INDITHERM. Low temperature gas burners

Similar documents
INDITHERM. Low temperature gas burners

V-Line. Nozzle-mix line burner

DELTA-TE III. Nozzle-mix line burner

"NP" & "RG" AIRFLO. In-duct firing line burner

APX. Nozzle-mix line burner

"HC" AIRFLO. In-duct firing line burner

Specifications of V-Line burners

Series LV AIRFLO. In-duct firing line burner

Specifications of MULTIFIRE burners

TUBE-O-THERM Low Temperature Gas Burners

PACKAGED METALLIC BURNERS

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Design and Application Details

INDUSTRIAL MICRODIFFUSION OIL BURNERS

FLAT FLAME AND EXCESS AIR BURNERS

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

RIELLO 40 GS/M SERIES

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Eclipse AirHeat Burners

OPERATING AND MAINTENANCE MANUAL

Eclipse RatioMatic Burners

PBG PACKAGED GAS BURNER

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

Eclipse AirHeat Burner

LOW NOx MODULATING GAS BURNERS

Installation Instructions

NMC Nozzle Mix Gas/Oil Combination Burners

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

RS /E-EV C01 SERIES

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

MULTIPLEX SELF RECUPERATIVE gas burner

Energy saving and better heat control.

Eclipse Self-Check UV Scanner

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Chemical Processes in the Combustion

RS /E-EV C01 SERIES

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Distributed By: M&M Control Service, INC

North American Flame Detector Adapters 8832 through 8839 and Series R

5.0 ALARMS & TROUBLESHOOTING

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Steam Fundamentals. (in heating & processing applications)

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

USER S INFORMATION MANUAL

Age Ovens. This chapter is available for sponsorship. For information contact

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE.

ECLIPSE INFORMATION GUIDE

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

HAUCK STARJET BURNER SJ075 SJ980

Self-recuperative burner for gas

NMG NOZZLE MIX GAS BURNERS

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Distributed By: M&M Control Service, Inc Building Technologies

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

1 - High-velocity gas burners

GV Series 4 Section Assembly

FLAME DETECTOR ADAPTERS 8832 through 8839 and Series R Bulletin 8832

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

STR-Series Indirect-Fired Air Turnover Units

FIREYE FLAME SCANNERS

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

Type CG Series Forced Draft Gas Burner

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Indirect gas-fired air heater

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Power Flame Incorporated

FIREYE C9707A ALL FUEL SCANNER

Control valve S11T. Pilot burner ZT. Control valve S11T

FIREYE FLAME SCANNERS

PVE SERIES POWER VENTER SYSTEM MANUAL

POWER VENTER. Model: PVE Series

26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

FIREYE FLAME SCANNERS

ROTARY DRYER CONSTRUCTION

GAS AND PELLET BURNERS

Installation Instructions

Domestic Hot Water Heaters and Boilers FTIIIC-6

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

Flame115 Radiant. Flame115 Specifications. Flame115 Accessories

Transcription:

INDITHERM Low temperature gas burners 1-2.3-1 High turndown for maximum operation flexibility. Maximum capacities up to 1800 kw. Designed for firing in indirect fired processes. Excellent combustion throughout entire capacity range. Maximum application flexibility with 8 available burner sizes. Packaged design for quick and easy installation. Alternate refractory block materials for high temperature applications.

1-2.3-2 Product description The INDITHERM burner is a nozzle-mix burner, suitable for firing natural gas in many industrial indirect-fired applications where clean combustion and a high turndown are required. They offer a simple and versatile answer to a wide variety of applications. The INDITHERM burner incorporates a gas and air valve linked together to control the gas/air ratio over the full operating range. The linkage between gas and air valve is internal in the burner and is factory adjusted. No fine tuning or adjustments in the field are required. To control the capacity, a low torque control motor can be attached directly onto the burner. The burner can accept most commonly used brands and types of control motors. The required combustion air is provided by an integrated combustion air blower. This blower is mounted directly onto the burner's housing, thus ensuring a good combustion air distribution inside the burner at all times. The gas enters the burner through the burner gas inlet connection. It flows through the nozzle and then along the inside of the burner mixing cone where combustion air is progressively and tangentially mixed with the gas. This results in a very wide range of turndown and a highly stable flame under a variety of operating conditions. The burner has an integrated pilot burner with its own flow adjusting orifice. If required the INDITHERM can be direct ignited without the use of a pilot. Provision is made for a single UV scanner to monitor both gas pilot and main flame. 1) Burner body 2) Burner discharge sleeve 3) Combustion air blower 4) Spark ignitor 5) Flame detector 6) Control motor 7) Connecting bracket and linkage 8) Pilot gas adjusting needle valve 9) High voltage ignition transformer 10) Combustion air pressure connection (Rc1/4 ) 11) Gas inlet 3 1 4 2 4 11 6 8 9 5

1-2.3-3 Available INDITHERM sizes Typical burner data Fuel: natural gas at 15 C with 10.9 kwh/nm 3 HHV - sg = 0.6 [1] Combustion air: 15 C - 21% O 2-50% humidity - sg = 1.0 [1] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel, and gas quality. Burner size & type 100 200 300 550 700 850 1100 1500 1800 Max. capacity [2] kw (HHV) 125 233 340 550 750 850 1050 1472 1800 Min. capacity kw (HHV) 6.5 5.5 4.5 10 17 15 45 25 25 Gas pressure [3] mbar 3.0 4.4 7.5 5.7 8.5 11.9 17.7 5.2 9.4 Flame length [4] m 1 1.5 1.2 2 2.1 2 2.3 2.6 3-4 [1] sg (specific gravity) = relative density to air (density air = 1.293 kg/nm 3 ) [2] Maximum capacity at 3% 0 2 firing, no back pressure in combustion chamber. When firing into a tube under slight over pressure, maximum capacity will be reduced. See Specifications of INDITHERM burners for more information. [3] Gas pressures for natural gas at burner inlet. The stated pressures should be available at burner inlet throughout the entire capacity range. See Specifications of INDITHERM burners for more information. [4] Flame lengths are derived from measured lab data. Actual flame lengths can differ slightly. Every INDITHERM is available in an ISO and NPT version. The burner is designed to operate at a 230/400V - 50Hz supply voltage. The burner is designed and factory adjusted to operate at 50Hz. When only 60Hz is available, please contact MAXON.

1-2.3-4 Applications Because of its versatility, the INDITHERM can cover numerous types of applications. All types of indirect-fired applications can be equipped with this simple, industrial burner. Among the major applications there are automotive paint-bake ovens and surface treatment, bakery ovens and dryers for the food industry. INDITHERM 1100 gas burner with natural gas pipe train, including MAXON 5000 shut off valves. System used on paint dry ovens in automotive industry.

1-2.3-5 Dimensions and weights INDITHERM - all sizes 1) Gas inlet Dimensions in mm unless stated otherwise Burner size Gas inlet [1] A B [2] C Ø D [2] E Weight (kg) [3] 100 1 365 225 200 160 224 30 200 1 365 225 200 160 224 30 300 1 1/4 365 224 200 210 224 34 550 1 1/2 514 255 200 260 308 50 700 2 598 255 200 260 387 50 850 2 598 255 200 260 387 50 1100 2 597 365 200 311 387 71 1500 2 597 365 200 311 387 71 1800 3 659 365 200 311 451 71 [1] Gas connections are threaded (NPT or ISO) [2] These dimensions only apply when a standard discharge sleeve is used. Refer to Specifications of INDITHERM burners in case refractory sleeve will be used and for more detailed dimensions. [3] The weight applies for burners with standard discharge sleeve. Burners with high temperature refractory sleeve will have significantly higher weights. Refer to Specifications of INDITHERM burners.