Design Criteria. Installation

Similar documents
Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

The Series LFII (TY3596) Residential

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Model/Sprinkler Identification Numbers

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

Sprinkler Identification Numbers

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

Technical Data. Installation

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Model/Sprinkler Identification Number (SIN) Technical Data

Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Numbers

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Submittal Packages Detailed with Items and Reviewers

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Page 1 of 8 AUGUST 2011 TFP400. Technical Services

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Models BB, SD, HIP, and AP Specific Application Sprinklers for Protecting Attics General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Full-scale tested, for use in wood truss construction. Listed for specific roof slopes from 4:12 to 12:12.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

CD6102 / CD6102 OC / CD6102-2

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Sprinkler Identification Numbers

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

MaxLite LED MICRO-T PANEL

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Sprinkler Identification Number (SIN)

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Duct Mount. Installation Instructions

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Transcription:

Model G5 Sprinkler Guards for Use with Series DS-1 Sprinklers Standard, Deep, and No Escutcheons General Description The TYCO Model G5 Sprinkler Guards are designed for use with Series DS-1 Sprinklers located in areas that make the sprinklers susceptible to mechanical or physical damage. The Model G5 Sprinkler Guard can be installed only on sprinklers with standard and deep escutcheons, as well as sprinklers without escutcheons. This Sprinkler Guard cannot be installed in recessed applications. The Model G5 Sprinkler Guards described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals UL Listed Physical Characteristics Welded assembly fabricated from carbon steel Finishes Zinc Chromate Design Criteria In accordance with the requirements of the NFPA, sprinkler guards shall be listed. Guards are only listed for use with the Series DS-1 Sprinklers. Installation The TYCO Model G5 Sprinkler Guard must be installed in accordance with the following instructions. These instructions require, at the minimum, a 9/64 Allen Wrench. 1. Install sprinklers with applicable escutcheon in accordance with the Model DS-1 Sprinkler data sheets (TFP500, TFP510, or TFP560), as well as Table A on Page 4. 2. With Bulb Protector removed, carefully pass the Guard over the Deflector without damaging the Sprinkler. The Sprinkler Guard is designed to fit over the Deflector without removing the screws. However, if required to allow adequate passage over the Deflector, loosen the Screws and separate the Base Plates. Open the Guard slightly. Refer to Figure 2A. 3. Align the center-line of the Guard with the center-line of the Sprinkler while directing the Base Plates toward the sprinkler. Refer to Figure 2B. 4. Align the Grips with the Wrench Flats and guide into position. Proper position is achieved when the Base Plates are seated against the Frame Base. Refer to Figure 2B. 5. While holding the Guard in position firmly against the Frame Base, alternately tighten the Screws with a 9/64 Allen Wrench until evenly snug and the Grips uniformly engage the Wrench Flats. Refer to Figure 2C. 6. Apply the final torque of 5 to 6 ft.- lbs. evenly to both Screws Refer to Figure 2C. 7. Inspect installation of the Guard to verify the following. Refer to Figure 2D. The Guard center-line is in-line with the Sprinkler center-line. The Base Plates are fully seated against the Frame Base. The Grips are evenly engaged with the Sprinkler Wrench Flats. The Screws are equally engaged across the Base Plates. The Base Plates must seat against the Frame Base to be fully seated and to complete the installation. The Model G5 Sprinkler Guard may be located in any position relative to the sprinkler frame arms. Page 1 of 6 FEBRUARY 2011

Page 2 of 6 INSTALL (WITH ESCUTCHEON AS APPLICABLE) SEPARATE BASE PLATES FOR ADEQUATE INSTALLATION CLEARANCE. LOOSEN OR REMOVE SCREWS AS NEEDED. FIGURE 2A INSTALLATION STEP 1 GUIDE BASE PLATES OVER. SLIGHTLY ALTER ALIGNMENT AS NECESSARY TO CLEAR DEFLECTOR. DO NOT DAMAGE BULB. FRAME BASE WRENCH FLAT ORIENT GUARD WITH S ALIGNED TO WRENCH FLATS AS SHOWN. BASE PLATES RELIEF GUARD AND PARTIALLY CUT AWAY TO SHOW DETAIL FIGURE 2B INSTALLATION STEP 2

Page 3 of 6 PROPERLY POSITION GUARD, HOLD IN PLACE, AND ALTERNATELY TIGHTEN SCREWS WITH 9/64" ALLEN WRENCH UNTIL EVENLY SNUG. APPLY FINAL 5-6 ft. lbs. TORQUE TO EACH SCREW. FIGURE 2C INSTALLATION STEP 3 INSPECT GUARD FOR PROPER INSTALLATION. FULLY SEAT BASE PLATES AGAINST FRAME BASE. EVENLY ENGAGE WRENCH FLATS BY BASE PLATE S. PROPER ENGAGEMENT OF BASE PLATES ON WRENCH FLATS AND FRAME BASE WRENCH FLAT RELIEF BASE PLATE FIGURE 2D INSTALLATION STEP 4

Page 4 of 6 Sprinkler Series TFP SIN Sprinkler Type* Sprinkler Nominal K-Factor Mounting Location Approvals Model G5 Guard DS-1 TY3255 Pendent 5.6 Wrench Area (1) DS-1 TY3235 Pendent 5.6 Wrench Area (1) DS-1 TY3355 HSW 5.6 Wrench Area (1) DS-1 TY3335 HSW 5.6 Wrench Area (1) DS-1 Stainless Steel TY3230 Pendent 5.6 Wrench Area (1) DS-1 Stainless Steel TY3250 Pendent 5.6 Wrench Area (1) DS-1 Stainless Steel TY3337 HSW 5.6 Wrench Area (1) DS-1 Stainless Steel TY3357 HSW 5.6 Wrench Area (1) *The Model G5 Guard can be installed only on sprinklers with standard and deep escutcheons, as well as sprinklers without escutcheons. This Sprinkler Guard cannot be installed in recessed applications. 1. Listed by Underwriters Laboratories TABLE A APPLICATION GUIDE * REFER TO SERIES DS-1 DATA SHEETS FOR DESIGN CRITERIA AND INSTALLATION DIMENSIONS. VARIES PER ESCUTCHEON OPTION * 1-1/2" (38,1 mm) 3" (76,2 mm) 3-11/16" (93,7 mm) SERIES DS-1 DRY-TYPE PENDENT MODEL G5 GUARD VARIES PER ESCUTCHEON OPTION* 2" (50,8 mm) SERIES DS-1 DRY-TYPE HSW MODEL G5 GUARD 2-3/4" (69,9 mm) 2-3/4" (69,9 mm) 3" (76,2 mm) FIGURE 1 DIMENSIONS 3-11/16" (93,7 mm)

Page 5 of 6 Care and Maintenance The TYCO Model G5 Sprinkler Guard does not require any regularly scheduled maintenance, However, proper installation of the Sprinkler Guard should be verified during the annual visual inspection of the sprinklers. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Responsibility lies with sprinkler owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Owners must ensure that sprinklers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather-duster. Otherwise, inadvertent sprinkler operation may result. Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for products or components manufactured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP s sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer s representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Model G5 Sprinkler Guard Specify Model G5 Sprinkler Guard with a Zinc Chromate finish and P/N 56-938-9-000.