Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

Similar documents
EXCELSIOR. High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS

Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

FSB Series II Gas-Fired Hot Water Induced Draft Boilers

STARFIRE IV WATER OIL FIRED CAST IRON BOILER

EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75

OIL-FIRED CAST IRON HOT WATER BOILER. Parts and Optional Accessories

GMOS Series OIL-FIRED CAST IRON STEAM BOILER PARTS AND OPTIONAL ACCESSORIES

15B Cast Iron Gas Fired Boilers For Forced Hot Water

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

WARNING. Keep area around vent terminal free of snow, ice, and debris.

SUPPLEMENTAL INSTRUCTIONS: DIRECT VENT INSTRUCTIONS FOR HIGH EFFICIENCY OIL-FIRED HOT WATER BOILER

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3

SUPPLEMENTAL INSTRUCTIONS: DIRECT VENT INSTRUCTIONS FOR HIGH EFFICIENCY OIL-FIRED HOT WATER BOILER

HOT WATER BOILER ( MBH)

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

WBV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

USER'S INFORMATION MANUAL

PUREFIRE PF-50, PF-80, PF-110 & PF-140 PF-50, PF-80, PF-110 & PF-140

WBV/WV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

Technical Bulletin MODELS AFFECTED SW3, SW3T SW4, SW4T SW5, SW5T

TriFire High Efficiency Oil Fired Hot Water Boiler

USER'S INFORMATION MANUAL

RAYPAK ILLUSTRATED PARTS LIST

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING

TriFire High Efficiency Oil Fired Hot Water Boiler

/13 Price - $5.00

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

USER'S INFORMATION MANUAL

DOMESTIC WATER HEATER OIL FIRED

WBV/WV. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

WV-DV. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

USER'S INFORMATION MANUAL

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

Direct Vent Supplement

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

PUREFIRE PF-50, PF-80, PF-110 & PF-140 PF-50, PF-80, PF-110 & PF-140

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

WGO Series 3 Section Assembly

SERIES 19A. mith PRESSURIZED WET BASE

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Service Instructions for use by heating contractor VITOROND 200 IMPORTANT. Read and save these instructions for future reference.

Columbia Boiler Company

LRF Lowboy Rear Flue Model LRFV

Keeping Families Comfortable For More Than 60 Years

EC/ECT. Series. Oil. Boilers. Installation, Operation & Maintenance Manual

OIL-FIRED CENTRAL FURNACE

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR 3-PASS OIL BOILER

CATALOG OF REPLACEMENT PARTS

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

Parts Lists with Exploded Views

SCS SCS

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS FOR V7 SERIES OIL FIRED BOILER KNOCKDOWN & PACKAGED HEATING UNITS

DFG-100-ES and DFG-200-ES

BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA

oil furnaces BCL, BFL, BML, BMLV 60, ,000 BTU HML, HMLV, HTL, HTLV 60, ,000 BTU Multiposition WML, WMLV, MPL 60, ,000 BTU

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

Section 12 - REPLACEMENT PARTS Use only genuine LAARS replacement parts.

Pump or Manifold Pressure. Nozzle or Gas Orifice Size. Air Setting

Single stage operation oil burner

Replacement Parts List

MASTERTEMP HEATER REPLACEMENT PARTS

Direct Vent. Oil Fired Warm Air Furnaces INSTALLATION, OPERATION & MAINTENANCE MANUAL WARNING

USER'S INFORMATION MANUAL

Forced draught natural gas/propane burner

Odyssey Model Numbers: CT Version Date:

Installation, Operation and Service Manual

Rheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor

BCX-14 & BX-14 COMBINATION OVEN STEAMER CNVX-14 CONVECTION OVEN REPLACEMENT PARTS LIST

CSD-1 COMMERCIAL BOILER CONTROLS

STARFIRE V STEAM Series 5 OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL. Models

Single stage operation oil burner

Keeping Families Comfortable For More Than 60 Years

Keeping Families Comfortable For More Than 60 Years

Replacement parts EG/PEG

Effective february 9, 2015

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

RAYPAK ILLUSTRATED PARTS LIST

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

B10 SERIES BOILER B3-B9

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Installation, Operation and Service Manual

Home Stack Washer/Dryers

SERVICE TECHNICIAN ONLY read and follow completely.

Price - $ /12

Installation, Operation and Service Manual

OWNERS MANUAL MODEL CC500

Installation, Operation and Service Manual

Transcription:

TRIFIRE SERIES II High Efficiency Oil Fired Hot Water Boiler Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190 REPAIR PARTS & OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number from data plate on your boiler. Include following information when ordering. Part Number Part Description Boiler Model Number Boiler Serial Number Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com PN 240011581 REV. C [08/1/2018]

JACKET 8 1 2 10 9 3 4 7 6 5 KEY DESCRIPTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION Complete Jacket Assembly 550002392 550002393 550002394 550002395 1 Top Panel 109008594AC 109008595AC 109008596AC 109008597AC 2 Rear Panel, Upper 109008607 3 Rear Panel, Lower 109008624 4 Right Side Panel 109008660AD 109008661AD 109008662AD 109008663AD 5 Support Bracket, Lower Rear 109008628 6 Support Bracket, Lower Front 109008625 7 Front Panel 109008606AC 8 Left Side Panel 109008664AD 109008665AD 109008666AD 109008667AD 9 Support Bracket, Upper Front 109008608 10 Support Bracket, Upper Rear 109008626 2 PN 240011581 Rev. C [08/1/2018]

HEAT EXCHANGER 1 2 7 8 3 16 13 15 14 11 12 10 9 6 4 5 Item Description 4 Section 5 Section 6 Section 7 Section 8a 8b Chimney Vent Heat Exchanger Block (Includes Items 1,2,4,5,6,11,12,13,14,15,16) Direct Vent Heat Exchanger Block (Includes Items 1,2,4,6,11,12,13,14,15,16) 550003106 550003107 550003108 550003109 550003110 550003111 550003112 N/A 1 Control Well in Block 240007709 2 1¼ x ¼ Bushing (for Temperature Pressure Gauge) 240009346 4 1¼ x ¾ Bushing (for Drain Valve) 1060003 5 5" Flue Collar (Used on 4/5/6 Section Chimney Vent Blocks Only) 109007382 109007382 109007382 N/A 6 Sight Glass Replacement Kit 550001932 11 Target Wall Insulation* 240007302 12 Door Hinge Kit (2 hinges included) 550001933 13 Door insulation (hard)* (Front Door) 240007300 14 Door Insulation (soft)* (Inner Burner Door) 240007301 15 Door Rope Gasket* 240007390 16 Burner door with insulation & rope gasket 240007305 Items below Ordered Separately 3 ¼ NPT Plug 240005463 7 Top Baffle (2 Required) 109007385 109007386 109007387 N/A 9 V-Shaped Liner N/A 109008787** 109007316 109007315 10 Oval Liner 109007317 N/A N/A N/A Heat Exchanger Insulation Center* 420001080 420001081 420001082 420001083 Heat Exchanger Insulation Rear* 420001079 Not shown * WARNING: This product contains fiberglass and/or ceramic fibers. Possible cancer hazard. To avoid this possible hazard, avoid breathing fiberglass wool & ceramic fiber dust. May cause irritation to skin, eyes & respiratory tract. ** Used on 5115 and 5135 models only with Beckett NX burner only. 3

STANDARD CONTROLS & ACCESSORIES 1a 9 1b 8 10 7 1c 6 5 4 3 2 Key Description Part Number 1a Limit Control 240009347 1 Limit Control Assembly 3002009 1b Limit Sensor Wire 48 240007708 Incudes 1a thru 1d 1c Wire Harness, Control 240009174 *1d Wire Harness, Circulator 37519501 2 24 Flexible Oil Line 240007147 3 Burner Attachment Bolts - 5/16-18 X ¾ LG (Qty 4) 240007237 4 ¾ Street Elbow 14693040 5 Limit Control Mounting Plug 240007734 6 ¾" Drain Valve 240009323 7 1 ¼ x 10 Adapter 14607012 8 1 ¼ x 6" Adapter 14607017 9 Barometric Draft Control, 5 (4 thru 6 section) 240007166 Barometric Draft Control, 6 (7 Section only) 14620007 10 Temperature / Pressure Gauge 240009345 * Control Well Grommet for Sensor Wire 240007713 * 1¼" x 1¼" x ¾" Tee PF05901 * 1¼" x ¾" x 1¼" Tee 1510001 * ¾" Safety Relief Valve (30 PSI) VR-001.01 * = not shown 4

OIL BURNERS Replacement Burners Description 4075 4095 4110 5100 5115 5135 Oil Burner - Beckett Chimney Vent w/o Cover Model AFG except 5115 and 5135 use Model NX Oil Burner - Beckett Chimney Vent with Cover Model AFG except 5115 and 5135 use Model NX 240007232 240009385 240009386 240007233 240009387 240009388 240007144 240009377 240009378 240007145 240009379 240009380 Oil Burner - Becket Direct Vent Model NX 240007531 240009393 N/A 240007532 240009395 240009396 Oil Burner - Riello Chimney Vent Model 40F 550003548 550003549 550003550 550003551 550003552 550003553 Oil Burner - Riello Direct Vent Model 40BF 550003560 550003561 550003562 550003563 550003564 550003565 Oil Burner - Carlin Chimney Vent Model EZ-LF 240010357 REPLACEMENT BURNERS - CONTINUED Description 6130 6145 6165 7165 7180 7190 Oil Burner - Beckett Chimney Vent w/o Cover Model AFG except 5115 and 5135 use Model NX Oil Burner - Beckett Chimney Vent with Cover Model AFG except 5115 and 5135 use Model NX 240007234 240009389 NA 240007235 NA NA 240007146 240009381 NA 240007183 NA NA Oil Burner - Becket Direct Vent Model NX 240007533 NA NA NA NA NA Oil Burner - Riello Chimney Vent Model 40F 550003554 550003555 550003556 550003557 550003558 550003559 Oil Burner - Riello Direct Vent Model 40BF 550003566 NA NA NA NA NA Oil Burner - Carlin Chimney Vent NA NA NA NA NA NA 5

OIL BURNERS BECKETT BURNER REPLACEMENT PARTS - AFG & NX CAD Cell (AFG & NX) CD-001.01 Power Cord (AFG & NX) 240007129 Oil Pump Solenoid RP04601 Pump, Oil Clean Cut #2184404U 29688 Burner Motor 21805U 1050008 Beckett Burner Cover Kit 240007393 See Burner Manual for illustrations. When ordering, use the above part numbers. BECKETT BURNER REPLACEMENT PARTS - AFG ONLY Combustion Air Tube With Custom Flange, AFG70MQASN w/l2 Head 240007638 Combustion Air Tube With Custom Flange, AFG70MKAQN w/v1 Head 240007639 Igniter & Base Plate (Replacement Burner) 1050007 Drawer Assembly, (incl. 3-3/8U Static Plate & L2 head Igniter) 240007640 Drawer Assembly, (incl. 2-3/4M Static plate, V1 head Igniter) 240007641 Burner Control, 7505P1515 Beckett Genisys (Pre 15s Post 15s) 240008818 Burner Gasket with keyhole 240007392 L2 Head 240007645 V1 Head 240006446 3-3/8U Static Plate BN08102 2-3/4M Static Plate 240007646 BECKETT BURNER REPLACEMENT PARTS - NX ONLY Combustion air tube with custom flange, NX70LC 240007772 Combustion air tube with custom flange, NX70LD 240007773 Igniter & Base Plate 240007774 Drawer Assembly (incl. Static Plate, Press Sensor Tube, Igniter, 6 Slot NX Head) 240007775 Drawer Assembly (incl. Static Plate, Press Sensor Tube, Igniter, 9 Slot NX Head) 240007776 Burner Control 7505P152M Beckett Genisys (Pre 15s Post 2m) 240007777 Burner Gasket with Keyhole 240007778 Head/Leg Assembly, 6-slot NX1 240007779 Head/Leg Assembly, 9-slot NX2 240007780 Air Inlet Adapter, Modified 240007781 Pressure Switch 2198501 (0.65" wc) 240007782 Pressure Switch 21985 (0.85" wc) 240007783 Head Adjustment Mechanism 240007784 6

REPLACEMENT PARTS CIRCULATORS Circulator - Grundfos UP15 Circulator - Taco CI-006.01 CI-001.03 KITS Description Part Number Manual Reset Temperature Limit Kit 550001929 Manual Reset High Limit Control 1010003 Manual Reset Wire Harness 240007127 Immersion Well 14662804 5 Vent Safety Kit (Required in Canada, USA optional) 550003423 5 Flue Connector 30655 Wire Harness 240011785 Assembly, WMO Control Field 30660 6 Vent Safety Kit (Required in Canada, USA optional) 550003422 6 Flue Connector 30656 Wire Harness 240011785 Assembly, WMO Control Field 30660 FOR DIRECT VENT UNITS ONLY Kit, Vent Flex, 4 dia x 10 with Terminal adapter 550003419 Kit, Vent Flex, 4 dia x 15 with Terminal adapter 550003420 Kit, Vent Flex, 4 dia x 20 with Terminal adapter 550003421 Terminal Adapter (part of Vent Flex kit) 240006914 Appliance Adapter 3 Pass Oil Boiler (part of Vent Flex Kit) 240007535 Vent Terminal Oil 28972 Riser Terminal (adds 36 height) 29231 7

2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com All specifications subject to change without notice. 2018 ECR International, Inc. BDR THERMEA GROUP