Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Similar documents
Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

Convection Heat Transfer from Horizontal Rectangular Fin Array having Triangular Perforations

Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

I. INTRODUCTION. Types of Fins:

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

HEAT TRANSFER ENHANCEMENT IN SHELL AND TUBE HEAT EXCHANGERS USING INSERTS

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

American International Journal of Research in Science, Technology, Engineering & Mathematics

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

Modified Air Cooler with Split Cooling Unit

Performance Study of Triple Concentric Pipe Heat Exchanger

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Raman et al., International Journal of Advanced Engineering Technology E-ISSN

Assistant Professor),( Professor), Department of Mechanical Engg., B.I.T. Sindri 3. Professor, Department of Mechanical Engg., N.I.T.

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

International Journal of Informative & Futuristic Research ISSN (Online):

Design and Development of Water Cooled Condenser for Domestic Refrigerator

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

LAB EQUIPMENT DETAILS

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

1, 2

a Heat Exchanger using FEA Tool

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Experimental Investigation of Tube Configuration for a Surface Condenser

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

2. HEAT EXCHANGERS MESA

Heat transfer and heating rate of food stuffs in commercial shop ovens

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

How is the heat transfer?

To investigate the surface properties for increasing efficiency of solar water heater

Performance investigation of Air-conditioning system using ejector as expansion device

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Solar Drying Techniques And Performance Analysis: A Review

Thermal Performance of a Loop Thermosyphon

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

Global Journal of Engineering Science and Research Management

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

A Study of Heat Transfer Using Corrugated Al 2 o 3 microparticles

Heat Transfer Enhancement in Shell and Tube Condenser

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN


Compression of Fins pipe and simple Heat pipe Using CFD

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

A REVIEW ON HEAT EXCHANGER

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

A Review of Electro Thermal Cooling Systems with Heat Sink

Heat Exchangers. Heat Exchangers 1

Heater Surface Coating Effect on Fluidized Bed Heat Transfer Coefficient

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

ENSC 388: Engineering Thermodynamics and Heat Transfer

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

PASSIVE CONTAINMENT COOLING: MODEL EXPERIMENTS

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER

Heat Transfer in Evacuated Tubular Solar Collectors

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Transcription:

International Journal of Modern Studies in Mechanical Engineering (IJMSME) Volume 4, Issue 1, 2018, PP 11-16 ISSN 2454-9711 (Online) DOI: http://dx.doi.org/10.20431/2454-9711.0401002 www.arcjournals.org Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array Prof.S.A.Wani 1, Prof.A.P.Shrotri 2, Prof.D.K.Patil 3, Prof.A.A.Nannikar 4 1,3,4 Assistant Professor, Padmabhooshan Vasantraodada Patil Institute of Technology, Budhgaon, Sangli 2 Associate Professor, Padmabhooshan Vasantraodada Patil Institute of Technology, Budhgaon, Sangli *Corresponding Author: Prof. S. A. Wani, Assistant Professor, Padmabhooshan Vasantraodada Patil Institute of Technology, Budhgaon, Sangli, India Abstract: Convective heat transfer is the transfer of heat from one place to another by the movement of fluids, a process that is essentially the transfer of heat via mass transfer. Bulk motion of fluid enhances heat transfer in many physical situations, such as between a solid surface and the fluid. Convection is usually the dominant form of heat transfer in liquids and gases. Although sometimes discussed as a third method of heat transfer, convection is usually used to describe the combined effects of heat conduction within the fluid (diffusion) and heat transference by bulk fluid flow streaming. This paper refers to the convective heat transfer from a V-Fin Array which is blackened. Blackened V-Fins array are examined. Keywords: Blackened Fin Array, Heat Transfer, Natural Convection,, Vertical Plate, V-Fins 1. INTRODUCTION Free, or natural, convection occurs when bulk fluid motions (streams and currents) are caused by buoyancy forces that result from density variations due to variations of temperature in the fluid. Forced convection is a term used when the streams and currents in the fluid are induced by external means such as fans, stirrers, and pumps creating an artificially induced convection current. Natural or free convection is observed as a result of the motion of the fluid due to density changes arising from the heating and cooling process. Natural convection represents an inherently reliable cooling process. Further, this mode of heat transfer is often designed as a back up in the event of the failure of forced convection due to fan break down. Fins are commonly applied for heat management in electrical appliances such as computer power supplies or substation transformers. Fins are used to enhance convective heat transfer in a wide range of engineering applications, and offer a practical means for achieving a large total heat transfer surface area without the use of an excessive amount of primary surface area. Other applications include Internal Combustion engine cooling, such as fins in a car radiator. Feasible and practical means to improve natural convection heat transfer is by the use of finned surfaces. 2. LITERATURE REVIEW Starnar and McManus [1] determined average heat transfer coefficients for four arrays positioned with base vertical, at 45 and horizontal. It was found that vertical arrays performed 10-30 % below the similarly placed parallel plates. The arrays at 45 performed 5-20 % below the vertical arrays and horizontal fin arrays performed lowest. Flow visualization tests were conducted using smoke technique. Baskaya et al. [2] carried out parametric study of natural convection heat transfer from the horizontal rectangular fin arrays. They investigated the effects of a wide range of geometrical parameters like fin spacing, fin height, fin length and temperature difference between fin and surroundings, to the heat transfer from horizontal fin arrays. However, no clear conclusions were drawn due to the various parameters involved. Wankhede et al. [3] developed an experimental setup to carry out the investigation on horizontal rectangular fin array with and without inverted notch under natural and forced convections. The objective of the work was to determine the heat transfer International Journal of Modern Studies in Mechanical Engineering (IJMSME) Page 11

characteristics experimentally, and further to find out the enhancement in heat transfer in the case of notched fin arrays over normal fin arrays, and analyzed the effect of different parameters like length, height, spacing of fins on heat transfer coefficient (h). Karagiozis [4] experimentally investigated the problem of free convection from isothermal vertical base rectangular fin arrays, the fin cross-section being rectangular and triangular. He studied two different orientations of fins: viz. vertical and horizontal and also studied the arrays with blocked ends with both fin orientations. He also carried out experiments to determine the radiation contribution. Prasolov et al. (1961) [5], Heya et al. (1982) [6], Bhavnani et al.(1990) [7] suggested that the roughness elements whose height is less than the boundary layer thickness will have no appreciable influence on the heat transfer of natural convection and these elements will work as flow retarder rather than the heat transfer promoter. An interferometric technique was used to determine local heat transfer coefficients for surfaces with repeated ribs and steps. Barhatte et al. (2012) [8] did the study on heat transfer rate through different types of notches in the fin. He used different notches such as rectangular, circular, triangular and trapezoidal. He compare without notch and notch fin array by supplying different heat inputs. The dimensions of fin were fixed. They concluded that more heat is transfer through triangular notch fin. Tsuji et.al. (2007) [9] conducted an experimental study on heat transfer enhancement for a turbulent natural convection boundary layer in air along a vertical flat plate has been per-formed by inserting a long flat plate in the span wise direction (simple heat transfer promoter) and short flat plates aligned in the span wise direction (split heat transfer promoter) with clearances into the near-wall region of the boundary layer 3. SUMMARY OF REVIEW From the above literature review, it is seen that, 1. Very few researchers have worked on Vertical 2. Less work is carried out on Vertical 3. No any work has been carried out on V-fins with Blackened surfaces 4. EXPERIMENTAL SETUP Enhancement of heat transfer under natural convection conditions can be achieved by attaching the horizontal surface fins to the base plate. The arrangement will be vertical and the fins will be attached to the surface of the base plate. From the literature survey, it is found that very few investigators have worked on the problems related to this type of arrangement. Hence, it is decided to carry out an experimental work to find the enhancement in heat transfer by a special V-fin arrangement. The basic consideration will be, the total length of rectangular fins will be equal to the total length of V-fins. Therefore, the surface area during both conditions will be equal. In order to ascertain the characteristics of V-fins, the rectangular fins will be sticked to form V-fins on the base plate. Therefore, same height of both fins will be there and the enhancement in heat transfer for both conditions can be carried out. The base plate is divided into four equal parts. The heaters are placed between the base plate at an equal length from each other for effective heat distribution to the base plate. The enclosure used is for the development of undisturbed natural convection condition Figure1. Experimental Setup 1.Dimmerstat 2. Fin Array 3. Temperature Indicator 4. Ammeter 5. Voltmeter International Journal of Modern Studies in Mechanical Engineering (IJMSME) Page 12

5. DEVELOPMENT OF SYSTEM The system is designed and developed for the measurement of heat transfer parameters for which the details are as follows: The base plate used for experimentation work is made up of aluminium and of dimension 200mm X 200mm X 25mm. Several markings are done on the base plate to identify the positions of rectangular fins as well as V-fins. The hooks are attached to the base plate with the help of screws. The strings will be attached to the hooks for positioning the base plate right at the mid center of the enclosure. The rectangular fins are arranged in such a way that they look like a V-fin. Figure2. The cartridge type heater of dimension Ø 5mm X 200mm was used. The heaters were placed in the holes inside the base plate symmetrically. The rated power output was 260 Watts. Enclosure is used to obtain an effective natural convection condition. The setup is hanged at the top side of the enclosure. The enclosure is covered with acrylic sheets from all the four sides for observation purpose. The enclosure is 1m x 1m x 1m in dimension. Figure3. Plain Plate with Fins Figure4. Plain Plate with V- Fins International Journal of Modern Studies in Mechanical Engineering (IJMSME) Page 13

The experimental procedure carried out is as follows: Initially, the enclosure is opened from two sides. This is in order to hook the test plate to the enclosure from inside end. After that, the sides of the enclosure are closed by acrylic sheets. The connections of the thermocouples were made at required positions. The remaining electrical connections are checked i.e. connections of heater, wattmeter and dimmer stat etc. The heater is heated by supplying a.c.current through dimmer stat and wattmeter. After checking all the connections, the switch of temperature indicators and dimmer stat is turned ON. The temperatures at different points were read by the digital temperature indicator and were recorded at a time interval of 30 minutes. The heater input was kept constant by varying the dimmer stat to account for voltage fluctuations. The final reading was recorded when steady state is reached. 6. 6. RESULTS AND DISCUSSIONS After certain series of observations and calculations, the results found are as follows: Table1. Results of Temperature Difference Sr.No. Heater Input Q (W) Plate with fins Temperature Difference T ( C ) (Apex upwards) 1 50 18.42 18.06 18.63 2 75 26.60 26.37 27.00 3 100 34.19 34.16 34.98 As the whole surface being black, the radiation increases thereby reducing the temperature at all the nodes. For Blackened surface, the lowest temperature difference is found out to be for V-fins with apex facing downwards configuration. Table2. Results of Average heat transfer coefficient Sr.No. Heater Input Q (W) Plate with fins Average heat transfer coefficient h - W/m 2 K (Apex upwards) 1 50 6.96 7.16 6.82 2 75 7.21 7.29 7.02 3 100 7.47 7.48 7.16 International Journal of Modern Studies in Mechanical Engineering (IJMSME) Page 14

From the graph, it has been observed that the average heat transfer coefficient for V-fins with apex downwards configuration has the highest value and thereby has more better performance in comparison with the other configurations. Table3. Results of Nusselt Number Sr.No. Heater Input Q (W) Plate with fins Nusselt Number Nu (Apex upwards) 1 50 51.96 53.34 50.7 2 75 53.10 53.67 51.57 3 100 54.33 54.35 52.00 From the graph, it has been observed that the value of Nusselt Number for V-fins with Apex facing downwards is higher than the other configurations. As Nusselt Number is higher, this type of configuration will give better performance as compared to other fin configurations. 7. CONCLUSION 1) In case of V-Fins with Apex facing Downwards configuration, the average heat transfer coefficient is in the range of 7.16 7.48 W/m 2 K which is the highest value of average heat transfer coefficient for any other configuration. This concludes that V-Fins facing downwards give better performance than Vertical Plate with Vertical Fins and V-Fins with Apex upwards. 2) As the heater input increases from 50W to 100W, the temperature difference also increases, and it is observed that for V-Fins with Apex facing downwards configuration, the temperature difference is in the range of 18.06 34.16ºC, which is the lowest as compared to any configuration. This means that this configuration gives the better performance. 3) Nusselt number value for V-Fins with Apex facing downwards configuration is in the range 53.34 54.35, which is the highest as compared to other configurations. 4) The V-Fins arrangement has good heat transfer performance than a plain vertical plate because it acts as a flow disturber to heat flow over the plate. REFERENCES [1] Starner K.E.and Mcmanus H.N.: An Experimental Investigation of Free Convection Heat Transfer from Rectangular Fin Arrays ; Journal of Heat Transfer, Trans ASME, Series C,85 1983. [2] Baskaya, S, Sivrioglu, M, and Ozek, M: Parametric Study of Natural Convection Heat Transfer from Horizontal Rectangular Fin Arrays, ; International Journal of Thermal Sciences, 39, pp. 797 805,2000. [3] Wankhede et.al.: Experimental Investigation of Heat Transfer from Inverted Notch Fin Arrays (INFA) Under Natural and Forced Convections ; IOSR Journal of Mechanical and Civil Engineering (IOSR- JMCE) ISSN: 2278-1684, pp: 14-22,2008. [4] Karagiozis A.N.: An Investigation of Laminar Free Convection Heat Transfer from Isothermal Finned Surfaces ; Ph.D. Thesis, University of Waterloo,Belgium,1991 [5] Prasolov R.S,: The effects of Surface Roughness of horizontal Cylinders on Heat transfer to air ; Inzhfiz. (In Russian), 4, 3-8, 1961. [6] Heya N., Takeuchi M., and Fujii T.: Influence of Various Surface Roughness on Free convection Heat transfer from a Horizontal Cylinder ; Chem. Engg. J. Vol.23, 185-190, 1982. International Journal of Modern Studies in Mechanical Engineering (IJMSME) Page 15

[7] Bhavnani S.H., and Bergles A.E.: Effect of Surface Geometry and Orientation on Laminar Natural Convection Heat transfer from a Vertical Flat Plate with Transverse Roughness Elements ; Int. J. Heat Mass Transfer, 33, 965-969, 1990. [8] Barhatte: Experimental and Computational Analysis and Optimization for Heat Transfer through Fins with Triangular Notch ; International Journal of Emerging Technology and Advanced Engineering, Volume 2, Issue 7,ISSN 2250-2459, 2012. [9] Toshihiro Tsuji, Tsuyoshi Kajitani, Tatsuhiko Nishino: Heat transfer enhancement in a turbulent natural convection boundary layer along a vertical flat plate ; International Journal of Heat and Fluid Flow 28, 1472 1483, 2007. AUTHOR S BIOGRAPHY Prof. S. A. Wani, is working as an Assistant Professor in Department of Mechanical Engineering, Padmabhooshan Vasantraodada Patil Institute of Technology, Budhgaon, Sangli, from last Six Years. His area of specialization is Heat and Power Engineering.His major research area is in the field of Natural Convection Heat Transfer. Prof. A. P. Shrotri, is working as an Associate Professor in Department of Mechanical Engineering, Padmabhooshan Vasantraodada Patil Institute of Technology, Budhgaon, Sangli, from last 32 years. His area of specialization is Production Engineering. Prof. D. K. Patil, is working as an Assistant Professor in Department of Mechanical Engineering, Padmabhooshan Vasantraodada Patil Institute of Technology, Budhgaon, Sangli, from last 2 years. His area of specialization is Production Engineering. Prof. A. A. Nannikar, is working as an Assistant in Department of Mechanical Engineering, Padmabhooshan Vasantraodada Patil Institute of Technology, Budhgaon, Sangli, from last 2 years. His area of specialization is Design Engineering. Citation: S. A. Wani et.al. (2018) Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array, International Journal of Modern Studies in Mechanical Engineering, 4(1), pp.11-16. DOI: http://dx.doi. org/10.20431/2454-9711.0401002 Copyright: 2018 S. A. Wani, This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. International Journal of Modern Studies in Mechanical Engineering (IJMSME) Page 16