AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

Similar documents
CENTRIFUGAL FANS user's manual. model VENTS VK.

INTELLIGENT AXIAL FAN user's manual

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

AXIAL FANS USER S MANUAL

Wind. Service instruction

AXIAL FANS user's manual. model Quiet

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Aero. Service Instructions

Calm. Service Instructions

Turbo. Service Instructions

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Axial intelligent fan USER S MANUAL

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL. VKP Series INLINE FAN

Centrifugal inline fans

HEAT RECOVERY AIR HANDLING UNIT

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

Air handling unit. BlauAir RH USER S MANUAL

USER S MANUAL DN-2. Drain pump

White - Non Illuminated Art no White - Cool White LED Art no.32600

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

HEAT RECOVERY VENTILATOR

USER'S MANUAL PS

Turbo Inline Fan, White - Non Illuminated Art no.33500

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

AIR HANDLING UNIT WITH HEAT RECOVERY

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

Centrif Duo & Centrif Duo Plus

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Lo-Carbon Quadra Centrifugal Fan

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

G Installation manual Solitude - dmev unit

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

Whole Room Dryer WRD, WRD/110

30-pint Dehumidifier User Guide

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

SAVE THESE INSTRUCTIONS

Classic Electric Stove

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

WCD-200W Water Dispenser

USE AND INSTALLATION HANDBOOK

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

PH1000T PH1500T PH2000T

EVG Extractors. Manual for Installation, Use and Maintenance

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Remote Tower Fan USER INSTRUCTIONS. Product Code: MY146. IMPORTANT Installers and Users please note:

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

HEAT RECOVERY AIR HANDLING UNITS

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

Lo-Carbon Quadra SELV

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

De Longhi Rangehood USER GUIDE. Model TA60SS (60cm) / TA90SS (90cm) Please read this user guide carefully and retain for future reference 08.

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

General safety precautions English

Cooker Hood LA-72-CAN.

EN... P. 1 7 FR... P ES... P SAVOY TOASTER 2 slices / 4 slices KH31. i h. NC

USER S MANUAL UET CONTROL UNIT FOR THE AIR HEATING UNIT WITH ELECTRIC HEATER AOE SERIES

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Manual for Ceiling Patio Heater

USER MANUAL AND INSTALLATION MAKNA EEC. CV

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

FLCH4R Garage and Utility Electric Heater

Lucci Designer Hi Flow Exhaust Fan

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Lo-Carbon SELV Tempra

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

Transcription:

AXIAL DOMESTIC FANS User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

SAFETY REQUIREMENTS Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. The single-phase power mains must comply with the acting local electrical norms and standards. The fixed electrical wiring must e equipped with an automatic circuit reaker. The fan must e connected to power mains through an automatic circuit reaker QF integrated into the fixed wiring system with the gap etween the reaker contacts on all poles not less than 3 mm. Check the fan for any visile damages of the impeller and the casing efore starting installation. The casing internals must e free of any foreign ojects which can damage the impeller lades. Misuse of the device or any unauthorized modification is not allowed. The fan is not to e used y children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation y the person(s) responsile for their safety. Do not leave children unattended and do not let them play with the product. Take steps to prevent ingress of smoke, caron monoxide and other comustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must e provided for proper comustion and exhaust of gases through the chimney of fuel urning equipment to prevent ack drafting. Transported medium must not contain any dust or other solid impurities, sticky sustances or firous materials. Do not use the fan in the environment containing hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or lock the fan intake or extract vents in order to ensure the most effective air passage. Do not sit on the fan and do not put ojects on it. Fulfill the requirements stated in this user's manual to ensure long service life of the product. Recycle at the end of the service life. Do not dispose the product with unsorted municipal trash. 1

USE The product descried herein is an axial fan for exhaust ventilation of small and medium-sized premises heated during cold seasons. These fans are designed for wall or ceiling mounting. The FENESO serie is designed for window mounting. Casals fans are designed for continuous operation always connected to power mains. MAIN TECHNICAL DATA The fan is rated for connection to AC 220-240 V, 50 Hz power mains. The fan requires no grounding. Ingress protection rating against access to hazardous parts and water ingress: IP24: LIBELLA, FENESO, CYCNUS series. IP34: LARUS, CICONUS, SIGILA, SIGILA MOTION series. The rated air capacity of the transported air volume: for the fans with Ø100mm exhaust spigot diameter - 55-107 m3/h (± 5 %); for the fans with Ø125mm exhaust spigot diameter - 108-232 m3/h (± 5 %); for the fans with Ø150mm exhaust spigot diameter - 220-348 m3/h (± 5 %). Rated fan power: 5.3/22 W for the fans with Ø100mm exhaust spigot diameter; 9.1/26 W for the fans with Ø125mm exhaust spigot diameter; 20/32 W for the fans with Ø150mm exhaust spigot diameter. Noise level at 3 m distance does not exceed 40 db(a). Due to constant improvements the design of some models may slightly differ from those ones descried in this manual. The fan is rated for operation at the amient temperature ranging from +1 C up to +45 C. The fan designation, layout outer view, overall and connection dimensions and design features are stated in fig. 1. The fan service life is not less than 5 years. 2

LIBELLA 100 LIBELLA 125 LIBELLA 150 a D ñ å Type LIBELLA 100 LIBELLA 125 LIBELLA 150 à 165 190 212 150 173 195 c D e 92 100 30 98 114 125 150 30 30 FENESO 125 FENESO 150 a e c D Type FENESO 125 FENESO 150 à 190 190 173 173 e c D g h 53 58 125 53 125 123 159 h g tale 1 3

CICONUS T 100 a c Type à CICONUS T 100 152 120 c D e 126/111 100 30 D e CYCNUS 100 a c Type à CYCNUS 100 150 122 c D e 125 98 36 D e LARUS 100 LARUS 125 LARUS 150 a D c Type LARUS 100 LARUS 125 LARUS 150 à 150 176 205 c D e 120 140 108/93 114/96 100 125 12 13 165 132 150 14 e 4 tale 1

SIGILA MOTION 100 SIGILA MOTION 125 SIGILA MOTION 150 Type SIGILA MOTION 100 SIGILA MOTION 125 SIGILA MOTION 150 à 159 180 206 135 150 182 c D e 88.5 100 23 94 106 125 150 25 25.5 SIGILA 100 SIGILA 125 SIGILA 150 a D c Type SIGILA 100 SIGILA 125 SIGILA 150 à 15 17 205 c D e 120 140 108/93 114/96 100 125 12 13 165 132 150 14 e LARUS, SIGILA and SIGILA MOTION fans can e supplied with a ack valve. In this case, the spigot lenght is increased y 14mm. Fan c D Back valve L= C + 14 tale 1 5

DELIVERY SET The delivery set: Fan - 1 item; Screws and dowels - 4 items (except for FENESO serie); Screw, olt, nut, plastic nut - 4 items (for FENESO serie); Gasket - 2 items (for FENESO serie); Connecting screws - 2 items (for FENESO SERIE); Plastic screwdriver - 1 item (only for the models with a timer); User manual - 1 item; Packing ox - 1 item. MOUNTING AND SET-UP The fan mounting sequence is shown in figures: - LIBELLA / SIGILA MOTION - fig. 1; - FENESO - fig. 2; - CICONUS / LARUS / SIGILA - fig. 3; The fan shown in figures may slightly differ from your model. Still, the mounting sequence is the same. The fan connection to the fixed power mains is shown in fig. 7-10. The circuit oard setup is shown in fig. 15. 6

Fig. 1. LIBELLA / SIGILA MOTION fan series 1.1 1.2 1.3 1.4 1.5 1.6 1.7 7

Fig. 2. FENESO fan serie 2.1 2.2 2.3 2.4 2.5 180 mm FENESO 150 160 mm FENESO 125 8

Fig. 2. FENESO fan series (continued) 2.6 2.7 2.8 2.9 9

Fig. 3. CICONUS / CYCNUS / LARUS / SIGILA / SIGILA MOTION fan series 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 10

fig. 7 220-240 V (12 V*) Wiring diagram for connection of the fan with a pull-cord switch and of the fan with a motion sensor. fig. 8 S 220-240 V (12 V*) Wiring diagram for connection of the fan without a pull-cord switch. fig. 9 L (~*) LT (ST*) 220-240 V (12 V*) N (~*) Wiring diagram for connection of the fan with a timer/ timer with a humidity sensor and a pull-cord switch. Designation keys L - phase (only for 220-240 V power mains) N - 0 (only for 220-240 V power mains) S - external switch S1 - external fan switch S2 - external light switch fig. 10 L(~*) LT (ST*) N (~*) S 220-240 V (12 V*) Wiring diagram for connection of the fan with a timer/ timer with a humidity sensor, without a pull-cord switch. * - the fan rated for 12 V power mains (marked on the fan casing) connect to 12 V power mains only! 11

ELECTRONICS OPERATING LOGIC The fan with the timer T - the fan starts after actuation of the external switch, e.g. the light switch. The control voltage is supplied to the input terminal LT (ST, SL). After the control voltage is off, the fan continues to operate within the set time period adjustale from 2 to 30 minutes y the timer. The VT model is turned on and off y the pull-cord switch. The fan with the timer and the humidity sensor TH - the fan starts after the external switch, e.g. the light switch, supplies control voltage to the input terminal LT (ST, SL) or if indoor humidity level H exceeds the set point adjustale from 60% to 90%. After the control voltage is off, the fan operates within the time period set with the timer from 2 to 30 minutes. The fan with the timer and the motion sensor TM- the fan starts after motion detection at the distance from 1 to 4 m and the horizontal viewing angle of 100. After no more motion is detected, the fan operates within the time period set with the timer from 2 to 30 minutes. Warning! The timer circuit is under mains voltage. Disconnect the fan from power mains prior to any adjustment operations. The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. Use the screwdriver to change the turn-off delay time or the humidity set point. Do not use a metal screwdriver, knife, etc. for adjustment operations not to damage the circuit oard. Read the user manual carefully prior to adjustment. Rememer that the circuit oard and potentiometers have various locations depending on the fan models. 12 fig. 14

For the timers T, TH and TM: LARUS / CICONUS / CICNUS / SIGILA LIBELLA / FENESO / SIGILA MOTION H H - + - + T - T + - H + 2min 2min 30min 60% 90% fig. 15 13

MAINTENANCE Disconnect the fan from power mains prior to any maintenance operations. For cleaning use a soft cloth or rush and mild detergent water solution. Avoid water dripping on the electric components. Wipe the surfaces dry after cleaning. STORAGE REGULATIONS Store the fan in the manufacturer's original packing ox in a dry ventilated premise at the temperatures from +5 C up to + 40 C and relative humidity less than 80% (at the temperature +25 C). MANUFACTURER'S WARRANTY By purchasing this product the customer confirms to have read and agreed to the terms, rules and requirements related to operation, storage, transportation, mounting, adjustment, connection, maintenance and repair as well as warranty oligations with respect to this product as set forth in the manufacturer's accompanying documentation to the product. The manufacturing company sets forth the warranty period (service life) of the product as 60 months following the sale date via retail network suject to the customer's ensuring compliance with the rules of transportation, storage, mounting and operation of the product. In case of any malfunction of the product through the fault of the Manufacturing company within the warranty period (service life), the customer shall have the right to elimination of the manufacturing defects y means of warranty servicing performed free of charge. The warranty servicing implies performance of activities related to elimination of defects in the product aimed to provide intended use of the product y the customer. The defects are eliminated either y replacing or repairing such a product or a part (component) thereof. NOTE: with the purpose of performing warranty servicing you please produce User Manual or other relevant sustituting document and the payment document as an evidence of the purchase with indication of the sale date. The product model shall comply with that one specified in the User Manual or other relevant sustituting document. 14

With the purpose of performing warranty servicing please contact the trade company where you purchased the product. If warranty servicing on the spot proves impossile, you will e provided with the necessary information regarding rendering of this service. Manufacturer's warranty shall not apply in the following cases: in case the customer fails to provide the product in complete according to the package contents specified in the User Manual or other relevant sustituting document, including any components disassemled y the customer; in case of incompliance of the model or marking of the product with data specified on the product packaging and in the User Manual or other relevant sustituting document; in case of non-timely technical maintenance of the product y the customer (dust, mud, oil condensate, foreign particles); in case of causing external damage to the product y the customer ('damage' shall not apply to external changes of the product required for the product mounting); in case of altering the product design or further reworking of the product; in case of replacing and using parts, units and components of the product not prescried y the manufacturing company; in case of other use of the product other than intended use; in case of the customer's violating product operation rules; in case of connecting the product to electric mains of voltage exceeding voltage value specified in the user's manual; in case of step voltage that resulted in the product failure; in case of the customer's performing unauthorised repair of the product; in case of performing repair of the product y third persons unauthorized y the manufacturing company; in case of warranty period (service life) expiry; in case of the customer's violating transportation rules assuring prevention of damaging and/or destruction of the product; in case of the customer's violating product storage rules; in case of performing unlawful actions y third persons with respect to the product; 15

in case of force majeure (fire, flood, earthquake, war, hostilities of any kind, lockade); in case of asent seals, provided such seals are prescried y the User Manual or other relevant sustituting document; in case of unavailale warranty card; in case of unavailale payment document to confirm the purchase with indication of the sale date. The manufacturing company shall e responsile for defects arising through its fault prior to the moment of transferring the product to the ownership of the customer. The manufacturing company shall not e responsile for defects arising after transferring the product to the customer and caused y the customer's violating the rules of transportation, storage, assemly and operation of the product, or y actions of third persons, an accident or force majeure circumstances. The manufacturing company shall not e responsile for damage to health and property of the customer caused y the customer's violating the User Manual or other relevant sustituting document; other use of the product y the customer other than its intended use, or y failure of the customer to comply with warnings and other information on the product specified in the User Manual or other relevant sustituting document, or y the customer's violating the rules of transportation, storage, mounting, maintenance and operation of the product. 16

DECLARATION OF CONFORMITY Model We herey declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Memer States relating to electromagnetic compatiility. This certificate is issued following test carried out on samples of the product referred to aove. Assessment of compliance of the product with the requirements relating to electromagnetic compatiility was ased on the following standards. Manufacturing date Approval mark Sold (name and stamp of the trade company) Date of sale VENTILACION INDUSTRIAL IND, SL Ctra. Camprodon s/n 17860 Sant Joan de les Aadesses (Girona) SPAIN CV072014-1