DR30 MAX Warewash Chemical Dispenser Dispensing technology by Seko UK

Similar documents
QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

D3000. Installation & Setup Guide

Sprite III Warewash Dispensing System

DEMA CHEMASTER WAREWASH SYSTEM INSTALLATION AND OPERATIONS MANUAL

Dosing systems for dishwashing machines TWINDOSE SERIES

Warewash Systems. innovation > technology > future

Warewash systems. innovation > technology > future

SPRITE Warewash Dispensing System

Antares Warewash Dispensing System

PUMP PROPORTIONING PRODUCTS

NS1000E Installation & Troubleshooting

Warewashing individual and integrated systems

Installation & Operators Manual

INSTRUCTION BOOK. BioDoser. Simple, Fully Programmable Dosing System. BioDoser. Version 1.0b, 25-Oct Please read before you call us for advice.

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

Retro Fit Rinse Pump Rev B

Glass and Dishwashers AMX / AUX Series

INSTRUCTION MANUAL FOR DEMA CHEMASTER TM DM-813-LLL-1T, DM-813-LLL-2T, DM-813-DLL-1T and DM-813-DLL-2T

Installation & Operators Manual

OPERATION AND MAINTENANCE MANUAL DETERGENT PERISTALTIC PUMPS RINSE AID PERISTALTIC PUMPS

Electronic Dual Cylinder Thermostat Installation Instructions

REMOTE COOLER AIR COOLED & WATER COOLED

SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

digital multifunction peristaltic dosing pumps

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

The Classeq under counter range

Glass and Dishwashers AMX / AUX Series

Mix Boiler & Font Range ( #, #, #, , )

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Service Parts

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Product waste disposal - Protection of the environment:

Single Pumps_ 2 Double Pumps _ 4. Air freshener dosing pump for air-conditioning equipments _ 7 Car Wash_ 7 Enzyme dosing pumps_ 8

Laundry Dosing Systems

MIX Boiler & Font Range Service Manual

DEMA 830 Laundry Master TM Installation Instructions

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

D3000. The reliable, quick-to-install dispenser!

TH100 Three in One Instant Hot Water Tap

Service Engineers Manual (for software version ) Duo 2 Duo 3 Duo 500 Duo 750

Digital Marine Exhaust Temperature Alarm

Sprite III (Alpha) Warewash Dispensing System

GREY line. CE Series Hood dishwashers

SCHWAN INSTALLATION GUIDE

LC3000 Level Controller Installation and Maintenance Instructions

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

Marco Beverage Systems Ltd.

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

Service Parts

RF Programmable Room Thermostat Installation Instructions

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

Dishwasher technical manual

D3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION

PAC1500Xi PORTABLE APPLIANCE CHECKER

innovation > technology > future

Installation, Operation & Maintenance Manual. Wash System

The Classeq pass Through range

WAREMAX SERIES. Dosing Systems for Commercial Dishmachines. Contents. WAREMAX Series Dishwasher systems. 4 Priming and Delime Mode.

Service Parts

EcoSmart boiler SERVICE MANUAL

Antares Warewash Dispensing System

PARTS BOOK. From S/N:

Instruction Manual Machine P/N: # & #

M1C. Operator Manual

4L Instant Water Boiler Instructions for Use

Service Parts

Ecoboiler SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Laundry. a wide range of automatic peristaltic dosing systems. innovation > technology > future

systems europe Laundry & Warewash Product Catalogue

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Mira Sport Max with Airboost

Engineers manual. Pass Through machines P500 P500 A P500 AS P500 A WS P500 AS WS. A- AirBreak WS Water Softener. AS Dual Rinse Element

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Norris Upright Dishwasher

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

HX-30/40 and HX-30/40 S Glass and Dishwashers

11/2012. Mod: D281/EKA-NP. Production code:

Bx OVEN SET UP AND OPERATION OF OVEN AND CONDENSER UNIT (IF FITTED) CLASSIC

DOMESTIC STEAM GENERATOR Installation Instructions

MODEL CMA-130VL PARTS MANUAL Rev 1.00

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

SERVICE MANUAL UBER FONT

PARTS MANUAL Rev 1.00B DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA FAX

PERFORMANCE SHOWER PRODUCTS

LC2200 Level Controller Installation and Maintenance Instructions

EVG Extractors. Manual for Installation, Use and Maintenance

T5 ( ) T10 ( ) PB5 ( ) PB10

EZT90BL Extractor. Installation, Use and Maintenance.

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Operating instructions

Inspect bath carefully and report any damage or faults before installation. No claims can be entered in to after installation.

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

GRANULE GASTRO EXTRA POWERFUL FOR KITCHENS USING A LARGE NUMBER OF GN TRAYS.

FMH Range Hoods. Installation, Operation & Maintenance Instructions

EVP61/91/101/121. Extractor. Installation, use and maintenance.

Transcription:

DR30 MAX Warewash Chemical Dispenser Dispensing technology by Seko UK 400-2003-00

A total commitment to guaranteed reliability and optimal performance has led to Seko being utilised in many types of industry. Including food and beverage, agriculture,dairy and water treatment. We operate to the highest quality standards of (ISO 9001) In manufacturing, R&D and product testing. We have experienced staff and a network of specially appointed distributors around the world to provide local support. Dispensing Technology for your Industry Please visit our web site or contact us for details on our Laundry Dispensing Products, Drain Enzyme Pumps, Blending Stations, Sprayers and Foamers. www.sekouk.com

SAFETY INFORMATION Any maintenance or servicing of Seko equipment should only be carried out by a competent professional and any electrical work by a qualified electrical engineer. Always isolate Seko equipment from any electrical supply or external machine which supplies electrical signals. This must be done prior to carrying out any mechanical or electrical installation, repair or maintenance. FAILURE TO DO SO MAY RESULT IN SPILLAGE OF CHEMICAL, DAMAGE TO EQUIPMENT OR PERSONAL INJURY All Seko equipment should be wired to a mains supply via a two pole isolating switch, in accordance with the relevant electrical standards. Seko equipment fitted with an on/off switch may be wired to a 13Amp mains plug fused at 3 Amps, for connection to a 13 Amp socket Always observe appropriate precautions against chemical contact. Refer to the chemical providers COSHH data sheets prior to changing chemical containers or peristaltic tubes

CONTENTS INSTALLATION GUIDELINES CONTENTS PART 1 Mechanical Installation Electrical Connections Probe Installation PART 2 Routine Maintenance PART 3 Set up Procedure TECHNICALSPECIFICATION Voltage Signal Inputs Tubing Flow Rate Rollers Enclosure Motors Approvals Weight 210-230vac 50-60Hz 24v AC/DC to 230v AC/DC Opto Isolated STD EPDM ( SILICONE on Request ) Detergent 200ml/Min Rinse 70ml/Min Acetal IP65 260mm x 180mm x 90mm 12v dc EMC89/336/EEC EN50081-1 LVD 72/23EEC 2.3Kg

PART 1 MECHANICAL INSTALLATION Locate the DR30 unit as close to the Dishwasher and chemical containers as possbile, whilst taking care to avoid direct heat, moisture or steam. The PVC tubes from the chemical containers should ideally be no longer than 3 Metres. The fixing holes in each corner of the dispenser (with the lid open) should be used to fix the enclosure to the wall in order to maintain the waterproof sealing. Connect the tubing from the chemical container to the inlet connector of the relevant pump. Warming the pvc will assist when fitting Site the detergent tank connector above the water line of the dish-washer away from the drain point. Drill a 6mm hole if using the M6 stainless steel connector, or a 13mm hole if using 1/4 inch BSP. Connect the pvc tubing from the outlet of the Detergent Pump to the tank fitting. Again warming the tube will assist with fitting Connect the 1/8 BSP Rinse non return valve outlet into the boiler. If a hose connection is required for the non return valve these can be ordered from Seko uk Due to the pressure in the Rinse delivery line 4x6 Nylon or PE(dependant on chemical compatibility) tubing is recomended This can be supplied on request Ensure suction and delivery tubes are not kinked or resting on hot pipework

PART 1 ELECTRICAL INSTALLATION Operation from single solenoid machines. Common rinse valve. Always ensure the supply to the DR30 is switched off before opening The DR30 supply must be wired via a local isolator switch ALL ELECTRICAL WORK SHOULD ONLY BE CARRIED OUT BY A QUALIFIED ELCECTRICAL ENGINEER Connect the mains supply to the 6-way NLE terminal block. If the power supply is the same as the dishwasher, so that the unit powers up with the machine. It is possible to select the POWER UP option in the set up menu for the initial fill. Connect Sig 2 to the switched side of the solenoid). For 230v Solenoids only one wire is needed from the switched side of the solenoid, and the remaining connection can be connected to the mains neutral (or to Live if the solenoids are Neutrally switched) SIG 1 can also be used for initial fill (if selected in the menu) as it has a 30 second delay enabling it to be used from a common rinse/fill valve. Sig 2 Sig 1 Common N L E Operation from Dual Solenoid machines. Separate Fill and Rinse Valve. Sig 1 to the Fill valve and Sig 2 to the Rinse valve. Common Sig 2 Sig 1 To Rinse Solenoid To Fill Valve N L In this variation the Detergent initial fill is dosed by Sig 1 There is a 30 second qualification time on sig 1, so it will only operate if the signal is present for 30 seconds. This is to allow for partial fill of the tank prior to chemical dosing E 3

PART 1 PROBE INSTALLATION Mechanical Electrical The probe should be sited in the wash tank away from the heating element and water supply. Drill a 21mm hole approx 75mm above the bottom of the wash tank. It is very important that the probe is completely below the water line, particularly when the main wash pump is operating and causing turbulence The probe should be sited just below the detergent injection point. Connect 2 core cable onto the probe by crimping each cable onto the push-on bullet crimp tags provided. Connect the other end of the 2-core cable to the probe terminals of the grey terminal block. The polarity is not important. Probe Sig 2 Pump Common N L E 2 core cable to probe To be connected to the Polarity not important Rinse Solenoid Note Sig 1 terminal is not used in probe mode unless sig 1 control is selcted. If you select YES to sig 1 control the probe will only become active when sig 1 is present. Signal 1 control overrides the no water inhibit.

PART 2 ROUTINE MAINTENANCE Always isolate Seko equipment from any electrical supply or external machine which supplies electrical signals. This must be done prior to carrying out any mechanical or electrical installation, repair or maintenance. FAILURE TO DO SO MAY RESULT IN SPILLAGE OF CHEMICAL, DAMAGE TO EQUIPMENT OR PERSONAL INJURY WHEN HANDLING CHEMICAL APPROPRIATE PPE MUST BE WORN AND MANUFACTURERS HANDLING PROCEDURES FOLLOWED Tube Changing The peristaltic tubing will require replacing periodically, dependant on use. To replace the pump tube first ensure the roller assembly is in the vertical position. This can be adjusted using the relevant prime button. Once the roller assembley is in the correct position the suction and discharge lines can be disconnected from the pump tube. NB Care should be taken to avoid chemical spillage. Remove the two screws at the top of the pump face, to release the top part of the pump head The tubing can now be accessed and removed from the bottom part of the pump head. Only Seko specified tubing should be used. Failure to do so may invalidate the warranty. Replace the pump face cover by pressing down the top of the pump face on to the pump tube, securing the pump tube between the roller edges. The bottom part of the pump face can then be clipped in to place on the bottom to the bottom part of the pump head. NB Ensure the clip on the bottom bracket is located inside the top half before clipping in to place Please ensure the tubing is during this operation. This can be tested by using the relevant prime button. Probe Cleaning If you are using the DR.30 in probe mode it is important to clean the probe electrodes and remove any scaling on a weekly basis. The DR.30 will inform you if the probe does not work due to the electrodes not being cleaned.

PART 3 DR30 MAX SET UP GUIDE Under counter and hood type machine Home display screen With this screen displayed the user can prime either pump by pressing & holding the - or + buttons. To enter programming mode and to progress through the menu press the centre arrowed button. The unit is password protected, so the first screen will ask for a Pin Code. The standard number is 11, which can be entered by using the up + button. If overshooting reduce by using the - button. Press the arrow button to continue Press the - button to enter the set up menu & again to program the settings The next screen is used to select the Initial fill dosage of detergent. The options are, when the unit is powered up, recieves a signal from a fill solenoid, or by probe (if fitted). Use the + button to cycle through the options. If Power up is selected the next screen will move straight to the D Fill time screen. If sig 1 is selected the next screen will give either a Timed or Speed option. When the selection is made you can then enter the run time or ml/min.enter the value by using the + or - buttons. Once again advance by pressing the arrow button and the display will now show the detergent top up options. SIG 2 or cyclic (for cyclic options see flight /conveyor machine set up ) Pressing the arrow button the display will then show the top up time. adjust by using the + or - buttons & press the arrow to progress The Rinse control options are Sig 2,or Cyclic. (Cyclic is a specialist option and rarely used)press the arrow button and the the Rinse dose options will be displayed. Either Timed or Speed. For Speed options see flight /conveyor machines) Adjust the Rinse dose time by using the + or - buttons and the arrow to move to the next screen. You are now given the option to Quit by pressing the - Button. The programming is now complete and the display will return to the OK Prime screen

FLIGHT OR CONVEYOR TYPE MACHINE SET UP For flight or conveyor machines the programming is similar to the previous set up procedure. The initial fill of Detergent can still be dosed via Power up or Timed (for probe option, see Probe set up). However for the Top up dose the Cyclic option should be selected. Pressing the arrow button the following display will be shown. This gives the option of dosing up to a maximum of 60ml every 180secs by use of the + & - buttons The Rinse control options are Sig 2,or Cyclic. (Cyclic is a specialist option and rarely used)press the arrow button and the the Rinse dose options will be displayed. Either Timed or Speed. For flight or conveyor machines the Speed option should be selected The amount of Rinse aid per minute can be selected by use of the + & - buttons NB As long as Sig 2 is present the Rinse pump will pulse and the Detergent pump will run on a cyclic basis. During this operation the Rinse dosage is given priority Pressing the arrow button You are now given the option to Quit by pressing the - Button. The programming is now complete and the display will return to the OK Prime screen

PROBE SET UP PROCEDURE Probe Mode can be used to dose Detergent on any type of machine To Dose using probe mode first scroll through the menu screens as before and select the Probe option on the D Fill display The next screen allows the input of a set point value. This is the conductivity value you would like to maintain The following display shows Sig 1 control and gives the option Yes or No by use of the + button. With Sig 1 control Yes selected the probe will only control the dosing whilst Sig 1 is present. With the No option selected the Probe will be in constant control and will dose accordingly Moving on you can also select the size of tank to be dosed. This will affect the reaction time of the alarms if no changes to conductivity levels are seen The following screens will display the Rinse options as before and the appropriate selctions can be made In Probe mode there are 2 alarm displays. NO WATER. When this screen is displayed the probe has been unable to read a conductivity reading as if there was no water present CLEAN PROBE. When this screen is displayed the probe has detected no change to the conductivity reading despite receiving a number of Sig 2 (Top up) signals STATISTICS MENU The DR30 Unit has a number of useful staistical menus available. To view these menus press the + button (Data) when the following screen is displayed. To scroll through the displays press the arrow button. If you wish to reset these figures at any time press and hold the + & - buttons when the RESET DATA LOG display is shown.

www.sekouk.com Unit 2 & 3 Coldharbour Pinnacles Ind Estate Coldharbour Road Harlow Essex CM19 5JH Tel: +44 (0)1279 423 550 Fax: +44 (0)1279 423 993 Email: sales@sekouk.com