WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Similar documents
WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

WZH Ground source heat pumps

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZA High efficiency air to water heat pumps with HP compressor

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

GROUND SOURCE HEAT PUMPS WDH SERIES TECHNICAL MANUAL

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

pyxis u pyxis ua NEW rcgroupairconditioning

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

GHE Dehumidifiers for radiant cooling systems with heat recovery

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

pyxis pyxisa NEW rcgroupairconditioning

WATER TO WATER GROUND SOURCE HEAT PUMPS WHA SERIES TECHNICAL MANUAL

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Water chillers water/water type SIGMA Technical information manual

PYXIS U PYXIS U. rcgroupairconditioning

FH - GH Dehumidifiers for radiant cooling systems

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

unico pf unico pf rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CRIMSON & CRIMSON MAX

NEXT DL NEXT DL. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GEYSER kw. General information. Unique selling points

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Heat pump systems and Chillers

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

GLIDER EVO GLIDER EVO. rcgroupairconditioning

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

G E N E R A L C ATA L O G Dehumidif ers

Kälte Klima. Water cooled water chillers Not Reversible heat pumps from 18 kw to 75 kw. Series:

PRODUCT GUIDE

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

HIWARM COMPACT kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

Aquaflair TRAC-TRAF-TRAH

Water cooled chillers and heat pumps

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Air Cooled Chillers & Heat Pumps WinPACK HE-A

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

Modular Air-cooled Chillers

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Blue Box Epsilon Echos +

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

LVN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

kw COOLING kw HEATING

GUIDE SPECIFICATIONS AQUARIUS ii

nemo a hp rcgroupairconditioning R410A

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Galletti Water chillers and heat pumps catalogue

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

AWR MTD2 XE. Versions

TCHVZ TCEVZ

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CHAPTER 6 CONDENSING UNITS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Transcription:

Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems or those applications where it is necessary to have maximum efficiency when heating. They have been optimized on heating mode and are able to produce water up to 55 C. heat pumps are available in several versions. The most simple is a 2 pipe unit that can provide heating only. By fitting an external 3 port valve the unit can provide either heating or domestic hot water. There is also a 4 pipe unit that produces domestic hot water in a separate hydraulic circuit and can generate this irrespective of whether the unit is in heating or cooling mode. ll the units are also available in Free Cooling (FC) versions which provide low energy cooling by simply using the cool water that is available from either the ground source probes or the well water. Differing versions and a wide range of accessories, enable the optimal solution to be selected. OTHER VERSIONS standard, heating only. /SW5 heating only + domestic hot water circuit. /RV reversible heating/cooling. /RV/SW6 reversible version heating/cooling with independent DHW circuit. FC free cooling version (available in all versions) CCESSORIES DSSE: Soft starter elettronico. INSE: Scheda interfaccia seriale RS485. KVG: Rubber anti-vibration mountings. KVM: Spring anti-vibration mountings. LS00: Low noise version. MML: Refrigerant circuit pressure gauges. PCRL: Remote control panel. VM2D: 2 way modulating valve to reduce source water consumption (4-20 m; 0-10 V). Pumps contacts (source, user, domestic hot water pump). 52

Model /SW6 Heating capacity (EN14511) (1) Total input power (EN14511) (1) COP (EN14511) (1) User water flow (EN14511) (1) m 3 /h Heating capacity (EN14511) (2) Total input power (EN14511) (2) COP (EN14511) (2) Cooling capacity (EN14511) (3) Total input power (EN14511) (3) EER (EN14511) (3) Cooling capacity (EN14511) (4) Total input power (EN14511) (4) EER (EN14511) (4) Free Cooling capacity (5) Power supply Peak current Maximum input current Compressors type / n / Circuits Capacity steps n Water pump Pump available static pressure kpa Sound power (6) db() Sound pressure (7) db() 039 045 050 060 070 080 090 110 120 130 48,2 58,7 67,9 75,8 83,7 101,7 118,4 135,2 152,3 169,5 9,4 11,4 12,9 14,6 16,2 19,4 22,5 25,7 28,9 32,1 5,1 5,1 5,3 5,2 5,2 5,2 5,3 5,3 5,3 5,3 11,2 13,6 15,.8 17,6 19,4 23,6 27,5 31,4 35,4 39,4 37,0 45,0 52,4 58,1 64,2 77,9 90,6 103,3 115,3 128,3 9,2 11,1 12,7 14,3 15,7 18,7 21,6 24,5 27,5 30,5 4,0 4,1 4,1 4,1 4,1 4,2 4,2 4,2 4,2 4,2 56,2 70,2 82,8 86,9 101,8 123,1 143,4 157,0 185,6 207,3 9,9 12,1 13,7 15,8 17,9 21,3 24,5 27,8 31,7 35,6 5,7 5,8 6,0 5,5 5,7 5,8 5,9 5,6 5,9 5,8 41,0 50,8 60,5 62,8 73,8 90,1 104,9 114,6 135,0 150,3 9,7 11,8 13,3 15,1 16,9 20,2 23,4 26,7 30,2 36,6 4,2 4,3 4,5 4,2 4,4 4,5 4,5 4,3 4,5 4,1 24,0 28,0 33,0 37,0 41,0 50,0 58,0 66,0 74,0 83,0 400V / 3Ph / 50 Hz 116,0 143,0 149,0 189,0 194,0 230,0 257,0 266,0 313,0 324,0 34,0 40,0 44,0 49,0 54,0 64,0 73,0 82,0 93,0 104,0 Scroll / 2 / 1 2 2 2 2 2 2 2 2 2 2 1,1 1,1 1,1 1,1 1,1 1,5 1,5 2,2 2,2 2,2 155 130 100 80 60 105 65 80 60 50 80 80 81 82 82 83 83 84 84 85 52 52 53 54 54 55 55 56 56 57 OPERTION LIMITS Water temperature production ( C). 70 60 50 40 30 standard functioning contact the company - 10 0 10 20 30 40 50 Source temperature ( C). Performances refer to the following conditions: (1) (2) Heating: user water temperature 30/35 C, source water temperature 10/7 C. Heating: user water temperature 30/35 C, source water temperature 0/-3 C con 10% glycol. (3) (4) Cooling: user water temperature 23/18 C, source water temperature 30/35 C. Cooling: user water temperature 12/7 C, source water temperature 30/35 C. (5) (6) Cooling: user water temperature 10 C, source water temperature 20 C. Sound power level in accordance with ISO 9614. (7) Sound pressure level at 10 mt from the unit in free field conditions direction factor Q=2, calculated in accordance with ISO 9614 (LS version). 53 www.hidros.it

Model /SW6 Heating capacity (EN14511) (1) Total input power (EN14511) (1) COP (EN14511) (1) User water flow (EN14511) (1) m 3 /h Heating capacity (EN14511) (2) Total input power (EN14511) (2) COP (EN14511) (2) Cooling capacity (EN14511) (3) Total input power (EN14511) (3) EER (EN14511) (3) Cooling capacity (EN14511) (4) Total input power (EN14511) (4) EER (EN14511) (4) Free Cooling capacity (5) Power supply Peak current Maximum input current Compressors type / n / Circuits Capacity steps n Water pump Pump available static pressure kpa Sound power (6) db() Sound pressure (7) db() 152 162 144 164 190 210 240 260 300 320 189,1 208,7 185,4 203,4 236,8 270,3 304,7 339,1 378,2 420,3 35,2 38,3 35,6 38,7 45,1 51,4 57,8 64,2 70,3 76,5 5,4 5,4 5,2 5,3 5,3 5,3 5,3 5,3 5,4 5,5 44,2 48,9 43,0 47,3 55,0 62,8 70,8 78,9 88,3 97,8 143,1 157,7 142,6 157,0 182,4 208,1 233,6 258,9 288,4 318,6 33,5 36,5 34,7 38,0 43,5 49,4 55,4 61,4 67,4 73,4 4,3 4,3 4,1 4,1 4,2 4,2 4,2 4,2 4,3 4,3 222,5 253,6 214,7 241,3 297,5 340,2 385,4 430,3 485,2 540,0 38,8 42,3 39,6 43,1 49,8 56,4 64,1 71,9 79,0 86,0 5,7 6,0 5,4 5,6 6,0 6,0 6,0 6,0 6,1 6,3 161,5 182,8 156,6 175,4 217,0 247,9 179,9 311,5 349,4 387,3 36,6 39,8 37,1 39,9 47,8 54,9 61,3 67,9 74,5 80,9 4,4 4,6 4,2 4,4 4,5 4,5 2,9 4,6 4,7 4,8 92,0 102,0 90,0 99,0 115,0 162,0 148,0 165,0 184,0 204,0 400V / 3Ph / 50 Hz 362,0 372,5 279,8 294,0 330,0 348,0 406,0 428,0 476,5 497,5 114,5 125,0 109,6 128,0 146,0 164,0 186,0 208,0 229,0 250,0 Scroll / 2 / 1 Scroll / 4 / 2 2 2 4 4 4 4 4 4 4 4 3,0 3,0 3,0 3,0 3,0 4,0 4,0 4,0 5,5 5,5 140 117 143 120 80 150 120 90 140 120 85 85 85 85 86 88 88 88 90 90 57 57 57 57 58 60 60 60 62 62 OPERTION LIMITS Water temperature production ( C). 70 60 50 40 30 standard functioning contact the company - 10 0 10 20 30 40 50 mbient temperature ( C). (1) (2) Heating: user water temperature 30/35 C, source water temperature 10/7 C. Heating: user water temperature 30/35 C, source water temperature 0/-3 C con 10% glycol. (3) (4) Cooling: user water temperature 23/18 C, source water temperature 30/35 C. Cooling: user water temperature 12/7 C, source water temperature 30/35 C. (5) (6) Cooling: user water temperature 10 C, source water temperature 20 C. Sound power level in accordance with ISO 9614. (7) Sound pressure level at 10 mt from the unit in free field conditions direction factor Q=2, in accordance with ISO 9614 (LS version). 54

FRME ll units are made from hot-galvanised sheet steel, painted with polyurethane powder enamel and stoved at 180 C to provide maximum protection against corrosion. The frame is self-supporting with removable panels. ll screws and rivets used are made from stainless steel. The standard colour of the units is RL 7035. REFRIGERNT CIRCUIT The refrigerant utilised is R407C. The refrigerant circuit is assembled using internationally recognised brand name components with all brazing and welding being performed in accordance with ISO 97/23. Each refrigerant circuit is totally independent from the other with the result that any fault or alarm condition on one circuit does not influence the other. The refrigerant circuit includes: sight glass, filter drier, thermal expansion valve with external equalizer, Schrader valves for maintenance and control and pressure safety device (for compliance with PED regulations). COMPRESSORS The compressors used are a high performance scroll type that incorporates a special scroll design which enhances the efficiency of the refrigerant cycle when the source temperature is low. The compressors are all supplied with a crankcase heater and thermal overload protection by a klixon embedded in the motor winding. They are mounted in a separate enclosure thus enabling them to be maintained even if the unit is operating. ccess to this enclosure is via the front panel of the unit. The crankcase heater is always powered when the compressor is in stand-by. in-tube type and increases the efficiency of the refrigerant cycle at part loads. The source heat exchangers are factory insulated with flexible close cell material and are provided with a temperature sensor as antifreeze protection. USER EXCHNGER The user side heat exchanger is a braze welded, plate type heat exchanger, manufactured from ISI 316 stainless steel. From size 039 to size 162 they have a single water side circuit, from the size 144 they are double circuit, cross flow type.. ll units are supplied with a sub-cooler to enhance the performance of the refrigerant cycle. The user heat exchangers are factory insulated with flexible close cell material. MICROPROCESSORS ll units are supplied as standard with microprocessor controls. The microprocessor controls the following functions: control of the water temperature, antifreeze protection, compressor timing, compressor automatic starting sequence, alarm reset, volt free contact for remote general alarm, alarms and operation LED s. If required (available as an option), the microprocessor can be configured in order for it to connect to a site BMS system thus enabling remote control and management. The Hidros technical department can discuss and evaluate, in conjunction with the customer, solutions using MODBUS protocols. ELECTRIC ENCLOSURE The enclosure is manufactured in order to comply with the requirements of the electromagnetic compatibility standards CEE 73/23 and 89/336. ccess to the enclosure is achieved by removing the front panel of the unit. The following components are supplied as standard on all units: main switch, thermal overloads (protection of pumps and fans), compressor fuses, control circuit automatic breakers, compressor contactors, fan contactors and pump contactors. The terminal board has volt free contacts for remote ON-OFF, Summer/Winter change over (reversible type only) and general alarm. For all three phase units, a sequen- SOURCE HET EXCHNGERS The source side heat exchanger is a braze welded, plate type heat exchanger, manufactured from ISI 316 stainless steel. From size 039 to size 162 they have a single water side circuit, from size 144 they are double circuit, cross flow type. Utilisation of this type of exchanger results in a massive reduction of the refrigerant charge of the unit compared to a traditional shellce relay that disables the power supply in the event that the phase sequence is incorrect (scroll compressors can be damaged if they rotate in the wrong direction), is fitted as standard. CONTROL ND PROTECTION DEVICES ll units are supplied with the following control and protection devices: Return and supply user heat exchanger sensors, return and supply source heat exchanger sensors, high pressure switch with manual reset, low pressure switch with automatic reset, high pressure safety valve, compressor thermal overload protection, pump thermal overload protection (when present), source heat exchanger flow switch. OTHER VERSIONS /SW5 ONLY HETING UNIT WITH DOMESTIC HOT WTER This version is able to produce domestic hot water. It is supplied with an ON/OFF 3 way valve that diverts the water flow to a circuit for hot water production. These units are not available in the reversible version (RV) and cannot produce cold water. /RV REVERSIBLE VERSION HOT/COLD This version can be used for cooling during summer operation by using a 4 way reversing valve in the refrigerant circuit. They are also fitted with a second thermostatic valve and a liquid receiver. /RV/SW6 REVERSIBLE HOT/COLD INDEPENDENT DOMESTIC HOT WTER CIRCUIT This version has 4 pipes on the user side and is able to produce simultaneously, hot and cold water on 2 independent hydraulic circuits. The domestic hot water production is independent of the operation mode of the unit. This unit is supplied as standard with a reversing valve which enables the production of cold water in summer mode. 55 www.hidros.it

/FC; /FC /RV; /FC/SW5; / FC/RV/SW6 - FREE COOLING VERSIONS These versions, in addition to the characteristics described above, can produce cold water during summer operation using the cold water available from the source ground probes. ll free cooling versions are supplied with an intermediate heat exchanger and a 3 way valve which modulates the water flow to the user circuit depending on the required user cold water temperature. During free cooling mode the compressors may be off or will operate partially to augment the free cooling available. VERSIONS /1NT UNIT WITH WTER PUMP This version is supplied with a single, centrifugal type water pump with a high available pressure. The pump is connected as standard, to the user heat exchanger but upon request, can also be connected to the source heat exchanger. /LS LOW NOISE VERSION This version has acoustic insulation applied to the unit (both the compressor and its enclosure) in the form of compressor jackets and insulating material made with high density media coated with a heavy bitumen layer. /RV 2 PIPES VERSION. This version is capable of cooling during summer operation by using a 4 way reversing valve in the refrigerant circuit. 56

/FC/RV 2 PIPES VERSION. These versions, in addition to the characteristics described above, can produce cold water during summer operation using the cold water available from the source ground probes. ll free cooling versions are supplied with an intermediate heat exchanger and a 3 way valve which modulates the water flow to the user circuit depending on the required user cold water temperature. During free cooling mode the compressors may be off or will operate partially to augment the free cooling available. /FC/RV/SW6 2 PIPES VERSION. 57 www.hidros.it

/RV/SW6 4 PIPES VERSION. This unit is supplied with 4 pipes on the user side and is able to produce hot and cold water at the same time on two independent hydraulic circuits. The unit is supplied with an additional heat exchanger that is used as condenser for the domestic hot water production of which is independent of the operational mode of the unit. Model Code 039-045 050-060 070-080 090-110 120-130 Main switch Microprocessor control Remote ON/OFF digital input Summer/Winter digital input LS low noise version LS00 Partial heat recovery 20% RP00 (1NT) version - one pump without water tank 1NT Electronic soft starter DSSE Rubber anti-vibration mountings KVG Spring anti-vibration mountings KVM Refrigerant circuit pressure gauges MML Liquid line solenoid valve VSLI Remote control panel PCRL Serial interface card RS485 INSE 2 way modulating to control source water consumption VM2D Standard, Optional, Not vailable. 58

Model Code 152-162 144-164 190-210 240-260 300-320 Main switch Microprocessor control Remote ON/OFF digital input Summer/Winter digital input LS low noise version Partial heat recovery 20% (1NT) version - one pump without water tank Electronic soft starter Rubber anti-vibration mountings Spring anti-vibration mountings Refrigerant circuit pressure gauges Liquid line solenoid valve Remote control panel Serial interface card RS485 LS00 RP00 1NT DSSE KVG KVM MML VSLI PCRL INSE 2 way modulating to control source water consumption VM2D Standard, Optional, Not vailable. C C B B 039 162 144 320 Mod. (mm) B (mm) C (mm) Kg 039 1566 1101 1005 430 045 1566 1101 1005 440 050 1566 1101 1005 460 060 1566 1101 1005 470 070 1566 1101 1005 480 080 1566 1101 1005 490 090 1986 1101 1255 580 110 1986 1101 1255 600 120 1986 1101 1255 630 130 1986 1101 1255 650 152 1986 1101 1255 730 162 1986 1101 1255 760 Mod. (mm) B (mm) C (mm) Kg 144 1855 2480 800 1020 164 1855 2480 800 1090 190 1855 2480 800 1170 210 1855 2480 800 1210 240 1855 2480 800 1270 260 1855 2480 800 1320 300 1855 2480 800 1390 320 1855 2480 800 1430 59 www.hidros.it