Product Name Here. SHURTrim Paraffin Block Trimmer. Operator s Manual. Histology Innovation for a NEW Generation. Catalog #s ST-120, ST-220

Similar documents
# TFB-S-120, TFB-L-120 TFB-S-220, TFB-L-220 FWS-S-120, FWS-L-120 FWS-S-220, FWS-L-220

Power Supply Display Module PSDM. Installation and Operation Manual

Digital Heat Block User Manual

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

4100U City and Relay Cards Installation Instructions

AUTOMATIC STERILIZERS

Rack Mount Series Installation Guide

Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

Slide Warmer. Model XH-2001 Model XH Operating Manual

TEMPERATURE CONTROLLER (STANDARD MODEL)

OPERATING INSTRUCTIONS

PL400 Patient Lift Scale Indicator Owner s Manual

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Alarm Tone Generator Model AG17

4 & 8-POINT ANNUNCIATORS Instruction Manual

108A OTP1800. Grid Support. General Description

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

P4200PM / P5000PM Remote Air Dryer User s Guide

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Dry Bath Heating Systems

Model PT-05 Model PT-06

Operating Instructions

Undercounter Refrigerator Operation Manual i.series and Horizon Series

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

OPERATOR S MANUAL DEAD AIR WORKSTATION. AC600 Series Dead Air Box & Timed UV Light with UVTect Controller

qube mini Overview

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Power Conditioners User s Manual. For use with Standard Power Conditioners, Medical Power Conditioners and Ground Guard Power Conditioners

SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Reacti-Therm I and III Heating Modules

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

Cisco TelePresence MCU 4200 Series safety and compliance information

Thermo-Sealer. Manual Heat Sealer. User Manual

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

Oakton TEMP 9500 Advanced Multiparameter Controller

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

TTT Digital Incubator

LORAIN CIP 4890/48120 DC Power System

Electron Microscopy Sciences. INSTRUCTIONAL MANUAL CAT & Step Up Slide Warmer

MD-MINI Dry Bath. Instruction Manual

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Corning LSE Digital Dry Bath Heater

REC-8R Environmental Control. Operation and Installation Manual

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Square D Clipsal Outdoor Light-Level Sensor

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

Panel Mounted Heat Exchangers by Dantherm, Inc.

Operation Manual. (Version 1.5.1)

Fan Coil Thermostat. Specification & Installation Instructions TFC54F3Y1. Technical Data

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Class A and Expansion NAC Modules Installation Instructions

ph COOLING TOWER CONTROLLER

Black Body Calibration Source User Manual

HI COD REACTOR and Test Tube Heater 2008 Series

Liebert InteleCool Warranty Inspection Check Sheet

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Hotplates, Magnetic Stirrers and Stirring Hotplates

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

User Manual. Tanner 1500 Embedding Center

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

General Information on Finishing with Your Raytech Centrifugal Magnetic Finisher

Instrument Processing. Midmark Animal Health Products

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

Reacti-Therm I and III Heating/Stirring Modules

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Regulatory Information and Specifications

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

LORAIN CSP DC Power System

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Corning LSE 6L Digital Water Bath

/9308 External Battery Chargers Installation Instructions

Liebert PPC Second Generation Power Distribution Cabinet

Warming Drawer Installation Guide

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

Control Relay Modules

Microplate Heat Sealer, Variable Temperature

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

CLASSIC PLUS INFRARED ZONE HEATER

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

Installation Guide for models:

Isotemp Plus General Purpose Laboratory Freezers

P6500W Air Dryer User s Guide

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

LABORATORY ILLUMINATED FLOTATION BATH

MODEL 721 ELECTRICAL DATA: FEATURES: ACCESSORIES: DIMENSIONS: SHIPPING INFORMATION: CONVECTION OVEN 1/2 SIZE PAN

Transcription:

A Division of General Data Healthcare Histology Innovation for a NEW Generation Pub No.: OM ST-120/220 June 2013, Version 7.4 ST-120; ST-220 Operator s Manual SHURTrim Paraffin Block Trimmer Product Name Here Catalog #s ST-120, ST-220

2 P age

TABLE OF CONTENTS Topic Page Warranty card Insert A Introduction 2 Symbols and conventions 3 Overview and specifications 4 Instructions 7 Precautions and maintenance 8 Regulatory Compliance 9 Contact information 11 3 P age

INTRODUCTION Congratulations on your decision to purchase a TBS SHURTrim Paraffin Block Trimmer. Your instrument is designed to remove excess paraffin from embedded tissue cassettes. Simply slide paraffin blocks across the heated grooved surface. Melted paraffin is shaved away to conveniently positioned disposable receptacles. Preparing embedded tissue blocks for insertion into microtome quick release clamps has never been easier or safer. 4 P age

Symbols and Conventions Important Notice Hot Surface 5 P age

OVERVIEW AND SPECIFICATIONS TBS SHURTrim Paraffin Block De-waxer 6 P age

SHURTrim Control Panel Flashing green indicates power off to the metal plate. Blinking red indicates power to heating element on but set temperature not reached. Solid red indicates that the set temperature of the metal surface has been achieved and the microprocessor has begun to regulate the temperature. 7 P age

Specifications Specification North American and Japan International Dimensions Height 15cm (6 ) Width 23cm (9 ) Depth 18cm (7 ) Height 15cm (6 ) Width 23cm (9 ) Depth 18cm (7 ) Voltage 120VAC ± 10% 230VAC to 240VAC ± 10% 50/60Hz single phase 50/60Hz single phase Operating Current 2.0 A 1.0 A Default Temperature Setting Maximum Temperature Setting Power 240 W 240 W Fuse 3.15 A 1.6 A Weight 60C 75C Unit 3kg (5 lbs) Shipping 4kg (9 lbs) 60C 75C Unit 3kg (5 lbs) Shipping 4kg (9 lbs) 8 P age

INSTRUCTIONS 1. Remove the equipment from the shipping carton carefully. Save the shipping carton and all packing material until proper operation of the equipment is confirmed. Immediately notify the carrier if there is any visible damage to the carton or its contents. Failure to do so may limit your ability to obtain compensation for damage. NOTE: Be certain to complete the warranty card and insert into the mail. Failure to do so within 10 day from the date of the invoice may invalidate your warranty. 2. Connect the power cable to the unit and into a properly grounded outlet. NOTE: If your unit was shipped outside of the U.S., check the label on the rear of the instrument for the electrical requirements. 3. Switch the ON/OFF switch at the rear of the unit to the ON position as indicated by the I being flush with the instrument housing. Pressing the O inward turns the unit off. 4. Immediately upon turning the unit on, the unit will go through a short power up test. Each segment of the display will turn fully on as will the heat indication LED. Then they will turn off and the unit will display the current temperature of the plate (if the unit has not been on for a while, this should be approximately room temperature of 20C to 25C). 5. Press the HEAT key to initiate the heating. The small LED indicator will light up red and will stay illuminated. During the warm up phase, the red indicator light will blink red. Once the set temperature has been reached and is stable, the red LED will stop blinking and remain on. This is an indication that the controller is functioning to regulate the temperature. A red solid light is the normal operational mode. 6. To increase or decrease the preset temperature, press the SET key and then press the decrement (down arrow) or increment (up arrow) keys until the desired temperature is displayed. The optimal operating temperature for melting most paraffins in a reasonable time frame without the unit being too hot to work comfortably is approximately 60 C - 65 C. 9 P age

PRECAUTIONS AND MAINTENANCE When initializing operation, please allow sufficient time for the heated plate to reach the desired temp (approximately 10 min or less). The actual temperature displayed can differ by a degree or two from the set temp depending on the room temperature and the air circulation surrounding the unit. Your SHURTrim Block Trimmer is designed to run continuously; however, a power surge can disrupt the operation. If this happens, the unit turns off the heat for safety reasons and will return to room temperature. It will require pushing the HEAT key to reactivate the heating function. The unit can be connected to a surge protector or some form of uninterrupted power source to ensure against such disruptions. To save electricity, it is recommended that the unit be powered off following use. When powering on the next morning, be certain to push the HEAT button to activate heating. The fuse holder is part of the power entry module on the rear of the unit. Utilize only the indicated fuse rating. Little maintenance is required except to remove any paraffin spillage and/or buildup. A small apparatus (cat# ST-PCH) is included for positioning disposable cups under the drain tube to collect melted paraffin. An initial supply of cups is included. Additional ones can be ordered. Specify cat # ST-PDC. 10 P age

REGULATORY COMPLIANCE The ST-120/ST-220 SHURTrim Block Trimmer has been tested to rigorous international quality safety standards and has been found to be in compliance with the appropriate regulations and specifications relating to laboratory instrumentation including: Emissions North American and Japan US - FCC Class B for the 120VAC version US - FCC Class A for the 230VAC version US - ISO Standard 17025:2005 (Lab code: 200094-0) Canada - ANSI C63.4-2003 Japan - Regulations for Voluntary Control Measures Emissions European Community EN 61326-1:2006 Product Family Standard Immunity EN 61326-1:2006 Product Family Standard Emissions EN 55011:2007 EN 55011:2007 EN61000-3-2:2006 EN61000-3-3:1995 +A1:2001 +A2:2005 EN61000-4-2:1995 +A1:1999 + A2:2001 EN61000-4-3:2006 EN61000-4-4:2004 EN61000-4-5:2005 EN61000-4-6:2007 EN61000-4-8:1993 +A1:2001 EN61000-4-11:2004 Safety UL 61010A CSA 61010-1 CE EN61010-1 11 P age

ST-120: Serial Number Labels TBS A Division of General Data Healthcare 3014 CROASDAILE DRIVE DURHAM, NC 27705-2507 USA 919.384.9393 FAX 919.384.9595 www.trianglebiomedical.com Model SHURTrim CAUTION: NO USER SERVICABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE ANY ENCLOSURE PARTS. AT THE DATE OF ITS MANUFACTURE, THIS INSTRUMENT OR DEVICE HAS BEEN TESTED AND FOUND IN FULL COMPLIANCE WITH THE FOLLOWING STANDARDS: CAT # ST-120 Serial Number 2908ST0075-03 Rev. # 03 MFG July 2009 Volts 100-120 Amps 2 Hz 50/60 ST-220: TBS A Division of General Data Healthcare 3014 CROASDAILE DRIVE DURHAM, NC 27705-2507 USA 919.384.9393 FAX 919.384.9595 www.trianglebiomedical.com Model SHURTrim CAUTION: NO USER SERVICABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE ANY ENCLOSURE PARTS. AT THE DATE OF ITS MANUFACTURE, THIS INSTRUMENT OR DEVICE HAS BEEN TESTED AND FOUND IN FULL COMPLIANCE WITH THE FOLLOWING STANDARDS: MADE IN USA CAT # ST-220 Serial Number 2908ST0075-03 Rev. # 03 MFG July 2009 Volts 230-240 Amps 2 Hz 50/60 12 P age

CONTACT INFORMATION Customer service (919) 384-9393 Fax (919) 384-9595 Mailing address TBS A Division of 3014 Croasdaile Drive Durham, NC 27705 U.S.A. Sales and product information sales@trianglebiomedical.com Product Service questions productservice@trianglebiomedical.com All other inquiries tbs@trianglebiomedical.com Please visit us at http://www.trianglebiomedical.com 13 P age

More Information PH: 844.643.1129 www.general-data.com/hc General Data Healthcare helps labs enhance productivity and improve workflow with innovative products, solutions and support that focus on delivering better patient safety & care. 2014 All rights reserved. Specifications are current at the time of publication; however, they are subject to change without notification. All trademarks and registered trademarks are property of, Cincinnati, Ohio, USA. Sales Inquiries: PH: 844.643.1129 Email: talktous@general-data.com Web: www.general-data.com/hc Headquarters: 4354 Ferguson Drive, Cincinnati, OH 45245 TBS Facility: 3014 Croasdaile Drive, Durham, NC 27705 Service: PH: 800.245.5029 Email: customersupport@general-data.com