

CPC-150-ANA. 150 litres, 535mm x 1300mm high. Pandora Heat Bank. 100kW Plate Heat Exchanger with 22mm Thermostatic Mixing Valve.

MV Hydro 9 Diesel Powered Water Heater Instruction Manual Ed. 2.00

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Artisan Thermostatic Bath Filler

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.:

WS1 Greensand Installation & Start Up Guide

INSTALLATION MANUAL TBA Evaporative Cooler

EST User Manual. (Please read this manual carefully before using)

Troubleshooting & faults guide

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

CBI-064. User Manual. Caddx to KNX-BUS Interface

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

BLAST-IT-ALL BUMPER BLASTER

Marco Beverage Systems Ltd.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

The Professional s Choice

Installation and Operating Manual

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

OPERATING & SERVICE INSTRUCTION MANUAL FOR

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

OWNER S MANUAL. EXQ / EZQ / EXS Evaporative Coolers. Original English Instructions. (English)

Guide To Troubleshooting INEFFICIENT COOLING FANS

Transcription:

Multisol Pro VA Operation & Training Manual Peacock Salt CONTENTS PAGE 1. Saturator Tank Diagram 2 2. Saturator Cabinet Diagram 3 3. Saturator Function 4 4. Inlet water 5. Adding Salt 6. Producing Brine 7. Pumping brine from the Saturator tank to the spreader 5 8. Pumping brine back from Spreader into Saturator tank. 9. Filling the Brine Storage Tank with Brine 6 10. Pumping brine from Brine Storage tank to Spreader 11. Pumping brine back from Spreader into Brine Storage tank 7 12. Maintenance Functions 13. LED Lights and CPU Displays 14. Error Messages 8 15. Troubleshooting Guide 9 Do not copy, cite, or distribute without permission from Peacock Salt Page 1 of 10

1. Saturator Tank Diagram example Do not copy, cite, or distribute without permission from Peacock Salt Page 2 of 10

2. Saturator Cabinet Diagram (for all models pre-2014) Do not copy, cite, or distribute without permission from Peacock Salt Page 3 of 10

SATURATOR PROCESSES 3. Saturator Function The Multisol Pro VA Saturator is designed to automatically mix salt and water to produce and store sodium chloride brine at a predetermined concentration. Salt is tipped into the hopper located at the top of the saturator. Brine is pumped into and percolates through the salt, and becomes concentrated brine. Diluting water is added to this brine to regulate its concentration. 4. Inlet water i. Water is fed under mains pressure into backflow prevention tank ii. Submersible pump is used to deliver water into system. iii. Pump function is controlled by two float valves a. Top valve controls maximum fill into backflow prevention tank b. Bottom valve identifies water supply issues if no water is supplied the system shuts down. iv. The water flows in one direction through check valves in the saturator cabinet v. The water supply is split into MAIN FEED and DILUTING FEED vi. The MAIN FEED water is sent to the base of the salt hopper where it mixes with the salt vii. The DILUTING FEED water is used to regulate the brine concentration 5. Adding Salt i. The lid must be fully opened to add salt using either the lid open / close switch, or the winch mechanism. a. Never operate the lid in high or gusting winds ii. Salt must be tipped in gradually into the salt hopper a. Do not tip any material other than rock salt into the hopper b. Take care not to scoop up accumulated debris along with the salt c. For every full spreader (3000 litres), approximately 1 tonne of salt must be added iii. Salt must be filled into the hopper until a cone of salt is visible at the top of the tank. This will ensure the saturator will function for as long as possible without requiring to be refilled again. iv. Close the lid 6. Producing Brine i. Switch the main control switch to setting 1 Brine Production / Fill to spreader ii. Water will be pumped into the saturator cabinet, through the Main Water and Diluting water flow meters. This is indicated by the floats in these meters raising up. a. 2013 onwards models may not have a diluting flow meter, but the function remains the same. iii. The diluting water flow rate is automatically adjusted, dependent on the brine concentration being produced. a. Lower specification saturators (pre 2009 installations) need manual adjustment of the diluting water flow rate. iv. The main water flow meter is manually adjusted to match the inlet water flow rate. This must never be adjusted unless instructed. a. If the mains water flow rate into the backflow prevention tank is lower than the flow rate through the main water flow meter, the backflow prevention tank will continuously empty. Do not copy, cite, or distribute without permission from Peacock Salt Page 4 of 10

b. The flow meter diaphragm valve must be adjusted to ensure the water being pumped from the backflow prevention tank is at a slower rate than the water inlet rate. v. Water flows into the salt hopper and mixes with it producing brine. vi. The brine flows from the salt hopper into the diluting chamber which is located in the top of the salt hopper vii. The concentration of the brine is analysed using the brine sensor. The concentration is displayed in the main CPU display panel. a. The brine concentration is only correct when brine is flowing through the brine sensor. b. If the system is sitting idle, the concentration of brine remaining in the brine sensor will be shown, which is not a true indication of the brine being produced / inside the tank. viii. Diluting water is added to the brine in the diluting chamber to reduce its concentration to within pre-determined parameters. This is done automatically, except on lower spec models (pre 2009). ix. An instant indication of whether brine is being produced is whether a steady flow of brine is visible in the hopper to tank linkage pipe and sample tube (clear PVC pipe with grey PVC fittings). x. Brine flows into the saturator storage tank at a known concentration. xi. Brine production will only stop being produced when: a. The saturator / storage tank is full. b. The saturator runs low on salt. If the salt empty light comes on, more salt needs to be added to the saturator and the main control switch needs to be turned to setting 2 then back to setting 1. c. An error arises. THE FOLLOWING ITEMS (7&8) ARE APPLICABLE ONLY TO STANDARD SATURATOR SYSTEMS, AND NOT ONES WITH STORAGE TANKS ATTACHED. 7. Pumping brine from the Saturator tank to the spreader If the tank minimum light is illuminated, this function will not work as there is not enough brine in the Brine Storage Tank The spreader shut-off cable must be docked, either in the saturator cabinet or the spreader, otherwise the pump will not function i. Connect Spreader to saturator using loading hose and electrical shut-off cable. ii. Open valves at end of loading hose and on spreader iii. Turn the pump delivery valves to the correct settings, as indicated inside the cabinet. Automatic valves will change automatically, specific to the switch setting selected. iv. Turn the control switch to setting1 fill spreader v. Press the green pump-on button on to start the pump. vi. Supervise the pumping process, never leave it unattended. vii. Brine delivery pump can be stopped as follows: a. Automatic pump stop this will happen when the float switch inside the spreader is activated, sending a signal to the saturator to stop the pump b. Manual pump stop press the Red pump-off button viii. Close valves at end of loading hose and on spreader ix. Disconnect spreader loading hose and electrical shut-off cable a. Dock shut-off cable in saturator docking port. Do not copy, cite, or distribute without permission from Peacock Salt Page 5 of 10

8. Pumping brine back from Spreader into Saturator tank. If the tank maximum light is illuminated, this function will not work as there is not enough capacity in the Brine Storage Tank i. Connect Spreader to saturator using loading hose. Electrical shut-off cable is not used and must remain docked in saturator docking port. ii. Open valves at end of loading hose and on spreader iii. Turn the pump delivery valves to the correct settings, as indicated inside the cabinet. Automatic valves will change automatically, specific to the switch setting selected. iv. Turn the control switch to setting2 empty spreader v. Press the green pump-on button on to start the pump. vi. Supervise the pumping process, never leave it unattended. vii. Brine delivery pump can only be stopped by pressing the red pump-off button, this must be done before the pump starts to draw air. viii. When pump is switched off, close valves at end of loading hose and on spreader ix. Disconnect spreader loading hose. THE FOLLOWING ITEMS (9-10) ARE APPLICABLE ONLY TO SATURATOR SYSTEMS WITH AN EXTERNAL BRINE STORAGE TANK 9. Filling the Brine Storage Tank with Brine i. When the saturator tank is full, the pump will switch on and deliver the contents to the brine storage tank. The saturator will continue producing brine. ii. The pump will stop when the saturator tank is emptied. iii. This process will continue until the brine storage tank is full. 10. Pumping brine from Brine Storage tank to Spreader If the tank minimum light is illuminated, this function will not work as there is not enough brine in the Brine Storage Tank The electrical shut off cable must always be docked, either in the saturator cabinet, or the spreader, otherwise the pump will not function i. Connect Spreader to Brine Storage tank using loading hose and electrical shut-off cable. ii. Open valves at end of loading hose and on spreader iii. Turn the pump delivery valves to the correct settings, as indicated inside the cabinet. Automatic valves will change automatically, specific to the switch setting selected. Do not copy, cite, or distribute without permission from Peacock Salt Page 6 of 10

iv. Turn the control switch to setting1 fill spreader v. Press the green pump-on button on to start the pump. vi. Supervise the pumping process, never leave it unattended. vii. Brine delivery pump can be stopped as follows: a. Automatic pump stop this will happen when the float switch inside the spreader is activated, sending a signal to the saturator to stop the pump b. Manual pump stop press the Red pump-off button c. Close valves at end of loading hose and on spreader i. Disconnect spreader loading hose and electrical shut-off cable ii. Dock shut-off cable in saturator docking port. 11. Pumping brine back from Spreader into Brine Storage tank If the tank max light is illuminated, this function will not work as there is not enough capacity in the Brine Storage Tank i. Connect Spreader to Brine Storage tank using loading hose. Electrical shut-off cable is not used and must be docked in saturator docking port. ii. Open valves at end of loading hose and on spreader iii. Turn the pump delivery valves to the correct settings, as indicated inside the cabinet. Automatic valves will change automatically, specific to the switch setting selected. iv. Turn the control switch to setting2 empty spreader v. Press the green pump-on button on to start the pump. vi. Supervise the pumping process, never leave it unattended. vii. Brine delivery pump can only be stopped by pressing the Red pump-off button, this must be done before the pump starts to draw air. viii. When pump is switched off, close valves at end of loading hose and on spreader ix. Disconnect spreader loading hose. 12. Maintenance Functions i. Stir tank contents a. Turn the pump delivery valves to the correct settings, as indicated inside the cabinet. b. Turn the control switch to setting3 stir tank contents c. Contents of tank will be agitated through the pump for a period of 30 minutes every 48 hours when this setting is selected. ii. Heating function a. In temperatures below 5.5degs, the trace heating cable and the back flow prevention tank heating automatically switches on. This serves to minimise the chance of water freezing. iii. Pump maintenance function Do not copy, cite, or distribute without permission from Peacock Salt Page 7 of 10

a. At the end of all production cycles, the pump will automatically switch on to flush brine through all pipework. This is to prevent these pipes from freezing. 13. LED Lights and CPU Displays i. Tank Min - Indicates that the saturator tank is empty. The pump will not function. ii. iii. iv. Tank Max Indicates that the saturator tank is full. Brine is delivered to brine storage tank until it is full. Brine Tank Full - Indicates that the brine storage tank is full. No more brine can be produced. Heating on Heating function is activated v. Pump on Pump is activated vi. vii. viii. ix. Temperature display indicates the cabinet air temperature Concentration % - indicates the brine concentration as a percentage Status Indicates the saturator status Error messages 14. Error Messages i. If an error arises a. Press reset button to remove alarm b. Press OK button on CPU to gain more information on error (where applicable) c. Resolve error or contact support ii. Reset Function a. The main control switch needs to be turned to setting2 then back to setting1. b. Allow pump to complete its maintenance cycle before changing settings. ERROR MESSAGE / LED ERROR TYPE REMEDY Salt empty LED The saturator has run low on salt Add more salt and reset the saturator Overflow LED There is a blockage between the salt hopper and the brine storage Remove the blockage and reset the system tank Heating Error displayed Indicates a fault with the heating systems Contact Support Vacuum Leak displayed Conc too Low displayed Conc too High displayed BFP Tank Empty or Water Tank Empty Indicates a fault with the double skin system Brine Concentration is produced too low Brine Concentration is produced too high issue with the diluting water supply Issue with water supply to saturator Contact Support Contact Support Contact Support Potential site water issues Identify whether there is a pipe freeze / damage issue in water pipes leading to the saturator. Contact Support if none identified. Do not copy, cite, or distribute without permission from Peacock Salt Page 8 of 10

Troubleshooting Guide Problem: Water does not flow into the saturator cabinet from the backflow prevention tank 1. Check the backflow prevention tank (a) Ensure the float switches within the backflow prevention tank are able to move freely. If they are tangled or trapped, free them to ensure complete functionality. (b) If there is no water in the tank and (a) has not remedied this, ensure the mains water supply is turned on. (c) Ensure the pump is operational (check it can be heard and water can be seen flowing through the flow meters inside the cabinet). If it cannot be heard, it is possible that the RCB has tripped and needs resetting. 2. If these remedies do not resolve the issue, please contact a Service Representative Problem: Saturator does not produce brine. 1. Check the Tank Full light. If this is illuminated, the tank is full to capacity and production will re-commence when brine is taken from the tank. 2. Check the Salt Empty light. If this is illuminated, there is too little salt within the hopper. Add more salt to the hopper and reset the system. 3. Check the Overflow light. If this is illuminated, the level of brine within the hopper is too high preventing the saturator from functioning. (a) If this occurs after filling the hopper with salt, the salt has been added too quickly causing a wave effect at the top of the hopper to trip the sensor. The sensor will reset when the level of brine in the hopper decreases. (b) If the fault persists, check the high level float at the top of the hopper for debris blockages. If any debris is present, it may prevent the float switch from returning to a down position. (c) If the fault is still not remedied, there is a more considerable blockage in the saturator system. Please contact a Peacock representative. 4. Check the Heating On light. If this is illuminated, the temperature is low enough for the mains water supply pipes to freeze. There may be a fault with the heating cable or supply pipes may have frozen leading up to the saturator. 5. Check the Water On light. If this is not illuminated, there is an electrical / connection fault prohibiting water to flow into the saturator. Please contact a Peacock representative. Problem: Brine production cuts off after short period of time. 1. Check the Salt Empty light. If this is illuminated, there is too little salt within the hopper. Add more salt to the hopper and reset the system. Do not copy, cite, or distribute without permission from Peacock Salt Page 9 of 10

2. If salt has been recently added to hopper, the brine may not have started to overflow. Continuously reset the system until you see brine flowing in the clear pipe exiting the top of the hopper into the saturator tank below. 3. Check the clear plastic tubes running into the Multisol Automatic Sensor (White box with red LEDs, inside the cabinet). If there is either no red lights showing, or no flow of brine through these pipes, there may be a blockage, preventing the brine concentration analysis. Please contact a Peacock representative. Problem: Pump functions but only draws air 1. Check the pump has been fully primed. No airlocks should be visible in the view glass on the top of the pump and when operational (a) If the pump has lost its prime, add water to the pump by opening the screw cap at the top of the pipe leading to the pump (outside the control cabinet), and fill this fully with fresh water. Tighten up the screwcap and switch the pump on to prime it. Problem: Pump does not function (b) If the pump still does not retain its prime, there is a blockage inside the base of the tank, preventing brine from being drawn. Ensuring the tank is less than half full, open the tank access hatch and assess the priming pipe directly inside the tank. This pipe can be removed and cleaned to enable the pump to be primed again. 1. Check the spreader docking cable (orange cable). If this is not docked either inside the saturator or in the back of the spreader, the pump will not function. 2. If the cable is docked in the back of the spreader and the pump still doesn t function, there may be a connection fault within the spreader. To bypass the automatic cut-off function, re-dock the cable in the saturator. Contact the spreader s manufacturer. 3. Check the Pump On light. If this is not illuminated, there could be an electrical / connection fault prohibiting the pump to operate. Please contact a Peacock representative. Problem: Brine does not flow correctly into or from spreader 1. Check the pump valve positions, ensuring they are correct for the required procedure (only applicable for manual saturators). 2. Check the valves at the loading hose / spreader, ensuring that these are both open. Problem: Alarm Sounding from saturator 1. If the alarm is coming from the Vacuum module (top right hand side of cabinet), the double skin wall to the saturator may have been damaged. Check the external wall for any visible leaks. Contact a Peacock representative as soon as possible. 2. If the siren and flashing light outside the cabinet are activated, a critical error has occurred. This error will be identified within the CPU in the main control cabinet. Resolve as per the instructions within this manual, and if the error persists, contact a Peacock representative at the earliest opportunity. Whilst every effort has been made to cover each possible eventuality within this troubleshooting guide, if other problems persist with the saturator, please contact a service representative. Do not copy, cite, or distribute without permission from Peacock Salt Page 10 of 10