TEST REPORT No

Similar documents
TEST REPORT No

TEST REPORT No /9943/CPR

TEST REPORT No

TEST REPORT No

What can we do for you?

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Initial Test Typing Leak test

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

VS LD series vertical steam sterilizers

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Understanding Etched Foil Flexible Heaters

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

Fiber Optic Cable Fence Disturbance Sensor

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

2408/2900. Fire Guard

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

2409/2900. Fire Guard

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

FDC/ -B. Product information SYSTEM TECHNOLOGY FOR THE DOOR ECO

Updated 04/07/2017 Page 1/8

INTERNATIONAL STANDARD

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

mirage standard response concealed pendent sprinkler vk492 (K5.6)

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

oem OEM 1" Between the Glass Metal Blind Series P2100 Included:

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

GASTEC QA. Approval Requirements 6

NWA PROFILE WRAPPING MACHINES INTERIOR

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

ASSEMBLY & OPERATING INSTRUCTIONS

SECTION AIR DOORS

This document is a preview generated by EVS

NERGYTOWER. energytower Leader in style, quality and safety. ground distribution turrets

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

TTOWNHOUSE SASH WINDOW SASH WINDOW

Technical Guidance CE Marking of Metal Chimneys and Flues

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Elements Headwall System (P2008A)

Oil burners fuel unit with solenoid valve

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Standard Spray concealed horizontal sidewall sprinkler VK481

TEST REPORT FIRES-FR AUNE

TFI Report Classification

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

INTERNATIONAL STANDARD

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

INTERNATIONAL STANDARD

Summary of fire ratings for Lorient seals fitted to AS fire door assemblies

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

Ceiling swirl diffusers

2. References EN 13829:2001. Thermal performance of buildings. Determination of air permeability of buildings. Fan pressurization method.

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

GOBLET. Urban Lighting Luminaire. Registered models - Design Massimo Sacconi

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Ceiling swirl diffusers

SPIDER P SPIDER P mineral

Architectural and Engineering Specification for a Personal Alarm System System (PAS)

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

Co170 ARMOURED WALL BURGLAR PROOF GRADE 2 ACCORDING TO UNI EN1143

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Mixing Division. Industrial Mixers. MIX S.r.l. MIXING SYSTEMS AND COMPONENTS FOR PLANTS. ATEX RANGE AVAILABLE CM/172

INTERNATIONAL STANDARD

DIRECTIVE NO: D-B

CI/SfB (22.3) Rn8. the economy cubicle and service concealment system

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

BOILER FOR HOT WATER AND STEAM

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

GENERAL SPECIFICATION ELECTRICAL

CERTIFICATE OF FIRE APPROVAL

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

CESI EXTENSION D. 02/12 ~ FGH ~ to EC-Type Examination Certificate CESI 03A TEX057X Equipment: Explosion proofsolenoid series OA-; OZA; MZA-A- Manufac

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

Design & Construction Standards, Revised January

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

A. Section Masonry Assemblies: Anchor placement in masonry.

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

ISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies

Revisions to this application specification include: Updated document to corporate requirements Changed product types in table in Figure 6

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

GV Standard X-Vent Operation and Maintenance Manual

Transcription:

Istituto Giordano S.p.A. Via Rossini, 2-47814 Bellaria-Igea Marina (RN) - Italia Tel. +39 0541 343030 - Fax +39 0541 345540 istitutogiordano@giordano.it - www.giordano.it PEC: ist-giordano@legalmail.it Cod. Fisc./Part. IVA: 00 549 540 409 - Cap. Soc. 1.500.000 i.v. R.E.A. c/o C.C.I.A.A. (RN) 156766 Registro Imprese di Rimini n. 00 549 540 409 TEST REPORT No. 341289 Place and date of issue: Bellaria-Igea Marina - Italy, 12/04/2017 Customer: SESAMO S.r.l. - Strada Gabannone, 8/10-15030 TERRUGGIA (AL)- Italy Date test requested: 21/03/2017 Order number and date: 72654, 22/03/2017 Date sample received: 30/03/2017 Test date: 31/03/2017 Purpose of test: air permeability of a sliding door in accordance with standard UNI EN 1026:2016 and classification in accordance with standard UNI EN 12207:2017 Test site: Istituto Giordano S.p.A. - Via Erbosa, 72-47043 Gatteo (FC)- Italy Sample origin: sampled and supplied by the Customer Identification of sample received: No. 2017/0716 Sample name* The test sample is called ERMETIKA. (*) according to that stated by the Customer. Comp. AV Revis. PB This test report consists of 17 sheets. This document is the English translation of the test report No. 341289 dated 12/04/2017 issued in Italian; in case of dispute the only valid version is the Italian one. Date of translation: 27/04/2017. CLAUSES: This document relates only to the sample or material tested and shall not be reproduced except in full without Istituto Giordano s written approval. Sheet 1 of 17

(Test report No. 341289 dated 12/04/2017) sheet 2 of 17 follows Description of sample* The test sample is a solid-panel automatic sliding door comprising: wrap-around frame covering the outside of the clear opening and gap for door seals made from extruded anodised-aluminium section with the following characteristics: well-rounded corners; no sharp edges; area for installation of screws/wall plugs; silicone-rubber seal to cover fixing points; door operator guaranteeing airtight closure comprising: high-performance low-wear DC gear motor with encoder fitted to motor casing; electronic control unit employing Sesamo Dualcore technology with dual processor and integrated switching power supply; drive system with antistatic timing belt having internal steel-cord reinforcement; heavy-duty extruded-aluminium track designed for fixing to standard walls and self-supporting systems; extruded anodised-aluminium guide rail designed for horizontal and downward travel in order to allow the leaf to move towards the wrap-around frame and create an airtight seal by compressing the seals; anodised-aluminium cover with well-rounded corners and no sharp edges or protrusions; leaf formed by: anodised-aluminium extrusions with well-rounded corners designed to withstand high pressure. The heavy-duty top extrusion has a slot for insertion of hanger fixings. On the other hand, the bottom extrusion is shaped in such a way as to form a track for the runners secured to the base of the mock-up (floor); flush-fitting door leaf panel of thickness 60 mm comprising a flame-retardant, expanded-polystyrene core enclosed by fire-resistant MDF edge strips; the entire panel is clad by two fire-resistant MDF panels of thickness 4 mm and faced with two layers of plastic laminate of thickness 0,9 mm; 60Sh/A silicone-rubber perimeter bulb seals and bottom lip seal designed to provide optimum airtightness; runners designed to slide/move and keep the leaf in the correct position in order to obtain an airtight seal; three heavy-duty roller hangers designed to guarantee sliding/linear motion towards the wrap-around frame. (*) according to that stated by the Customer; the description of the sample also includes Customer-supplied drawings as set out hereafter.

(Test report No. 341289 dated 12/04/2017) sheet 3 of 17 follows Leaf airtightness is obtained from a combined movement during closure that compresses the seals fitted to the leaf against the wrap-around frame. Sample dimensions are as follows: Opening height Opening width Clear opening height Clear opening width Leaf height Leaf width 2118 mm 1365 mm 2110 mm 1350 mm 2152 mm 1450 mm Customer-supplied list of materials The mock-up includes the following hardware: 1 elbow-operated push button; 1 logic switch offering the following types of operation: stop close; stop open; automatic; only exit; partly open; manual opening; reset; battery operation. 1 set of storage batteries for opening in event of power outage; 1 D-shaped pull handle to facilitate manual opening of the leaf.

(Test report No. 341289 dated 12/04/2017) sheet 4 of 17 follows SAMPLE ELEVATION (CUSTOMER-SUPPLIED) A 3000 2577 B B A

(Test report No. 341289 dated 12/04/2017) sheet 5 of 17 follows SECTION A:A (CUSTOMER-SUPPLIED) Porta chiusa Close position A-A Porta aperta Open position A-A 2118 2110 2152 2170

(Test report No. 341289 dated 12/04/2017) sheet 6 of 17 follows SECTION B:B (CUSTOMER-SUPPLIED) 1365 Porta chiusa Close position B-B 500 1450 1470 Porta aperta Open position B-B 1350

(Test report No. 341289 dated 12/04/2017) sheet 7 of 17 follows Sample measurements Overall dimensions width 1470 mm height 2170 mm Operable dimensions width 1450 mm height 2150 mm Overall area 3,190 m² Operable area 3,118 m² Operable perimeter 7,20 m Normative References The test was carried out in accordance with the requirements of standard UNI EN 1026:2016 dated 14/04/2016 Windows and doors - Air permeability - Test method with test parameters and classification of results according to standard UNI EN 12207:2017 dated 26/01/2017 Windows and doors - Air permeability - Classification. Test apparatus The test was carried out using a computerised semiautomatic control and measurement system capable of performing all tests with the parameters requested by the normative references and fitted with the following equipment: for the measurement of air leakage rate: pressure differential devices (orifice plates, nozzles and Venturi tubes) compliant with standards ASME MFC-14M:2003 Measurement of fluid flow using small bore precision orifice meters, UNI EN ISO 5167-1:2004 dated 01/10/2004 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements and UNI EN ISO 5167-2:2004 dated 01/10/2004 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates ; for measurement of pressure inside the test chamber: differential pressure transducers; Mitutoyo Corporation 5500 mm digital tape measure.

(Test report No. 341289 dated 12/04/2017) sheet 8 of 17 follows Pre-test conditioning of sample The sample was conditioned for four hours immediately prior to testing under the environmental conditions specified in the following table. Temperature (18 ± 3) C Relative humidity (48 ± 10) % Environmental conditions during test Atmospheric pressure (1020 ± 10) hpa Ambient temperature (18 ± 1) C Relative humidity (48 ± 5) % Test method The test was performed using detailed internal procedure PP049 in the revision applicable at time of testing. The sample was fitted to the test apparatus and subjected in sequence to: measurement of air permeability under positive pressure; measurement of air permeability under negative pressure. Test results The test results are set out hereafter in the form of photos, tables and respective graphs.

(Test report No. 341289 dated 12/04/2017) sheet 9 of 17 follows Sample photo

(Test report No. 341289 dated 12/04/2017) sheet 10 of 17 follows Sample close-ups Measurement of air permeability under positive pressure Nota per il compilatore:

(Test report No. 341289 dated 12/04/2017) sheet 11 of 17 follows Pressure Air flow rate* nominal test total related to overall area and relative uncertainty** related to opening joint length and relative uncertainty** [Pa] [Pa] [m³/h] [m³/h m²] [m³/h m] 50 51 1,23 0,386 ± 0,023 0,171 ± 0,010 100 98 1,96 0,614 ± 0,028 0,272 ± 0,012 150 150 2,77 0,869 ± 0,051 0,385 ± 0,023 200 199 4,47 1,40 ± 0,39 0,62 ± 0,17 250 248 17,90 5,6 ± 3,1 2,5 ± 1,4 300 298 103,01 32 ± 13 14,3 ± 5,9 450 448 913,18 286 ± 32 127 ± 14 600 599 1773,62 556 ± 45 246 ± 20 (*) figures refer to pressure of 101,3 kpa and temperature of 293 K. (**) uncertainty considers contributions caused by measurement of the following quantities: air flow rate, test chamber pressure and size of sample; expanded uncertainty has been calculated using a coverage factor k of 2, corresponding to a confidence level of 95,45 %. Observations: //

(Test report No. 341289 dated 12/04/2017) sheet 12 of 17 follows DIAGRAM OF AIR PERMEABILITY RELATED TO OVERALL AREA (positive pressure) 1000,0 100,0 Flow rate [m³/h m²] 10,0 1,0 0,1 10 100 1000 Pressure [Pa]

(Test report No. 341289 dated 12/04/2017) sheet 13 of 17 follows DIAGRAM OF AIR PERMEABILITY RELATED TO OPENABLE JOINT LENGTH (positive pressure) 1000,0 100,0 Flow rate [m³/h m] 10,0 1,0 0,1 10 100 1000 Pressure [Pa]

(Test report No. 341289 dated 12/04/2017) sheet 14 of 17 follows Measurement of air permeability under negative pressure Pressure Air flow rate* nominal test total related to overall area and relative uncertainty** related to opening joint length and relative uncertainty** [Pa] [Pa] [m³/h] [m³/h m²] [m³/h m] 50 51 1,05 0,329 ± 0,022 0,146 ± 0,010 100 99 1,59 0,498 ± 0,024 0,221 ± 0,011 150 149 2,03 0,635 ± 0,024 0,281 ± 0,011 200 199 2,30 0,720 ± 0,026 0,319 ± 0,011 250 249 2,64 0,829 ± 0,030 0,367 ± 0,013 300 300 2,99 0,936 ± 0,032 0,415 ± 0,014 450 451 3,84 1,203 ± 0,040 0,533 ± 0,018 600 599 4,51 1,414 ± 0,047 0,626 ± 0,021 (*) figures refer to pressure of 101,3 kpa and temperature of 293 K. (**) uncertainty considers contributions caused by measurement of the following quantities: air flow rate, test chamber pressure and size of sample; expanded uncertainty has been calculated using a coverage factor k of 2, corresponding to a confidence level of 95,45 %. Observations: //

(Test report No. 341289 dated 12/04/2017) sheet 15 of 17 follows DIAGRAM OF AIR PERMEABILITY RELATED TO OVERALL AREA (negative pressure) 100,0 10,0 Flow rate [m³/h m²] 1,0 0,1 10 100 1000 Pressure [Pa]

(Test report No. 341289 dated 12/04/2017) sheet 16 of 17 follows DIAGRAM OF AIR PERMEABILITY RELATED TO OPENABLE JOINT LENGTH (negative pressure) 100,0 10,0 Flow rate [m³/h m] 1,0 0,1 10 100 1000 Pressure [Pa]

(Test report No. 341289 dated 12/04/2017) sheet 17 of 17 follows Classification In accordance with the tests performed, the results obtained and the provisions of standard UNI EN 12207, the test sample comprising a sliding door called ERMETIKA submitted by the company SESAMO S.r.l. - Strada Gabannone, 8/10-15030 TERRUGGIA (AL) - Italy, is awarded the performance classes listed in the following table. Air permeability under positive pressure Air permeability under negative pressure Test type related to overall area Test standard Classification standard Class* related to opening joint length UNI EN 1026 UNI EN 12207 1 final 2 related to overall area related to opening joint length UNI EN 1026 UNI EN 12207 4 final 4 (*) classification has been determined on the basis of values obtained by measurement during testing in line with clause 2.6 of ILAC- G8:03/2009 Guidelines on the reporting of compliance with specification. 2 4 The results given refer exclusively to the test sample itself and are only valid under the same conditions in which testing was carried out. This test report alone shall not be considered a certificate of conformity. Test Technician: Dott. Ing. Paolo Bertini Head of Security and Safety Laboratory: Dott. Andrea Bruschi Chief Executive Officer... The original of this document consists of an electronic document with a digital signature affixed pursuant to DPR (Presidential Decree) 513/97.