Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Similar documents
Lo-Carbon Quadra Centrifugal Fan

Silhouette Installation and Wiring Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra SELV

Lo-Carbon Quadra Centrifugal Fan

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Centrif Duo & Centrif Duo Plus

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

HR200WK Through the wall Heat Recovery Ventilator

Lo-Carbon SELV Tempra

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Lo-Carbon T-series Window & Roof Models

Lo-Carbon PoziDry Pro

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

SUPER T WALL FANS. Installation and Wiring Instructions

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Installation and Wiring Instructions

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

Sentinel. Kinetic Advance MVHR. Installation & Commissioning. Stock Ref. N Advance S Advance SX

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Sentinel Kinetic MVHR RANGE

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Installation & Operating Instructions

100 FLUEBOOST

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

FLUEBOOST. flueboost 350 gas fire model

KUDOS. Instruction leaflet

G Installation manual Solitude - dmev unit

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Installation manual Mori HR

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Installation & Operating Instructions

Purge Ventilation Unit. Product Manual. ventilation systems TP625

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

Warnings, Safety Information and Guidance

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

WHHR Midi & Midi Lite

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

MODEL: BV400 Part No:

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit

Xpelair Simply Silent TM Contour Fan

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Lucci Designer Hi Flow Exhaust Fan

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Thank you for choosing EnviroVent

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

HOTLINE:

CI/SfB (57.7) 2nd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

aura-t TP536/GBR ventilation systems

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

Xpelair Simply Silent TM DX100 Fan

Centrifugal extract and condensation control fans

Xpelair Simply Silent DX150

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Turbo Inline Fan, White - Non Illuminated Art no.33500

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

Thank you for choosing EnviroVent

White - Non Illuminated Art no White - Cool White LED Art no.32600

Stainless Steel Chimney Extractor

November This product has been reconfigured Please read these instructions

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide

CI/SfB (57.7) 1st edition

Sentinel. Kinetic MVHR Range. Installation & Commissioning. Stock Ref. N PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Transcription:

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Installation and Wiring Instructions Stock Ref. N 427485B (P) 427486B (T) 427487B (HT) 427488B (TM) FAN UNITS 12V DC SELV (CLASS III) CONTROLLERS 220-240V 50Hz MAINS SUPPLY (CLASS II) WITH 12V DC SELV OUTPUT PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS T IPX7 (FAN)

Installation and Wiring Instructions for the Lo-Carbon SOLO Plus SELV Bathroom Extract Fan. IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION DO NOT install this product in areas where the following may be present or occur: Excessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapours. Ambient temperatures higher than 40 C or less than 5 C. Possible obstructions which would hinder the access or removal of the Fan. SAFETY AND GUIDANCE NOTES A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and MUST be installed by a suitably qualified person. B. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact separation of at least 3mm. C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. It is recommended that the connection to the fan connector terminals is made with flexible cable. F. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuelburning appliance. G. The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time. H. Where ducted Fans are used to handle moistureladen air, a condensation trap should be fitted. Horizontal ducts should be arranged to slope slightly downwards away from the Fan. I. This appliance is not intended for use by persons (Including children) with reduced physical, sensory or 2

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. J. Young children should be supervised to ensure that they do not play with the appliance. K. Fans used for tropical climates. IMPORTANT:- ONLY CONNECT TOGETHER PRODUCTS FROM THE LO-CARBON SOLO PLUS SELV RANGE SINCE THE FANS ARE SPECIALLY DESIGNED TO WORK ON 12V DC AND ARE NOT COMPATIBLE WITH OTHER VENT-AXIA CONTROLLERS. DO NOT CONNECT MORE THAN ONE FAN TO THE CONTROLLER. DESCRIPTION As standard, the Lo-carbon SOLO Plus SELV is suitable for panel/wall installations, flush or surface mounting, either in a horizontal or vertical plane. 100mm ducting (flexible or straight) can be attached using the supplied adjustable spigot, providing rear or side exit options. Adaptors for System 25 and System 50 ducting can be used in conjunction with the adjustable spigot. For wall installations a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used. An optional filter is also available (449265). Please see our catalogue or web site (www.vent-axia.com) for more information on System 25/50 and for alternative ducting and termination options. SITING THE CONTROLLER 1. The controller must not be installed in a shower cubicle or enclosure. It must be sited away from direct sources of water spray and out of reach (1.5m) of a person using a fixed bath or shower. 2. Site away from direct sources of heat. Ambient temperature range 0 to 40ºC. Do not site in an area containing excessive levels of grease. 3. Decide where to site the controller and fan (see section siting the fan), and work out the required cable runs. SITING THE FAN 1. The electrical supply to this fan is 12V DC SELV from the mains controller. This means that the fan may be installed within reach of a person using a fixed bath or shower, i.e. in a nearby wall. However, the fan must not be placed where it could be submerged in water or regularly exposed to direct water spray, e.g. from a shower head whether permanently fixed or movable. A. INSTALLATION PANEL MOUNTING (Surface) 1. Cut a 105mm hole through the panel, ensuring that there is sufficient space for the product to be installed and that the filter (If fitted) can be removed for maintenance. 2. Removing the grille. Firstly remove the front cover by carefully pulling each corner of the front panel until it is free to be removed from the inner grille (Fig 1). Unscrew the two screws at the bottom of the inner grille. The screws will remain in the inner grille but will be loose when the grille is ready to be removed (Fig 1). Lift the inner grille from the bottom edge ensuring not to damage the sensor cable (TM model only) attached to the front assembly and Base Housing (Fig 6). 3. Remove the Spigot Ring from inside the carton and clip over the Spigot Adaptor making sure the lip on the Spigot Ring locates firmly inside the groove on the Spigot Adaptor (Fig 2). Ensure that the Spigot Adaptor is firmly located onto the Base Housing and the shutter is still securely fastened and fully functional. 4. Set-up the appropriate speed selection and other features as outlined in Section B SETUP. 5. Attach the ducting to the Spigot and locate into the hole in the panel ensuring the Skirt is located correctly into the Base Housing. Secure into position using appropriate fixtures (Fig 3) 6. Ensure the Impeller rotates freely. 7. Select and follow the appropriate wiring diagram in Section C WIRING. 8. Replace the inner grille ensuring that the PIR sensor cable (TM model only) is reconnected to the PIR sensor PCB (Fig 6) Replace the front panel. 9. Switch the mains power supply on and check the fan is operating correctly. PANEL MOUNTING (Flush) 1. Mark and cut a rectangular hole (190mm x 240mm) through the panel, ensuring that there is sufficient space for the product to be installed and that the filter (If fitted) can be removed for maintenance. IMPORTANT: Be careful to avoid joists and hidden cables. 3

2. Removing the grille. Firstly remove the front cover by carefully pulling each corner of the front panel until it is free to be removed from the inner grille (Fig 1). Unscrew the two screws at the bottom of the inner grille. The screws will remain in the inner grille but will be loose when the grille is ready to be removed (Fig 1). Lift the inner grille from the bottom edge ensuring not to damage the sensor cable (TM model only) attached to the front assembly and Base Housing (Fig 6). 3. Remove the Spigot Ring from inside the carton and clip over the Spigot Adaptor, making sure the lip on the Spigot Ring locates firmly inside the groove on the Spigot Adaptor (Fig 2). The Spigot can be repositioned for side exit installations by removing the screw and sliding the spigot away from the rear of the Base Housing, carefully observing the guide rails (Fig 4). The Spigot can then be rotated and repositioned for side exit using the same guide rails and retaining screw (Fig 4). Ensure that the Spigot Adaptor is firmly located onto the Base Housing in the required orientation and the shutter is still securely fastened and fully functional. 4. Remove the Skirt and pass the supplied screw fully through the flange of the base housing. Then attach the 3 supplied Panel Clips (Fig 5) and partially screw into place until they are properly retained (allowing enough gap for the panel thickness). 5. Set-up the appropriate speed selection and other features as outlined in Section B SETUP. 6. Attach the ducting to the Spigot and locate into the hole in the panel, ensuring the cable is fed into the Base Housing and the Panel Clips spring out behind the panel. 7. Secure into position by carefully tightening the Panel Clips. It maybe necessary to hold the product centrally in the hole while tightening so that no gaps are seen once the cover is on. IMPORTANT: If power tools are used, set them to the minimum torque setting or preferably use a manual screwdriver. Do not over tighten. 8. Ensure the Impeller rotates freely. 9. Select and follow the appropriate wiring diagram in Section C WIRING. 10. Replace the inner grille ensuring that the PIR sensor cable (TM model only) is reconnected to the PIR sensor PCB (Fig 6). Replace the front panel. 11. Switch the mains power supply on and check the fan is operating correctly. WALL MOUNTING (Surface) For wall installations a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used. 1. Cut a 115mm. hole through the wall, ensuring that there is sufficient space for the product to be installed and that the filter (If fitted) can be removed for maintenance. 2. Insert the wall sleeve with the smaller diameter sleeve on the room-side and cement both ends into position flush with the wall faces. The wall sleeve should be angled downwards, away from the fan, to allow any condensation to drain to the outside wall. 3. Outside Grille: Using the Back Plate as a template, mark the fixing hole centres on the wall. Drill and plug the wall and fix the Back Plate into position. 4. Fix the Outside Grille on to the Back Plate (screws provided). Ensure the louvres are pointing downwards. 5. Removing the grille. Firstly remove the front cover by carefully pulling each corner of the front panel until it is free to be removed from the inner grille (Fig 1). Unscrew the two screws at the bottom of the inner grille. The screws will remain in the inner grille but will be loose when the grille is ready to be removed (Fig 1). Lift the inner grille from the bottom edge ensuring not to damage the sensor cable (TM model only) attached to the front assembly and Base Housing (Fig 6). 6. Remove the Spigot Ring from inside the carton and clip over the Spigot Adaptor making sure the lip on the Spigot Ring locates firmly inside the groove on the Spigot Adaptor (Fig 2). Ensure that the Spigot Adaptor is firmly located onto the Base Housing and the shutter is still securely fastened and fully functional. 7. Set-up the appropriate speed selection and other features as outlined in Section B SETUP. 8. Using the Base Housing as a template, mark the fixing hole centres on the wall, carefully sliding the spigot into the Wall Liner. Secure the Base Housing into position using the screws and fixings provided ensuring the Skirt is located correctly into the Base Housing (Fig 3). 9. Ensure the Impeller rotates freely. 10. Select and follow the appropriate wiring diagram in Section C WIRING. 12. Replace the inner grille ensuring that the PIR sensor cable (TM model only) is reconnected to the PIR sensor PCB (Fig 6). Replace the front panel. 13. Switch the mains power supply on and check the fan is operating correctly. B. SETUP WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. IMPORTANT On first power up, the fan will run through its initialization routine. On T, HT & TM models the fan will switch on and off during this routine (Including the LED) Once complete after approximately 2 minutes, the fan will run as normal. 4

1. SELECTING THE CONSTANT TRICKLE OPTION - Switch dip switch 2 into the ON position to activate the constant trickle operation. To disable the constant trickle option, move dip switch 2 into the OFF position. (Fig 7). 2. SELECTING THE TRICKLE SPEED (if enabled) This will determine the speed at which the fan will run continuously if the constant trickle speed option is enabled (1 above). Low trickle speed Switch dip switch 1 into the OFF position (Fig 7). High trickle speed Switch dip switch 1 into the ON position (Fig 7). 3. SELECTING THE INSTALLATION RUNNING MODE This will determine the speed at which the fan will run when activated by either the Pull-cord/LS line/humidity/pir. Wall mode Switch dip switch 3 into the OFF position (Fig 7). Ducted mode Switch dip switch 3 into the ON position (Fig 7). 4. SELECTING THE DELAY-ON OPTION (T and HT models) - Switch dip switch 4 into the ON position to activate the delay-on feature. This will prevent the fan from going to boost for approximately 2 minutes. If the Switch Live is disconnected (switched off) within this period the fan will not boost. If the Switch Live is still active after the period the fan will boost (Fig 7). 5. TIMER ADJUSTMENT (T, HT, TM models) The overrun time period is factory set to 15 minutes. The overrun time period may be adjusted from 5-30 minutes by altering the adjuster on the control PCB [T] (Fig 7). i. To REDUCE the operating time, turn the adjuster [T] ANTI-CLOCKWISE (Fig 7). ii. To INCREASE the operating time, turn the adjuster [T] CLOCKWISE (Fig 7). 6. HUMIDITY ADJUSTMENT (HT model) The fan s Humidity Set-Point is factory set to switch the fan on at 72%RH (Fig 7). i. To LOWER the Set-Point, turn the Humidity Adjuster [H] ANTI-CLOCKWISE. This makes the fan more sensitive to RH%, i.e. the fan will come on at a lower RH% (Fig 7). ii. To RAISE the Set-Point, turn the Humidity Adjuster [H] CLOCKWISE. This makes the fan less sensitive to RH%, i.e. the fan will come on at a higher RH% (Fig 7). C. WIRING. IMPORTANT WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. The Controller MUST be surface mounted to allow air to freely circulate around the unit. When installed in a loft void it MUST NOT be enclosed or covered with insulation. 1. Select and follow the appropriate wiring diagram (Fig 8-9) 2. It may be necessary to feed the mains cable around between the outside of the Base Housing and the Skirt to prevent the cable from being trapped. 3. Check all connections have been made correctly and ensure all terminal connections and cable clamps are securely fastened. 4. Ensure the impeller rotates and is free from obstructions. D. SERVICING AND MAINTENANCE. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE. 1. At intervals appropriate to the installation, the fan should be inspected and if required cleaned to ensure there is no build-up of dirt or other deposits. 2. If a filter is fitted, remove the filter and wash in warm soapy water. 3. Wipe the inlets and front face with a damp cloth until clean. 4. Once the filter is dry it can be replaced. The fan has sealed for life bearings, which do not require lubrication. 5

Fig. 1. Removing the grille Fig. 2. Attaching the spigot Fig. 3. Surface mounting screw hole locations Fig. 4. Converting outlet spigot for side exit and recess mounting 6

Fig. 5. Recess mounting clips In 3 positions. Fig. 6. PIR sensor cable - (TM only) To remove the cover on TM models the sensor lead must be disconnected Fig. 7. Settings LED position Top view of PCB cover showing pot locations And dip switch location Timer adjuster (T/HT/TM Models) To reduce time Turn anti-clockwise. To increase time Turn Clockwise. Humidity - adjuster (HT Model) To LOWER the set-point Turn Anti-clockwise. To RAISE the set-point Turn clockwise. T H - + - + 12V 0V LS Cable clamp must be used with surface wiring. Dip switch settings 1 = Trickle speed 2 = Constant trickle on or off 3 = Wall or Duct mode 4 = Delay-On timer on or off (Not on TM model) 7

IMPORTANT On first power up, the fan will run through its initialization routine. On T, HT & TM models the fan will switch on and off during this routine (Including the LED) Once complete after approximately 2 minutes, the fan will run as normal. Fig. 8. P/TM wiring diagram Fig. 9. T/HT wiring diagram 8

PRODUCT FICHE For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014) Name: Vent-Axia Vent-Axia Vent-Axia Vent-Axia Model ID (Stock Ref.) : Lo-Carbon Solo Plus SELV P - 427485 Lo-Carbon Solo Plus SELV T - 427486 Lo-Carbon Solo Plus SELV HT - 427487 Lo-Carbon Solo Plus SELV TM - 427488 SEC Class F E C C SEC Value ('Average') 13.97 15.72 26.23 26.23 SEC Value ('Warm') 6.32 7.11 11.86 11.86 SEC Value ('Cold') 27.32 30.75 51.31 51.31 Label Required? (Yes/No=Out of scope) No No No No Declared as: RVU or NRVU/UVU or BVU RVU-UVU RVU-UVU RVU-UVU RVU-UVU Speed Drive Multi-Speed Multi-Speed Multi-Speed Multi-Speed Type HRS (Recuperative, Regenerative, None) None None None None Thermal Eff: [ (%), NA(if none)] N/A N/A N/A N/A Max. Flow Rate (m3/h) 75.60 75.60 75.60 75.60 Max. Power Input (W): (@Max.Flow Rate) 8.40 8.40 8.40 8.40 LWA: Sound Power Level (db) 51.02 51.02 51.02 51.02 Ref. Flow Rate (m3/s) 0.01 0.01 0.01 0.01 Ref. Pressure Diff. (Pa) N/A N/A N/A N/A SPI [W/(m3/h)] 0.16 0.16 0.16 0.16 Control Factor & Control Typology: (CTRL/ Typology) Control Factor; CTRL 1.00 0.95 0.65 0.65 Local Demand Local Demand Control Typology Manual Control Clock Control Control Control Declared: -Max Internal & External Leakage Rates(%) for BVUs or carry over (for regenerative heat exchangers only), -&Ext. Leakage Rates (%) for Ducted UVUs; Mixing Rate of Non-Ducted BVUs not intended to be equipped with one duct connection on either supply or extract air side; Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A For UVUs (Instructions Install Regulated Supply/Extract Grilles In F&W In F&W In F&W In F&W Façade) Internet Address (for Disassembly Instructions) www.vent-axia.com www.vent-axia.com www.vent-axia.com www.vent-axia.com Sensitivity p. Variation@+20/-20 Pa: (for Non-Ducted Vus) N/A N/A N/A N/A Air Tightness-ID/OD-(m3/h) (for Non-Ducted Vus) N/A N/A N/A N/A Annual Electricity Consumption: AEC (kwh/a) 2.19 2.03 1.15 1.15 Annual Heating Saved: AHS (kwh/a) AHS: Average 13.97 15.72 26.23 26.23 AHS: Warm 6.32 7.11 11.86 11.86 AHS: Cold 27.32 30.75 51.31 51.31 9

Notes:- 10

Notes:- 11

The Guarantee Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local supplier. Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product:- Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label attached to the unit). Has not been subjected to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase. The guarantee is offered to you as an extra benefit, and does not effect your legal rights Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0844 8560595 Fax: 01293 539209 For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX 448551 E 0817 12