Pressurisation units & expansion vessels

Similar documents
AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

ferroli Boiler Replacement Maxima 35C- Modena HE

ECONOBOOST EB II & EB III Compact Water Booster

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

MAXI & MAXI PLUS Floor mounted Pressure manager TECHNICAL DOCUMENTATION. Issue 06/14

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Extended Range. PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS.

Amptec. Electric flow boiler

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Installation, operating and servicing instructions

CRU-S Series Stainless Steel Condensate Recovery Unit

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Baxi Maxflow Combi WM

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

ADVANCE ECB ELECTRIC COMBINATION BOILER

Stored Water District Heating Interface Units. Heat Interface Units

Installation and Wiring Instructions

FCHM Hydromatic Pump Control Module

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

marine horticulture recycling

IMPRESS AND IMPRESS ADVANCED PRESSURISATION SETS INSTALLATION AND OPERATING INSTRUCTIONS

Broag Pressurisation equipment

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

Sirius FS. Working towards a cleaner future

Baxi Maxflow Combi FS

NON-SUBMERSIBLE WATER PUMP

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Alpha FlowSmart 25 and 50

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2

S-AF Floor Standing Condensing Boiler kW

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

LZT High efficiency air to water heat pumps with E.V.I. compressors

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Multi-Elec COMPACTE BOILER

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

DCS-100. intelligent damper control & monitoring system

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Fill Point, Level Gauges, and Control Range

INSTALLATION & TECHNICAL MANUAL

Water Chiller Solutions. A solution to every water cooling need.

SECTION STEAM CONDENSATE PUMPS

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Thermostatic Concealed Shower Valve

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Across-the-Line SERIES MP300 Combined Manual and Automatic

Hazardous Area Portable Fan Heater The Bulldog

.2 Section Waste Management and Disposal.

THERMOSTATIC SHOWER VALVE

Installation and User Instructions HS10U, HS15U.

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Variable Frequency Drive SERIES MP800 VFD

LZA High efficiency air to water heat pumps with HP compressor

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Installation and Servicing Instructions. Alpha FlowSmart

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Instructions for Use Installation and Servicing

Installation & User Instructions

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

CRU 200 and 500 Series Condensate Recovery Units

Easyfire Standalone biomass pellet boiler

Alpha CombiMax 350 and 600

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Hazardous Area Portable Fan Heater The Bulldog

DEKO 190 Ward washer-disinfector

Trade Product List 2013 BIOMASS ACCESSORIES

Hazardous Area Portable Fan Heater The Bulldog

Soft Start Series MP700 Solid State, Reduced Voltage

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Installation and Commissioning Manual

Transcription:

Pressurisation units & expansion vessels

Pressurisation units The new generation of microprocessor controlled pressurisation units Standard Unit/Advanced Unit These microprocessor controlled pressurisation units are suitable for use in a wide range of residential, commercial and industrial applications, where pressurisation of a heating or chilled water system is required. The new units incorporate CH2-30 and CH2-50 multi-stage centrifugal compact horizontal pumps that provide cold fill pressure up to 2.5 bar and 4.3 bar respectively. These low noise, efficient pumps are specifically developed for applications such as pressurisation. Available in single and twin pump configurations and in single phase as standard, both offer a comprehensive range of features. Features Standard Advanced Microprocessor Control Digital 2 Line Liquid Crystal Display Display Backlight Dual Colour Status LED Audible Alarm Alarm Mute 3-button User Interface Customer Assigned Password Protection Single or Twin Pump Versions Manual Pump Run Control Low Tank Water Level Multiple Programmable Alarms Service Due Feature Programmable Volt Free Contact(s) 1 2* History Event Log Automatic Pump-Test Pump Run Hours Counter Real Time Clock with Battery Back-Up Additional Thermal and Circuit Protection 240v AC 50Hz Single Phase Operation RS-232 Port *In addition to the above, Advanced offers eight (8) additional volt free contacts specifically for BMS (Building Management System) These can be used for: Pressure Low, Pressure High, Water Low, System Leak Pump A Fault, Pump B Fault, Service Due, System Fault 2 CALL 08707 272 755 VISIT www.ferroli.co.uk

Product Specification & Pump Data Pump Electrical Data Type Pump Phase Input FLC Start Type Power (P1)W (A) (A) Standard CH2-30 1ph 480 2.3 10.5 Advanced CH2-50 1ph 680 2.9 10.5 Voltage: 220-240V/1ph/50Hz Capacitor size: 10uF/400V Enclosure class: IP54 Insulation class: F Pump Material Specification Suction Chamber: Cast Iron BS 1452 Grade 180 Intermediate Chamber: Stainless Steel BS 1449 304 S15 Impellers: Stainless Steel BS 1449 304 S15 Pump Shaft: Stainless Steel BS 970 431 S29 Shaft Seal Face: Silicon carbide Shaft Seal Seat: Silicon carbide Shaft Seal O Rings: FKM elastomer Product Specification Microprocessor controlled 7 bar pressure transducer 240v/1ph/50Hz Digital pressure display with 0.1 bar resolution CE marked Dimensions Standard 750(H) x 450(W) x 330(D)mm Advanced 750(H) x 450(W) x 485(D)mm Pump Mechanical Data Liquid temperature: 0-90 C Max ambient temperature: 55 C Pump speed: 2900 rpm Connections Mains supply cable length: 4m Cold water supply connection: 1 2 BSP Male Overflow connection: 3 4 BSP Male System water connection: 15mm compression Weights Standard Advanced 1 x CH2-30: 25 kg 29 kg 1 x CH2-50: 28 kg 32 kg 2 x CH2-30: 35 kg 42 kg 2 x CH2-50: 40 kg 47 kg Product Codes Standard Standard Standard Standard 1 Pump 1 Pump 2 Pump 2 Pump CH2-30 CH2-50 CH2-30 CH2-50 MIMS 2301 MIMS 2501 DIMS 2301 DIMS 2501 Advanced Advanced Advanced Advanced 1 Pump 1 Pump 2 Pump 2 Pump CH2-30 CH2-50 CH2-30 CH2-50 MIMA 2301 MIMA 2501 DIMA 2301 DIMA 2501 CALL 08707 272 755 VISIT www.ferroli.co.uk 3

Standard unit Advanced unit Microprocessor control 450 330 160 70 55 Microprocessor control 450 485 160 70 55 165 165 750 Overflow Mains water in 15mm dia discharge 750 Overflow Mains water in 15mm dia discharge 250 Access to volt free contacts 250 245 245 All dimensions are in mm All dimensions are in mm Operation of volt free contact(s), audible alarm and LED indicator (when being used as a stand alone unit). The new range of standard and advanced microprocessor controlled pressurisation units has the option of configuring the operation of the volt free contacts, the audible alarm and the dual colour LED indicator. Each of the above three functions can be assigned to operate with one or more of the following configurable parameters: Optional features Low Pressure, High Pressure, Low Water Level, System Leak, Pump Fault, Service Due, Controller Fault, Stop Relay Failsafe Operation. The standard unit is provided with one programmable volt free contact. The standard unit would be specified where only system interlock or a fault indication is required. The advanced unit is provided with two programmable volt free contacts. The above parameters can be assigned to the operation of one or either volt free contact as required. The advanced unit would be specified where both a system interlock and a fault indication is required. There are also an additional eight dedicated volt free contacts specifically to communicate with building management systems. In addition to both of the units, provisions have been made for customised features such as: Network communications Connection to remote control display panel for adjustment and monitoring Stainless steel CHN units or other pump alternatives for high pressure systems These options can be discussed with our Sales Team on 08707 272 755 4 CALL 08707 272 755 VISIT www.ferroli.co.uk

Expansion vessels Systems with pressurisation sets require the installation of an expansion vessel of adequate capacity. This table gives guide figures for the number and size of expansion vessels required. Please contact us for details of our complete product range and dimensions. Installed boiler System volume Vessel volume No. and size power (kw) (litres) (litres) of vessel(s) min max min max 28 70 280 700 60 1 x 60 71 93 701 930 80 1 x 80 94 115 931 1150 100 1 x 100 116 230 1151 2300 200 1 x 200 231 345 2301 3450 300 1 x 300 346 465 3451 4650 400 2 x 200 466 580 4651 5800 500 1 x 500 581 700 5801 7000 600 2 x 300 701 810 7001 8100 700 1 x 700 810 1160 8100 11600 1000 1 x 1000 1161 1620 11601 16200 1400 1 x 700 1620 2330 16200 23300 2000 1 x 1000 CALL 08707 272 755 VISIT www.ferroli.co.uk 5

Mini pressurisation units The Mini Pressurisation Unit is a compact wall mounted unit housing either one or two small pressurisation pumps and associated control equipment for connecting to small heating or cooling installations within large domestic dwellings or small industrial/commercial installations. All the equipment is mounted in a white powder coated casing with a flush mounted gauge on the front of the unit to indicate the system pressure. Within the cabinet is housed a small make-up tank complete with a system filling valve assembly complying with the Water Regulations Guide, a small hydraulic pump capable of producing a pressure of between 0.7 to 2.4bar, pressure control switch, control circuit fuse, terminals, and all necessary wiring to achieve the correct operation. Suitable connections are provided to allow system make-up, tank overflow, and connection to the system pipework as well as electrical terminals for connecting the single phase, live, neutral and earth supply. Installation The mechanical and electrical installation of the unit should be carried out in accordance with the relevant Water Authority Regulation and current edition of the Electrical Regulations. Essential requirements 1. Locate units in a well ventilated environment. 2. Ensure supply voltage and overload protection is correct. 3. An isolating valve should be fitted to the incoming water supply. 4. Electrical installation should be carried out by a competent electrical engineer. Covers and guards should not be removed during operation or without isolating the unit first. Note: An anti-gravity loop with a minimum height of 2m (or an intermediate vessel) must be installed to provide thermal protection to the unit. No pipework lagging is required between the system and the expansion vessel(s). The unit should be wall mounted, ensuring sufficient clearance is left to allow the cover to be removed. The pipework to the expansion vessels should be sized according to the size and number of vessels and should be at least the same as the tank connection. Any expansion vessels should be fitted with individual drain cocks and isolating valves to facilitate initial set-up and future maintenance. The system should be initially filled via a quick fill loop before operating the unit. The pump is not capable of filling any size of system. 6 CALL 08707 272 755 VISIT www.ferroli.co.uk

20 310 30 300 Outline of cabinet 200 Wall mounting is by 3 screw keyholes on rear of unit View showing the mounting hole pattern 52 Mains cable gland 1 4 BSP female system connection 1 2 BSP male water inlet 3 4 overflow connection 200 350 All dimensions shown in mm Electrical connections The unit should be connected to 240V single phase supply. The unit is internally fused with a 2A fuse. Customer connections Customer connections are accessed from the bottom of the unit. All connections are on 52mm centres from the rear face of the unit. See diagram above. Adjustment of control pressure switch The control pressure switch is factory set for 1 bar. In the unlikely event that this pressure is not acceptable and has to be adjusted within the operating range of the pump, ie maximum 2.4 bar, the following procedure should be adopted: isolate the unit and remove cover screws and cover to access the pressure switch. The pressure setting can then be adjusted by turning the knurled knob on the pressure switch to the desired value, using the pressure gauge as a guide. Technical data Pump unit Self-priming piston pump, type 508LA, max. flow 80 litres/hour, generated pressure 2.4 Bar. Pump connection 1 8. Nominal power consumption 25W. Make up tank 4.5 litre capacity. Complies with WRC byelaw 11 regulation. System connection 1 4 BSPF, water inlet connection 1 2 BSPM, overflow connection 3 4. Pressure switch Type 100SS, adjustment range 0.7 bar to 6.0 bar, 15amp @ 250v AC. Overpressure 10 bar (note that pump maximum pressure is 2.4 bar). Pressure gauge 50mm diameter scaled 0.6 bar (dual scale). Weights and dimensions Weight 8.5kg empty. Dimensions 350(H) x 300(W) x 200(D)mm. CALL 08707 272 755 VISIT www.ferroli.co.uk 7

Ferroli Limited Ferroli began producing heating appliances and equipment in Italy during the 1950s. Today, the company is still family-owned but now operates ten ultra-modern factories in Europe, employing over 2,500 people and producing a wide range of wall hung, cast iron and welded steel boilers, making Ferroli one of the largest and most successful heating appliance manufacturers in the world. Ferroli Commercial and Industrial Boilers The commercial and industrial boiler range covers steel and cast iron designs, atmospheric and pressure jet units, and oil, gas or biomass models. Outputs range from 50kW to 14,000kW. Other products include heat exchangers and pressurisation units. Ferroli s UK warehouse, backed by its huge manufacturing facility in Italy, offers delivery ex-stock for most smaller boiler models and for all frequently used parts. It also assembles sectional boilers in the UK to suit particular requirements. Ferroli Domestic Boilers Offering gas wall mounted units with outputs from 5kW to 50kW, Ferroli s stylish, compact domestic boilers provide maximum comfort with minimal fuel usage. With a choice of conventional, condensing and combi technologies, there s a boiler to match the heating and hot water requirements of every home. Ferroli Service Once the normal guarantee period on our boilers has expired, coverage can be extended cost-effectively with a choice of Ferroli service contracts to suit your budget. All Ferroli service engineers work to Benchmark standards and the Benchmark Code of Practice for the installation, commissioning and servicing of central heating systems, designed to improve the quality of work undertaken by plumbers and heating installers. Ferroli Spares The rapidly growing popularity of Ferroli as first choice for both domestic and commercial installations means that heating parts stockists offer readily available spares for Ferroli boilers. For less frequently needed items, we maintain a fully-stocked warehouse located centrally in the UK, enabling same-day despatch of just about any part needed to keep your Ferroli boiler running at optimum efficiency. Ferroli Training Ferroli understands that well-trained installers are the key to a safe and efficient heating system. That s why we run comprehensive training courses in our purpose-built facilities for everyone concerned in the installation and servicing of Ferroli s range of boilers. These courses improve installers knowledge and skills by providing both the theory and the hands-on practical experience essential to maintaining heating system performance and safety. Ferroli Ltd Lichfield Road Branston Industrial Estate Burton-Upon-Trent Staffordshire DE14 3HD tel 08707 272 755 fax 08707 272 766 e-mail: commercial@ferroli.co.uk www.ferroli.co.uk SA-COC-1487 All the information in this brochure was correct at the time of printing, specifications and designs may be changed owing to Ferroli s policy of continuous product research and development. The statutory rights of the consumer are not affected. December 2007 / Issue 2