IMPORTANT: Read and save these instructions. 30 and 36 Convertible Range Hood

Similar documents
IMPORTANT: Read and save these instructions. 24 and 30 Convertible Range Hood. Part No Rev. E

Installation Instructions and Use and Care

Installation Instructions

Installation Instructions

Microwave Oven Hood Combination

Electric Built-in Ceramic Cooktops

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

Quick Reference. Table of Contents: ff you need assistance:

Electric Built-in 24 and 27 Thermal Single and Double Ovens 24 and 27 Thermal Convection Single and Double Ovens

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Installation Instructions

Installation Instructions

Eve Ovens, Compactors, Room Air Conditioners, Dehumidifiers, Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers,Oishwash

Installation Instructions

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY

e Bath Fan with Light User s Guide

DRYER INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Bath Fan with Light User s Guide

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

important: Read and save these instructions. Quick Reference important: Table of Contents:

IMPORTANT: Read and save these instructions.

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

HOME APPLIANCES. " (76.2 cm) Electric Ran e. IMPORTANT: Read and save these instructions. O O. with self=cleaning thermal/convection [] []

Use & Care Guide AIR CONDITIONERS ACQ082 ACQ102 ACQ122 ACU082 ACU102 ACU124. fi'ter 1. Removable Control panel

Installation Instructions

e Bath Fan with Light User s Guide

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

36" GLASS SEALED-BURNER GAS COOKTOP

e Heater/Exhaust Fan/Light User s Guide

Installation Instructions Remote Blowers

-J:, WALL. Before you begin. A. Space requirements

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

24 IN. (61 CM) ELECTRIC WASHER/DRYER INSTALLATION INSTRUCTIONS WASHER/DRYER SAFETY DANGER WARNING


Installation Instructions

Quick Reference. 27" and 30" Electric Built-in Microwave/ Oven Combination. Table of Contents: If you need assistance: Pages

Installation Instructions

Use, Care, and Installation Guide

Installation Instructions

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Installation Instructions

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

GAS COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

APPUZO RANGE HOOD INSTALLATION

Cooktop Chimney Ventilation Hoods

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

Quick Reference. If you need assistance:

Installation Instructions

Installation Instructions

Installation Instructions Preference Wall Mount Range Hood

Installation Instructions

Use, Care, and Installation Guide READ AND SAVE THESE INSTRUCTIONS

Model: GVA-I 668IS2 GVA-IS2 688I IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY.

Installation Instructions

30 BUILT-IN MICROWAVE OVEN COMBINATION

Before you begin. A. Space requirements IMPORTANT:

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

GAS COOKTOP INSTALLATION INSTRUCTIONS

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Helpful Tip: NOTE:

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

Electric Dryer Installation Instructions

High Power Range Hood

Integrated Ventilation System

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions

136"ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded.

IMPORTANT: Read and save these instructions. Washer Dryer 120 Volt Installation Instructions. Gas Large Capacity Thin Twin IMPORTANT:

Undercounter Dishwasher

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Service Manual Electric Cooktop

ELECTRIC DRYER INSTALLATION INSTRUCTIONS 29" WIDE MODELS - U.S.A. ONLY

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

ELECTRIC DRYER INSTALLATION INSTRUCTIONS 29" WIDE MODELS U.S.A. ONLY

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

Installation Instructions

A. Remove the pre-mounted 6 round duct opening. D. Pre-mounted. rectangular plate. B. Put transition plate by first. E. Remove the pre-mounted

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

breeze easytm model # F100-1W

UseAndCare. l Call our Consumer Assistance Center with questions or comments. AIR CONDITIONERS II

Transcription:

IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with homeowner. Homeowner: Keep Installation Instructions for future reference. Save Installation Instructions for electrical inspector s use. 30 and 36 Convertible Range Hood

Before you start... Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the clearances specified. knockout for 30 model: 29-718 36 model: 35-718 Check the location where the range hood will be installed. The location should be away from strong draft areas, such as windows, doors, and strong heating vents. rear of hood Electrical Shock Hazard It is the customer s responsibility: l To contact a qualified electrical installer. l To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSVNFPA 70 - latest edition*, and all local codes and ordinances. Failure to do so could result in fire, electrical shock or other personal injury. Care must be taken when drilling holes into wall. Electrical wires may be concealed behind the wall covering. Failure to do so could result in electrical shock or other personal injury. Personal Injury Hazard Reaching over a heated cooking surface should be avoided. To reduce the hazard of being burned, the range hood should extend a minimum of 5 inches out from the bottom of the cabinet. Reaching over a heated cooking surface zould result in a serious burn. \ knockout for back vent Important: governing ordinances. Observe all codes and Grounded electric outlet is required. 1 -&w See Electrical wiring knockouts requirements, fl mounting holes Tools and materials needed for installation: compass or 7 circle template (not shown) Mobile home installation The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225, 1-1987, or latest edition, or with local codes. Four-wire power supply must be used and the appliance wiring must be revised. See Electrical requirements. Copies of standards listed may be obtained from: * National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 Panel A Electrical requirements Electrical Shock Hazard l Electrical ground is required on this appliance. l Do Not ground to a gas pipe. l Do Not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician. l Do Not have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in an electrical shock. l Do Not use an extension cord with this appliance. l Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded. Failure to follow these instructions could result in serious injury or death. If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine thal the grounding path is adequate. A A 115-volt, 60-Hz, AC-only, fused n electrical supplv is reauired. The total ampere load used including the range hood, must not exceed 90% of the rated capacity of the circuit. The ampere rating of the range hood is located on the serial/rating plate located on the underside of the range hood. B It is the personal responsibility and n obliaation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI/NFPA 70 - latest edition* and all local codes and ordinances, C D The range hood must be n connected with copper wire only. The range hood should be n connected directly to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed copper cable. A U.L.-listed strain relief must be provided at each end of the power supply cable. Wire sizes (COPPER WIRE ONLY) and connections must conform with the rating of the appliance as specified on the serial/rating plate. Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 - latest edition*, and all local codes and ordinances.

Venting requirements Now start... With range hood in kitchen. round ductwork Fire Hazard l Terminate venting system to outside.. Do Not terminate the vent in an atlic or other enclosed space. Failure to follow these instructions could result in a fire. Ductwork needed for installation is not included. If roof or wall cap has a damper, Do Not use damper supplied with hood. Determine which outside venting method needs to be used. NOTE: If a non-vented (recirculating) installation is desired, follow instructions on Panel D. The length of the ductwork and number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do Not install two elbows together. Use duct tape to seal all joints in the ductwork system. Ductwork can terminate either through the roof or wall. Use caulking to seal exterior wall or roof opening around exhaust hood. For the most efficient and quiet operation, it is recommended that the range be vented vertically through the roof through 7 round ductwork. Figures l-4 show common venting methods and what types of materials are needed. Vertical Roof Venting 7 round through the roof - damper located as far from hood as possible roof coo elbow 3-l/4 x 10 to round ductwork transition Figure 4 Recommended ductwork length Use 3- l/4 x lo or 7 ductwork with a maximum length of 26 feet for ductwork system. For best performance, use no more than three 90 elbows. To calculate the length of system you need, add the equivalent feet for each ductwork piece used in the system. See the following examples. 3- l/4 x lo ductwork system I Recommended I - +- 6 ft. 4 I lb-- wall cap Length of 3-1/4 xl0 system standard fittings = 13ft 3-114 x IQ 90 3-l/4 x IO flat 3-114 x 10 wall elbow = 5 ft. elbow = 12 ft. I cap=oft. I 7 ductwork system Property Damage l Slide cardboard or hardboard under range before moving range across floor. Failure to do so could cause damage to floor covering. l Cover countertop, cooktop or set-in range with a thick, protective covering. Failure to do so may result in property damage. 1 Disconnect and move freestanding n range from cabinet opening to provide easier access to upper cabinet and rear wall. Put a thick protective covering over cooktop, set-in range or countertop to protect from damage or dirt. 2 Determine which venting method I (roof or wall venting or non-venting) you need to use. This range hood is shipped for non-vented installation. If non-venting (recirculating) installation is desired, follow instructions on Panel D. Vented installation Remove screws from vent baffle on top of range hood. Remove vent baffle. - Figure 1 Vertical Roof Venting 1 roof cap 3-l/Lx lo to 7 transition Maximum length = 26 feet 1 - transition = 4.5ft. 2-90 elbows =lo ft. 8 feet straight = 8 ft. l- wall cap = 0 ft. Length of 7 system = 22.5 ft. 4. Turn vent baffle and reinsert in slot in top of range hood so that the word Vented is facing up, Fasten vent baffle with screws. 3-114 x 10 through the roof Recommended standard fittings lo knockouts Figure 2 Horizontal Wall Venting 1 knockouts Remove knockout from the wiring opening (top or rear) to be used. For rectangular venting, remove only the 3-l /4 x 10 rectangular opening knockout. For round ductwork venting through roof, remove both opening knockouts. Panel B Figure 3

terminal box cover 7. 6 m Remove terminal box Cover from Mae than one person is required to help with appliance intiallation because Of its weight and size. Failure to tallow these instructions may result in personal injury. 7 U Lift the range hood into final l position and center. Mark on the nderside of cabinet the location of the four kc 3 hole mounting slots. set IOn * hnnrl aside L.?k(,I - protected r surface. Numbers correspond to steps. Ta wire through rear, mark a line 7-l /2 from the right of the centerline on the Wall. Mark the point on this line that is 64-s/8 from the floor (or I -3/8 from underside of cabinet). Drill a T-1 /4 diameter hole through Wail at this point To vent through wall with 3-1 /A X 10 rectangular ductwork, measure from floor n 65-7/r and 62-3/8 (or l/8 and 3-5/8 dow from underside of cabinet) and mark on back wall, Measure and mark a line!5-1/4 to right and left of centerline connecting the two lines, Use a saber SUW t0 Cut a rectangular opening for the ductwork. 31, n rm Install ductwork through the vent opening in upper cabinei or wall. Complete venting system according to method needed. See *\/entina requirements. N Use caulking to 8 m Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made. To vent through the roof with 7 round ducfwark mark 4-l /2 and 5 in from back wait atoni the centerline on underside Of cabinet, Use these points as centers t0 draw 7-1 /g circles on underside of cabinet. Use a saber saw to cut the openings for the ductwork Repeat for the underside of the top of the cabinet, This will create slotted openings, I& m,kach rectangular damper to selectea >.ctanguiar vent opening, If damper is &ached to back of range hood, be Sure jamper hinge is toward the top. Far round ented installations, use round damper in juct to prevent air from flowing back into juclwork, - -.-rrh, If roof cap k-...ac ^ has Cm,-,-, a damper, rnnne hood, 4 413 m Run wiring through wall of cabinets according to the National Electricai Code and local codes and ordinances. DO Not turn on power until installation is complete. keyhole slot To wire throl through top, mark a line 7-112 from the righ. right of _ the centerline on the underside of the c cabinet, Mark the point on this tine the that is l-3/8 from back wall. Drill a 1-l /4 diameter die,..-.-. hole through the cabinet at this point. Panel C To vent through the roof with 3-j /4 X 10 rectangular ductwork, mark a line 1 and 5 from the buck wall on the underside of the cabinet Mark lines 5-l /4 to the right and left of the centerline on the underside of cabinet that connect the lines just drawn. Use a saber saw to cut a EdangUlar opening far the ductwork. Repeat for the underside of the top of the cabinet, Start screws through neck of each of the four keyhole mounting screw slots marked on the cabinet bottom, Lift -range hood into final position, feeding elc bctrical wire through wiring opening, PO &ion the range hood so that the large,d of the keyhole slots are over the screws, 7; en push the hood toward the wall SO that the e screws are in the neck of the SlOtS. Tic lhten mounting screws to cabinet, ml oking sure mounting screws are in,, narrow _._- ne-..!ck of _ slots, Make sure that damper blade. if used, rot&es up and down trew~

Non-vented installation!&wla II If\1 green screw _. grounding Remove terminal box cover. Connect the white and black wires of the power supply cable to the white and black leads in the hood with twist-on connectors, Connect the power supply grounding wire to the green, grounding wire inside the range terminal box with a twist-on wire connector. Use caulking to seal wire opening. Replace terminal box cover. Check vent baffle on top of range hood. Non-vented should be facing up. 2. Remove knockout from the wiring opening (rear or top) to be used. Do Not remove venting knockouts. 6.- I centerline To wire through top, mark a line 7-l /2 from the right of the centerline on the underside of the cabinet. Mark the point on this line that is l-3/8 from the back wall. Drill a l-l /4 diameter hole through cabinet at this point. terminal box cover Pull firmly on tab to remove filter/light lens from range hood. Turn filter/light lens so that charcoal filter pad is facing up. Lift tabs and remove charcoal filter pad. Discard charcoal filter pad. Place edge of filter/light lens in opening so that right side is above flange and tab faces downward. Press filter/light lens into position. Remove terminal box cover on range hood. Personal Injury Hazard More than one person is required to help with appliance installation because of its weight and size. Failure to follow these instructions may result in personal injury. keyhole slot centerline To wire through rear, mark a line 7-l /2 from the right of the centerline on the wall. Mark the point on this line that is 64-5/8 from the floor (or l-3/8 from underside of cabinet). Drill a l-l /4 diameter hole through wall at this point. 7. Replace terminal box cover. Continue installation with Step 13, Panel C. /$jiiji~~~~ij Keep Installation Instructions 4 L----i- 6 Lift range hood into final position and center. Mark on underside of cabinet location for the four keyhole mounting Set range hood uside on a protected surface. the slots. [ Congratulations! ) reference. The instructions will make reinstalling your Whirlpool 5. Determine centerline be made. cent&line L IL! and clearly mark a vertical in the area the vent opening will Panel D

Use & Care Information Electrical Shock Hazard l To prevent the risk of electrical shock or injury, be sure to disconnect power before cleaning or servicing. l If any electrical problem becomes evident during use, disconnect power to hood at fuse or breaker box. Failure to follow these instructions could result in electrical shock. Filter/light lens: For best results, remove and clean often. To remove filter/light lens: Operation of range hood For best results, turn range hood fan ON at beginning of cooking and allow it to run until all smoke and odors ore removed from room. To turn fan ON, HIGH and LOW: Turn fan control to turn fan to HIGH, LOW and OFF. Speed may be increased or decreased any-time during range hood operation. To turn range hood light ON and OFF: Turn light control to turn light ON or OFF. Light may be turned to OFF or ON anytime during range hood operation. I OFF OFF I : fan cdntrol light kontrol Pull firmly on filter tab to remove filter/light lens from range hood. To clean filter/light lens: Place filter/light lens in dishwasher or hot sudsy water to clean. Non-vented installation: Turn filter/light lens so that charcoal filter pod is facing up. Lift tabs and remove charcoal filter pod. Discord charcoal filter pad. Place filter/light lens in dishwasher or hot sudsy water to clean. Lift tabs and place new charcoal filter pod in filter/light lens. New charcoal filter pods, Port No. 883151, ore available from your dealer. To reinstall filter/light lens: Place edge of filter/light lens in opening so that right side is above flange and tab faces downward. Press filter/light lens into position. To clean fan motor: Every three years lubricate each motor bearing with a few drops of oil to help prolong motor life. Clean exterior of motor with a damp cloth and grease-cutting detergent. Exterior surfaces Clean the range hood with a mild detergent and soft cloth. Do Not use abrasive cleansers or steel wool pods. Light Do Not use bulb larger than 60 watts in light socket. Light bulb is not included. Panel E

If range hood does not operate... Check that the circuit breaker is not tripped or the house fuse blown. If you need assistance... The Whirlpool Consumer Assistance Center will answer any questions about operating or maintaining your range hood not covered in the Installation Instructions. The Whirlpool Consumer Assistance Center is open 24 hours a day, 7 days a week. Just dial l-(800) 253-1301 -the call is free. When you call, you will need the range hood model number and serial number. Both numbers con be found on the underside of the range hood. Whirlpool@ Range Hood Warranty LENGTH OF WARRANTY FULL ONE-YEAR WARRANTY From Dote of Purchase 1 WHIRLPOOL WILL PAY FOR FSP@ replacement ports and repair labor to correct defects in materials or workmanship. Service must be provided by on authorized WhirlpoolSM service If you need service... In the event your Whirlpool appliance should need service, call the dealer from whom you purchased the appliance or a Whirlpool-authorized service company. A Whirlpool-authorized service company is listed in the Yellow Pages of your phone directory under Appliance - Household - Major - Service or Repair. I You con also obtain the service company s name and number by dialing, free, within the continental United States, the Whirlpool Consumer Assistance Center number, l-(800) 253-1301. A special operator will tell you the name and number of your nearest Whirlpool-authorized service company. Maintain the quality built into your Whirlpool appliance - call a Whirlpool-authorized service company. WHIRLPOOL WILL NOT PAY FOR A. Any labor costs incidental to the replacement of defective parts. B. Consumable ports such as light bulbs and filters. C. Service calls to: 1. Correct the installation of the range hood. 2. Instruct you how to use the range hood. 3. Replace house fuses or correct house wiring. D. Repairs when range hood is used in other than normal, single-family household use. E. Pickup and delivery. This product is designed to be repaired in the home. F. Damage to range hood caused by occident, misuse, fire, flood, act of God or use of products not approved by Whirlpool. WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Outside the United States, a different warranty may also apply. For details, please contact your franchised Whirlpool distributor or military exchange. m Printed on recycled paper. 10% post consumer waste/ 50% recovered materials, Part No. 626701/883147 Rev. F 0 1994 Whirlpool Corporation Prepared by Whirlpool Corporation, Benton Harbor, Michigan 49022 Printed in U.S.A.