NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Similar documents
2014 National Electrical Code & NFPA 70E/Arc Flash

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Chapter 1 General... 5

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

NFPA 70E Electrical Safety & Arc Flash Training

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

2011 and 2014 National Electrical Code Changes Residential Only

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

TOM BURNS, PLANNING DIRECTOR

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

IEC and NCCER Mapping for Year 1

Electrical Hazards and NFPA-70E: Protecting Your Employees

WIRING AND PROTECTION

ORDINANCE NO

Overview of Significant 2017 NEC Changes

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

NFPA 70E Edition Update

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

Electrical Safety Program

National Electrical Code

Electrical Safety Requirements

Arc Flash Protection Training - NFPA 70e Electrical Safety

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Revisions for the 2014 National Electrical Code

Electrical Tech Note 107

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

ELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015

NECA S System Approach to Electrical Safety for NFPA 70E

Electrical Preventive Maintenance (EPM) Program

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

2017 NEC Presented by: Russ LeBlanc

Title: Electrical Safety Effective Date: 11/28/2014 Control Number: THG_0038 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

Revisions for the 2011 National Electrical Code - Part 4

Spring Test 6 due 04/26/2013

ELECTRICAL SAFETY: QUALIFIED/NON QUALIFIED

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Revisions for the 2011 National Electrical Code - Part 1

2009 ELECTRICAL CODE REQUIREMENTS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

EFCOG Best Practice #213

Student Guide. Wiring Edition. Compliments of. Georgia EMC East Exchange Place Tucker, GA (770)

Safety Meeting Topic #37 NFPA 70E What is it?

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

NECA S System Approach to Electrical Safety for NFPA 70E

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Residential Wiring (2014 NEC) (Homestudy)

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

ll. Consistency Questions

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments.

EFCOG Best Practice #121

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

Electrical Safety Program.

SEL Arc-Flash Solutions

Centennial Energized Electrical Work Permit Instructions

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians.

Residential Wiring (2017 NEC) (Homestudy)

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

Portable Equipment. Equipment with electrical components suitable to be moved by a single person without mechanical aids.

NEC 2017 Changes and Their Effect Upon the ICT Industry

Fee $15 Course: NEC Changes 5 This course is valid for these credentials: Credential Description Cred Code Credit Hours

PANELBOARDS & BUILDING DISTRIBUTION

Instructor: L. Keith Lofland

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

Residential Wiring According to 2011 NEC (Homestudy)

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

SEL Arc-Flash Solutions

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

NECA & Salisbury Assessment Solutions Partnership

Part Two. Wiring Procedures CHAPTER 3. Design and Layout

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

Get it Right the First Time Avoid These Commonly Cited Errors

Residential Wiring According to the 2011 NEC

SECTION ISOLATED POWER SYSTEMS

Important Upcoming Dates

2009 WESTERN SECTION CODE PANEL QUESTIONS

Revisions for the 2014 National Electrical Code Part 3

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

TABLE 1-E (2017) Effective July 1, 2017

NFPA 70E Electrical Safety in the Workplace

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

How many time has your company been asked by an owner or customer to work on equipment energized?

Distribution Control Center Operator Training

Are Open Bottom Electrical Handholes a NEC Violation? Proposals to Change the 2002 NEC Traffic Signal and Roadway Lighting Related

S U B S T I T U T E O R D I N A N C E BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF CHICAGO: ARTICLE I ELECTRICAL CODE

ELECTRICAL POWER SYSTEMS

Photovoltaic (Solar) Array Installation Guide

Safety requirements for voltage testing instruments

Electrical Design Guidelines Table of Contents

Transcription:

A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work - NFPA 70E. Days 2: Practical applications of NFPA 70E - not just the typical Code lecture. Day 3-5: Practical side of NEC including important Code calculations, the best methods to find information quickly in the Code. Whether new to the NEC or a seasoned electrician or engineer, this class is all about learning how to use the Code. Our new practical applications and calculations requirements brings the workshop courses together, and relates to Article 250 and other articles of the National Electrical Code (NEC) as well as NFPA 70E. The practical applications and calculations section uses the code to perform calculations and solve common residential and industrial application issues, detect size conductors using tables, determine overcurrent protection (fuses and breakers), set motor overloads, and size starters, controllers, disconnects and conduits. You will also cover how to maintain your electrical systems with the correct grounding and bonding techniques. CLASS FORMAT: Classroom Lecture STANDARD CLASS SIZE: NTT recommends a class of no more than 35 participants to obtain the best results. NTT TO PROVIDE: Textbooks Classroom consumables Completion certificates Course syllabus, outline, table of contents, or training objectives Shipping and instructor travel logistics CLIENT PROVIDES: Classroom of 500 square feet or greater Projection screen, white board and/or flip chart(s) WHO SHOULD ATTEND: Electricians Mechanics Environmental health & safety personnel Apprentice and experienced HVAC technicians Supervisors working on or who oversee employees working on 50V or greater equipment Linemen & Utility workers Owners & managers Warehouse employees Maintenance Technicians Energy management personnel Fire Alarm Technicians Plant & facility maintenance technicians Building engineers Building managers & superintendents Plant & facility managers Stationary engineers Safety directors

COURSE AGENDA INTRODUCTION TO ELECTRICAL SAFETY History and overview of Electrical Safety Brief History of OSHA Overview of the OSHA Regulations and where Electrical Safety Regulations are found OVERVIEW OF THE NFPA 70E STANDARD Relationship to OSHA Regulations and how to implement the NFPA 70E Standard Article 90 Introduction to NFPA 70E overview Key definitions in Article 100 Determine the breakdown of responsibilities in your facility THE HAZARDS OF ELECTRICITY Basic of Electricity Arc Flash Hazard PPE Categories Electrical Hazards o Shock o Arc Flash o Arc Blast GENERAL REQUIREMENTS FOR ELECTRICAL SAFETY-RELATED WORK PRACTICES (ARTICLE 110) The Electrical Safety Program Training Requirements Relationships with Contractors Use of Equipment o Test Instruments o Portable Electric Equipment o Extension Cords o GFCI s Underground Electrical Lines and Equipment ESTABLISHING AN ELECTRICALLY SAFE WORK CONDITION (ARTICLE 120) The six-step LOTO process WORK ON OR NEAR EXPOSED ENERGIZED PARTS (ARTICLE 130) Limitations for working when exposed to energized parts Hazard analysis Energized Electrical Work permit requirements Energized Electrical Work permit Approval process Description of Safe Work Practices to be employed Energized Electrical Work permit Exemptions SHOCK PROTECTION BOUNDARIES Shock Risk Assessment Establishing Shock Protection Boundaries o Using the AC and DC tables Approach Requirements for Qualified Persons Approach requirements for Unqualified Persons ARC FLASH BOUNDARY The Arc Flash Risk Assessment Establishing the Arc Flash Boundary PPE within the Arc Flash Boundary Equipment labeling requirements OTHER PRECAUTIONS Alertness / Situational Awareness Blind Reaching Illumination Conductive articles being worn

2014 Conductive materials Confined or enclosed work space Doors or hinged panels Housekeeping duties Use of flammable materials Anticipating failure Routine opening and closing of circuits. Reclosing circuits after protective device operation PERSONAL AND OTHER PROTECTIVE EQUIPMENT General: Responsibilities Care PPE Specifics Other PPE INTERPRETING EQUIPMENT LABELS Arc-flash information Shock protection information Selecting PPE Boundary Selection USING THE TABLES Identifying equipment and tasks Applicability of the tables Determining the table parameters Determining equipment meets installation requirements Determining equipment has been properly maintained Selecting PPE WORKING WITHIN THE LIMITED APPROACH BOUNDARIES TO OVERHEAD LINES Applicability Specific requirements Which rules apply: Applicability of other rules and standards o 1910.269 o NESC SAFETY-RELATED MAINTENANCE REQUIREMENTS General maintenance requirements Substations, switchgear assemblies, switchboards, panelboards, motor control centers, and disconnect switches Premises wiring Controller equipment Fuses and circuit breakers Rotating equipment Hazardous (classified) locations Batteries and battery rooms Portable electric tools and equipment Personal safety and protective equipment SAFETY REQUIREMENTS FOR SPECIAL EQUIPMENT Electrolytic Cells Batteries and Battery Rooms Safety-Related Work Practices for Use of Lasers Power Electronic Equipment Research and Development Laboratories

The purpose of the 2014 NEC is the practical safeguarding of persons and property from hazards arising from the use of electricity. The requirements in the 2014 NEC address the fundamental principles of installation for safety. NEW OR REVISED ARTICLES FOR 2014 Article 393 Low Voltage Suspend Ceiling Power Distribution Systems Article 646 Modular Data Centers Article 728 Fire Resistant Cable Systems Article 750 Energy Management Systems Symbol requirements for controlled receptacles DC voltage requirements expanding Increasing the voltage threshold from 600 volts to 1,000 volts Electrical Safety labeling requirements changing and new sections added Increased requirements for GFCIs in laundry areas, facilities like car washes, and generator receptacles AFCI requirements expanding into laundry rooms and kitchens as the NEC move towards wholehouse protection New section on Ground Fault Protection of equipment Exception for XHHW-2 conductors for specified temperature corrections for ampacity values Mounting of luminaires Increasing receptacle requirements in health care facilities Deleting the term Emergency Systems in health care facilities Moving several definitions from individual articles to Article 100 ALTERNATE ENERGY, GREEN TECHNOL- OGIES, AND IT EQUIPMENT CHANGES Revised Article 625: Updates on safe battery charging for plug-in hybrid vehicles that reduce the risk of explosion Revisions to Article 645: IT Equipment New Article 694: First-time requirements for small wind electric systems Revised Article 705: Interconnecting generators, windmills, and solar and fuel cells with other power supplies New Article 840: The increased demand for broadband communication systems with requirements for wireless, routers, and wireless disconnects OTHER REQUIREMENTS FOCUSED ON WORKPLACE SAFETY Provisions on electrical installations over 600 volts 240.87: Means to reduce incident energy New Article 399: Incorporates requirements for overhead distribution systems for large electrical system users, such as school or business campus settings 408.4B: Labeling at subpanels to identify feeder supply source 450.14: Disconnecting means for transformers NEC COURSE AGENDA APPLYING THE NEC ARTICLE 90 NEC process and definitions Equipment examination Code change introduction Metric and standard units ELECTRICAL INSTALLATIONS ARTICLE 110 Approval Conductors Equipment Mechanical installations Mounting and cooling Electrical connections Arc flash protection Spaces about electrical equipment

NEC COURSE AGENDA, continued BRANCH CIRCUITS AND FEEDERS ARTICLE 210 Branch circuits Review of Code changes Branch circuit ratings Multiwire branch circuits Identification of ungrounded conductors Color code for branch-circuit grounded conductors Color code for branch-circuit equipment grounding conductors Receptacle and cord connectors Replacing receptacles Dwelling units Bathrooms Garages and accessory buildings Buildings Other than dwelling units Required branch circuits Branch-circuit ratings 210.19 Minimum size conductors Overcurrent protection Feeders Minimum rating and size Feeders with common neutral Identifying high-leg in Delta 4-wire systems Ground-fault protection of equipment SERVICES ARTICLE 230 Definitions Service limitations Number of services Conductors outside of buildings Service raceways and seals Clearance from openings Overhead service-drop conductors Underground service-lateral conductors Service-entrance conductors Service Equipment AIC rating Identification Disconnecting mmeans Ground-fault protection of equipment CONDUCTORS AND OVERCURRENT PROTECTION ARTICLE 240 Conductors Ampacity Insulation ratings Ambient temperature Overcurrent protection Protection of conductors Ampere ratings Location of overcurrent protection devices Underground conductor Grounded conductor Circuit location Overcurrent Devices Plug and cartridge fuses Circuit breakers CB markings GROUNDING & BONDING ARTICLE 250 Grounding terminology Grounding systems Grounding equipment and enclosures Grounding means Bonding Services Bonding over 250 volts Main and equipment bonding jumpers

NEC COURSE AGENDA, continued Grounding Electrode System Part III Equipment Grounding Conductors WIRING METHODS ARTICLE 300 Wiring Methods Conductors of same circuit Conductors of different systems Protection from physical damage Underground installations Protection against corrosion Mechanical continuity of raceways and cables Length of conductors at outlet box Boxes, conduit bodies, or fittings required Supporting conductors in a vertical raceway Preventing heating effects of inductive current in metallic parts Securing integrity of fire-resistant-rated walls Preventing spread of toxic fumes in an air-handling system WIRING MATERIALS RACEWAYS AND BOXES ARTICLE 300 Raceway systems Rigid metal and nonmetallic conduit Electrical metallic tubing Flexible metal conduit Liquid-tight flexible metal and nonmetallic conduit Cable Assemblies Metal-clad cable Armored cable Nonmetallic-sheathed cable Other wiring systems Cable Tray Systems Wireways Busways Auxiliary gutters Boxes, Conduit Bodies, and Fittings WIRING MATERIALS Switches Article 404 Switchboards and panelboards ARTICLE 408 Panelboards Number of overcurrent devices on one panelboard Grounding of panelboards EQUIPMENT FOR GENERAL USE ARTICLE 400 Flexible Cords and Flexible Cables Luminaries Article 410 Luminaries locations Flush and recessed fixtures Electric-discharge equipment 1000 volts or less Lighting track Receptacles, cord connectors and attachment plugs Tamper resistant receptacles Grounding and non-grounding receptacles Isolated-ground receptacles Hospital-grade receptacles GFCI-type receptacles Appliances Article 422 Installation requirements Disconnecting means Safety provisions Markings MOTORS, GENERATORS, A/C & REFRIGERATION, AND FIRE PUMPS Motors Article 430 Review of Code changes Ampacity and motor ratings Markings on motors and multimotor equipment and controllers Branch circuit single motor

NEC COURSE AGENDA, continued Motor control circuits and centers Disconnecting means MOTORS, GENERATORS, A/C & REFRIGERATION, AND FIRE PUMPS, CONTINUED A/C and Refrigeration Equipment Article 440 Single equipment Disconnecting means Branch-circuit fuses or circuit breakers Room A/Cs Part VII Fire Pumps Article 695 Power source to electric-motor driven fire pumps TRANSFORMERS ARTICLE 450 Transformer construction and types Transformer installation Transformer vaults SPECIAL LOCATIONS ARTICLE 500 AND 600 Electrified truck parking spaces ARTICLE 626 Hazardous locations Article 500 Group classifications Wiring methods Conduit seals Motors and generators Grounding Intrinsically safe systems Service and Repair Garages Article 511 Health care facilities Places of assembly