Stulz CyberMOD EC Fan Retrofit Kit Switch & Save

Similar documents
& EC Fan Retrofit Kit

ENERGY EFFICIENT RETROFITS. Date

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

Plenum Fans. Model HPA. Direct Drive

Liebert. CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

DAE Systems. Fan Selection Guide. Section 1: Terminology

Fan Arrays. White Paper. Energy Labs White Paper Series Volume 0412 Issue 001 April 2012 Rev. 0. Series

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

Selecting the Correct Fan

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Fan Selection. and Energy Savings

Multistage Centrifugal Blowers

INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

MCH Series Drives. HVAC Application Guide. ag-mch-e2

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Ducted Propeller. Airflow Volume

Automation and Energy Efficiency of Industrial Refrigeration Systems

LUCKILY THERE S A BETTER WAY

Multistage Centrifugal Blowers

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Service Step by Step Trouble-Shooting Check-List

DIRECT DRIVE BLOWER COILS

gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

MECHANICAL SERVICES 101. Ian White

David Reynolds, Business Development Manager. Halton Group Foodservice Division

Advance Release September 2009

Direct Fired Heater Model AD Specification

Integrated VarIable refrigerant flow ahu/pau (r410a)

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

How to Cut Chiller Energy Costs by 30%

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Unico Training. Class for R E Michel Salesmen

2200 SERIES VACUUM CONVEYOR Special Capabilities Specification Sheet

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

AcoustiFlo Fans: Retrofit Solutions and Beyond

ALL PRODUCTS BROCHURE

CHILLED WATER DATA ROOM UNITS

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

Compressed Air Systems. Scott Wetteland, CEM, DNV GL July 2018

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Fans: Features and Analysis

SCK. Air Compressors SCK 3-40 & ALLEGRO 8-11

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Selecting Fans and Determining Airflow for Grain Drying and Storage

THE CLEAR CHOICE FOR CLEANING

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Energy Efficient Fan and Dust Collection Systems

Multistage Centrifugal Blowers

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

Insulate your exterior walls. Air seal and insulate your attic

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Demand Control Kitchen Ventilation Cameron Ritzenthaler, Air Solutions & Balancing, LLC

Titus Quick Reference Guide ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

CSM hp. Oil-injected screw Compressors Belt driven. The perfect solution for the small businesses. TECHNOLOGY YOU CAN TRUST

Discover ebm-papst for buildings. Energy-efficient fans for a controlled room atmosphere.

Fan Array Systems WHITE PAPER. Rad Ganesh, PhD, P.E. Director, R&D / Applications Twin City Fan Companies, Ltd. Minneapolis, MN, United States

VariCool VAV Engineering Guide

Fan Arrangements, Rotation, Discharge and Motor Position

Modular Multi-position Air Handler

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

For performance and dimensional data, see back page.

Vacuum Systems. A complete line of vacuum pumps and accessories for every dairy

commercial refrigeration products

Liebert InteleCool Warranty Inspection Check Sheet

Compressed Air Systems

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Efficiency: The Ultimate Renewable Resource

Understanding Fan System Effects

INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

fans & heaters SIMPLE, ROBUST AND RELIABLE

within a Quality Management System ISO9001 and Environmental Management System ISO Sales Offices CERTIFICATION

Chore-Time Fan Guide For Tunnel and Other Applications

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Water-Cooled Self-Contained Units

Technologies for all vacuum F-Series Radial and pressure applications

Slim Contour Unit Cooler

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Troubleshooting the Indoor AHU as a Standard Product

Transcription:

Stulz CyberMOD EC Fan Retrofit Kit Switch & Save

Stulz CyberMOD Provides significant op-ex energy savings Reduces an existing data center s carbon footprint Improves a data center s reliability with fan redundancy Improves the performance of existing cooling equipment Extends the life of existing cooling equipment A low firstcost solution with big energy savings! Stulz CyberMOD Solves Problems

What is Stulz CyberMOD? An easy-to-install fan box designed to retrofit older Liebert brand CRAHs by replacing inefficient belt-driven forward curved, DWDI fans with efficient EC plug fans. Available in two and three fan designs Mounted in an aluminum box CRAH and Fan Controls Comes complete with E2 controller Wire harness for plug and play Wiring diagrams All electrical control components Special options are available Fits Liebert models: 740C 600C 529C 422C Mounted in existing Liebert models in the bottom area of the unit where blowers and motors are presently located. The existing components are removed and the box is designed to slide into this opening.

Stulz CyberMOD Features & Benefits Immediate 20%* energy savings in an apples-to-apples comparison by replacing existing centrifugal fans (based on an actual performance test) Over 60% energy savings possible when running at partial load (with built-in redundancy) Fully adjustable EC fan speed (no VFD required) *Savings estimate is derived from actual performance test results of (1) Liebert model FH740C with 10 hp forward curved centrifugal fan vs. (1) Liebert model FH740C modified with the Stulz EC Fan retrofit kit, at 16,500 cfm, against 0.3 of external static pressure. Results may vary. Stulz assumes no responsibility and disclaims all liability if other comparable tests produce different results. Better air distribution than forward curved fans Updated control options (under floor pressure control; return or supply air temp control; independent fan and valve control) Low first-cost big energy savings Fast payback / ROI May qualify for utility rebates

EC Fan Advantages over Centrifugal Fans Mechanical Advantage Electrical Advantage Large fans (operate at lower speeds, with lower energy, even air flow, provide redundancy) Quiet Operation (low vibration, no inverter whine) Low maintenance (no belts to adjust, no greasing) Clean (no belt dust, no grease) EC Fans more efficient at partial load (efficiency maintained from 30-100% of load range without VFD) Does not rely on incoming line frequency (more precise air flow) Lower motor power (higher net cooling capacity) Backward Curved Electronically Commutated (EC) Plug Fan AC Motor Belts & Pulleys Fan Forward Curved Belt Driven Centrifugal Blower (with or without VFD)

Less Energy 740c with 10hp motor and no VFD. Constant speed, constant air flow, constant energy use. 20% energy savings Same 740c with 10hp motor with a VFD installed (variable fan speed inefficiencies; energy penalty when running at 100%!) Stulz CyberMOD Based on actual test data!

Less Money Low first-cost (cap-ex) Significant energy savings (op-ex) 20% cost savings Reduce the existing data center s carbon footprint Qualify for utility rebates Based on actual test data!

Site Qualification Is Stulz CyberMOD right for your data center? Key Criteria: Unit Model 422, 529, 600, 740 Cooling Method CW Air Pattern Down flow Type of Control Number of Fans Dimensional Data Footprint and Blower Opening Take Pictures if you can

Thank you!