FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

Similar documents
HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

HCLEARFIRE. High-efficiency, modular steam boiler HP

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

PROFIRE -E SERIES BURNERS

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

INDUSTRIAL WATERTUBE BOILERS

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

The world s standard in efficiency. CBEX FIRETUBE

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

Solution builder. in energy management.

Cleaver-Brooks Webinars

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

Williams & Davis Boilers

You can view our archived webinars by going to

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

PACKAGED COMMERCIAL WATERTUBE BOILERS

Home Builder Product Selection Guide

Fast, Simple, & Easy to Use. One Company... Three Great Brands!

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Williams & Davis Boilers

FUEL-FIRED VERTICAL TUBELESS BOILERS

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Industrial Applications

Concrete Applications

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Fuel-Fired Vertical Tubeless Boilers

Boiler Basics: Design & Application Differences. Presented by Steve Connor July 30, 2014

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Now Available with PVC & Polypropylene Vent Configurations

G315/6 Cast Iron Boiler

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

G315/5 Cast Iron Boiler

SAMPLE SPECIFICATIONS

G515/7 Cast Iron Boiler

Triton Series High Efficiency Boiler

High Efficiency Commercial Gas Water Heaters

G615/11 Cast Iron Boiler

Guidelines for Preparing for a Temporary Steam Plant

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

GB Condensing Gas Boiler

Power Flame Incorporated

SECTION WATER-TUBE BOILERS

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

Suggested Specifications Prestige Excellence 110

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Power Flame Incorporated

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

Bosch Uni 7000F Cast Iron Hot Water Boiler

Distributed By: M&M Control Service, Inc Building Technologies

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Boilers Variable Fire Boilers

Burner Comparisons. Typical Competitor s Burner

DIVISION FINNED WATER-TUBE WATER HEATERS

Rental Boiler Specifications (Nebraska Boiler)

Vacuum Insulated Pipe

AM Rapid Recovery Water Heaters

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

THE RINNAI LUXURY SERIES TANKLESS WATER HEATERS ENERGY-EFFICIENT HOT WATER NEVER LOOKED SO GOOD

Fuel-Fired Vertical Tubeless Boilers. Classic, Edge, Tribute and VMP Models From 4 to 150 BHP (138-5,021 lbs/hr)

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

DIVISION FINNED WATER-TUBE BOILERS

FXLF-9. High Efficiency Water Heaters and Boilers

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

FINNED WATER-TUBE POOL HEATERS

Residential Product Selection Guide

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

SB615/310 Stainless Steel Condensing Boiler

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

ClearFire - Hydronic Startup Report

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER

Intelligent Heating for Your Home

MX RANGE PACKAGED STEAM BOILERS

An Introduction to True Modular Boiler Systems

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

DIVISION FINNED WATER-TUBE WATER HEATERS

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

GAS/LOW NOx SERIES. High or Low Pressure Steam Boiler. The most versatile industrial steam boiler in the world

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Domestic Hot Water Heaters and Boilers FTIIIC-6

Transcription:

FLX FLEXTUBE The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

Completely Integrated Boiler System Solution Flexible solutions for any application. Cleaver-Brooks designs and manufactures every major component of our boiler systems to work together, so your system is always operating at peak effi ciency and with the lowest possible emissions. As the demand for more effi cient, sustainable steam and hot water systems increases, fl exible solutions and combinations of boilers can deliver the best solution. The Cleaver-Brooks fl exible watertube boiler can be paired with other condensing or non-condensing boilers to divide the system load more effi ciently, so only the boilers you need to meet system demand will be operating at any given time. Whether a steam, hot water or hybrid solution, we can customize one to best meet the needs of your unique application. Conventional Hydronic Solution Modular Solution Integrated Control System Hybrid Solution 2

Fastest Online Response and Superior Load Tracking Boilers Compact footprint saves valuable square footage in a boiler room. Designs for steam or hot water in accordance with ASME Section I for 150 psig steam or ASME Section IV for 15 psig steam or 160 psig hot water. Optional design pressure to 250 psig steam or hot water in accordance with ASME Section I. Reduced emissions to less than 9 ppm on natural gas firing with #2 oil backup; noise level to less than 85 dba. Integrated package with both the pressure vessel design and burner design integrated and manufactured by Cleaver-Brooks; we offer a single source for a performance-proven and -tested package. This system delivers the highest operating efficiency in a complete UL-tested and -certified burner/boiler package for operation on #2 oil, natural gas or propane gas. Performance-guaranteed efficiency up to 81% on 125 psig steam and 85% on hydronic heating applications. For gas firing, burner turndown up to 10:1 is standard for gas firing with uncontrolled emissions. Thermal shock protection, rapid replacement with cool water in a hydronic heating boiler can be detrimental to many boiler designs. But the Flextube is designed to alleviate these thermal stresses, and as such, the FLX is warranted for 25 years against thermal stress occurrences. Integrated safety controls provide optimum water level safety monitoring and control, as well as solid state flame safeguard and optional UL-packaged Hawk Control* featuring parallel positioning, VFD and O 2 Trim. Applications include hydronic heating for universities, colleges, medical facilities, office complexes and airport facilities, and process steam applications such as hospitals, pharmaceuticals, manufacturing and laundry facilities, where quick steam and rapid load tracking are essential. * Hawk 1000 is standard on units 1250 and larger. Field-erectable for replacement of inefficient boilers that are inaccessible with a factory package, the FLX can be delivered as a field-erectable package (Model FLE) permitting access into limited entryways. This unit can be assembled in the existing boiler room, minimizing demolition of the existing boiler. Assembly of the pressure vessel does not require code welding. 3

The Latest Boiler Design Technology Delivers Superior Efficiency The FLX is a fully integrated, tested and certifi ed cul/ul boiler system that provides superior performance for a rapid return on your investment. The FLX is the apex of engineering-designed and -selected components that are singularly never greater than the total package, which means each contributes to the overall performance of an effi cient cost-effective package system. Cleaver-Brooks integration means the boiler, burner and controls are specifi cally designed to work harmoniously at peak effi ciency for each demand response. For steam applications, the FLX will provide a guaranteed steam quality of 99.5% for 125 psig or 15 psig. This is accomplished with our engineered drum internals and larger steam-drum on the size 1250 and larger units as standard and optional for our smaller units. HEAT EXCHANGER Five pass fireside heat transfer design is the culmination of our focuseddesign, dynamic analysis using functional engineering to provide optimum thermal efficiency in a smaller footprint than a traditional watertube design. Consisting of multiple tubes, each tube is precisely engineered with a specific bend pattern to provide thermal stress protection and gas flow direction without the addition of baffles or baffle shields. A fully water-cooled furnace ensures optimum heat transfer in a boiler s highest heat transfer zone and also minimizes heat loss through the casing. For easy field assembly or tube removal if needed, each Flextube is fitted with a special fitting that anchors the tubes to the upper and lower drums, eliminating welding the tubes to the drums. The vessel is encased with an insulted inner jacket and outer jacket to maintain an outer jacket temperature of approximately 120 F or less. COMBUSTION Utilizing the Cleaver-Brooks ProFire Forced Draft Burner, there is no guess work on combustion performance. Each packaged FLX is equipped with a fully tested and certified cul/ul packaged burner designed to work specifically with the FLX Heat Exchanger. Whether firing natural gas, propane gas or #2 fuel oil, standard operation is demand modulation offering optimum combustion efficiency from minimum firing to maximum firing. For FLX sizes 1250 and greater, linkage control is replaced with parallel positioning control using the Cleaver-Brooks HAWK 1000 Burner Management system. Options for controlled emissions are available to less than 9 PPM NOx on natural gas.

6 1 5 12 9 2 8 7 10 6 11 3 Components 1 Exhaust connection 2 Forced Draft Burner, Gas/Oil 3 Combustion air intake Parallel Positioning Servo Motors eliminates linkage loss, tighter fuel to air control for maximum combustion efficiency 5 Central Control Panel hinged to swing away from boiler side to permit access to boiler internals 6 Supply and Return Water Connections, flat face flange 10 7 Tangent Tube Construction full water-wall design for maximum heat transfer in the furnace chamber 11 Five-pass gas travel cross flow for maximum heat transfer efficiency 12 8 9 Rear door access to furnace chamber precludes removing burner for furnace access Hinged burner door for easy access to burner internals for inspection and maintenance Rugged base frame with minimum 3" pour refractory floor to minimize heat loss and firm foundation setting Removable side inner and outer access panels to tubes. Inner panels are insulated to provide a cooler outer surface reducing standby losses 5

Boilers MODEL FLE OPTION Fully Field Erectable When access to your boiler room is limited, but you want a factory completed packaged boiler to replace an old, inefficient one, the FLE is the solution. The FLE is factory-packaged after the hydro test of the pressure vessel. Each tube is properly marked to its location to each drum, and the base, front and rear walls, insulated casing, controls and burner are packaged separately in a single shipment for ease of access to the boiler room. PACKAGED BURNER V-SERIES and VE-SERIES The Ultimate in Performance Isolated downcomers are flanged to reduce clearance requirements and eliminate field welding Factory-insulated casing reduces assembly hours Front and rear walls are fully insulated eliminating the need for field refractory work Boiler base frame is fully insulated Burner is factory pre-wired and fuel trains are pre-piped and wired for ease of attachment Burner Management Controls are mounted and pre-wired in the burner panel ProFire Burner Offers: Low fan motor HP requirements Quiet operation Efficient low excess air capability (consistent and repeatable across firing range) Low CO performance (<100 ppm natural gas corrected to 3% O2) Ease of combustion setup with unique air damper Low NOx option available to meet the most demanding regulations, <9 PPM Up to 10:1 turndown on gas with uncontrolled emissions Up to 7:1 turndown on gas with controlled low NOx option

FLX Boiler Dimensions and Weights Boilers STEAM - IMPERIAL UNITS Model No. 150-250 300-350 00-600 700-900 1000-1200 1250 150 1650 1850 2100 2500 A. Boiler Height (inches) 86 90 95 109 109 113 113 121 121 19 19 B. Boiler Width (inches) 2 6 8 5 5 5 5 60 60 75 75 C. Total Length (inches) 108 11 139 168 205 252 267 278.75 297.75 306.75 336.75 Shipping Weight (lbs) 5,700 6,200 7,900 10,200 12,000 16,000 17,300 21,200 22,200 30,500 3,100 Operating Weight (lbs) 6,600 7,200 9,200 12,500 1,100 19,200 20,800 26,300 27,700 38,00 3,100 STEAM - METRIC UNITS Model No. 150-250 300-350 00-600 700-900 1000-1200 1250 150 1650 1850 2100 2500 A. Boiler Height (mm) 2,18 2,286 2,13 2,769 2,769 2,870 2,870 3,073 3,073 3,785 3,785 B. Boiler Width (mm) 1,067 1,186 1,219 1,372 1,372 1,372 1,372 1,52 1,52 1,905 1,905 C. Total Length (mm) 2,73 2,896 3,531,267 5,207 6,01 6,782 7,080 7,563 7,791 8,553 Shipping Weight (kg) 2,586 2,812 3,583,627 5,3 7,258 7,87 9,616 10,070 13,835 15,68 Operating Weight (kg) 2,99 3,266,173 5,670 6,396 8,709 9,35 11,930 12,565 17,18 19,550 HOT WATER - IMPERIAL UNITS Model No. 150-250 300-350 00-550 600 700-900 1000-1200 1250 150 1650 1850 2100 2500 A. Boiler Height (inches) 78 82 86 86 95 95 95.5 95.5 107 107 131.5 131.5 B. Boiler Width (inches) 2 6 8 8 5 5 5 5 60 60 75 75 C. Total Length (inches) 115 120 16 153 17 206 252.5 267.5 279.25 298.25 311.25 30.25 Shipping Weight (lbs) 3,900 5,000 6,100 6,100 8,500 10,000 12,800 13,800 16,900 17,700 2,300 27,200 Operating Weight (lbs),700 5,900 7,600 7,600 10,500 12,300 15,00 16,600 21,200 22,00 31,00 3,800 HOT WATER - METRIC UNITS Model No. 150-250 300-350 00-550 600 700-900 1000-1200 1250 150 1650 1850 2100 2500 A. Boiler Height (mm) 1,981.2 2,082.8 2,18. 2,18. 2,13 2,13 2,26 2,26 2,718 2,718 3,30 3,30 B. Boiler Width (mm) 1,067 1,168 1,219 1,219 1,372 1,372 1,372 1,372 1,52 1,52 1,905 1,905 C. Total Length (mm) 2,321 3,08 3,708 3,886,20 5,232 6,1 6,795 7,099 7,756 7,906 8,62 Shipping Weight (kg) 1,769 2,268 2,767 2,767 3,856,536 7,258 7,87 9,616 10,070 13,835 15,68 Operating Weight (kg) 2,132 2,676 3,7 3,7,763 5,579 8,709 9,35 11,930 12,565 17,18 19,550 Dimensions and specifications are subject to change without notice. Dimensions are for layout purposes only and not for construction. Measurements are in inches.

Total Integration goes far beyond boilers. For more than 80 years, Cleaver-Brooks has built a reputation for innovation in the boiler solutions industry. We remain committed to introducing technology and products that enable a more energy-efficient and environmentally friendly generation of steam and hot water. When you come to us for a fully integrated boiler solution, you can know that each element is created to the highest standards and all will work together seamlessly to give you a highly efficient and reliable solution. To learn more, please call or visit us online. Packaged Boiler Systems 221 Law Street, Thomasville, GA 31792 USA 800.250.5883 info@cleaverbrooks.com cleaverbrooks.com Boiler system icons are copyrights of Cleaver-Brooks, Inc. Printed in the USA 2016 Cleaver-Brooks, Inc CB-8188 8/16