INTERNATIONAL JOURNAL OF CONSERVATION SCIENCE

Similar documents
Figure 1: Mini One and display case connections

LOW ENERGY CLIMATE CONTROL FOR MUSEUM STORES

Improving the (museum) indoor climate in a flooded castle

EFFECTIVENESS OF ENTOMOLOGICAL COLLECTION STORAGE CABINETS IN MAINTAINING STABLE RELATIVE HUMIDITY AND TEMPERATURE IN A HISTORIC MUSEUM BUILDING

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

Modelling impact of collections on indoor climate and energy consumption in libraries and archives

Victoria & Albert Museum, London Medieval & Renaissance Galleries: A Passive Approach to Humidity Control

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Prediction of Soil Infiltration Rate Based on Sand Content of Soil

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Optimisation of cooling coil performance during operation stage for improved humidity control

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

ACHEIVING COMFORT IN SUBTROPICAL CLIMATES: BUILDING A MICROCLIMATE IN THE GUANGZHOU SCIENCE MUSEUM

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Available online Journal of Scientific and Engineering Research, 2017, 4(10): Research Article

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

PASSIVE HYGROTHERMAL CONTROL OF A MUSEUM STORAGE BUILDING. Jørgen Erik Christensen 1 and Hans Janssen 2

,Chaojian He6, f. School of Guangxi University, Nanning , China.

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

1.1. SCOPE OF THE WORK:

FEEDGAS FOR MODERN HIGH-PERFORMANCE OZONE GENERATORS. Bruce T. Stanley. Ozonia Ltd Duebendorf, Switzerland 1999

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Temperature and Relative Humidity agents of deterioration. 22 September 2015 Mikkel Scharff Sarah Staniforth

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Characterization of a hygro-regulated Wall Base Ventilation System for Treatment of Rising Damp in Historical Buildings

LOW ENERGY AIR CONDITIONING OF ARCHIVES

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

The Experimental Research on Grain Storage Heat and Moisture Transfer Siyu Chen 1,2, Wenfu Wu 1,Yan Xu 1,Chunshan Liu 2, Yaqiu Zhang 1, a

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

INTRODUCTION OF HYBRID VENTILATION SYSTEMS OF DWELLING BUILDINGS IN LATVIA

PRESSURE RELATIONSHIPS IN HOSPITAL CRITICAL-CARE FACILITIES

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Energy efficient climate control in museum stores. Poul Klenz Larsen

THE AMOUNT OF ACCUMULATED DUST IN DUCTS OF NEW HVAC INSTALLATIONS

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

Efficiency of Non-Azeotropic Refrigerant Cycle

Next Generation Passivhaus Archives

CASE STUDY REGARDING ENERGY EFFICIENCY OF A VENTILATION SYSTEM WITH RECUPERATIVE HEAT RECOVERY

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

THE EFFECT OF HEAT LOAD ARRANGEMENT ON THE PERFORMANCE OF RADIANT PANELS

A study of Transient Performance of A Cascade Heat Pump System

Microclimate Control in Museums

Heat pump supplemental heating system for motor vehicles

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

HUMIDITY CONTROL IN A BASEMENT ART VAULT

The Current (2017) State of the Art for Air Leakage in Ductwork

Performance of an Improved Household Refrigerator/Freezer

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Home appliances simulator for smart home systems testing

K.F. Fong *, C.K. Lee, T.T. Chow

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Thermal and air quality effects on the performance of schoolwork by children

Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

Museum indoor climate and energy use. Henk Schellen Rick Kramer

Field Study of Diffuse Ceiling Ventilation Performance in a Landscape Office

Home Performance Science

INFLUENCE OF DIFFERENT TEMPERING PERIOD AND VACUUM CONDITIONS ON THE RICE GRAIN BREAKAGE IN A THIN LAYER DRYER

HYGROTHERMAL PERFORMANCE BENEFITS OF THE CELLULOSE FIBRE THERMAL INSULATION STRUCTURES

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimental Research on Monomial Cooling Measure of Greenhouse in Summer

Adsorption refrigeration system using waste heat

INDIRECT EVAPORATIVE COOLING A PAST REVIEW

Corn drying experiments by pilot dryer

Stability & Shelf Life

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

AN EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THERMOSTAT SETTINGS ON THE ENERGY CONSUMPTION OF HOUSEHOLD REFRIGERATORS

A Study on Suction-rainfall Response of a Cut Slope in Unsaturated Residual Soil Using a Field Rain Simulator

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

Optimizing Electric Humidifier Operation with an Air Side Economizer

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

OPERATION INSTRUCTION

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

HICOSYS FOR PROCESS CONTROL OF SPRAY DRYERS

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

Thermal Comfort with Convective and Radiant Cooling Systems

Transcription:

ISSN: 2067-533X INTERNATIONAL JOURNAL OF CONSERVATION SCIENCE Volume 8, Issue 1, January-March 2017: 43-50 www.ijcs.uaic.ro TEST OF A DEVICE FOR THE ACTIVE CONTROL OF ENVIRONMENTAL HUMIDITY IN MUSEUM DISPLAY CASES Giacomo GOLI 1*, Linda COCCHI 1, Marco TOGNI 1, Marco FIORAVANTI 1 1 GESAAF - University of Florence - Via S. Bonaventura, 13, 50145 Florence, Italy Abstract A series of laboratory tests were conducted on a commercial device for active relative humidity control of display cases to assess the ability of the machine to control a medium format (3.45 m3) museum display case. An extreme museum environment with large relative humidity and temperature fluctuations was simulated and different air leakage rates were produced (0.1-0.5-6 AER/day) on a purposely-made display case. The machine was shown to work very effectively for both in humidify and dehumidifying for conditions corresponding to very well sealed ( AER 0.1) to medium sealed (AER 0.5). On a very poorly sealed enclosure (AER 6), the external environmental fluctuation resulted in internal fluctuations but the machine very effectively mitigated these effects. The use of the machine in positive pressure mode and (optional) recirculating mode was shown to be irrelevant to the ability of the machine to control the relative humidity. Positive pressure mode provides a constant flow to remove VOC's from the showcase (which could contribute to artefact degradation.), and to prevent ingress of ambient pollutants. Keywords: Museum; Showcase; Climate; Active conditioning; Microclimate; Relative humidity Introduction Appropriate climate control within museums and heritage buildings is still a major unsolved problem in heritage conservation. This is well documented in a large number of papers. Two reports making the point on the matter have recently been published by [1] and [2]. Unfavourable environmental conditions inside buildings and museums have important consequences on the well-being of visitors and workers and climatic fluctuations have serious impact on structures and collections. The subject is so important that the ASHRAE - American Society of Heating, Refrigerating and Air-Conditioning Engineers - has released a specific handbook on the subject [3] where performance targets are given as well as the expected performance of various specifications options. On this subject, within the 7th Framework Program of the European research, a project named Climate for Culture (2009-2014 Grant Agreement no. 226973) was financed to analyse the effects of climate change on historical buildings and developed strategies for long-term preservation [4]. The main environmental parameters influencing the collections conservations were identified by [5] as to be: relative humidity, atmospheric pollution, noise and vibration, temperature, illumination. a) Relative humidity fluctuations produce changes in size and shape of the exhibits with associated stresses, change in the rate of deterioration because of chemical reactions, changes in biological deterioration sources. b) Atmospheric pollution can produce particulate deposition as well as * Corresponding author: giacomo.goli@unifi.it

G. GOLI et al. chemical degradation. c) Noise and vibrations can cause mechanical damages as well as the inconvenience of visitors. d) Temperature can result in accelerated chemical degradation or accelerated water adsorption/desorption. e) Illumination can accelerate chemical degradation, discolour, increase the temperature. The control of these parameters at building level is very complicate, energy demanding and expensive. A local approach to stabilize the immediate encased environment of the object to be conserved has been adopted by the development of display cases. On this specific field guidelines for the design of showcases for cultural heritage preservation were published as European standard EN 15999-1 in 2014 [6]. A new standard defining the characteristics and conditions for use of showcases is actually under definition as pren 15999-2 [7]. Also the procedures and the instruments to measure the relative humidity as well as the moisture exchanges between air and cultural property were defined in the European standard EN 16242 published in 2012 [8]. Display cases, if well made, give to cultural property a good protection against atmospheric pollution and relative humidity as well documented in [9-13]. In particular the protection against relative humidity fluctuations can be obtained both with passive and active systems and the evolution of these systems is well described in [14]. Different solutions for active relative humidity conditioning can be found today on the market working with different principles. Preservatech's Mini One is a device conceived to control the relative humidity of display cases from 35% to 80% for up to 10m 3 of volume. The machine operates by controlling the temperature of a water tank in contact with the air circulation system in order to attain the vapour pressure desired to get the correct relative humidity. The device can work in two modes: positive pressure mode and recirculating mode. In positive pressure mode intake air from outside the display case is pumped through the Mini One for conditioning and then injected into the display case at very low pressure. The result is a positive pressure inside the display case and a continuous air flow out through the leaks in the display case. In this configuration, the device is connected to the display case with only one pipe, and a single unit can be used to control relative humidity in multiple showcases. The interest of positive pressure mode is the prevention of the entrance of dust and other external pollutants and at the same time the expulsion of undesired Volatile Organic Compounds (VOC) that could produce further damage [15]. In recirculating mode the air is recirculated from inside the display case and reinjected after conditioning. In recirculating mode two pipes are needed (one input and one output) and neutral pressure is achieved inside the display case. The device needs to be powered for 24h. In case of power supply gap the unit will restart operating automatically to the same target set before the gap. Several tests were conducted on a medium volume showcase in order to analyse the ability of the device to control the relative humidity of a big display case under simulated extreme environmental conditions. Material and methods The test was conducted as a simulation of a museum environment with extreme fluctuations of temperature ( T) and relative humidity (RH). The room temperature was varied between the extremes of 12 and 24 C and the RH between the extremes of 30 and 90%. A medium volume display case 2.3m long, 1.5m deep and 1.0m tall was built for a total volume of 3.45m 3. This volume was chosen on the base of the most frequently requested to the device producer. For higher volumes a lower promptness of the device to control relative humidity should be expected while for lower volumes a higher promptness should be expected. The display case was made with gas barrier plastic film suspended to a wooden frame perfectly sealed in the junctions. Any kind of hygroscopic material was present inside the built display case. The pipes length was: 0.9 m from pump to Mini One and 2.0m from Mini One to display case for positive pressure configuration (see Fig. 1). In recirculating mode a pipe of 2.6m was added to connect the display case output to the pump input (the output was placed on the 44 INT J CONSERV SCI 8, 1, JAN-MAR 2017: 43-50

TEST OF A DEVICE FOR THE ACTIVE CONTROL OF RELATIVE HUMIDITY IN MUSEUM DISPLAY CASES opposite side of the input in order to allow an optimal air flow see Fig. 1). The Mini One regulation sensor was placed 10 cm from the display case conditioned air input. Supply pipe Return pipe T and RH logger Control RH probe Mini One Display case 2.3X1.5X1 = 3.45 m 3 Fig. 1. Mini One and display case connections Three different tightness configurations were tested in order to simulate different display cases: very good tightness, conventional tightness and very poor tightness. The different tightnesses were achieved by producing holes of different dimensions to the perfectly sealed box. The tightness was measured with the CO 2 method proposed [16]. The tightness is expressed in AER (Air Exchange Rate) per day, meaning that the number of times the air gets completely changed inside the display case during a day. The tightness was determined with the Mini One switched off because is to be considered as a property of the display case that would be altered by the air pump pressure. The three conditions tested were: Very good tightness AER/day 0.1 produced with two holes of 14mm of diameter; Conventional tightness AER/day 0.5 same holes as for AER 0.1 plus a rectangular hole of 106 mm by 80mm; Very poor tightness AER/day 6.1 same holes as for AER 0.5 plus a rectangular hole of 100mm by 200mm. The Mini One operation was tested at low (45%) and high (65%) relative humidity targets for very good tightness and conventional tightness conditions. The very bad tightness condition was tested at intermediate (55%) relative humidity target both in positive pressure and recirculating configurations. Independent data loggers produced by CEAM Control Equipment model C310 were used to acquire the display case internal and external (room) RH and T during the experiments. The accuracy of the sensors was ±3% for RH and ±0.3 C for T. The sensor logging the display case internal RH and T was placed in the centre of the display case while the sensor logging the exterior of the display case (RH and T of the room) was suspended in the proximity of the display case. Case characterization A reference test was conducted with Mini One off in order to check the effect of the room environmental fluctuations on the display case internal microclimate with an AER of 0.5. T was a wintertime daily heating simulation with a large variation between day and night. The internal T has shown to follow perfectly the external one highlighting a negligible influence of the case (see Fig. 2a). For RH external fluctuations going from +40 to -15% from the median of the whole period (see Fig. 2b), the display case interior gradually followed the room variations according to the time necessary to the diffusion to take place. These external fluctuations produced large display case internal variations going from +20 to -10% from the median of the whole period. This test is supposed to be a reference for comparison with the tests performed with Mini One switched on. http://www.ijcs.uaic.ro 45

G. GOLI et al. a Fig. 2. Behaviour of the temperature (a) and of the relative humidity (b) inside and outside the display case with Mini One switched off Effect of Mini One on the display case internal temperature In Fig. 3 are shown the display case and the room temperature with Mini One operating. The test was done with AER 0.5 and with an RH target of 45%. As can be observed the effect of Mini One on the temperature is negligible at conventional temperatures and becomes visible only at low temperature such as 12 C. This temperature cycle is typical of the other tests performed on the device and will not be shown for the following tests. b Results Fig. 3. Room and display case temperature with Mini One operating at AER 0.5 and 45% RH target. The influence of Mini One on the internal temperature is negligible Mini One operating in positive pressure mode with AER 0.1 Target 45% RH The display case relative humidity was largely kept inside the ±5% RH from the target with external fluctuations going from +40% to 20% RH (see Fig. 4). Similar conditions with Mini One off resulted in an internal overall fluctuations of 30% RH. 46 INT J CONSERV SCI 8, 1, JAN-MAR 2017: 43-50

TEST OF A DEVICE FOR THE ACTIVE CONTROL OF RELATIVE HUMIDITY IN MUSEUM DISPLAY CASES Fig. 4. Deviation of the display case relative humidity from the 45% RH target in a fluctuating external environment. Mini One operating in positive pressure mode with an AER of 0.1. The variation inside the green box are within ±5% RH from the target. Target 65% RH The display case relative humidity was largely kept inside the ±5% RH from the target with external fluctuations going from +30% to 25% RH (see Fig. 5). Similar conditions with Mini One off resulted in an internal overall fluctuations of 30% RH. Fig. 5. Deviation of the display case relative humidity from the 65% RH target in a fluctuating external environment. Mini One operating in positive pressure mode with an AER of 0.1. The variation inside the green box are within ±5% RH from the target Mini One operating in positive pressure mode with AER 0.5 Target 45% RH The display case relative humidity was largely kept inside the ±5% RH from the target with external fluctuations going from +25% to 20% RH (see Fig. 6). Similar conditions with Mini One off resulted in an internal overall fluctuations of 30% RH. http://www.ijcs.uaic.ro 47

G. GOLI et al. Fig. 6. Deviation of the display case relative humidity from the 45% RH target in a fluctuating external environment. Mini One operating in positive pressure mode with an AER of 0.5. The variation inside the green box are within ±5% RH from the target Target 65% RH The display case relative humidity was largely kept inside the ±5% RH from the target with external fluctuations going from +25% to 35% RH (see Fig. 7). Similar conditions with Mini One off resulted in an internal overall fluctuations of 30% RH. Fig. 7. Deviation of the display case relative humidity from the 65% RH target in a fluctuating external environment. Mini One operating in positive pressure mode with an AER of 0.5. The variation inside the green box are within ±5% RH from the target Test with MiniOne operating in positive pressure and recirculating mode with AER 6 and an RH target of 55% Mini One has shown to produce large attenuation of the RH variations at AER 6 both in positive pressure than recirculating mode (see Fig. 8). The display case RH with AER 6 and Mini One operating is more stable than with Mini One switched off and AER 0.5 as reported in Fig. 2. In particular is to be noted a very good attitude to hold RH very close to target value even with much lower external humidity. It should be also noted that an RH spike of +50% in a few hours is a very extreme case adopted in order to verify the difference between positive pressure mode and recirculating modes. As can be observed not relevant differences can be reported between the two working principles. 48 INT J CONSERV SCI 8, 1, JAN-MAR 2017: 43-50

TEST OF A DEVICE FOR THE ACTIVE CONTROL OF RELATIVE HUMIDITY IN MUSEUM DISPLAY CASES a b Fig. 8. Deviation of the display case relative humidity from the 55% RH target in a fluctuating external environment. Mini One operating in positive pressure mode (a) and in recirculating mode (b) with an AER of 6. The variation inside the green box are within ±5 % RH from the target In order to have a better highlight of the efficiency of positive pressure and recirculating modes the time necessary to perform a humidity step was recorded with a very critical condition as with AER 6. The principle is that the more effective method would result in a more rapid step completion. A +20 RH step (going from 45 to 65%) and a -20 RH step (going from 65% to 45%) were executed with positive pressure and recirculating configurations and the results are reported in Table 1. As can be observed, the difference between the two configurations is very small and they can be considered equivalent. The machine clearly shows a better ability to humidify than to dehumidify. Conclusions Table 1. Time necessary to Mini One to complete a humidifying step going from 45 to 65% RH and a dehumidifying step going from 65 to 45% RH in positive pressure mode and recirculating mode Operation Step Mode Time [h:mm] 45 to 65% RH Positive pressure 2:24 65 to 45% RH Positive pressure 3:20 45 to 65% RH Recirculating 2:53 65 to 45% RH Recirculating 3:20 Mini One unit has shown to behave very effectively for the relative humidity control of a large display case of 3.45 m 3. The device has shown to not affect the temperature of the showcase. With AER 0.1, corresponding to a state of the art display case tightness, the machine has performed very well both at low humidity (45%) than high humidity (65%) targets. The display case interior was largely kept within 5% from the targets with very severe room conditions. The same is to be said for an AER of 0.5 corresponding to a conventional tightness. The unit has shown to give a strong support to reduce relative humidity spikes even with very poor tightness conditions such as AER 6 (corresponding to big holes on the display case). Positive pressure mode and recirculating mode have not shown relevant differences for conditioning capacity or accuracy. Working with relative humidity steps has shown a very similar behaviour for both positive pressure and recirculating modes. A better ability of the unit to humidify than to dehumidify was also recorded, which is in line with the specifications sheet. The positive pressure mode is more interesting than the recirculating one because the positive http://www.ijcs.uaic.ro 49

G. GOLI et al. pressure prevents the entrance of dust and other external pollutants, as well as expelling undesired Volatile Organic Compounds emitted by the objects. References [1] A. Luciani, Historical climates and conservation environments. Historical perspectives on climate control strategies within museums and heritage buildings, PhD Thesis, Politecnico di Milano, 2013. [2] S. Michalski, Climate Guidelines for Heritage Collections : Where We Are in 2014 and How We Got Here, Proceedings of the Smithsonian Institution. Summit on the Museum Preservation Environment, 13th-14th March 3013, Washington, D.C., USA, pp. 7-33. [3] * * *, ASHRAE Handbook, HVAC Applications, Chapter 23, Museums, Galleries, Archives, and Libraries, ASHRAE, Atlanta, USA, 2015. [4] * * *, Climate for Culture, http://www.climateforculture.eu/ [accessed on February 10, 2016]. [5] G. Pavlogeorgatos, Environmental parameters in museums, Building and Environment, 38 2003, pp. 1457-1462. [6] * * *, Conservation of cultural heritage - Guidelines for design of showcases for exhibition and preservation of objects - Part 1: General requirements, EN 15999-1, 2014, [7] * * *, Characteristics and conditions for use of showcases for the exhibition of cultural heritage, reducing environmental interaction, complying with the requirements for better preservation to reduce risks factors climate variability, light, pollution - for conservation, improve visibility and ensure safety and security, pren 15999-2(EN 15999-1), National Mirror Committee of CEN/TC 346/WG 12, 2014. [8] * * *, Conservation of cultural heritage - Procedures and instruments for measuring humidity in the air and moisture exchanges between air and cultural property, EN 16242, 2012. [9] I. Sandu, V. Vasilache, I.C.A. Sandu, M. Hayashi, A New Method of Determining the Normal Range of Hydric-Equilibrium Variation in Wood, with Multiple Applications, Revista de Chimie, 61(12), 2010, pp. 1212-1218. [10] B. Barrette, Climate control, active and passive,the Egyptian Galleries at the Metropolitan Museum of Art, Museum, 146 (Show-Cases, Vol XXXVII, n 2, 1985), 1985, pp. 81-84. [11] S. Michalski, A relative humidity control module, Museum, 146 ( Show-Cases, Vol XXXVII, n 2, 1985), 1985, pp. 85-88. [12] T. Padfield, A cooleddisplay case, Museum, 146 (Show-Cases, Vol XXXVII, n 2, 1985), 1985, pp. 102-103. [13] M. Cassar, Case design and climate confrol: A typological analysis, Museum, 146 (Show- Cases, Vol XXXVII, n 2, 1985), 1985, pp. 103-107. [14] J. Shiner, Trends in microclimate control of museum display cases, Proceedings of Museum Microclimates, 19 th -23 rd November 2007, Copenhagen, Denmark, 2007, pp. 267 275. [15] J. Tétreault, Airborne Pollutants in Museums, Galleries, and Archives: Risk Assessment, Control Strategies, and Preservation Management, Canadian Conservation Institute, 2003. [16] A. Calver, A. Holbrook, D. Thickett, S. Weintraub, Simple methods to measure air exchange rates and detect leaks in display and storage enclosures, Proceedings of the 14 th Triennial Meeting, 12 th -16th September 2005, The Hague, Netherlands, 2005, pp. 597 609. Received: May, 24, 2016 Accepted: February, 15, 2017 50 INT J CONSERV SCI 8, 1, JAN-MAR 2017: 43-50